  specifications features the fcx -a iii absolute pressure transmitter accurately measures absolute pressure and transmits a proportional 4 to 20ma signal. the transmitter utilizes a unique micromachined capaci- tance silicon sensor with state-of-the-art microprocessor tech nology to provide exceptional performance and func- tionality. functional speci cations service: liquid, gas, or vapour span, range, and overrange limit: remark: to minimize environmental in uence, span should be greater than 1/40 of the max. span in most applications. the maximum span of each sensor can be converted to different units using factors as below. 1mpa abs=10 3 kpa abs=10bar abs=10.19716kgf/cm 2 abs =145.0377psi abs 1kpa abs =10mbar abs=101.9716mmh 2 o abs =4.01463inh 2 o abs=7.50062mmhg abs output signal: 4 to 20ma dc with digital signal super- imposed on the 4 to 20ma signal. power supply: transmitter operates on 10.5v to 45v dc at transmitter terminals. 10.5v to 32v dc for the units with op- tional arrester. 1. high accuracy 0.2% accuracy for all calibrated spans is a standard feature for all ap models covering 1.6kpa {0.016bar} range to 3000kpa {30bar} high pressure range. 0.1% accuracy is available as option. fujis micro-capacitance silicon sensor assures this accuracy for all suppressed calibration ranges without additional adjustment. 2. minimum environmental in uence the advanced floating cell design which protects the pressure sensor against changes in tempera ture, and overpressure substantially re duces total measure- ment error in actual eld applications. 3. fuji/hart bilingual communications protocol fcx -a iii series transmitter offers bilingual communica- tions to speak both fuji proprietary protocol and hart . any hart compatible devices can communicate with fcx -a iii . 4. application exibility various options that render the fcx -a iii suitable for almost any process applications include: ? full range of hazardous area approvals ? built-in rfi lter and lightning arrester ? 5-digit lcd meter with engineering unit ? stainless steel electronics housing ? wide selection of materials 5. burnout current exibility (under scale: 3.2 to 4.0ma, over scale: 20.0 to 22.5ma) burnout signal level is adjustable using model fxw hand held communicator (hhc) to comply with namur ne43. 6. dry calibration without reference pressure thanks to the best combination of unique construction of mechanical parts (sensor unit) and high performance electronics circuit (electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. absolute pressure transmitter fka 01 fka 02 fka 03 fka 04 overrange limit [mpa] {bar} type 0.5 {5} 0.5 {5} 1. 5 {15} 9 {90} min. range limit [kpa abs] {bar abs} span limit [kpa abs] {bar abs} 1. 6 {0.016} 1. 6 {0.016} 5 {0.05} 30 {0.3} 16 {0.16} 130 {1.3} 500 {5} 3000 {30} max. 0 to +16 {0 to +0.16} 0 to +130 {0 to +1.3} 0 to +500 {0 to +5} 0 to +3000 {0 to +30} data sheet fka ... 5 date EDSX5-91H aug. 10, 2011 [ l-type ] [ t-type ]
2 fka ... 5 (note) (1) hhc: hand held communicator load limitations: see gure below temperature limit: ambient: ?40 to +85? (?20 to +80? for lcd indicator) (?40 to +60? for arrester option) for explosionproof units ( ameproof or intrinsic safety), ambient temperature must be within the limits speci ed by each standard. process: ?40 to +85? for silicone ll sensor storage: ?40 to +90? humidity limit: 0 to 100% rh communication: with hhc (1) (model fxw, consult data sheet no. eds8-47), following items can be remotely displayed or con gured. note: hhcs version must be higher than 7.0 (or fxw 1 4), for fcx - a iii . local con gurator with lcd display (option): local con gurator with 3 push button and lcd display can support following items. items by communication with fxw by local con gurator (with 3 push button) display set display set tag no. vvvv model no. vvvv serial no. & software version v v engineering unit vvvv range limit v v measuring range vvvv damping vvvv output mode v v burnout direction vvvv calibration vvvv output adjust v v data v v self diagnoses v v printer (in case of fxw with printer option) v external switch lock vvvv transmitter display vvvv linearize vv rerange vvvv saturate current vvvv write protect vvvv history ?calibration history ?ambient temperature history v v v v v v emc conformity: en61326-1: 2006 note: for communication with hhc (1) (model: fxw), min. of 250 ? is required. hazardous locations: see table2 zero/span adjustment: zero and span are adjustable from the hhc (1) . zero and span are also adjustable externally from the adjustment screw. damping: adjustable from hhc or local con gurator unit with lcd display. the time constant is adjustable between 0.06 to 32 seconds. zero elevation/suppression: zero can be elevated within the speci ed range limit of each sensor model. normal/reverse action: selectable from hhc (1) . indication: analog indicator or 5-digit lcd meter, as speci ed. burnout direction: selectable from hhc (1) if self-diagnostic detect transmitter failure, the analog signal will be driven to either output hold? output overscale?or output underscale?modes. output hold? output signal is hold as the value just before failure happens. output overscale? adjustable within the range 20.0ma to 22.5ma from hhc (1) output underscale? adjustable within the range 3.2ma to 4.0ma from hhc (1) 3.2 4 20 22.5 [ma] over scale burnout probable over range probable under range normal operating range under scale burnout output limits comforming the namur ne43 by order. loop-check output: transmitter can be con gured to provide constant signal 3.2ma through 22.5ma by hhc (1) . 2000 [ ] 1500 1000 load resistance 500 250 0 1474 577 operating area 24v 45v 10 16.35 50 e[ v ] 10.5v power voltage (dc) r= e-10.5 (imax+0.9)x10 -3
3 performance speci cations reference conditions, silicone oil ll, 316ss isolating diaphragms, 4 to 20ma analog output in linear mode. accuracy rating: (including linearity, hysteresis, and re- peatability). (standard) for spans greater than 1/10 of url: ?.2% of span for spans below 1/10 of url: (option) (code: 21th digit h) (not available for max span 16kpa abs, 130kpa abs) for spans greater than 1/10 of url: ?.1% of span for spans below 1/10 of url: stability: ?.2% of upper range limit (url) for 10 years. temperature effect: effect per 28? change between the limits of - 40? and +85? zero shift: ( 0.125+0.1 ) % total effect: ( 0.15+0.1 ) % overrange effect: zero shift; ?.2% of url for any overrange to maximum limit supply voltage effect: less than 0.005% of calibrated span per 1v update rate: 60 msec step response: time constant: 0.08 s (at 23?) dead time: 0.12 s (without electrical damping) mounting position effect: zero shift, less than 0.1kpa{1mbar} for a 10?tilt in any plane. no effect on span. this error can be cor - rected by adjusting zero. dielectric strength: 500v ac, 50/60hz 1 min., between circuit and earth. insulation resistance: more than 100m ? at 500v dc. internal resistance for external eld indicator: 12 ? or less physical speci cations electrical connections: g 1 /2 , 1 /2 -14npt, pg13.5, or m20 x 1.5 conduit, as speci ed. process connections: 1 /4 -18 npt or rc 1 /4 on 54mm centers , as speci ed. process-wetted parts material: url span url span 0.1 x url span () ? 0.1 + 0.1 % of span 0.1 x url span () ? 0.05 + 0.05 % of span v h m a t e r i a l c o d e ( 7 t h d i g i t i n c o d e symbols? process cover 316 stainless steel (* 1 ) 316 stainless steel (* 1 ) 316l stainless steel hastelloy-c diaphragm 316 stainless steel hastelloy-c lining wetted sensor body 316/316l stainless steel 316/316l stainless steel vent/drain note: (* 1 ) scs14a per jis g 5121 (equivalent cf8m per astm a351/a351m) remarks: availab ility of above material design depends on ranges. refer to ?ode symbols? non-wetted parts material: electronics housing: low copper die-cast aluminum alloy nished with polyester coat ing (standard), or 316 stainless steel (astm cf8m), as speci ed. bolts and nut: cr-mo alloy (standard), 304 or 316 stainless steel fill uid: silicone oil mounting bracket: 304 or 316 stainless steel. environmental protection: iec ip67 and nema 6/6p mounting: on 60.5mm (jis 50a) pipe using mounting bracket, direct wall mounting, or direct process mounting. mass{weight}: transmitter approximately 2.9 to 3.4kg without options. add; 0.5kg for mounting bracket 4.5kg for stainless steel housing option optional features indicator: a plug-in analog indicator (2.5% accuracy) an optional 5-digit lcd meter with engineering unit is also available. local con gurator with lcd display: an optional 5 digits lcd meter with 3 push buttons can support items as using communication with fxw. arrester: a built-in arrester protects the electronics from lightning surges. lightning surge immunity: 4kv (1.2 ? 50?) degreasing: process-wetted parts are cleaned, but the ll uid is standard silicone oil. not for use on oxygen or chlorine measurement. nace speci cation: metallic materials for all pressure bound - ary parts comply with nace mr-01-75. 304 stainless steel bolts and nuts, astm b7m or l7m bolts and 2hm nuts (class ii) are available. optional tagplate: an extra stainless steel tag for customer tag data is wired to the transmitter. coating of cell: cells surface is finished with epoxy/ polyurethane double coating. specify if environment is extremely corrosive.
4 fka ... 5 description note note1 digit 4 6, 7 1v 1h 2v 2h 3v 3h 4v 4h 4567 123 f05 ka 89 10 11 12 13 14 15 21 digit no. of code span limit [kpa abs]{bar abs}(*1) 1.616 {0.0160.16} 1.6130 {0.0161.3} 5500 {0.055} 303000 {0.330} process cover 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel diaphragm 316l stainless steel hast. c 316l stainless steel hast. c 316l stainless steel hast. c 316l stainless steel hast. c wetted cell body 316 stainless steel hast. c lining 316 stainless steel hast. c lining 316 stainless steel hast. c lining 316 stainless steel hast. c lining 9 10 11 indicator arrester none none analog, 0 to 100% linear scale none analog, custom scale none none yes analog, 0 to 100% linear scale yes analog, custom scale yes digital, 0 to 100% linear scale none digital, custom scale none digital, 0 to 100% linear scale yes digital, custom scale yes digital, 0 to 100% linear scale (local configurator unit with lcd display) none digital, custom scale (local configurator unit with lcd display) none digital, 0 to 100% linear scale (local configurator unit with lcd display) yes digital, custom scale (local configurator unit with lcd display) yes none (for ordinary locations) tiis, flameproof (cable gland seal) (*6) tiis, intrinsic safety fm, flameproof (or explosionproof) (*9) fm, intrinsic safety and nonincentive fm combined of flameproof and intrinsic safety (*9) atex flameproof (*8) atex intrinsic safety atex type n atex combined of flameproof and intrinsic safety (*8) iecex scheme, flameproof (*8) iecex scheme, intrinsic safety csa, flameproof (or explosionproof) (*9) csa, intrinsic safety and nonincentive nepsi, flameproof (or exprosionproof) nepsi, intrinsic safety nepsi, combined of flameproof and intrinsic safety vent/drain mounting bracket standard none standard yes, stainless steel (sus304) standard yes, stainless steel (sus316) side none side yes, stainless steel (sus304) side yes, stainless steel (sus316) a c g d h v x k p m r t e j f s u a c k d f l a b d e f h l p q s 1 2 4 5 note1: (*1) 100: 1 turn down is possible, but should be used at a span greater than 1/40 of the maximum span for better performance. 5 6 7 8 9 s t v w x process connection rc 1 /4 1 /4 -18npt 1 /4 -18npt 1 /4 -18npt 1 /4 -18npt rc 1 /4 1 /4 -18npt 1 /4 -18npt 1 /4 -18npt 1 /4 -18npt oval flange screw 7 /16 -20unf 7 /16 -20unf m10 m10 7 /16 -20unf 7 /16 -20unf 7 /16 -20unf m10 m10 7 /16 -20unf conduit connection g 1 /2 1 /2 -14npt pg13.5 m201.5 pg13.5 g 1 /2 1 /2 -14npt pg13.5 m201.5 pg13.5 case type t type t type t type t type t type l type l type l type l type l type note6 note9 note9 note8 note8 note8 note9 code symbols
5 description note note 3 note 4 note 7 note 7 digit 12 13 14 15 21 extra ss tag plate stainless steel elec. housing coating of cell none none none yes none none none none yes yes none yes none yes yes yes yes yes treatment fill fluid standard silicone oil degreasing silicone oil nace specification silicone oil (7th digit code "t" and 15th digit code "a", "b" are not available) teflon (gasket) (*3) cr-mo alloy hexagon socket head cap screw/carbon steel nut cr-mo alloy hexagon bolt/nut nace bolt/nut (astm a193 b7m/a194 2hm) nece bolt/nut (astm a320 l7m/a194 2hm) 304 stainless steel bolt/304 stainless steel nut 316 stainless steel bolt/316 stainless steel nut (*4) high accuracy type (*7) instruction manual attached opposite vent/drain plug position instruction manual attached instruction manual unattached high accuracy type(*7) instruction manual unattached opposite vent/drain plug position instruction manual unattached 4567 123 f5 0 ka 89 10 11 12 13 14 15 21 note2: (*2) customer tag number can be engraved on standard stainless steel name plate. if extra tag plate is required, select "yes". note3: (*3) in case of tropical use, select stainless bolts and nuts. note4: (*4) if other option is not necessary, 21st digit code is blank. in case of 21st digit code is blank, instruction manual attached. note5: (*5) not available for 10th digit code c. note6: (*6) available for 4th digit code "s". note7: (*7) available for 6th digit code "3", "4". note8: (*8) available for 4th digit code "6", "8", "t", "w". note9: (*9) available for 4th digit code "6", "t". y g n a b c d e u h c l t p b digit digit no. of code note2 note5 note5 y b m n p q (*2) (*5) oval anges: (model ffp, refer to data sheet no. eds6- 128) converts process connection to 1 /2 -14 npt or to rc 1 /2 ; in carbon steel or in 316 stainless steel. hand held communicator: (model fxw, refer to data sheet no. eds 8-47) accessories ordering infomation when ordering this instrument, specify. 1. code symbols 2. measuring range. 3. output orientation (burnout direction) when abnormal- ity is occurred in the transmitter. hold / overscale / underscale unless otherwise specified, output hold function is supplied. 4. indication method (indicated value and unit) in case of the actual scale (code d, h, p, s on 9th digit). 5. tag no. (up to 14 alphanumerical characters), if re- quired.
6 fka ... 5 outline diagram (unit:mm) 4&&5"#-& 4&&5"#-& uiejhjupguif dpeftzncpmt  (   3d %&' ) 6/' 4$3&8%&15) $poevjudpoo 1sfttdpoo 0wbmgsbohftdsfx %&5"*-" 13&44$0//
%&5"*-# $0/%6*5$0//
5"#-&  /15   #% ) 6/' 4$3&8%&15)  1h   #% ) . 4$3&8%&15)  .   #% ) . 4$3&8%&15)  1h   #% ) 6/' 4$3&8%&15) 7&/5%3"*/1-6( 8)&/5)&7&/5%3"*/1-6( "55"$)&%0/5)&611&34*%& 0'5)&%&5&$503
/05&
"13&44$0// .5(1*1&+*4" #
)0-&4%*" 6#0-5. 7&/5%3"*/1-6( &"35)5&3.*/"- 07"-'-"/(&4$3&8 4&&5"#-& )1 -1 . ;&30"%+4$3&8 #$0/%6*5$0// */$"4&0'5)%*(*5$0%& */$"4&0'5)%*(*5$0%&    8*5)"/"-0(*/% 8*5)%*(*5"-*/% 
/05&
         

          ;&30 4$4 4*%&7&/5 015*0/
 )      ' & %  /05&  /05&
8)&/5)&5)%*(*50'5)&$0%&4:.#0-4) . 5 /05&
5)&13&4463&$0//&$503*4-0$"5&%0/5)&%08/4*%&  463'"$&0'5)&%&5&$503 8)&/5)&7&/5%3"*/1-6(*4  "55"$)&%0/5)&611&34*%&0'5)&%&5&$503  8)&/5)&45%*(*50'5)&$0%&4:.#0-4$ 1
 445"(1-"5& $0//&$5*0/%*"(3". $, $,  
7 */$"4&0'5)%*(*5$0%&5 */$"4&0'5)%*(*5$0%&4 7 8 9 ;&30"%+4$3&8 "13&44$0// .5(1*1&+*4" #
)0-&4%*" 6#0-5. 7&/5%3"*/1-6( 8*5)"/"-0(*/% &"35)5&3.*/"- 07"-'-"/(&4$3&8 4&&5"#-& )1 -1 . 4&&5"#-& 4&&5"#-& %&5"*-" 13&44$0//
%&5"*-# $0/%6*5$0//
7&/5%3"*/1-6( 8)&/5)&7&/5%3"*/1-6("55"$)&% 0/5)&611&34*%&0'5)&%&5&$503
/05&

/05&
8*5)%*(*5"-*/%                           )      ' & % 4*%&7&/5 015*0/
30   /05& #$0/%6*5$0// uiejhjupguif dpeftzncpmt 4 (   3d %&' ) 6/' 4$3&8%&15) $poevjudpoo 1sfttdpoo 0wbmgsbohftdsfx 5"#-& 5 /15   #% ) 6/' 4$3&8%&15) 7 1h   #% ) . 4$3&8%&15) 8 .   #% ) . 4$3&8%&15) 9 1h   #% ) 6/' 4$3&8%&15) /05&
8)&/5)&5)%*(*50'5)&$0%&4:.#0-4) /05&
5)&13&4463&$0//&$503*4-0$"5&%0/5)&%08/4*%&  463'"$&0'5)&%&5&$503 8)&/5)&7&/5%3"*/1-6(*4  "55"$)&%0/5)&611&34*%&0'5)&%&5&$503  8)&/5)&45%*(*50'5)&$0%&4:.#0-4$ 1
 /05&
*/$"4&0'5)$0%& ?$? $"#-&*446*5#-& ( %&5"*-l$z    ( 015*0/1"354'03'-".&1300'0'5**4 +"1"/
uiejhjudpef$ $bcmfhmboeuzqf
 /05&
$"#-&(-"/%    $$0/%6*5$0// 445"(1-"5& $0//&$5*0/%*"(3". $, $,  
printed in japan caution on safety *before using this product, be sure to read its instruction manual in advance. international sales div sales group gate city ohsaki, east tower, 11-2, osaki 1-chome, shinagawa-ku, tokyo 141-0032, japan http://www.fujielectric.com phone: 81-3-5435-7280, 7281 fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ information in this catalog is subject to change without notice. fka ... 5 atex ex ii 2 gd ex d iic t6 ip66/67 t85c tamb = ?40c to +65c ex d iic t5 ip66/67 t100c tamb = ?40c to +85c factory mutual class i div.1 groups b, c, d t6 type 4x class ii iii div.1 groups e, f, g t6 type 4x tamb max = +60c csa class i div.1 groups c, d class ii div.1 groups e, f, g class iii div.1 note) seal not required enclosure is allowed. tiis ex do iib+h 2 t4 tamb max = +60c maximum process temp. = +120c iecex scheme ex d iic t5 ip66/67 tamb = ?40c to +85c ex d iic t6 ip66/67 tamb = ?40c to +65c authorities flameproof nepsi ex d iib+h 2 t6 tamb = ?40c to +60c atex ex ii 1 g ex ia iic t5 tamb = C40c to +50c ex ia iic t4 tamb = C40c to +70c entity parameters: ui=28v, ii=94.3ma, pi=0.66w, ci=26nf (without arrester), li=0.6mh (without analog indicator), ci=36nf (with arrester), li=0.7mh (with analog indicator) factory mutual class i ii iii div.1 groups a, b, c, d, e, f, g t4 entity type 4x entity parameters: vmax=28v, imax=94.3ma, pi=0.66w, ci=35.98nf, li=0.694mh csa class i div.1 groups a, b, c, d class ii div.1 groups e, f, g class iii div.1 temp code t5 tamb max = +50c temp code t4 tamb max = +70c entity parameters: vmax=28v, imax=94.3ma, ci=25nf (without arrester), ci=36nf (with arrester), li=0.6mh (without analog meter), li=0.7mh (with analog meter) tiis ex ia iic t4 tamb max = +60c entity parameters: ui=28v, ii=94.3ma, pi=0.66w, ci=38.4nf, li=0.694mh iecex scheme ex ia iic t4 tamb = C40c to +70c ex ia iic t5 tamb = C40c to +50c entity parameters: ui=28v, ii=94.3ma, pi=0.66w, ci=26nf (without arrester), li=0.6mh (without analog indicator), ci=36nf (with arrester), li=0.7mh (with analog indicator) authorities intrinsic safety model code 9th digit a,b,d C40c to +85c l,p,1,2 C20c to +80c q,s,4,5 C20c to +60c e,f,h C40c to +60c tamb nepsi ex ia iic t4 ex d iib+h 2 t6 / ex ia iic t4 entity parameters: ui=42.4v, ii=113ma, pi=1w, ci=35.98nf, li=0.694mh model code 9th digit 13th digit a,b,d y,g,n C40c to +85c l,p,1,2 y,g,n C20c to +80c q,s,4,5 y,g,n C20c to +60c e,f,h y,g,n C40c to +60c tamb atex ex ii 3 gd eex nl iic t5 tamb = C40c to +50c eex nl iic t4 tamb = C40c to +70c specific parameters: model without arrester: ui=42.4v, ii=113ma, pi=1w, ci=25.18nf, li=0.694mh model with arrester: ui=32v, ii=113ma, pi=1w, ci=35.98nf, li=0.694mh eex nal iic t5 tamb = C40c to +50c eex nal iic t4 tamb = C40c to +70c specific parameters: model without arrester: umax=42.4v, imax=113ma, pmax=1w model with arrester: umax=32v, imax=113ma, pmax=1w factory mutual (pending) class i ii iii div.2 groups a, b, c, d, f, g t4 entity type 4x csa class i div.2 groups a, b, c, d class ii div.2 groups e, f, g class iii div.2 temp code t5 tamb max = +50c temp code t4 tamb max = +70c entity parameters: vmax=28v, ci=25.18nf (without arrester), ci=35.98nf (with arrester), li=0.694mh authorities type n nonincendive model code 9th digit a,b,d C40c to +85c l,p,1,2 C20c to +80c q,s,4,5 C20c to +60c e,f,h C40c to +60c tamb table 2


▲Up To Search▲   

 
Price & Availability of EDSX5-91H

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X