revised 11/6/2013 www.phihong.com 80w constant voltage led driver pda080 series for outdoor lighting features ? high efficiency ? ip67 - waterproof, potted ? class 2 per ul1310 ? wide operating temperature range ? 5 year warranty ? brownout/brownout recovery ? ovp, short and open circuit protection ? 120v-277v ac operation applications ? general lighting ? outdoor lighting ? street lighting ? architectural lighting safety approvals ? ce ? cul/ul mechanical characteristics ? length: 241mm (9.5in) ? height: 30.5mm (1.2in) ? width: 43mm (1.7in) ? weight: 750g (1.65lbs) output specifications note (1): x is b for non-dimming or w for 0-10v dimming note (2): output power derated to 72w when input voltage is <100vac phihong is not responsible for any error, and reserves the right to make changes without notice. please visit our website at ww w.phihong.com for the most up-to-date specifications and contact information. model (1) output voltage output current output power (2) min. typ. max. PDA080X-48VG 48v 0a 1.67a 1.70a 80w
pda080x characteristics www.phihong.com input: ac input voltage rating 90vac to 304vac ac input frequency 47~63hz maximum input current 2a leakage current 0.5ma maximum at 230vac input inrush current 20a output: power factor 0.9 at nominal ripple and noise <7% (p-p) efficiency (target) 87% at 277vac 85% at 120vac turn-on delay time 0.5s maximum at nominal ac power on environmental: temperature operation -40 to +60c non-operation -40 to +85c operating humidity 10 to 95% case temperature 80c maximum warranty 5 years dimming function: (w models) dimming control 0-10vdc dimming output to load pwm at 500hz dimming grounding dim(-) and vout(-) must never be connected together to ensure proper operation and isolation requirements emc en55015/cispr 15, fcc 47 cfr part 15/18, class a immunity iec61000-4-2 iec61000-4-3 iec61000-4-4 iec61000-4-5* iec61000-4-6 iec61000-4-8 iec61000-4-11 iec61000-3-2 class c *surge differential mode: 2.0kv, common mode: 4.0kv ring wave surge (ansi c62.41.2 cat a) differential mode: 4.0kv common mode: 6.0kv input over current protection the input power line will be fused with a 3.15a fuse short-circuit protection the psu will withstand a short circuit across the outputs without damage open circuit protection once the circuit is opened, the output voltage should be less than 120% at nominal ac input conditions dielectric withstand (hi-pot) test primary to secondary: 4242vdc for 1 minute, 5ma insulation resistance primary to secondary: >5m ohm 500vdc, 1 minute design life 50k hours at full power, ambient 50c and tcase dimension diagram unit:mm www.phihong.com
|