february 2007 ca08102001e for more information visit: www.eaton.com 33-79 nema contactors & starters 33 freedom catalog number selection catalog number selection table 33-91. freedom catalog numbering system for contactor only orders, add b to end of catalog number if nema size 00 C 2, 6. 3e, 4e feature set only. uses ct with c396 45 mm olr, 3e, 4e feature set only. not required. nema sizes 00 and 0 only. nema sizes 00 and 0 only. sizes 1 C 8 are 24/60 only. device type a = starter c = contactor contactor frame size nema size continuous amp rating a = b = d = g = k = n = s = t = u = v = 00 0 1 2 3 4 5 6 7 8 9 18 27 45 90 135 270 540 810 1215 a n 1 4 a n 0 a 3 e 0 0 5 ac coil suffix suffix coil volts and hertz a = b = c = d = 120/60 or 110/50 240/60 or 220/50 480/60 or 440/50 600/60 or 550/50 e = h = j = k = 208/60 277/60 208 C 240/60 240/50 l = n = t = u = 380 C 415/50 550/50 24/60, 24/50 24/50 v = w = y = 32/50 48/60 48/50 standard e = iec n = nema device assembly configuration 70 = multi-speed 1 = non-reversing 5 = reversing olr type 4 = starter w/c396 electronic overload 5 = contactor only no overload relay 6 = starter w/c306 bi-metal olr 7 = starter w/c316 bi-metal olr 8 = starter w/ it. ssolr c396 electronic overload fla range (fnvr & fvr only) frame a nema size 00 p05 = 0.1 C 0.5a 002 = 0.4 C 2.0a 005 = 1.0 C 5.0a 008 = 1.6 C 8.0a frame g nema size 2 008 = 1.6 C 8.0a 032 = 6.4 C 32a 045 = 9.0 C 45a frame b nema size 0 p05 = 0.1 C 0.5a 002 = 0.4 C 2.0a 005 = 1.0 C 5.0a 008 = 1.6 C 8.0a 032 = 6.4 C 32a frame k nema size 3 110 = 22 C 110a frame n nema size 4 150 = 30 C 150a frame s nema size 5 300 = 60 C 300a frame d nema size 1 p05 = 0.1 C 0.5a 002 = 0.4 C 2.0a 005 = 1.0 C 5.0a 008 = 1.6 C 8.0a 032 = 6.4 C 32a frame t nema size 6 600 = 120 C 600a frame u nema size 7 10c = 200 C 1000a frame v nema size 8 15c = 300 C 1500a c396 electronic olr designation (fvnr & fvr only) 3e = standard c396 olr, sel reset, sel class c306 bi-metallic olr designation c = b = n/r = b = c = b = nema size 00, 0 nema size 1, 2 nema size 3, 4 nema size 5 nema size 6 nema size 7, 8 nema enclosure n = open for starters starter mounting option 0 = v = horizontal vertical for contactors only 2 = 3 = 4 = 5 = 2-pole 3-pole 4-pole 5-pole
february 2007 ca08102001e for more information visit: www.eaton.com 33-85 nema contactors & starters 33 freedom starters 3-phase non-reversing and reversing, full voltage, bi-metallic overload product selection when ordering supply catalog number heater pack number (see selection table, pages 33-117 C 33-118 ) or full load current. table 33-101. type an16/an56 nema manual or automatic reset overload relay non-reversing and reversing note: starter catalog numbers do not include heater packs. select one carton of three heater packs. heater pack selection, pages 33-117 C 33-118 . underscore (_) indicates coil suf?x required, see table 33-102 . maximum horsepower rating of starters for 380v 50 hz applications: the service-limit current ratings represent the maximum rms current, in amperes, which the controller shall be permitted to car ry for protracted periods in normal service. at service-limit current ratings, temperature rises shall be permitted to exceed those obtained by testing t he controller at its continuous current rating. the current rating of overload relays or trip current of other motor protective devices used shall n ot exceed the service-limit current rating of the controller. common control. for separate 120v control, insert letter d in 7th position of listed catalog number. example: an56vn d 0cb. magnet coils ac or dc starter coils listed in this section also have a 50 hz rating as shown in the adjacent table. select required starter by catalog number and replace the magnet coil alpha designation in the catalog number (_) with the proper code suf?x from the adjacent table. for sizes 00 C 2 and 5 C 8, the magnet coil alpha designation will be the next to last digit of the listed catalog num- ber. example: for a 380v, 50 hz coil, change an16bn0 _ c to an16bn0 l c. for all other sizes, the magnet coil alpha designation will be the last digit of the listed catalog number. for dc magnet coils , see accessories, pages 33-98 C 33-99 . table 33-102. ac suf?x code nema sizes 00 and 0 only. nema sizes 00 and 0 only. sizes 1 C 8 are 24/60 only. nema size continuous ampere rating service-limit current rating (amperes) maximum ul horsepower 3-pole non-reversing 3-pole reversing vertical reversing price u.s. $ 1-phase 3-phase 115v 230v 208v 240v 480v 600v catalog number price u.s. $ catalog number catalog number 00 9 11 1/3 1 1-1/2 1-1/2 2 2 an16an0_c an56an0_c 0 18 21 12 3355 an16bn0_c an56bn0_c an56bnv0_ 1 27 32 2 3 7-1/2 7-1/2 10 10 an16dn0_b an56dn0_b an56dnv0_ 2 45 52 3 7-1/2 10 15 25 25 an16gn0_b an56gn0_b an56gnv0_ 3 90 104 25 30 50 50 an16kn0_ an56kn0_ an56knv0_ 4 135 156 40 50 100 100 an16nn0_ an56nn0_ an56nnv0_ 5 270 311 75 100 200 200 an16sn0_b an56sn0_b 6 540 621 150 200 400 400 an16tn0_c an56tn0_c 7 810 932 200 300 600 600 an16un0_b an56un0_b 8 1215 1400 400 450 900 900 an16vn0_b an56vn0_b nema size 00 01234 5678 horsepower 1-1/2 5 10 25 50 75 150 300 600 900 size 0 non-reversing starter size 1 reversing starter size 3 vertical reversing starter nema size 0 cat. no. an56bn0ac coil volts and hertz code suf?x 120/60 or 110/50 240/60 or 220/50 480/60 or 440/50 600/60 or 550/50 a b c d 208/60 277/60 208 C 240/60 240/50 e h j k 380 C 415/50 550/50 24/60, 24/50 24/50 l n t u 32/50 48/60 48/50 v w y technical data. . . . . . . . . . pages 33-89 C 33-91 overload relay . . . . . . . . . page 33-113 dimensions . . . . . . . . . . . . pages 33-106 C 33-108 special modi?cations . . . page 33-100 accessories . . . . . . . . . . . . pages 33-92 C 33-100 heater packs . . . . . . . . . . . pages 33-117 C 33-118 discount symbol . . . . . . . . 1cd1
february 2007 ca08102001e for more information visit: www.eaton.com 33-117 nema contactors & starters 33 freedom relays thermal overload product selection table 33-168. c306 thermal overload relays nema sizes 5 C 8 use the 32a overload in conjunction with cts. series b overload relays have load lugs built into relay base and will only accept series b heater packs. these relays can be d irectly attached to contactor or they can be din rail or panel mounted using adapter on page 33-115 . these relays can be panel mounted only. table 33-169. c306 thermal overload relays overload relay assembled with mounting adapter for din rail or panel mount. panel mount only. nema sizes 5 C 8 use the 32a overload in conjunction with cts. heater pack selection heater packs h2001b to h2017b and h2101b to h2117b are to be used only with series b overload relays catalog numbers c306dn3b (part no. 10-7016) and c306gn3b (part no. 10-7020). the load lugs are built into the overload relay base to allow load wiring prior to heater pack installa- tion. the previous heater design had integral load lugs. the series b heater packs are electrically equivalent to the previous heater design. heaters h2018-3 to h2024-3 have not changed. table 33-170. starters with series b overload relays note: the series of a starter is the last digit of the listed catalog number. example: an16dn0a b . for use with freedom series contactors maximum ampere rating number of poles open type nema 1 enclosed nema size catalog number price u.s. $ catalog number price u.s. $ 00, 0 1, 2 3 4 5 C 8 32 75 105 144 3 3 3 3 c306dn3b c306gn3b c306kn3 c306nn3 c306dg3b c306gg3b 75a overload cat. no. c306gn3b 75a overload cat. no. c306gt3b 32a overload cat. no. c306dt3b 32a overload cat. no. c306dn3b for stand-alone applications maximum ampere rating number of poles open type nema size catalog number price u.s. $ 00, 0, 1 1 3 4 5 C 8 32 75 105 144 3 3 3 3 c306dt3b c306gt3b c306kn3 c306nn3 heater pack h2001b C h2017b heater pack h2101b C h2117b heater pack h2018 C h2024 nema an type iec ae type size series size series 00 C 0 1 C 2 5 6 7 C 8 c b b c b a C f g C k c b technical data . . . . . . . . page 33-114 dimensions . . . . . . . . . . . . page 33-116 replacement parts . . . . . pages 33-115 C 33-116 discount symbol . . . . . . . 1cd1c
february 2007 33-118 for more information visit: www.eaton.com ca08102001e nema contactors & starters 33 freedom relays thermal overload table 33-171. standard trip class 20 heater selection heater packs are shipped 3 to a carton. catalog numbers are for 3 heater packs. sizes 5 C 8 and iec p C z use the 32a overload relay with current transformers. table 33-172. fast trip class 10 heater selection heater packs are shipped 3 to a carton. catalog numbers are for 3 heater packs. sizes 5 C 8 and iec p C z use the 32a overload relay with current transformers. overload relay size motor full load ampere rating catalog number (includes 3 heater packs) price u.s. $ dial position abcd for use with nema sizes 00 C 0 series c, nema sizes 1 C 2 series b; iec sizes a C f series c, iec sizes g C k series b 32a or 75a .254 .375 .560 .814 1.20 .306 .452 .676 .983 1.45 .359 .530 .791 1.15 1.71 .411 .607 .907 1.32 1.96 h2001b-3 h2002b-3 h2003b-3 h2004b-3 h2005b-3 1.79 2.15 3.23 4.55 6.75 2.16 2.60 3.90 5.50 8.17 2.53 3.04 4.56 6.45 9.58 2.90 3.49 5.23 7.40 11.0 h2006b-3 h2007b-3 h2008b-3 h2009b-3 h2010b-3 9.14 14.0 18.7 23.5 10.8 16.9 22.7 28.5 12.4 19.9 26.7 33.5 14.0 22.8 30.7 38.5 h2011b-3 h2012b-3 h2013b-3 h2014b-3 for use with nema size 2, iec sizes g C k only series b 75a 29.0 39.6 53.9 34.0 45.5 60.9 39.1 51.5 67.9 44.1 57.4 74.9 h2015b-3 h2016b-3 h2017b-3 for use with nema sizes 3 C 4, iec sizes l C n only series a 105a or 144a 8.0 11.4 14.3 18.0 24.6 9.2 12.8 15.7 20.2 27.6 10.3 14.3 17.4 22.3 30.5 11.5 15.7 19.0 24.5 33.4 h2025-3 h2026-3 h2027-3 h2018-3 h2019-3 33.5 45.7 62.2 84.7 106.0 37.5 51.2 69.7 95.0 118.0 41.5 56.7 77.1 105.0 131.0 45.6 62.1 84.6 115.0 144.0 h2020-3 h2021-3 h2022-3 h2023-3 h2024-3 for use with size 5 starters series b and iec p, r and s with 300/5 ct 32a 49 72 107 129 194 59 87 130 156 234 69 103 152 182 274 79 118 174 209 h2004b-3 h2005b-3 h2006b-3 h2007b-3 h2008b-3 for use with size 6 starters only series b and iec t C v with 600/5 ct 32a 144 215 258 388 174 259 312 468 205 304 365 547 235 348 419 627 h2005b-3 h2006b-3 h2007b-3 h2008b-3 for use with size 7 starters only series b and iec w C x with 1000/5 ct 32a 163 240 358 430 646 197 290 432 520 780 230 342 506 608 912 264 392 580 698 h2004b-3 h2005b-3 h2006b-3 h2007b-3 h2008b-3 for use with size 8 starters only series b and iec z with 1500/5 ct 32a 244 360 537 645 969 295 435 648 780 1170 345 513 759 912 1368 396 588 870 1047 h2004b-3 h2005b-3 h2006b-3 h2007b-3 h2008b-3 overload relay size motor full load ampere rating catalog number (includes 3 heater packs) price u.s. $ dial position abcd for use with nema sizes 00 C 0 series c, nema sizes 1 C 2 series b; iec sizes a C f series c, iec sizes g C k series b 32a or 75a .260 .384 .570 .846 1.28 .313 .464 .688 1.02 1.55 .367 .543 .806 1.20 1.83 .420 .623 .924 1.37 2.10 h2101b-3 h2102b-3 h2103b-3 h2104b-3 h2105b-3 1.92 2.30 3.38 4.96 7.07 2.33 2.79 4.10 6.03 8.58 2.74 3.28 4.82 7.09 10.1 3.15 3.77 5.54 8.16 11.6 h2106b-3 h2107b-3 H2108B-3 h2109b-3 h2110b-3 9.60 14.4 18.7 23.5 11.2 17.5 21.8 27.3 12.8 20.7 25.0 31.0 14.4 23.8 28.1 34.8 h2111b-3 h2112b-3 h2113b-3 h2114b-3 for use with nema size 2, iec sizes g C k only series b 75a 28.3 36.6 53.8 32.6 42.3 60.8 37.0 48.1 67.9 41.3 53.8 74.9 h2115b-3 h2116b-3 h2117b-3 for use with size 5 starters only series b and iec p, r and s with 300/5 ct 32a 51 77 115 138 203 61 93 140 167 246 72 110 164 197 289 82 126 189 226 h2104b-3 h2105b-3 h2106b-3 h2107b-3 H2108B-3 for use with size 6 starters only series b and iec t C v with 600/5 ct 32a 154 230 276 406 186 280 335 492 220 329 394 578 252 378 452 h2105b-3 h2106b-3 h2107b-3 H2108B-3 for use with size 7 starters only series b and iec w C x with 1000/5 ct 32a 169 256 384 460 676 204 310 466 558 820 240 366 543 656 274 420 630 754 h2104b-3 h2105b-3 h2106b-3 h2107b-3 H2108B-3 for use with size 8 starters only series b and iec z with 1500/5 ct 32a 254 384 576 690 1014 306 465 699 837 1230 360 549 822 984 411 630 945 1131 h2104b-3 h2105b-3 h2106b-3 h2107b-3 H2108B-3 discount symbol . . . . . . . . . . . . . . . . . . . . . . . 1cd1c
|