Part Number Hot Search : 
TLRE50T EMP202 72F32 AN7522 LTC2496 4H560838 HMNP16MM IRFP150A
Product Description
Full Text Search
 

To Download POE20D-1AF Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  revision 11/17/2011 www.phihong.com 19.6w power over ethernet adapter dc input single port injector features ? detection and classifi cation per ieee802.3af ? unh iol tested ? diagnostic leds ? full protection ocp, ovp ? non-vented case ? gigabit compatible ? dc input voltage 18-72vdc ? lowest cost dc input power injector ? 1 year warranty applications ? ip telephones ? security cameras ? wireless network access points ? ip print servers ? blue tooth access point safety approvals ? ce mechanical characteristics ? length: 140mm (5.51in) ? height: 36mm (1.42in) ? width: 65mm (2.55in) ? weight: 0.2kg (0.44lb.) output specifications phihong is not responsible for any error, and reserves the righ t to make changes without notice. please visit our website at www.phihong.com for the most up-to-date specifications and co ntact information. model dc output voltage load regulation POE20D-1AF 56v min. max. line load 0a 0.35a 54-57vdc under all conditions
poe20d ? 1af characteristics www.phihong.com input: dc input voltage range 18 to 72vdc dc input current 1.5a for 18v dc and maximum load output: total output power 19.6w at 56vdc dc offset no data degradation with dc imbalance 18ma efficiency 80% at maximum load (>36 to 72vdc) 75% at maximum load(18 to <36vdc) ripple and regulation 100mv maximum at ambient 25c transient o/p voltage protection 60v maximum at switch on and off environmental: temperature operation -20 to +50c non-operation -25 to +85c humidity operation 5 to 90% emc fcc part 15 class b en55022 class b isolation test primary to secondary: 2121vdc for 1 minute, 10ma primary to field ground: 2121vdc for 1 minute, 10ma output to field ground: 2121vdc for 1 minute, 10ma immunity esd: en61000-4-2. level 3 rs: en61000-4-3. level 3 eft: en61000-4-4. level 2 surge: en61000-4-5. level 3 cs: en61000-4-6. level 3 voltage dips en61000-4-11 harmonic: en61000-3-2 insulation resistance primary to secondary: >10m ohm 500vdc primary to field ground: >10m ohm 500vdc feature: over voltage/current, sho rt circuit protection outputs equipped with short circuit protection and overload protection as per 802.3af specification the output can be shorted permanently without damage indicators green led 1: input power ?on? red led: fault detected green led 2: valid ieee802.3af load detected and connected input connector ? anytek oq0355510000g mate ? anytek tj0350520000g or tj035152000g anytek is part of giga-way technology corp output connection +pins 3, 6 - pins 1 ,2 warranty 1 year dimension diagram unit: mm (inch)
gigabit power injector block diagram description of led functions for gigabit power injector power-up sequence: upon power-up, all 3 leds will light for 2 seconds, as part of the self-test for the internal microprocessor software. after the end of the 2 seconds, the "on" led will illuminate green, signifying that the dc output voltage is available for powering a compliant load (to the 802.3af poe standards). detection sequence: once a compliant load is attached to the output rj45 connector, the green "connect" led will illuminate. should the load be non-compliant then the leds will blink a code signifying the cause for non- detection. detection failure codes: 1. incorrect resistive signature ? the green ?con nect? and red ?fault? le ds will blink 3 times. 2. incorrect capacitive signature ? th e green ?on? led will blink 3 times. 3. incorrect voffset ? the green ?connect? and green ?on? leds will blink 3 times. 4. unstable current measurement ? th e green ?on? led will blink 3 times 5. low voltage sensed during detection (overload) ? the red ?fault? led will blink 3 times after the leds blink 3 times the power injector will continue to try to detect a valid load. therefore, until the correct load is applied, the leds will continue to blink. if there is an open circuit connected to the output rj45 then the leds will not blink but the power injector will continue to try to detect a valid load. fault sequence: should there be a fault such as an overload or sh ort circuit then the red "fault" led will illuminate. the red ?fault? led will illuminate for 2 seconds and then go off as the power supply tries to redetect a valid load. if there is a problem in detecting, the led will indicate what is wrong with the load as per the codes in the section above.


▲Up To Search▲   

 
Price & Availability of POE20D-1AF

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X