  tel :805-968-0782 / 800-350-2727 | fax: 805-968-3154 / 800-960-2726 7230 hollister ave., goleta, ca 93117 | www.beisensors.com specification no. 02097-001 rev . 06/11 the broadcaster accepts standard incremental encode r inputs, (two channels in quadrature plus an index and complements) and can broadcast up to four encoder signals to four independent devices. each of the broadcast signals is optically isolated eliminating ground loops. this compact package also allows for signal processing options, such as anti-dither filt er, integer countdown or pulse and direction outputs, to be incorporated into each of the four broadcast signals independently. t he broadcaster is ideal for driving multiple receivers from a single encoder in applications like electronic line shafting or synchronization of multiple devices to a single operation. the module accepts signals of 5, 12-15 and 24 vdc and provides three output options: v out = v in , v out = 5 v or npn open collector. the compact package mount s to standard en 50 022 35mm x 7.5mm din rail and is 142mm wide, 78mm deep and 45mm above the din rail. a 155mm section of din rail is includ ed. broadcaster ordering op tions for assistance, call 800-350-2727 (asap) use this diagram to construct your model number. exam p le: bx-5-ic/v-ic/v-p2/5-p2/5 5 ic/v o utput voltage from encoder: 5, 15, 24 bx broadcaster output voltage/type: /v = multivoltage 5-28 volts in, v out = v in /5 = multivoltage 5-28 volts in, v out = 5v regulated /oc = multivoltage 5-28 volts in, vout = open collector ic/v choose one for each channel: db = divide by, selectable integer value 1-256 ad= anti-dither px = pulse up/down where x = multiple, either 1, 2, or 4 pxd = pulse direction where x = multiple, either 1, 2, or 4 ic = isolation circuit (standard) function for channel 2 function for channel 1 function for channel 3 function for channel 4 p2/5 p2/5 bei electronic modules encoder signal broadcaster feat u re s ? broadcasts signals from a single encoder to four independent receivers ? signal processing modules (pulse converter, integer countdown, anti-dither) can be added to each output for additional capabilities ? accepts all standard input voltages and types: single ended, differential and open collector ? signals are optically isolated for high noise immunity ? compact package saves installation costs
tel -2726 sensors.com :805-968-0782 / 800-350-2727 | fax: 805-968-3154 / 800-960 7230 hollister ave., goleta, ca 93117 | www.bei specification no. 02097-001 rev . 06/11 a a a/ a/ b b b/ b/ z z z/ z/ +v 0v a a / b b / z / z +v 0v reg v s 0v o encoder differential line driver out ptical isolator p ut figure 1 standard connection to optical isolator module single ended line dr iver (see figure 2) differential line driver (see figure 1) aa a/ b b b/ z z z/ +v 0v a a / b b/ z/ z +v 0v reg v s 0v o encoder sin ptical isolator g le ended line driver out p ut figure 2 connection diagram single ended line driver encoder supply open collector with or without internal pull- up resistors (see figure 3) encoder signal from 5 vdc to 24 vdc (must specify the voltage when ordering) encoder signals from 5 vdc to 24 vdc (must specify the voltage when ordering) conn e ct broadcaster a to optical isolator module input channel a, b to b and z to z. connect the a/, b/, and z/ inputs of the optical isolator to circuit common of the encoder supply. single ended operation is limited to shorter cable runs and is more susce p tible to noise. this is the preferred type of enco der o utput as it has the best noise immunity. connect each encoder signal to its like input (a to a, a/ to a/, etc ) . encoder npn (sinking) outputs. connect encoder output a to optical isolator module input a/, b to b/ and z to z/. connect the a, b, and z inputs of the broadcaster to the positive encoder supply line. this connection results in a logic inversion within the broadcaster module. to compensate for the logic reversal, swap a for a/, b for b/, and z for z/ at the broadcaster outputs. connection instructions (for isolated circuit and anti-dither functions) broadcaster module broadcaster broadcaster a o r a/ a a/ b or b/ b b/ z or z/ z z/ +v 0v a a / b b/ z/ z +v 0v reg v s 0v encoder o o ptical isolator p en collector out p ut figure 3 connect open coll le ion diagram ector to optical modu opt lation p y ical regu owe r suppl aux 5v broadcaster broadcaster +v +v encode r +v
tel :805-968-0782 / 800-350-2727 | fax: 805-968-3154 / 800-960-2726 7230 hollister ave., goleta, ca 93117 | www.beisensors.com specification no. 02097-001 rev. 06/11 encoder side driver side pin description notes + v power supply 5 ? 28 vdc 125 ma + load current typ. 0 v power supply common supply lines between driver sections are not connected. driver must be powered in order to produce an output. supply voltage need not be the same for different driver sections. en output enable hi = output active, lo = high impedance internal pull-up to v+ a, a/ channel a outputs b, b/ channel b outputs z, z/ channel z outputs output levels consistent with driver type and supply voltage (v/v outputs). pin description notes a, a/ channel a inputs b, b/ channel b inputs z, z/ channel z inputs input levels consistent with specified value in model number (5 v, 15 v, 24 v). signal input current 25 ma nom. see bei oim applications guide for single ended and open collector connection diagrams t1, t2, t3 uncommitted terminals non-committed terminals. provided for use as connection points for encoder power. broadcaster block diagram termination pinouts
tel :805-968-0782 / 800-350-2727 | fax: 805-968-3154 / 800-960-2726 7230 hollister ave., goleta, ca 93117 | www.beisensors.com specification no. 02097-001 rev. 06/11 additional modules and accessories power supply with a wide range of acceptable input voltages (ac and dc) this din rail mountable power supply is usable in virtually all industrial applications worldwide. it has built in surge protection to reduce faults due to transients and it has 100% reserve capacity fo r startup and overload conditions. cable and cable assemblies cable reels for your own custom wiring requirements or cable assemblies are available, using high quality custom bei standard cable consisting of four, low capacitance shielded twisted pairs wi th an overall shield, extra large conductors for power, and signal ground; all within an abrasion-resistant pvc jacket. cable reels 100 ft. reel part no. 37048-003-100 500 ft. reel part no. 37048-003-500 cable assemblies part nos. for ms3106f14s-6s mating connector 10 ft. # 31186-1410 20 ft. # 31186-1420 30ft. # 31186-1430 part nos. for ms3106f16s-1s mating connector 10 ft. # 31186-1610 20 ft. # 31186-1620 30ft. # 31186-1630 part nos. for ms3106f18s-1s mating connector 10 ft. # 31186-1810 20 ft. # 31186-1820 30ft. # 31186-1830


▲Up To Search▲   

 
Price & Availability of BX-5-ICV-ICV-P25-P25

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X