  mdeu 0 2 - hi series d c/dc converter 2w , ultra - high i/o isolation , d ip package e - mail:sales@minmax.com.tw tel:886 - 6 - 2923150 201 5 /05 / 22 p 2 page 1 of 4 features ? industrial standard d ip - 16 package ? ultra - h i gh i/o isolation 8 000vdc ? common mode transient immunity: 15 kv/s ? qualified for igbt and hi gh isolation application s ? operating temp. range - 25 c to +8 0 c ? ul/cul/iec/en 60950 - 1 safety approval product overview the minmax md eu02 - hi series is a new range of isolated 2 w dc/dc converter modules in dip - 16 package which feature a ultra - h i gh i/o - isolation voltage rated for 8000vdc with reinforced insulation. a very high common mode transient immunity with 15kv / s qualifies these product for ig b t driver applications.there are 15 models available for 5, 12, an d 24vdc input.these converters offer a cost - effective solution for wind turbine, solar panel, transporation systems, industrial control equipments and some igbt driver applications where a very high i/o - isolation is required. model selection guide model number input voltage (range) output voltage output current input current load regulation max. c apacitive load efficiency (typ.) max. min. @max. load @no load @max. load vdc vdc ma ma ma ( t yp.) ma ( t yp.) % (m ax.) f % mdeu02 - 05s05hi 5 (4.5 ~ 5.5) 5 4 0 0 8 615 60 12 330 65 mdeu02 - 05s12hi 12 165 3 609 10 65 mdeu02 - 05s15hi 15 133 2.5 605 10 66 mdeu02 - 05d12hi 12 83 1.5 553 10 100# 72 mdeu02 - 05d15hi 15 66 1 542 10 73 mdeu02 - 12s05hi 12 (10.8 ~ 13.2) 5 40 0 8 256 30 12 330 65 mdeu02 - 12s12hi 12 165 3 254 10 6 5 mdeu02 - 12s15hi 15 133 2.5 252 10 66 mdeu02 - 12d12hi 12 83 1.5 224 10 100# 74 mdeu02 - 12d15hi 15 66 1 220 10 75 mdeu02 - 24s05hi 24 (21.6 ~ 26.4) 5 40 0 8 128 15 12 330 65 mdeu02 - 24s12hi 12 165 3 127 10 65 mdeu02 - 24s15hi 15 133 2.5 126 10 66 mdeu02 - 24d12hi 12 83 1.5 112 10 100# 74 mdeu02 - 24d15hi 15 66 1 110 10 75 # for each output input specifications parameter model min. typ. max. unit input voltage range 5v input models 4.5 5 5.5 vdc 12v input models 10.8 12 13.2 24 v input models 21.6 24 26.4 input surge voltage (1 sec. max. ) 5v input models - 0.7 --- 9 12v input models - 0.7 --- 18 24 v input models - 0.7 --- 30 input filter all models internal capacitor type
m deu 0 2 - hi series d c/dc converter 2w , ultra - high i/o isolation , d ip package e - mail:sales@minmax.com.tw tel:886 - 6 - 2923150 201 5 / 05 / 22 p2 page 2 of 4 output specifications parameter conditions min. typ. max. unit output voltage accuracy --- 2 .0 4 .0 % output voltage balance dual output, balanced loads --- 0.1 1.0 % line regulation vin=min. to max. @full load --- 1.2 1.5 % load regulation io=20% to 100% see model selection guide ripple & noise 0 - 20mhz bandwidth --- --- 1 5 0 mv p - p temperature coefficient --- 0.01 0.02 %/ short circuit protection 0.5 second m ax. automatic recovery isolation, safety standards parameter conditions min. typ. max. unit i/o isolation voltage rated for 60 seconds 4 000 --- --- v a c rms tested f or 1 second 80 00 --- --- vdc i/o isolation resistance 500 vdc 10 --- --- g i/o isolation capacitance 100khz, 1v --- 15 2 0 pf common mode transient immunity 15 --- --- kv /s safety approvals ul/cul 60950 - 1 recognition(ul certificate), iec/en 60950 - 1(cb - report ) general specifications parameter conditions min. typ. max. unit switching frequency 5 0 8 0 1 0 0 khz mtbf (c alc u lated) mil - hdbk - 217f@25 , ground benign 2 ,000,000 --- --- hours environmental specifications parameter conditions min. max. unit operating ambient temperature range (see power derating curve) natural convection - 25 + 80 case temperature --- + 105 storage temperature range - 50 +125 humidity (non condensi n g) --- 95 % rel . h cooling natural convection lead temperature (1.5mm from case for 10sec.) --- 260 power derating curve ~ a m b i e n t t e m p e r a t u r e o u t p u t p o w e r ( % ) 0 2 0 4 0 6 0 8 0 1 0 0 - 2 5 0 2 0 6 0 1 0 0 1 1 0 8 0 4 0 4 0 0 l f m 2 0 0 l f m 1 0 0 l f m n a t u r a l c o n v e c t i o n 2 0 l f m c
m deu 0 2 - hi series d c/dc converter 2w , ultra - high i/o isolation , d ip package e - mail:sales@minmax.com.tw tel:886 - 6 - 2923150 201 5 / 05 / 22 p2 page 3 of 4 notes 1 specifications typical at ta=+25 , resistive load, nominal input voltage and rated output current unless otherwise noted. 2 these power converters require a minimum output loading to maintain specified regulation , o peration under no - load conditions will not damage these modules; however they may not meet all spec ifications listed. 3 we recommend to protect the converter by a slow blow fuse in the input supply line. 4 other input and output voltage may be available, please contact factory. 5 that natural convection is about 20lfm but is not equal to still air (0 lfm). 6 specifications are subject to change without notice. package specifications mechanical dimensions pin connections pin single output dual output 1 - vin - vin 7 nc nc 8 nc common 9 +vout +vout 10 - vout - vout 16 +vin +vin nc: no connection ? all dimensions in mm (inches) ? tolerance: x.x 0. 5 (x.xx0.0 2 ) x.xx 0. 25 ( x.xxx0.0 1 ) ? pins 0. 05( 0.002) physical characteristics case size : 23.8x13.4x8.6mm (0.94x0.53x0.34 inches) case material : non - conductive black plastic ( flammability to ul 94v - 0 rated ) pin material : p hosphor bronze weight : 5.1g 8 . 6 [ 0 . 3 4 ] 0 . 5 [ 0 . 0 2 ] 1 0 . 1 6 [ 0 . 4 0 ] 1 3 . 4 [ 0 . 5 3 ] 1 7 8 16 10 9 0.50 [0.02] 1 . 6 2 [ 0 . 0 6 ] bottom view 23.8 [0.94] 15.24 [0.60] 2.54 [0.10] 3.0 [0.12] 3 . 8 [ 0 . 1 5 ]
m deu 0 2 - hi series d c/dc converter 2w , ultra - high i/o isolation , d ip package 18, sin sin road, an - ping industrial district, tainan 702, taiwan tel: 886 - 6 - 2923150 fax: 886 - 6 - 2923149 e - mail: sales@minmax.com.tw 201 5 / 05 / 22 p 2 page 4 of 4 minmax technology co., ltd. test setup peak - to - peak output noise measurement test use a cout 0. 47 f ceramic capacitor. scope measurement should be made by using a bnc socket, measurement bandwidth is 0 - 20 mhz. position the load between 50 mm and 75 mm from the dc/dc converter. technical notes maximum capacitive load the md eu02 - hi series has limitation of maximum connected capacitance at the output. the power module may be operated in current limiting mode during start - up, affecting the ramp - up and the startup time. for optimum performance we recommend 100 f maximum capaciti ve load for dual outputs and 330 f capacitive load for single outputs. the maximum capacitance can be found in the data sheet. input source impedance the power module should be connected to a low ac - impedance input source. highly inductive source impedances can affect the stability of the power module. in applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at th e input to ensure startup. capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low equivale nt series resistance (esr < 1.0 at 100 khz) capacitor of a 2.2 f for the 5v input devices, a 1.0 f for t he 12v input devices and a 0.47 f for the 24v input devices. output ripple reduction a good quality low esr capacitor placed as close as practicable across the load will give the best ripple and noise performan ce. to reduce output ripp le, it is recommended to use 3.3 f capacitors at the output. thermal considerations many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board sp acing. to avoid exceeding the maximum temperature rating of the components inside the power module, the case temper ature must be kept below 1 0 5 . the derating curves are determined from measurements obtained in a test setup . +out -out +vin -vin single output dc / dc converter resistive load scope copper strip cout copper strip +out -out +vin -vin dual output dc / dc converter resistive load scope copper strip cout com. scope cout copper strip copper strip + +out -out +vin -vin dc / dc converter load dc power source + - cin +out -out +vin -vin load dc power source + - cout single output dc / dc converter +out -out +vin -vin load dc power source + - cout com. dual output dc / dc converter load cout dut position of air velocity probe and thermocouple 50mm / 2in air flow 15mm / 0.6in


▲Up To Search▲   

 
Price & Availability of MDEU02-HI

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X