adn-c series 3-phase 120-960 watts total power: 120-960 watts input voltage: 380-480 vac # outputs: single special features ? slim form factor ? five year warranty ? high effciency up to 94% ? full power at 60 c ? power boost? ? industrial grade design ? metal case ? mtbf > 500,000h ? adjustable output ? overvoltage protection with auto recovery ? continuous short circuit and overload protection ? new visual diagnostic led ? three status leds ? input ? output ? alarm ? dc ok relay ? parallel operation capability ? screw terminal connections ? rohs compliant ? no tools required for mounting safety ? ul508, culus listed ? ul 60950-1, curus 2 nd edition ? iec60950-1 2 nd edition ? class i, div 2 hazardous locations ? ip20 ? ce electrical specifcations input nominal voltage 380 - 480 vac ac input range 320 - 540 vac dc input range 450 - 760 vdc for adn5, adn10 & adn20 frequency 50 - 60 hz effciency up to 94% pfc active power factor correction for adn20 & adn40; meet en61000-3-2 class a phase input adn5 and adn10 will operate with single phase input at 100% load derate to 75% and 50% for adn20 and adn40 respectively under loss of 1 phase; units will shut down if thermal threshold is exceeded under this condition output nominal voltage 24 v (24.0 - 28.0 vdc adj.) hold-up time > 20 ms for adn5, adn10 & adn20; > 15 ms for adn40 voltage regulation < 2% overall ripple < 100 mvpp current limit powerboost? peak current 2x nominal current for < 2 sec for adn5 & adn10; 1.5x nominal current for 4 seconds minimum while holding voltage > 20 vdc for adn20 & adn40 parallel operation single or parallel operation selectable via front switch. for redundant operation use of external diode module is preferred; adn40 uses active paralleling power back immunity < 35 v overvoltage protection > 30.5 vdc, but < 33 vdc, auto recovery data sheet power
adn-c series 3-phase data sheet general specifcations emc emissions en61000-6-3:2001, class b en55011, en55022 radiated and conducted including annex. a, en61000-3-2 emc immunity en61000-6-1:2001, en61000-6-2:2001, en61000-4-2 level 4, en61000-4-3 level 3, en61000-4-6 level 3, en61000-4-4 level 4 input and level 3 output. en61000-4-5 isolation class 4, en61000-4-11, semi f47 sag immunity warranty 5 years general protection safety protected against continuous short-circuit, overload, open-circuit. protection class 1 (iec536), degree of protection ip20 (iec 60529) safe low voltage: selv (acc. en60950) status indicators visual: 3 status leds (input, output, alarm) relay: ssr or dry relay contact, signal octive when vout = 18.5 vdc + 5% led diagnostics led ok loss of ac low ac no dc high load overload hot too hot input green --- yellow green green green green green output green --- green --- yellow yellow green --- alarm --- --- --- red yellow red yellow yellow environmental specifcations storage/shipment -40 c to + 85 c operation (convection) full load -25 c to + 60 c derate to 50% load at +70 c up to 50% load permissable with horizontal or on top mounting orientation humidity < 90% rh, non-condensingl iec 60068-2-2, 68-2-3 other features fusing input externally fused; output not fused, output is capable of providing high currents (powerboost) for motor load startup mounting orientation standard: vertical, optional: horizontal or on top simple snap-on to din ts35/7.5 or ts35/15 rail system ventilation normal convection, no fan required cooling spacing adn5: 15 mm in front, 25 mm above and below adn10: 15 mm in front, 25 mm above and below adn20: 25 mm in front, left and right; 70 mm above and below adn40: 15 mm in front, 70 mm above and below, 25 mm left and rightt connections input: screw terminals, connector size range: 16-10 awg (1.5-6 mm 2 ) for solid conductors output: connector size range: 16-10 awg (1.5-6 mm 2 ) for adn5, adn10 and adn20 solid conductors; 6-7 awg for adn40
adn-c series 3-phase data sheet adn-c series 3-phase ds 03aug2015 ordering information model number power input voltage weight current effciency case type mtbf adn5-24-3pm-c 120 w 320 - 540 vac 450 - 760 vdc 1.15 lbs (520 g) 5 a @ 24 vdc 85.0% metal > 500,000 hours nominal voltage, full load, tamb=25 o c adn10-24-3pm-c 240 w 1.54 lbs (700 g) 10 a @ 24 vdc 91.2% ADN20-24-3PM-C 480 w 2.8 lbs (1300 g) 20 a @ 24 vdc 93.0% adn40-24-3pm-c 960 w 320 - 540 vac 5.3 lbs (2400 g) 40 a @ 24 vdc 94.0% dimensions height width depth adn5-24-3pm-c 4.85 in (123 mm) 1.97 in (50 mm) 4.36 (111 mm) adn10-24-3pm-c 4.85 in (123 mm) 2.36 in (60 mm) 4.36 (111 mm) ADN20-24-3PM-C 4.85 in (123 mm) 3.34 in (85 mm) 4.68 (119 mm) adn40-24-3pm-c 4.85 in (123 mm) 7.09 in (180 mm) 4.85 in (123 mm) mechanical drawing 380 - 480 v3; 3w + pe 50/60 hz 0.9 a / phase us listed ADN20-24-3PM-C parallel single c l u l2 l1 24 vd c/ 20 a + + - - ok w d h input alarm output 24 - 28 vd c l3 w d h l1 l2 + l3 + - - 24- 28v o k o v e r l o a d f u s e m o d e c o n t i n u o u s m o d e 3ph 380/500 vac 1.7/1.5a/phase 50/60 hz input : s i n g l e u s e p a r a l l e l u s e r e s e t f u s e m o d e us listed u c l adn40-24-3pm-c 0 v u q v u 7 % $ " & |