  powr-gard ? fuse datasheet ? 2013 littelfuse powr-gard ? products littelfuse.com rev: 012413 1 of 3 class t C j ll n / j lls s eries fu ses 300/600 vac ? fast-acting ? 1-1200 a description JLLN/jlls fuses are less than 1 / 3 the size of comparable class r fuses and are typically used for short circuit protection of drives and surge sensitive components. when rated in accordance with the nec ? , JLLN/jlls fuses provide fast-acting overload and short circuit protection for non- inductive circuits and equipment. applications ? variable speed drive protection ? compact mains switches features/benefts ? extremely current-limiting ? compact design ? 200 ka interrupting rating specifcations voltage ratings ac: 300 v (JLLN) 600 v (jlls) dc: 160 v (JLLN 1 C 60 a) 125 v (JLLN 70 C 1200 a) 300 v (jlls) interrupting ratings ac: 200 ka rms symmetrical dc: 20 ka (JLLN & jlls) ampere range 1 C 1200 a approvals ac: standard 248-15, class t ul listed (file: e81895): JLLN (1 C 1200 a) jlls (1 C 800 a) ul recognized (file: e71611) JLLN pcb mount (35 C 60 a) jlls (900 C 1200 a) csa certifed (file: lr29862) JLLN/jlls (1 C 600 a) dc: ul listed (file: e81895): JLLN (35 C 1200 a) littelfuse self-certifed JLLN (1 C 30 a) jlls (1 C 1200 a) environmental rohs compliant ampere ra t i n gs 1 30 90 250 800 2 35 100 300 900* 3 40 110 350 1000 6 45 125 400 1100 10 50 150 450 1200 15 60 175 500 20 70 200 600 25 80 225 700 *j l l s o nl y note: contact the factory for rohs compliant class t fuses. web resources tc curves, downloadable cad drawings and other technical information: littelfuse.com/JLLN littelfuse.com/jlls recommended fuse holders lft30 series lft60 series lscr series for 700-800 a dimensions please refer to the class t dimensions on page 3 ordering information part numbering system series vol t age amp m o unt i n g s uff i x ca t alog n u mber o rderi n g n u mber jlls 600 6 C jlls006 jlls006.t JLLN 300 35 v JLLN035v JLLN035.txv JLLN xxx t xl package quantity series mounting options amperage t = 10 (1-60 a) v = 5 (70-100 a) x = 1 (110-1200 a) JLLN 35-60 a only blank = cartridge type xl = leaded xv = vertical mount xls = solder lead
powr-gard ? fuse datasheet ? 2013 littelfuse powr-gard ? products littelfuse.com rev: 012413 2 of 3 class t C j ll n / j lls s eries fu ses s hor t cir cu i t c u rre nt * a ppare nt rms s ymme t ri c al c u rre nt f or v ario u s fu se ra t i n gs 30 a 60 a 100 a 200 a 400 a 600 a 800 a 1200 a 5,000 750 1,225 1,400 2,850 4,600 5,000 5,000 5,000 10,000 945 1,525 1,700 3,600 6,000 8,500 9,400 10,000 15,000 1,050 1,700 2,000 4,050 6,600 9,750 10,500 13,000 20,000 1,150 1,900 2,200 4,450 7, 25 0 10,500 11,000 14,750 25,000 1,300 2,050 2,400 4,800 8,000 11,500 12,500 15,500 30,000 1,375 2,150 2,450 5,000 8,250 12,000 13,750 16,500 35,000 1,400 2,250 2,600 5,100 8,500 13,000 14,000 17,000 40,000 1,425 2,400 2,800 5,200 8,700 14,000 14,750 18,000 50,000 1,600 2,450 2,900 6,000 9,500 14,500 16,000 20,000 60,000 1,650 2,625 3,100 6,250 10,000 15,500 17, 3 0 0 21,000 80,000 1,825 2,800 3,400 7,000 11,000 17,000 18,750 23,000 100,000 2,000 3,100 3,700 7, 25 0 12,000 18,000 20,000 25,000 150,000 2,250 3,400 4,300 8,500 13,000 21,000 23,000 28,500 200,000 2,450 3,800 4,600 9,000 15,000 23,000 25,000 31,000 *prospective rms symmetrical amperes short-circuit current note: data derived from peak let-thru curves s hor t cir cu i t c u rre nt * a ppare nt rms s ymme t ri c al c u rre nt f or v ario u s fu se ra t i n gs 30 a 60 a 100 a 200 a 400 a 600 a 800 a 1200 a 5,000 700 775 1,100 1,650 3,500 4,000 5,000 5,000 10,000 900 1,000 1,400 2,100 4,400 5,100 6,750 8,250 15,000 1,000 1,100 1,600 2,400 5,000 5,900 7,75 0 10,000 20,000 1,100 1,250 1,800 2,700 5,500 6,500 8,750 11,000 25,000 1,230 1,300 1,950 2,900 6,000 7,000 9,500 12,000 30,000 1,300 1,475 2,050 3,100 6,400 7,500 10,000 12,500 35,000 1,330 1,575 2,150 3,300 6,750 7,75 0 10,500 13,500 40,000 1,430 1,600 2,300 3,500 7,000 8,000 11,000 14,000 50,000 1,500 1,750 2,400 3,700 7,500 8,750 12,000 15,000 60,000 1,700 1,900 2,700 4,000 8,000 9,500 12,500 16,000 80,000 1,850 2,100 2,800 4,400 9,000 10,500 14,000 17,500 100,000 2,000 2,250 3,150 4,800 9,750 11,500 15,000 18,500 150,000 2,300 2,600 3,600 5,500 11,000 13,000 17,500 22,000 200,000 2,600 2,800 3,900 6,000 12,000 14,500 19,500 24,000 *prospective rms symmetrical amperes short-circuit current note: data derived from peak let-thru curves 2000 3000 4000 6000 8000 10000 20000 30000 40000 60000 80000 100000 200000 100 200 300 400 600 800 1000 100 200 300 400 600 800 1000 2000 3000 4000 6000 8000 10000 20000 30000 40000 60000 80000 100000 200000 300000 400000 600000 800000 1000000 1200a 800a 600a 400a 200a 100a 60a 30a peak let -thru in amperes ava ilable f aul t current symmetrical r. m. s. amperes 2000 3000 4000 6000 8000 10000 20000 30000 40000 60000 80000 100000 200000 100 200 300 400 600 800 1000 100 200 300 400 600 800 1000 2000 3000 4000 6000 8000 10000 20000 30000 40000 60000 80000 100000 200000 300000 400000 600000 800000 1000000 800a 600a 400a 200a 100a 60a 30a peak let -thru in amperes available f aul t current symmetrical r. m. s. amperes jlls JLLN 2000 3000 4000 6000 8000 10000 20000 30000 40000 60000 80000 100000 200000 100 200 300 400 600 800 1000 100 200 300 400 600 800 1000 2000 3000 4000 6000 8000 10000 20000 30000 40000 60000 80000 100000 200000 300000 400000 600000 800000 1000000 1200a 800a 600a 400a 200a 100a 60a 30a peak let -thru in amperes ava ilable f aul t current symmetrical r. m. s. amperes 2000 3000 4000 6000 8000 10000 20000 30000 40000 60000 80000 100000 200000 100 200 300 400 600 800 1000 100 200 300 400 600 800 1000 2000 3000 4000 6000 8000 10000 20000 30000 40000 60000 80000 100000 200000 300000 400000 600000 800000 1000000 800a 600a 400a 200a 100a 60a 30a peak let -thru in amperes available f aul t current symmetrical r. m. s. amperes jlls JLLN peak let-thru curve and current-limiting effects of JLLN (300 v) fuses peak let-thru curve and current-limiting effects of jlls (600 v) fuses
powr-gard ? fuse datasheet ? 2013 littelfuse powr-gard ? products littelfuse.com rev: 012413 3 of 3 class t C j ll n / j lls s eries fu ses solder JLLN-ls leaded JLLN-l vertical mount JLLN-v pcb mounting options (JLLN 35-60 a only) b c a f d f e a b c d g a c d fig. 1 fig. 2 fig. 3 a mperes r e f er t o fig. no. s eries d ime n sio n s inc hes ( mm ) a b c d e f g 1 C 30 1 JLLN 7 ? 8 (22.2) 9 ? 32 (7.1) 13 ? 32 (10.3) jlls 1 1 ? 2 (38.1) 9 ? 32 (7.1) 9 ? 16 (14.3) 35 C 60 1 JLLN 7 ? 8 (22.2) 9 ? 32 (7.1) 9 ? 16 (14.3) 2 jlls 1 9 ? 16 (39.7) 13 ? 16 (20.6) 13 ? 32 (10.3) 1 (25.4) 1 ? 16 (1.6) 1 3 ? 32 ( 27.8 ) 70 C 100 3 JLLN 2 5 ? 32 (54.8) 1 9 ? 16 (39.7) 3 ? 4 (19.1) 13 ? 16 (20.6) 27 ? 32 (21.4) 9 ? 32 (7.1) 1 ? 8 (3.2) jlls 2 61 ? 64 (75.0) 2 23 ? 64 (59.9) 3 ? 4 (19.1) 13 ? 16 (20.6) 1 41 ? 64 (41.7) 9 ? 32 (7.1) 1 ? 8 (3.2) 110 C 200 3 JLLN 2 7 ? 16 (61.9) 1 11 ? 16 (42.9) 7 ? 8 (22.2) 1 1 ? 16 ( 27.0 ) 27 ? 32 (21.4) 11 ? 32 (8.7) 3 ? 16 (4.8) jlls 3 1 ? 4 (82.6) 2 1 ? 2 (63.5) 7 ? 8 (22.2) 1 1 ? 16 ( 27.0 ) 1 21 ? 32 (42.1) 11 ? 32 (8.7) 3 ? 16 (4.8) 225 C 400 3 JLLN 2 3 ? 4 (69.9) 1 27 ? 32 (46.8) 1 (25.4) 1 5 ? 16 (33.3) 53 ? 64 (21.0) 13 ? 32 (10.3) 1 ? 4 (6.4) jlls 3 5 ? 8 (92.1) 2 23 ? 32 ( 69.1) 1 (25.4) 1 19 ? 32 (40.5) 1 23 ? 32 (43.7) 13 ? 32 (10.3) 1 ? 4 (6.4) 450 C 600 3 JLLN 3 1 ? 16 (77.8 ) 2 1 ? 32 (51.6) 1 1 ? 4 (31.8) 1 19 ? 32 (40.5) 7 ? 8 (22.2) 31 ? 64 (12.3) 5 ? 16 (7.9 ) jlls 3 63 ? 64 (101.2) 2 61 ? 64 (75.0) 1 1 ? 4 (31.8) 2 1 ? 16 (52.4) 1 49 ? 64 (44.8) 31 ? 64 (12.3) 5 ? 16 (7.9 ) 700 C 800 3 JLLN 3 3 ? 8 (85.7) 2 7 ? 32 (64.3) 1 3 ? 4 (44.5) 2 1 ? 16 (52.4) 7 ? 8 (22.2) 35 ? 64 (13.9) 3 ? 8 (9.5) jlls 4 21 ? 64 (109.9) 3 11 ? 64 (80.6) 1 3 ? 4 (44.5) 2 1 ? 2 (63.5) 1 55 ? 64 (47.2) 35 ? 64 (13.9) 3 ? 8 (9.5) 900 C 1200 3 JLLN 4 (101.6) 2 17 ? 32 (64.3) 2 (50.8) 2 1 ? 2 (63.5) 1 1 ? 32 (26.2) 39 ? 64 (15.5) 7 ? 16 (11.1) jlls 5.27 (133.9) 3.80 (96.5) 2 (50.8) 2.63 (66.8) 2.30 (58.4) 0.67 (15.5) 0.44 (11.2) dimensions inches (mm)


▲Up To Search▲   

 
Price & Availability of JLLN

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X