ZM-1758-60 usa jmk inc 15 caldwell dr. amherst, nh 03031 p h: 603 886-4100 fx: 603 886-4115 email: info@jmkfilters.com eur jmk inc glasgow, scotland uk ph: 44 (0) 7785-310729 fx: 44 (0) 1415 -891884 the ZM-1758-60 filter is designed to work with syst ems with requirements to meet mil-std-461d, e, or f. th e filter is designed so that there are no resonant po ints in the operating range. the common mode insertion loss is also a minimum 50 db from 100mhz to 1.0ghz. this hi gh frequency performance will suppress high frequency signals on the power leads that can cause problems with radiated emissions. operating voltage = _________________28 - 40 vdc operating current = ______________________ 60 amp operating temperature = _______________(-55)?85c diel. withstanding (l-case) = ____800 vdc (1.0 minute) calculated mtbf = ________ 2,870,437 hrs at 30c gb failure rate = __________________________ 0.348379 ordering informatio n p/n: ZM-1758-60 insertion loss vs. frequency
|