Part Number Hot Search : 
C3216J 0DT90 11610 30006 D471A HM100 10PF06 086T2
Product Description
Full Text Search
 

To Download EDSX5-86D Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  features specifications data sheet fhg ... 4 functional specifications service: liquid, gas, or vapour span, range and overrange limit: pressure transmitter fhg 02 fhg 03 fhg 04 type overrange limit [mpa] {bar} 1.5 {15} 9 {90} 15 {150} min. max. span limit [kpa] {bar} 16.66 {0.16} 100 {1} 333.3 {3.33} 500 {5} 3000 {30} 10000 {100} range limit [kpa] {bar} 500 {5} 3000 {30} 10000 {100} lower limit upper limit ?00 {?} ?00 {?} ?00 {?} lower range limit (vacuum limit) ; silicone fill sensor: see fig. 1 fluorinated fill sensor: 66kpa abs (500mmhg abs) at below 60 c conversion factors to different units; 1 mpa=10 3 kpa=10bar=10.19716kgf/cm 2 = 145.0377psi 1kpa=10mbar=101.9716mmh 2 o =4.01463inh 2 o output signal: 4 to 20ma dc with digital signal super- imposed on the 4 to 20ma signal. power supply: transmitter operates on 10.5v to 45v dc at transmitter terminals. 10.5v to 32v dc for the units with optional arrester. the fcx a 2 e pressure transmitter accurately measures gauge pressure and transmits a proportional 4 to 20ma signal. the transmitter utilizes a unique micromachined capaci- tance silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and func- tionality. 1. high accuracy 0.1% 0.1% accuracy is a standard feature. fuji? micro-capaci- tance silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional ad- justment. 2. minimum environmental influence the ?dvance floating cell?design which protects the pressure sensor against changes in temperature, and overpressure substantially reduces total measurement error in actual field applications. 3. fuji/hart bilingual communications protocol fcx? 2 e series transmitter offers bilingual communica- tions to speak both fuji proprietary protocol and hart . any hart compatible devices can communicate with fcx? 2 e. 4. application flexibility various options that render the fcx a 2 e suitable for al- most any process applications include: analog indicator at either the electronics side or ter- minal side full range of hazardous area approvals built-in rfi filter and lightning arrester 5-digit lcd meter with engineering unit 5. burnout current flexibility (under scale: 3.2 to 3.8ma, over scale: 20.8 to 21.6ma) burnout signal level is adjustable using model fxw hand held communicator (hhc) to comply with namur ne43. 6. dry calibration without reference pressure thanks to the best combination of unique construction of mechanical parts (sensor unit) and high performance electronics circuit (electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. date EDSX5-86D apr. 25, 2003
fhg ... 4 2 load limitations: see figure below loop-check output: transmitter can be configured to provide constant signal 3.8ma through 21.6ma by hhc. temperature limit: ambient: 40 to +85 c (?0 to +80 c for lcd indicator) ( 40 to +60 c for arrester option) (?0 to +60 c for fluorinated oil fill transmitter) for explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits specified by each standard. process: 40 to +100 c for silicone fill sensor ?0 to +80 c for fluorinated oil fill sen- sor storage: ?0 to +90 c humidity limit: 0 to 100% rh communication: with hhc (1) (model fxw, consult data sheet no. eds8-47), following informa- tion can be remotely displayed or recon- figured. note: hhc's version must be more than 6.0 (or fxw 1 3), for fcx- a 2 . note: for communication with hhc (1) (model: fxw), min. of 250 ? required. hazardous locations: zero/span adjustment: zero and span are adjustable from the hhc (1) . zero and span are also adjustable externally from the adjustment screw (span adjustment is not available with 9th digit code "l, p, q, s"). damping: adjustable from hhc or local adjustment unit with lcd display. the time constant is adjustable between 0.12 to 32 seconds. zero elevation/suppression: zero can be elevated or suppressed within the specified range limit of each sensor model. normal/reverse action: selectable from hhc (1) . indication: analog indicator or 5-digit lcd meter, as specified. burnout direction: selectable from hhc (1) if self-diagnostic detect transmitter fail- ure, the analog signal will be driven to ei- ther ?utput hold? ?utput overscale or ?utput underscale?modes. ?utput hold? output signal is hold as the value just be- fore failure happens. ?utput overscale? adjustable within the range 20.8ma to 21.6ma from hhc (1) ?utput underscale? adjustable within the range 3.2ma to 3.8ma from hhc 3.8 3.2 4 20 20.8 21.6 [ma] over scale burnout probable over range probable under range normal operating range under scale burnout 2000 [ ? ] 1500 1000 load resistance 500 250 1533 ? 600 ? operating area 24v 45v 10 16.1 50 [ v ] 10.5v power voltage tag no. model no. serial no. engineering unit range limit measuring range damping output mode burnout direction calibration output adjust data self diagnoses printer external switch lock transmitter display linearize rerange items display set vv vv v vv v vv vv v vv vv v v v vv vv vv vv (note) (1) hhc: hand held communicator factory class i ii iii class i ii iii class i ii iii mutual div. 1 div. 1 div. 2 groups b thru. g groups a thru. f groups a thru. g csa class i ii iii class i ii iii class i ii iii div. 1 div. 1 div. 2 groups c thru. g groups a thru. g groups a thru. g tiis ex do iib+h 2 t4 ex ia ii c t4 (*) (*) approval pending type n nonincendive authorities flameproof intrinsic safety
3 physical specifications electrical connections: g 1 /2 , 1 /2 -14 npt, pg13.5, or m20 1.5 conduit, as specified. 1-port (standard), as spcified. process connections: 1 /4 -18 npt or rc 1 /4 on 54mm centers, as specified. meet din 19213 process-wetted parts material: performance specifications reference conditions, silicone oil fill, 316ss isolating diaphragms, 4 to 20ma analog output in linear mode. accuracy rating: (including linearity, hysteresis, and re- peatability) for spans greater than 1/10 of url: 0.1% of span for spans below 1/10 of url: stability: 0.2% of upper range limit (url) for 6 month. temperature effect: effects per 28 c change between the lim- its of 40 c and +85 c zero shift: (0.1+0.025 )% total effect: (0.125+0.025 )% overrange effect: zero shift; 0.3% of url for any overrange to maximum limit supply voltage effect: less than 0.005% of calibrated span per 1v rfi effect: less than 0.2% of url for the frequen- cies of 20 to 1000mhz and field strength 30 v/m when electronics covers on. (classification: 2-abc: 0.2% span per sama pmc 33.1) step response: time constant: 0.2s dead time: approximately 0.2s (without electrical damping) mounting position effect: zero shift, less than 0.1kpa {1m bar} for a 10 tilt in any plane. no effect on span. this error can be cor- rected by adjusting zero. dielectric strength: 500v ac, 50/60hz 1 min., between circuit and earth. insulation resistance: more than 100m ? at 500v dc. turn-on time: 4 sec. internal resistance for external field indicator: 12 ? or less url span url span v 316 stainless steel 316 stainless steel 316l stainless steel 316 stainless steel(*1) material code (7th digit in code symbols) process cover diaphragm wetted sensor body vent/drain note: *(1) scs14 per jis g 5121 remark: sensor o-rings: viton o-ring and teflon gasket select- able non-wetted parts material: electronics housing: low copper die-cast aluminum alloy finished with epoxy/ polyurethane double coating. bolts and nuts: cr-mo alloy (standard), or 304 stainless steel (630 stainless steel for 50mpa unit). fill fluid: silicone oil (standard) or fluori- nated oil mounting bracket: 304 stainless steel environmental protection: iec ip67 mounting: on 60.5mm (jis 50a) pipe using mount- ing bracket, direct wall mounting, or direct process mounting. mass {weight}: transmitter approximately 3.4kg without options. add; 0.5kg for mounting bracket 0.8kg for indicator option 0.1 url span 0.05+0.05 % of span ( )
fhg ... 4 4 optional features indicator: a plug-in analog indicator (1.5% accuracy) can be housed in the electronics compart- ment or in the terminal box of the hous- ing. an optional 5-digit lcd meter with engi- neering unit is also available. local adjustment unit with lcd display: an optional 5-digit lcd meter with zero/ span adjustment function, loop-check function and damping adjustment func- tion, is available. arrester: a built-in arrester protects the electronics from lightning surges. lightning surge immunity: 4kv (1.2 50 s) oxygen service: special cleaning procedures are followed throughout the process to maintain all pro- cess wetted parts oil-free. the fill fluid is fluorinated oil. chlorine service: the fill fluid is fluorinated oil. degreasing: process-wetted parts are cleaned, but the fill fluid is standard silicone oil. not for use on oxygen or chlorine measurement. nace specification: metallic materials for all pressure bound- ary parts comply with nace mr-01-75. astm b7m or l7m bolts and 2hm nuts (class ii) are available. optional tag plate: an extra stainless steel tag with customer tag data is wired to the transmitter. accessories 40 60 120 none-operating area 2.7 {27} 4 {40} 20 operating pressure process temperature[ c ] {200} 101 {1010} [kpa abs] {mbar abs} silicone oil (code:y,g,n) operating area fig. 1 relation between process temperature and operating pressure hand-held communicator: (model fxw, refer to data sheet no. eds8-47) z/s board: parts no.=zzpfcx4-a070 when z/s board is mounted on the fcx a 2 amplifier unit, external adjustment screw will be available for zero and span adjustment. the product conforms to the requirements of the electromagnetic compatibility directive 94/9/ec as detailed within the technical construction file number tn513035. the applicable standards used to demonstrate compliance are : frequency range mhz limits reference standard 30 to 230 40db ( v/m) quasi peak, measured at 10m distance 230 to 1000 47db ( v/m) quasi peak, measured at 10m distance cispr16-1 and cispr16-2 phenomenon test value basic standard performance criteria b electrostatic discharge conducted rf 0.15 to 80mhz 3v 80%am (1khz) electromagnetic field 4kv (contact) 8kv (air) 80 to 1000mhz 10v/m 80%am (1khz) iec61000-4-2 burst a iec61000-4-3 rated power frequency magnetic field 30a/m 50hz a iec61000-4-8 2kv 5khz b iec61000-4-4 surge 1.2 s/50 s 1kv (line to line) 2kv (line to ground) b iec61000-4-5 a iec61000-4-6 emi (emission) en61326 : 1997 class a (standard for industrial location) emi (immunity) en61326: 1997 annex a (standard for industrial location) note) definition of performance criteria a: during testing, normal performance within the specification limits. b: during testing, temporary degradation, or loss of function or performance which is self-recovering. ordering information when ordering this instrument, specify. 1. code symbols 2. measuring range 3. output orientation (burnout direction) when abnormality is occured in the transmitter. hold/overscale (21.6ma)/overscale (3.2ma) unless otherwise specified, output hold function is sup- plied. 4. indication method (indicated value and unit) in case of the actual scale (code d,h,p,s on 9th digit). 5. tag no.(up to 26 alphanumerical characters), if required. oval flanges: (model ffp, refer to data sheet no. eds6-10) converts process connection to 1 /2 -14 npt or to rc 1 /2 ; in carbon steel or in 316 stainless steel.
5 code symbols span limit [kpa]{bar} 16.66 500 {0.16 5} 100 3000 {1 30} 333.3 10000 {3.33 100} process cover 316 stainless steel 316 stainless steel 316 stainless steel diaphragm 316l stainless steel 316l stainless steel 316l stainless steel wetted cell body 316 stainless steel 316 stainless steel 316 stainless steel description note 1 note digit 4 6, 7 2v 3v 4v 4567 123 f04 hg 89 10 11 12 13 14 15 digit no. of code a b c d e process connection rc 1 /4 1 /4 -18npt 1 /4 -18npt 1 /4 -18npt 1 /4 -18npt oval flange screw 7 /16 -20unf 7 /16 -20unf m10 m10 7 /16 -20unf conduit connection g 1 /2 ( 1) 1 /2 -14npt ( 1) pg13.5 ( 1) m20 1.5 ( 1) pg13.5 ( 1) 9 10 indicator arrester none none analog, 0 to 100% linear scale none analog, custom scale none none yes analog, 0 to 100% linear scale yes analog, custom scale yes digital, 0 to 100% none digital, custom scale none digital, 0 to 100% yes digital, custom scale yes digital, 0 to 100% (local adjustment unit with lcd display) none digital, custom scale (local adjustment unit with lcd display) none digital, 0 to 100% (local adjustment unit with lcd display) yes digital, custom scale (local adjustment unit with lcd display) yes none (for ordinary locations) tiis, flameproof (conduit seal) (available for 4th digit code a ) tiis, flameproof (cable gland seal) (available for 4th digit code a ) fm, flameproof (or explosion proof) (available for 4th digit code b ) csa frameproof (or explosion proof) (available for 4th digit code b ) tiis, intrinsic safety (approval pending) fm, intrinsic safety and nonincendive csa intrinsic safety and nonincendive a b c d e g h j a b d e f h l p q s 1 2 4 5 11 12 13 14 15 vent/drain mounting bracket standard none standard yes, stainless steel side none side yes, stainless steel extra ss tag plate stainless steel elec. housing coating of cell none none none yes none none none none yes yes none yes treatment fill fluid standard silicone oil degreasing silicone oil oxygen service fluorinated oil (7th digit code v only) nace specification silicone oil (not available for 15th digit code a , b ) viton (o-ring) teflon (gasket) cr-mo alloy hexagon socket head cap screw/carbon steel nut cr-mo alloy hexagon bolt/nut nace bolt/nut (astm a193 b7m/a194 2hm) nace bolt/nut (astm a320 l7m/a194 2hm) 304 stainless steel bolt/304 stainless steel nut a c d f y b m n y g a n a b c d e a b (*1) z/s board attached. approval pending for 10th digit code "g, h, j" approval pending for 10th digit code "d, e, g, h, j" note 1: (*1) costomer tag number can be engraved on standartd stainless steel name plate. if extra tag plate is required, select yes .
fhg ... 4 outline diagram (unit:mm) note1) cable gland is supplied in case of 10th digit code "c". 11 cable is suitable. note2) the pressure connector is located on the down side surface of the detector, when the vent / drainplug is attatched on the upper side of the detector conduit conn. press.conn. def h oval flange screw g 1 /2 17 8 rc 1 /4 7 /16 -20unf screw depth15 a 1 /2 -14npt 16 5 1 /4 -18npt 7 /16 -20unf screw depth15 b pg13.5 8 4.5 1 /4 -18npt m10 screw depth15 c m20 1.5 16 5 1 /4 -18npt m10 screw depth15 d pg13.5 8 4.5 1 /4 -18npt 7 /16 -20unf screw depth15 e 4th digit of the code symbols ck ck connection diagram (27) h 7 38 58 37 210 189 (6th digital code 5 ) 70 80 52.5 88 104 130 80 approx.147 43 27 70 104 231 mtg. pipe jis 50a (2b) u - bolt m8 "a" press. conn. zero adj. screw fastener (flameproof only) cable gland (option) "c" conduit conn. "b" conduit conn. vent/drain plug 4 holes 9 dia. detail "b" detail "c" 8 2.5 see table 1 earth terminal oval flange screw see table 1 side vent (option) with field ind. (option) up down 41.3 54 (conduit conn.) detail "a" (press. conn.) 18.5 vent/drain plug (when the vent/drain plug attached on the upper side of the detector) 4-m8 12 (m4 screws) note1) note2) table 1 17 g 1 /2 13 d e f 15 see table 1 electronics unit sensor unit 41 information in this catalog is subject to change without notice. printed in japan head office 6-17, sanbancho, chiyoda-ku, tokyo 102-0075, japan http://www.fesys.co.jp/eng sales div. international sales dept. no.1, fuji-machi, hino-city, tokyo, 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187 http: //www.fic-net.jp/eng caution on safety *before using this product, be sure to read its instruction manual in advance.


▲Up To Search▲   

 
Price & Availability of EDSX5-86D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X