Part Number Hot Search : 
FR307G 5KP30A 74LVC1 B2000 JANTX1N 20016 74AUP 0100100
Product Description
Full Text Search
 

To Download N5393D Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  keysight N5393D pci express ? 3.0 (gen3) software for infniium oscilloscopes data sheet
02 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet table of contents features ...................................................................................................................................... 4 benefits ....................................................................................................................................... 5 easy test definition ................................................................................................................... 6 pci express 3.0 ........................................................................................................................... 7 configurability and guided connections ................................................................................. 8 reports with margin analysis .................................................................................................... 9 extensibility ................................................................................................................................. 11 automation ............................................................................................................. ..................... 12 switch matrix .............................................................................................................................. 13 receiver stressed eye calibration ............................................................................................. 14 reference clock measurements ............................................................................................... 16 powerful debugging aids .......................................................................................................... 17 measurement requirements ..................................................................................................... 19 recommended test accessories .............................................................................................. 20 test performed ........................................................................................................................... 21 ordering information ................................................................................................................. 22
03 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet verify and debug your pci express ? designs more easily keysight technologies, inc. pci express electrical performance validation and compliance software provides you with a fast and easy way to verify and debug your pci express 3.0, 2.0, and 1.1/1.0a designs for both silicon validation (as per the pcie ? base specification) as well as for add-in cards and motherboard systems (as per the pcie cem specification). the pci express electrical test software allows you to automatically execute pci express electrical transmitter tests, and it displays the results in a flexible report format. in addition to the measurement data, the report provides a margin analysis that shows how closely your device passed or failed each test. the pci express electrical test software utilizes the prescribed test methods and algorithms as required by the pci express card electromechanical (cem) specifications for all current pci express standards. this produces results that are not only consistent with the pci-sig ? sigtest utility, but also provides you with a fast and easy means of executing complex two-port motherboard tests and single port add-in card test with total automation. in addition to transmitter testing, the pci express electrical test software also provides an optional receiver test calibration test suite, which allows you to setup your n4903b jbert bit error ratio tester for performing pci express 3.0 jitter tolerance testing under the pcie 3.0 base specification. the pci express electrical performance validation and compliance software performs a wide range of electrical tests as per the pci express pci express 2.0 and 1.1/1.0a. electrical specifications for add - in cards and motherboard systems as documented in section 4 of the base specification and section 4 of the card electromechanical specification. tests for pci express 3.0 (based on section 4.3.3.10 and 4.3.3.13) are also included to help you test your products against for the next generation of this powerful i/o technology. in addition to full swing (800 mv) testing, the software also supports testing for low-power, half-swing devices (400 mv) as per the pci express architecture mobile graphics low-power addendum to the pci express base specification revision 1.0. 1. peripheral component interconnect special interest group
04 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet features the pci express electrical test software offers several features to simplify the validation of pci express designs: C pcie 3.0 measurements for uncorrelated tj, dj, and pwj, pseudo package loss, and preset de-emphasis and preshoot. C automated 1.6 m unit interval (or greater) testing for highest accuracy when embedding pcie reference channel and package model losses C results consistent with pci-sig sigtest software utility C support for de-embedding of test fixtures and cables 1 C test setup wizard for ease-of-use C wide range of electrical transmitter and reference clock tests C pci-sig sigtest clock recovery algorithm C optional integrated receiver test calibration suite for automated calibration (base spec) of your n4903b jbert 2 C automated scope measurement setup C test results report generation C pass/fail margin analysis C reference clock phase jitter analysis C two-port (explicit clock and data) supported for motherboard signal quality testing C support for both full-swing and low-power, half-swing devices. with the pci express electrical test software, you can use the same oscilloscope you use for everyday debugging to perform automated testing and margin analysis based on the pci- sig-specified tests. pci express compliance testing to pass signal quality testing at a pci-sig-sponsored compliance workshop, your product must successfully pass gold suite testing, based on the pci-sig sigtest application. the sigtest application tests your device against the minimum signal-quality performance requirements for pci. if you are developing receivers and transmitters for add-in boards and system motherboards, the pci express electrical test software helps you execute the sigtest tests and additional oscilloscope already completed tests. see the list of tests in table 3 on page 16 (for 1.1 test coverage). while sigtest tests provide a good overview of pci express electrical signal quality, they address only a small subset of the electrical compliance measurements specified in the pci-sig specification. the sigtest application also provides minimal reporting capability with pass/fail indication and measurement values, and has limited debugging capabilities to decipher eye mask violations or excessive jitter. for pci e xpress 3.0 measurements, the software automatically calculates uncorrelated total jitter, uncorrelated deterministic jitter, uncorrelated pwj necessary for validating new pcie 3.0 compliant chipsets. for versions of devices compliant with pci express 2.0 or earlier, random jitter is also reported for completeness and a voltage margin eye diagram is included in the final html report. dj and tj values are specified in the pcie 2.0 specification and are required for compliance verification. 1. requires the purchase of the optional keysight infiniisim waveform transformation toolset for infiniium oscilloscopes. 2. requires the purchase of N5393D-4fp software license. receiver test hardware and fixtures not included and must be purchased separately. figure 1. pci express 2.0 supports data rates up to 5.0 gt/s as shown above (C3.5 db de-emphasis).
05 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet benefts pci express electrical test software benefts the pci express electrical test software saves you time by setting the stage for automatic execution of pci express electrical tests, including jbert jitter stress calibration (optional). part of the difficulty of performing electrical tests for pci express is hooking up the oscilloscope, loading the proper setup files, and then analyzing the measured results by comparing them to limits published in the specification. the pci express electrical test software does much of this work for you. in addition, if you discover a problem with your device, robust debug tools are available to aid in root-cause analysis. these debug tools are provided by the keysight e2688a high-speed serial data analysis software, which you must install on your oscilloscope to use the pci express electrical test software. the software also now has an integrated interface for controlling the infiniisim waveform transformation toolset for de-embedding of test fixtures. introduced with pcie 2.0, de- embedding of test fixtures utilizes s-parameters as input to create a de-embed model that helps to restore high frequency signal content that is often lost or significantly attenuated by test fixtures and cables. this can help to recover significant jitter margin normally lost to fixtures used in a test setup. the software can be purchased with an optional test suite for performing the calibration of your keysight jbert (b) bit error ratio tester for stressed eye receiver testing for pcie 3.0 silicon. this helps ensure consistent run-to-run setup of the instrumentation, saving you time and providing consistent and accurate receive test results. the pci express electrical test software offers many more electrical tests than the sigtest application. unlike the sigtest application, the pci express electrical test software automatically configures the oscilloscope for each test, and it provides an informative results report that includes margin analysis indicating how close your product is to passing or failing a particular test assertion. table 1 shows a side-by-side comparison of the capabilities of the sigtest application and the keysight pci express electrical test software. a list of the measurements made by the pci express electrical test software can be found in table 3, (table 3 contains comparison of sigtest vs. keysight). table 1. comparison of capabilities of the keysight pci express electrical test software and the pci-sig sigtest application capability keysight pci express software pci-sig sigtest support for pcie 3.0 base spec n/a integrated de-embedding support yes (infniisim waveform transformation toolset required) no number of measurement assertions 16+ 4 support for pcie 1.0a, 1.1, 2.0 yes yes reference clock tests 10 (1.1) 0 1 automated oscilloscope setup for each measurement yes, guided no, single setup measurement results pass/fail with margin analysis pass/fail with measured value cem based measurement methodology yes yes clock recovery method pci-sig sigtest or 1st/2nd order pll pci-sig sigtest brick wall flter (2.0 testing) yes yes custom html report generation yes no support for low power device yes no selectable number of tests performed yes no multi-trial run support yes no debug mode for what if analysis yes no compliance test boards supported cbb1, cbb2, clb1, clb2 cbb1, cbb2, clb1, clb2 1. pci-sig offers a separate utility (clock_jitter) for analyzing reference clock phase jitter.
06 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet easy test defnition figure 2. the software allows you to easily specify the test standard you want to use to test the compliance of your device. this makes test setup easy as only the appropriate tests for the test point you pick are shown on later test selection pages. figure 3. the keysight automated test engine guides you quickly through selecting tests, configuring tests, setting up the connection, running the tests, and viewing the results. individual tests or groups of tests are easily selected with a mouse click. the pci express electrical test software extends the ease-of-use advantages of keysights infiniium oscilloscopes to testing pci express designs. the keysight automated test engine walks you quickly through the steps required to define the tests, set up the tests, perform the tests, and view the test results. you can select a category of tests all at once, or specify individual tests. you can save tests and configurations as project files and recall them later for quick testing and review of previous test results. straightforward menus let you perform tests with a minimum of mouse clicks. the software allows you to easily specify the test standard you want to use to test the compliance of your device. this makes test setup easy as only the appropriate tests for the test point you pick are shown on later test selection pages. test with ssc enabled or with a clean clock (for compliance) choose half swing if testing low power devices test your reference clock for phase jitter to help ensure clean high data rate transmissions de-embed test fixtures with the optional infiniisim waveform transformation toolset pick the standard you want to test against choose the test point or specific signal you want to test easy to follow task flow for configuring and running tests select one test or a group of tests with a single mouse click
07 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet pci express 3.0 the N5393D includes support for testing pci express 3.0 devices. the tests supported include new jitter, voltage, de-emphasis, preshoot, pseudo s21 loss and others defined by the pci express 3.0 base specification. in addition, with the addition of the optional infiniisim waveform transformation toolset, the N5393D also integrates de-embedding of test channel and cable losses with user-supplied s-parameters for fixtures and connectors. de-embedding is used to recover jitter losses due to the attenuation of high frequency elements caused by the test channel. figure 4. pci express 3.0 transmitter tests. figure 5. the N5393D integrates de-embedding capability when coupled with the optional infiniisim waveform transformation toolset. select pci express transmitter tests to test your new pcie 3.0 device.
08 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet the pci express electrical test software provides flexibility in your test setup. it guides you to make connection changes with hookup diagrams when the tests you select require it. all pci express electrical compliance tests you perform are based on the official pci-sig approved set of test fixtures. the compliance fixtures include the compliance base board (cbb2) for add-in card testing, and the compliance load board (clb2) for motherboard or system testing. connection to the compliance test fixtures is selectable between sma/smp cables or keysight infiniimax active differential probes. confgurability and guided connections figure 6. in configuring the tests, you specify the device to test, its configuration, and how the oscilloscope is connected. figure 7. when you make multiple tests where the connections must be changed, you are prompted with connection diagrams and/or photographs. figure 8. the pci-sig compliance base board (cbb2) for gen2 add-in card testing, and the compliance load board (clb2) for gen2 motherboard or host system testing. specify 1 million ui (or more) for your jitter measurements show the spectral response of your reference clock in the critical 1.5 to 22 - m hz region toggle circuit to switch between gen1 (2.5 gbit/s) and gen2 (50 gbit/s) you are prompted to make the appropriate connections for the set of tests if more than one test setup connection is required, you will be notified here
09 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet reports with margin analysis in addition to providing you with measurement results, the pci express electrical test software provides a report format that shows you not only where your product passes or fails, but also reports how close you are to the limits specified for a particular test assertion. you can select the margin test report parameter, which means you can specify the level at which warnings are issued to alert you to electrical tests where your product is operating close to the official test limit defined by the pci express 2.0, 1.0a or 1.1 specifications. figure 9. the pci express electrical test software results report documents your test, indicates the pass/fail status, the test specification range, the measured values, and shows how much margin you have. figure 10. the html report provides additional details including test setup conditions, graphical results, and test limits (where appropriate). test results in an easy-to-read html formatted report overall test description summary test results test setup conditions gen2 voltage margin results presented in identical format used by sigtest
10 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet reports with margin analysis (continued) figure 11. how close you are to passing or failing a test is indicated as a % in the margin field. a result highlighted in yellow or red indicates that the margin threshold level for a warning or failure was detected. margin values indicate when the results are approaching test limits. warnings and failures are highlighted. user set margin thresholds for warning and failure indicators
11 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet you may add additional custom tests or steps to your application using the user defined application (uda) development tool ( www.keysight.com/find/uda ). use uda to develop functional add-ins that you can plug into your application. add-ins may be designed as: C complete custom tests (with configuration variables and connection prompts) C any custom steps such as pre or post processing scripts, external instrument control and your own device control figure 12. importing a uda add-in into your test application. figure 13. uda add-in tests and utilities in your test application. extensibility
12 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet you can completely automate execution of your applications tests and add-ins from a separate pc using the included n5452a remote interface feature (download free toolkit from www.keysight.com/find/ scope-apps-sw ). you can even create and execute automation scripts right inside the application using a convenient built-in client. the commands required for each task may be created using a command wizard or from remote hints accessible throughout the user interface. using automation, you can accelerate complex testing scenarios and even automate manual tasks such as: C opening projects, executing tests and saving results C executing tests repeatedly while changing configurations C sending commands to external instruments C executing tests out of ord combine the power of built-in automation and extensibility to transform your application into a complete test suite executive: C interact with your device controller to place it into desired states or test modes before test execution. C configure additional instruments used in your test suite such as a pattern generator and probe switch matrix. C export data generated by your tests and post-process it using your favorite environment, such as matlab, python, labview, c, c++, visual basic etc. C sequence or repeat the tests and add-in custom steps execution in any order for complete test coverage of the test plan. automation figure 14. remote programming script in the automation tab. figure 15. combine the power of built-in automation and extensibility to transform your application into a complete test suite executive. custom tests matlab processing c++ script labview results dut or external instrument control live signals custom tests/steps or post processing pattern generator switch matrix uda add-in - dut control - instrument control compliance app + automation engine uda add-in - custom test/steps - post processing dut
13 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet switch matrix the keysight N5393D option 7fp switch matrix software tool for the pci express compliance application, used together with switch matrix hardware, enables fully automated testing for this multi-lane digital bus interface. the benefits of this automated switching solution include: C eliminate reconnections, which saves time and reduces errors through automating test setup for each lane of a multi-lane bus. C maintain accuracy with the use of unique n2809a precisionprobe or infiniisim features to compensate for switch path losses and skew. C customize testing by using remote programming interface and the user-defined application tool for device control, instrument control and test customization. more information of the switching solution and configuration, visit http://literature. cdn.keysight.com/find/switching and the keysight application note with the publication number 5991-2375en. figure 17. switch matrix software feature enabled in the compliance application. figure 16. automated testing for multi-lane digital bus interface through switching solution.
14 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet receiver stressed eye calibration figure 18. n4903b jbert setup for pcie 3.0 receiver stress testing. the pci express 3.0 base specification outlines the requirements for a pcie 3.0 compliant receiver equalizer. the capabilities defined employ a reference equalizer that consists of a ctle (continuous time linear equalizer) and a single tap dfe (decision feedback equalizer). in order to ensure that your devices receiver equalizer is at least as capable as the reference equalizer defined in the pcie 3.0 base specification, it is necessary to execute a stressed eye receiver test. the signal that must be presented to the receiver must represent a worst case condition yet still be a valid and compliant pcie 3.0 signal. to achieve this calibrated worst case signal, it is necessary to carefully construct a significantly small amplitude signal that contains a prescribed amount of certain specified impairments. these impairments include sinusoidal jitter, random jitter, and channel induced intersymbol interference (isi). in addition, it is necessary to add common mode and differential mode noise simultaneously to the jitter cocktail in order to emulate system crosstalk. the N5393D-4fp along with your n4903b jbert bit error ratio tester and required accessories, such as an 81150a pulse function arbitrary noise generator, n4916b de-emphasis signal converter, and n4915a-014 pci express 3.0 calibration channels. figure 19. setting up instrument control of the n4903b and 81150a from the pcie application. set target stressed voltage test parameters for the calibration set target stressed jitter test parameters for the calibration
15 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet figure 20. configuring the type of receiver test calibration to perform. figure 21. in the html test report the N5393D generates the appropriate graphical summary for each calibration parameter it configures. this gives you a traceable reference for how the tool setup and the calibration can save time when de-bugging the rx test setup. the N5393D utilizes the pci sigs own seasim simulation software to determine the target signal impairments and communicates those parameters to the instruments configured as part of the receiver test setup. the keysight dsa90000 series oscilloscope is used to capture traces from the jbert system setup, and that information is used by seasim to set the calibration values of the bit error ratio tester setup. the N5393D utilizes the pci sigs own seasim simulation software to determine the target signal impairments and communicates those parameters to the instruments configured as part of the receiver test setup. the keysight dsa90000 series oscilloscope is used to capture traces from the jbert system setup, and that information is used by seasim to set the calibration values of the bit error ratio tester setup. the N5393D option 004 is provided to help automate the most rigorous step in receive testing, the calibration step. once the equipment is calibrated, the actual receiver stress test can be performed manually or by using additional automation tools provided by keysight and its partners. the n5393c-4fp covers automates only the calibration step. you can also reference the keysight application note on pcie 3.0 base spec receiver testing at: http://literature.cdn. keysight.com/litweb/5990-6599en.pdf for additional information. receiver stressed eye calibration (continued)
16 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet reference clock measurements infiniimax 1169a probe with e2678a socket adapter attached to clb note 2pf capacitors added to clb to create refclk compliance load as per spec figure 22. the N5393D software includes important tests for the reference clock of your pci express system. this signal can be probed using the keysight infiniimax 1169a probes in conjunction with the pci-sigs compliance load board. reference clock test connection using clb2 figure 23. this shows the clb2 inserted into the cbb2 test fixture, representing the setup required to test add-in cards. the pci express 1.0a specification failed to specify the input bandwidth the reference clock receiver or phase jitter of the reference clock itself. this is important because jitter that lies within the loop bandwidth the receiver pll for the reference clock will transfer onto the high speed data lines. this hole in the pci express specification was corrected in the 1.1 update. the N5393D includes powerful reference clock evaluation tools including phase jitter. the pcie 1.1 specification calls for a very specific phase jitter filter that focuses the measurement on the jitter that lies between 1.5 and 22 - m hz. the filter also amplifies the jitter 3 db (peaking) within this region. the keysight N5393D includes proprietary filtering software (patent pending) that exactly implements the filters specified in the pci express specification. the N5393D also includes reference clock tests based on the pcie 2.0 and 3.0 specification. utilizing keysights infiniimax 1169a high performance differential probes, or direct cabled connections, you can measure your reference clock using the pci-sigs compliance load board or custom test fixture. C reference clock tests C phase jitter C rising edge rate C falling edge rate C differential input high voltage C differential input low voltage C average clock period C duty cycle
17 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet if your device fails a test, you need to determine how it failed. to use the pci express electrical test software, you must install keysights high-speed serial data analysis software, which provides you with several powerful debugging tools. the 8b/10b decoding feature lets you identify data-dependent errors that result in eye mask violations caused by inter-symbol interference (isi). you can perform 8b/10b decoding to capture and display serial data synchronized with the analog view of a serial data stream (for pcie 1.x and 2.x). powerful debugging aids figure 24. the 8b/10b decoded symbol information is shown below the appropriate portion of a pci express signal using the e2688a software. use the 10-bit code display to validate your compliance pattern conforms to the pci express standard make sure your compliance pattern has the proper disparity (k28.5-, d21.5, k28.5+, d10.2) using the e2688a serial data analysis tool you can test for illegal characters in your compliance pattern. you can also use the mask test feature to identify the specific digital patterns that caused a specific failure in the eye diagram when testing under the 1.1 specification (using a first order pll). for 2.0 testing you can use a first or second order pll for clock recovery and apply a tie brick wall filter (included with the e2688a series data analysis package) to achieve a proper clock filtering. figure 25. check for illegal characters in the compliance pattern (such as skps) using the e2688a serial data analysis tool. problems with early silicon still persist with new pci express devices. make sure yours isnt one of them. skp characters are not allowed in the compliance pattern.
18 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet powerful debugging aids (continued) figure 27. the e2688a allows you to show the specific waveform that caused an eye diagram failure. figure 26. this eye fails after 658k uis are analyzed here you see the specific waveform (and 10-bit code) that caused the eye failure
19 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet compliance test fxture description cbb 3,shrpsoldfhdhrdgirhl3,shdggl cards clb 3,shrpsoldfh/rdgrdgirhl3,sh sodirp cbb2 h3,shrpsoldfhdhrdgirhl3,sh add-in cards clb2 h3,shrpsoldfh/rdgrdgirhl3,sh sodirp cbb3 h3,shrpsoldfhdhrdgirhl3,sh add-in cards clb3 h3,shrpsoldfh/rdgrdgirhl3,sh sodirp pci express bandwidth requirements by data rate for transmitter measurements data rate minimum bandwidth required minimum sample rate 2.5 gt/s 6 ghz 20 gsa/s 5 gt/s 12 ghz 40 gs/s 8 gt/s 12 ghz 40 gs/s pci express sample rate requirements for reference clock measurements pcie standard minimum sample rate 1.1 20 gsa/s 2.x 20 gsa/s 3.x 20 gsa/s measurement requirements the pci express electrical performance validation and compliance software requires the e2688a high-speed serial data analysis software, one of the pci-sig approved compliance test fixtures (cbb or clb), and at least two sma cables or infiniimax active differential probes. the N5393D optionally requires the infiniisim waveform transformation toolset to enable to de-embedding or de-convolving of test fixture and cable losses based on user supplied s-parameter descriptions of these structures. some of the measurements cannot be made with the pci-sig compliance test fixtures and may require you to build or acquire a custom test board, assembly, or other test fixture. to purchase the pci express compliance test fixtures, consult the pci-sig web site and select the pci-sig specification order form link at: bandwidth requirements for pci express pci express operates at 2.5 gt/s, 5 gt/s and 8 gt/s. below are two tables that provide guidelines on the minimum bandwidth and sample rate required for pci express transmitter measurements. in addition to transmitter measurements, phase jitter measurements of the pcie 100 mhz reference clock also call for a minimum sample rate used to measure the clock as is also shown below. use this information to help you select the proper oscilloscope for your specific requirements.
20 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet table 2. recommended test accessories model number description add-in card testing psoldddggip www.pcisig.com/specifcations/ordering_information ) 15442a r60fdeoh 2h3srhsso 2hsrhssoordgirhodlr 1810-0118 6l#hpldr system motherboard testing psoldddggip www.pcisig.com/specifcations/ordering_information ) 15442a r60fdeoh 1134a or 1169a ,oll0dsrehlrfnhhgsrehdgdsh rldoh60dgdship 1810-0118 6l#hpldr semiconductor device testing customer supplied custom test fxtures with sms 15442a r60fdeoh 1169a 2h,oll0dsrehlgliihhldoroghfrhflr optional (for all types of testing) solppi 11636b 3rhglylghr+ppifrhfr 1250-1159 hh60ppdgdsh 8493b rdldodhdrrgr+60frhfr 0dfhgfdeohsdlrfplf60ppfdeohsrsddlrghodlls 1810-0118 60p#hpldlr recommended test accessories to complete your test setup, keysight provides a wide range of cables, adapters, terminations, etc. note: while the pci-sig does supply gen2 test fixtures for motherboard and add-in card testing, you will need to obtain smp cables, adapters and terminators from a vendor of your choice as the sig does not supply them.
21 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet assertion no. description keysight pci express sigtest transmitter tests phy.3.1#26 dc common mode voltage y n phy.3.2#1 de-emphasis on multiple bits same polarity in succession y n phy.3.2#2 transition bit voltage y n phy.3.3#1 transmitter eye diagram y n phy.3.3#2 unit interval without ssc variations y n phy.3.3#3 minimum d+/d- output rise/fall time y n phy.3.3#4 jitter median to max deviation y n phy.3.3#5 maximum rms ac common mode voltage y n phy.3.3#9 minimum eye width y n 5hfhlyhh phy.3.4#1 minimum receiver eye diagram y 1 n phy.3.4#2 ac peak common mode input voltage y 1 n phy.3.4#6 jitter median to max deviation input y 1 n system board (connector) tests em.4#4 minimum jitter y y em.4#20 transmitter path eye diagram y y 5hihhfhforfnfrhfrh phy.3.3#2 phase jitter y n/a 1 phy.3.3#1 rising edge rate y n/a phy.3.3#1 falling edge rate y n/a phy.3.3#4 differential input high voltage y n/a phy.3.3#4 differential input low voltage y n/a phy.3.3#9 average clock period y n/a phy.3.2#2 duty cycle y n/a add-in card (connector) tests em.4#13 minimum jitter y y em.4#19 transmitter path eye diagram y y 1. receiver tests provided by the keysight pci express software are listed under the pcie 1.x or 2.0 test tabs do not validate the receivers tolerance or ability to correctly receive data. they validate the signal at the receiver against specified tolerances. tests performed the pci express electrical performance validation and compliance software performs the following tests as per the pci express 1.0a and 1.1 electrical specifications for add-in cards and motherboard systems as documented in section 4 of the base specification (phy) and section 4 of the card electromechanical specification (em). for reference, the tests performed by the sigtest application are also noted. for gen2 testing coverage, the pci-sig decided not to create checklist, as was done for gen1. for test coverage refer to section 4.7.2. table 4-8 of the pci express 2.0 card electromechanical specification. for pci express 3.0, test coverage includes items listed on table 4-18 under section 4.3.3 of the pci express 3.0 base specification.
22 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet ordering information pcie switch matrix support license type infniium z-series infniium s-series infniium 90000 series fixed dfrldoohg 13 13 1 2slr 8hldoohg 13 13 1 11/ ordl dsrdeoh 13 13 1 13 6hyhedhg 1 pcie 3.0 base spec receiver test calibration license type infniium z-series infniium s-series infniium 90000 series fixed dfrldoohg N5393D-4fp 8hldoohg N5393D-4fp N5393D-4nl ordl dsrdeoh N5393D-4tp N5393D-4tp 6hyhedhg pcie 3.x transmitter testing license type infniium z-series infniium s-series infniium 90000 series fixed dfrldoohg N5393D-1fp option 044 8hldoohg N5393D-1fp N5393D-1nl ordl dsrdeoh N5393D-1tp N5393D-1tp 6hyhedhg n5435a-040 upgrade to pcie 3.0 transmitter testing license type infniium z-series infniium s-series infniium 90000 series fixed dfrldoohg 8hldoohg N5393D-2fp N5393D-2nl ordl dsrdeoh 6hyhedhg pci express 1.x and 2.x transmitter testing license type infniium z-series infniium s-series infniium 90000 series fixed dfrldoohg N5393D-3fp n5393e-3fp 1 option 022 8hldoohg N5393D-3fp n5393e-3fp 1 N5393D-3nl ordl dsrdeoh N5393D-3tp n5393e-3tp 1 N5393D-3tp 6hyhedhg n5435a-009 1. the s-series oscilloscope is limited to a maximum bandwidth of 8 ghz which is sufficient bandwidth only for 2.5 gt/s (pcie 1.x) transmitter measurements. transmitter measurements for 5gt/s (pcie 2.x) and 8 gts (pcie 3.x) require a minimum scope bandwidth of 12 ghz; however, pcie 2.x clock phase jitter measurements can be made with the s-series oscilloscope and are thus enabled with this license. 5gt/s transmitter measurements are not enabled on the s-series oscilloscope as a higher minimum bandwidth is required.
23 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet keysight oscilloscopes multiple form factors from 20 mhz to > 90 ghz | industry leading specs | powerful applications
24 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet www.axiestandard.org advancedtca ? extensions for instrumentation and test (axie) is an open standard that extends the advancedtca for general purpose and semiconductor test. the business that became keysight was a founding member of the axie consortium. atca ? , advancedtca ? , and the atca logo are registered us trademarks of the pci industrial computer manufacturers group. www.lxistandard.org lan extensions for instruments puts the power of ethernet and the web inside your test systems. the business that became keysight was a founding member of the lxi consortium. www.pxisa.org pci extensions for instrumentation (pxi) modular instrumentation delivers a rugged, pc-based high-performance measurement and automation system. learn more at www.keysight.com/find/software start with a 30-day free trial. www.keysight.com/find/free_trials download your next insight keysight software is downloadable expertise. from first simulation through first customer shipment, we deliver the tools your team needs to accelerate from data to information to actionable insight. C electronic design automation (eda) software C application software C programming environments C productivity software
25 | keysight | N5393D pci express ? 3.0 (gen3) software for infiniium oscilloscopes - data sheet this information is subject to change without notice. ? keysight technologies, 2014 - 2016 published in usa, august 15, 2016 5991-4756en www.keysight.com for more information on keysight technologies products, applications or services, please contact your local keysight office. the complete list is available at: www.keysight.com/find/contactus americas canada (877) 894 4414 brazil 55 11 3351 7010 mexico 001 800 254 2440 united states (800) 829 4444 asia pacifc australia 1 800 629 485 china 800 810 0189 hong kong 800 938 693 india 1 800 11 2626 japan 0120 (421) 345 korea 080 769 0800 malaysia 1 800 888 848 singapore 1 800 375 8100 taiwan 0800 047 866 other ap countries (65) 6375 8100 europe & middle east austria 0800 001122 belgium 0800 58580 finland 0800 523252 france 0805 980333 germany 0800 6270999 ireland 1800 832700 israel 1 809 343051 italy 800 599100 luxembourg +32 800 58580 netherlands 0800 0233200 russia 8800 5009286 spain 800 000154 sweden 0200 882255 switzerland 0800 805353 opt. 1 (de) opt. 2 (fr) opt. 3 (it) united kingdom 0800 0260637 for other unlisted countries: www.keysight.com/find/contactus (bp-06-08-16) dekra certified iso9001 quality management system www.keysight.com/go/quality keysight technologies, inc. dekra certified iso 9001:2015 quality management system mykeysight www.keysight.com/find/mykeysight a personalized view into the information most relevant to you. keysight infoline www.keysight.com/find/infoline keysights insight to best in class information management. free access to your keysight equipment company reports and e-library. keysight services keysight services www.keysight.com/find/service our deep offering in design, test, and measurement services deploys an industry-leading array of people, processes, and tools. the result? we help you implement new technologies and engineer improved processes that lower costs. three-year warranty www.keysight.com/find/threeyearwarranty keysights committed to superior product quality and lower total cost of ownership. keysight is the only test and measurement company with three-year warranty standard on all instruments, worldwide. and, we provide a one-year warranty on many accessories, calibration devices, systems and custom products. keysight assurance plans www.keysight.com/find/assuranceplans up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. keysight channel partners www.keysight.com/find/channelpartners get the best of both worlds: keysights measurement expertise and product breadth, combined with channel partner convenience. pci-sig ? , pcie ? and the pci express ? are us registered trademarks and/or service marks of pci-sig. www.keysight.com/find/N5393D evolving our unique combination of hardware, software, support, and people can help you reach your next breakthrough. we are unlocking the future of technology. from hewlett-packard to agilent to keysight


▲Up To Search▲   

 
Price & Availability of N5393D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X