21/4/2011 cfam 30p3600 capacitive sensors capacitive sensors www.baumer.com general data mounting type shielded nominal sensing distance sn 15 mm nominal sensing distance sn adjustable 4 ... 15 mm temperature drift 15 % (+10 ... +70 c) sensitivity adjustment potentiometer output indicator led yellow electrical data voltage supply range +vs 10 ... 30 vdc current consumption max. 20 ma output circuit pnp break function (nc) output current < 200 ma voltage drop vd < 1,5 vdc switching frequency < 50 hz short circuit protection yes reverse polarity protection yes mechanical data type cylindrical threaded housing material brass nickel plated dimension 30 mm housing length 71 mm connection types cable, 2 m ambient conditions operating temperature -25 ... +75 c protection class ip 65 photo connection diagram output +v s pnp bu (3) bn (1) bk (4) z 0 v dimension drawing 58 71 m30 x 1, 5 po t le d sw 36
|