  edition 12/2005 terminal description b request - to - exit input 1 e request - to - exit input 2 m common rex inputs r n/c contact door c c ommon t n/o contact door v1,v2 varist or st1 jumper for reset s,s tamper switch output notice de montage et dutilisation this device comes with a varistor. the varistor must be connected to the strike terminal (electromagnet) operated by the device. if this product works with many strikes, each of them should have a varistor. the varistor controls the overload produced by the strike coil self - effect. if you are using a shear lock ?electromagnetic lock, it is recommended to use a separate power supply than the one connected to the dg502u ! warning do not use a switching power supply because of the interference radiation that may disturb the reading of the badges ne pas utiliser dalimentation ? d?coupage ? cause de rayonnements parasites pouvant perturber la lecture des badges. p b 1 p b 2 c r t r c t s s b m e 1 2 3 4 5 6 12 v 12 1 2 3 4 5 6 7 8 9 ? 0 # rl1 rl2 12 3 st1 v1 s trike input voltage 12v ac/dc v m a g n e t v2 dg502 u /a dg502 u /p 2 - door controller 500 users
edition 12/2005 - 2 - 2 technical specifications input voltage 12 v ac/dc outputs 2 form c rela ys n/o and n/c 3a @ 125v tamper switch 500 m a @ 50 v ac/dc cardholders 500 badges master code 5 - digit master code inputs 2 rex inputs controller 12 - di git keypad with bui l t - in buzzer ( audible feedback) distance between the remote readers and the controller 60 cm minimum , 50 m eters maximum ( cable spec. 7 x 0.6 mm 2 ) default factory values master code: 12345 door release time : 1 second key - in keypad : 10 seconds enrollment unit : built - in reader in controller power consumption dg502 only : 160ma dg502 with 1 remote reader : 240ma dg502 with 2 remote readers : 320ma audible sound feedback 1 long beep validation of data in programming mode: mas ter code, proximity badge or time delay. or access code validated 2 short beeps accessing the programming mode or exit from the programming mode 4 short beeps badge not programmed (invalid badge) or incorrect master code or time delay entered visual led feedback led stand - by mode programming mode green door relay activated user location free red a larm activated user location orange p rogramm i n g mode orange flashing stand - by error data computing request - to - exit i nputs the two request - to - exit inputs pb1 and pb2 operate relay rl1 and rl2. the led turns on green when the relay is activated by one of the two inputs.
edition 12/2005 - 3 - 3 chang e the m aster c ode 1. enter the master code twice (for the first use the master code default value is 123 45). 2 beeps and the orange led lights on confirming that you are in programming mode. 2. enter *3 then the 5 - digit new master code. the led goes off during 1 second and an audible beep indicates that the new master code is memorised. 3. press # to exit from t he programming mode. 2 beeps confirm that you went back to the reading mode. 4 beeps indicate a data computing error. time outputs, enrolment reader and access level enter the master code twice (for the first use the master code default value is 1234 5). 2 beeps and the orange led lights on confirm the entry in programming mode. enrolment reader enter ? 0, then 00 to select the built - in reader of the controller as the enrolment unit . press ? 0, then 01 remote reader 1 as the enrollment unit . the led lig hts off during 1 second and an audible beep indicates the validation of the enrolment reader. in stand - by mode , if the enrolment reader is the controller built - in reader all the readers can be used but if the enrolment reader is the remote reader 1 then o nly the 2 remote reader can be used. t ime output rela y 1 enter ? 1, then the time relay in second: 01 equal 1 second up to 99 for 99 seconds. 00 corresponds to a latched output. the led lights off during 1 second and an audible beep indicates the vali dation of the time delay. t ime output relay 2 enter ? 2, then the time relay in second: 01 equal 1 second up to 99 for 99 seconds. 00 corresponds to a latched output. the led lights off during 1 second and an audible beep indicates the validation of th e time delay. a ccess level enter ? 4 , then 01 for door 1 and controller activates rela y 1 02 for door 2 activates rela y 2 03 door 1 and 2 activates rela y 1 2 the led lights off during 1 second and an audible beep indicates the validation of the access level . press # to exit from the programming mode. 2 beeps confirm that you returned to reading mode. 4 beeps indicate a data com puting error.
edition 12/2005 - 4 - 4 add a b adge the badges can be programmed by group according to the access level selected in menu *4. you can program a series of badges then change the access level in menu * 4 and program another se ries of badges . 1. enter the mas ter code twice ( for the first use the master code default value is 12345). 2 beeps and the orange led lights on to confirm that you have entered into the programming mode. 2. enter *4 and select the access level 01 o r 02 o r 03 one beep is emitted . 3. enter the u ser location ( 000 to 499). the led lights off during 1 second and one beep is emitted . 4. if the led turns gre e n , p resent a badge in front of the enrolment reader (built - in proximity reader or auxiliary reader#1) . the led lights off during 1 second and one be ep is emitted. the led lights on solid orange to confirm that the badge was programmed . 5. if the led turns red ( badge is already programmed in that user location ), delete the badge or select another user location . 6. to program a badge with the same access lev el repeat from step 3 7. to program a badge with a different access level repeat from step 2 press # to exit from the programming mode. 2 beeps confirm that you returned to reading mode. 4 beeps indicate a data computing error. delet e or r eplac e a badge 1. enter the master code twice ( for the first use the master code default value is 12345). 2 beeps and the orange led lights on to confirm that you have entered into the programming mode . 2. enter *4 and then select the access level 01 o r 02 o r 03 o n e b ee p is em itted . 3. enter the user location from 000 to 499 to delete . the led lights off during 1 second and 1 b ee p is emitted . 4. if the led lights on in red it indicates that a badge is programmed at that user location . 5. press ? twice to delete the badge . the led lights off during 1 second and 1 beep is emitted . 6. the led lights on in green to confirm that the badge was deleted . 7. press # to exit from programming . o r 8. pr esent a new badge in front of the enrolment unit . the led lights off during 1 second and 1 beep is emitte d . 9. the led lights on in orange to confirm that the new badge was programmed . 10. press # to exit from programming . 2 beeps confirm that you returned to reading mode. re set of master code and badges to f actory d efault v alues 1. place st1 jumper on, 2 - 3 position . 2. the led flashes in green during 5 seconds. one beep confirm s that the master code is restored to its fa ctory default setting 12345. the led starts then flashing in red . 3. remove the jumper from 2 - 3 position to go back to stand - by mode . o r 4. keep the jumper on 2 - 3 position to delete all the badges from the controller . 5. the red led flashes during 5 seconds then turns to solid red during the rest of the reset . 6. once all the badges have been deleted, the led lights off . 7. remove the jumper from 2 - 3 position to go b ack to the stand - by mode .
edition 12/2005 - 5 - 5 not e : the time outputs and the enrolment reader are not set to their default settings. relay outputs badge 1 access level 01 controller built - in reader activates rela y 1 remote reader 1 activates r ela y 1 badge 2 access level 02 controller built - in reader activates no relays remote reader 2 activates relay 2 badge 3 access level 03 controller built - in reader activates rela y 1 remote reader 1 activates relay 1 remote reader 2 activates relay 2 re set to factory default values cut the p ower on the dg502 unit place the jumper on st1 , 2 - 3 position power on the dg502 , the led is still off remo ve the jumper from st1, 2 - 3 position, the led flashes orange wiring of the remote readers follow the schematic on page 1 to connect remote reader 1 to the controller . connect terminals 2, 3, 4, 5, 12 and v from the controller directly to the term inals on the remote reader 1 . terminal 6 on the controller is connected to terminal 1 of remote reader 1 . for remote reader 2, connect in parallel terminals 2, 3, 4, 5, 12 and v from the controller unit . terminal 1 on the controller is connected to termin al 1 of remote reader 2. to power the remote readers use a different power supply or use the 12v output from the controller ( at the right hand completely it is the inputs 1 2v of the controller . the 12v at the left of the other 12v is the output ).
edition 12/2005 - 6 - 6 template 13mm 8 mm 3 x 6 mm 25 mm 116 m m = = 85 mm = = 22mm 116 mm 61,5m mmm 99 mm 75 mm dg 502 remote reader
edition 12/2005 - 7 - 7 wiring diagram between the dg502 and remote reader 1 3 2 v 1 4 5 12 distance 60 cm minimum 50 meters maximum back view remote reader c r t r c t s s b m e 1 2 3 4 5 6 12 v 12 v dg502 it is possible to use a separate power supply for the remote read er wiring d g502 remote reader 1 dg502 controller reader 1 12 input voltage 12 v input voltage v 6 data 1 2 buzzer 2 3 green led 3 4 comm o n 4 5 red led 5 it is recommended to keep a distance of 60 cm minimum between t he dg50 2 u controller and a remote reader, between 2 remote readers or between 2 dg502u controllers .
edition 12/2005 - 8 - 8 wiring diagram between th e dg502 and remote reader 2 dg502 remote reader 2 dg502 controller remote reader 2 12 input voltage 12 v input voltage v 1 d ata 1 2 buzzer 2 3 green led 3 4 c omm o n 4 5 red led 5 cardholder list : user username access user username access 3 2 v 1 4 5 12 c r t r c t s s b m e 1 2 3 4 5 6 12 v 12 v dg502 distance 60 cm minimum 50 meters maximum back view remote reader it is possible to use a separate power supply for the remote reader
edition 12/2005 - 9 - 9 location level location level menu valu es enrolment reader ? 0 00= controller 01= remote reader 1 door release time r elay 1 ? 1 01=1 s ec , 99=99 s ec door release time relay 2 ? 2 01=1 sec, 99=99 sec programm ed by : date site : n o. : street : city : other :