  ial/cel/lel series magnetic circuit protectors ? 133 ? 134 ? 136 ? 140 ? 143 ? 145 ? 149 ? 151 introduction poles handles configurations operating characteristics delay curves specifications decision tables
introduction ial/iul/iel/lel magnetic circuit protectors provide low-cost power switching, reliable circuit protection and accurate circuit control for equipment in the international marketplace. ial models are for those applications where the units inherent attributes are desired, but compliance with the various standards is not required. iul models have been tested and approved in accordance with ul 1077 requirements for ul recognition. iel/lel models are vde approved to vde 0660, part 101. they meet iec spacing requirements, mandatory for equipment which must comply with iec specifications 601 and 950, and vde specifications 0804 and 0805. in addition, the iel models are ul recognized to ul 1077 as supplementary protectors and the lel models are ul listed under the conditions of ul 489. both are csa certified and ccc approved. the iel is csa certified as a supplementary protector per csa c22.2Cno. 235. the cel model has achieved two new enhancements, including a single pole, 125 amp rating with tv approval, and a parallel 4-pole version with 400 amp rating. airpax? ial/cel/lel circuit protectors are available in a wide variety of configurations, including series, series with auxiliary switch, shunt and relay with choice of delays and ratings in dc and/or 50/60hz or 400hz versions. single or multi-pole versions are available with a variety of pole arrangements to meet your specifications. please see the appropriate product specification table for ratings and limitations. ial/cel/lel series hydraulic magnetic circuit protectors ial series - introduction http://airpax.sensata.com 133
single pole, standard stud terminal [19.05] .750 [36.53] 1.438 [63.24] 2.490 [10.21] .402 [5.59] .220 [52.32] 2.060 2x 6-32 thread .140 [3.56] deep m3 iso thd. optional (see table) (see table) [3.56] .140 [3.61] .142 [47.22] 1.859 [17.53] .690 on off [7.14] .281 [49.28] 1.940 [7.13] .281 [49.28] 1.940 [3.61] .142 screw terminal [7.13] .281 [49.28] 1.940 [6.35] ? .250 max. [15.04] .592 [9.96] .392 [9.53] .375 single pole clip terminal [24.57] .967 bullet terminal notes: tolerance .015 [.39] unless noted. dimensions in brackets [ ] are millimeters. a terminal protrusion dimensions are referenced from back of mounting panel. b each screw terminal is supplied with a 1 0-32x.312 [7.92] or m5 x 8mm screw, flatwasher and external tooth lockwasher. c stud terminals are supplied with a flatwasher, external tooth lockwasher and a 10-32 or m5 hex nut (<=70a) (<=50a for lel),1/4-20 or m6 hex nut (>70a)(>50a for lel). [19.18] .755 [52.32] 2.060 [36.78] 1.448 [3.96] 2x ? .156 [10.98] .432 mounting detail note: each outer terminal is supplied with a flatwasher, tooth lockwasher and a hex nut. bullet terminal receptacle should be .312 .001 diameter hole not less than .250 depth. contact sensata for other bullet sizes. stud terminal types screw stud thread dimension a dimension b m6 .510 .045 12.95 1.14 .652 .035 16.56 0.89 1/4 -20 .545 .045 13.84 1.14 .687 .035 17.45 0.89 m5 .510 .045 12.95 1.14 .652 .035 16.56 0.89 10-32 .545 .045 13.84 1.14 .687 .035 17.45 0.89 panel mounting detail tolerance .005 .13 unless noted. ial series - poles ial series 134
note: a terminal protrusion dimensions are referenced from back of mounting panel. b each screw terminal is supplied with a 10-32x.312 [7.92] or m5 x 8mm screw, flatwasher and external tooth lockwasher. c stud terminals are supplied with a flatwasher, external tooth lockwasher and a 10-32 or m5 hex nut (<=70a), 1/4 -20 or m6 hex nut (>70a). (see table) (see table) [3.56] .140 [3.61] .142 [47.22] 1.859 [17.53] .690 on off [7.14] .281 [49.28] 1.940 two pole [5.59] .220 max. [36.53] 1.438 [63.24] 2.490 [10.21] .402 [52.32] 2.060 [38.48] 1.515 4x 6-32 thread .140 [3.56] deep m3 iso thd. optional max. [38.48] 1.515 ielh11 iel11 note: tolerance .015 [.38] unless noted. dimensions in brackets [ ] are millimeters. [19.05] .750 [52.32] 2.060 [38.86] 1.530 [36.78] 1.448 [10.97] .432 [3.96] 4x ? .156 two pole* [19.05] .750 two pole* m6 1/4 - 20 m5 10 - 32 screw stud thread .510 .545 .510 .545 dim. a? ( .045) .652 .687 .652 .687 dim. b? ( .035) note: each outer terminal is supplied with a flatwasher, tooth lockwasher and a hex nut. panel mounting detail tolerance .005 [.13] unless noted. multi-pole units are combined in an assembly with the trip mechanisms internally coupled. a fault in any protected circuit opens all poles simultaneously. applications include use in polyphase circuits, single-phase three-wire systems, or in two or more related but electrically isolated circuits. a mix of delays, ratings and configurations are offered. the auxiliary switch is offered with either gold or silver contacts and is available when a series construction pole is specified. two pole units an assembly consisting of two single pole units, having their trip mechanisms internally coupled, is available with either a single toggle handle or with a handle per pole. please see decision one of the part number decision tables. individual poles may vary in ratings, delays and internal configurations. if the poles are of series construction, an auxiliary switch may be included in either or both poles, allowing you to mix selv and hazardous voltages. multi-pole circuit protectors ial series - poles http://airpax.sensata.com 135
[57.53] 2.265 max. three pole and four pole units the three pole structure consists of three single pole units assembled with an internal mechanical interlock which actuates all units simultaneously. the units are available with either a single toggle handle or with a handle per pole. units with four pole construction operate with a minimum of two center toggle handles or with a handle per pole. please see decision one of the part number decision tables. mixing of delays, ratings and configurations is available in each individual pole. the auxiliary switch is offered in any series trip pole. breaker poles are numbered consecutively when viewed from the terminal side, with the on position up, starting with pole #1 on the left side and proceeding to the right. three pole iel111 max. [57.53] 2.265 mounting detail* [19.05] .750 [19.05] .750 [57.91] 2.280 max. [76.58] 3.015 four pole iel1111 [19.05] .750 [19.05] .750 [19.05] .750 [38.86] 1.530 mounting detail* [19.05] .750 [19.05] .750 note: tolerance .015 [.39] unless noted. dimensions in brackets [ ] are millimeters. *see single pole mounting detail for hole sizes and locations. three pole ielh111 max. [76.58] 3.015 [19.05] .750 [19.05] .750 [19.05] .750 [76.96] 3.030 mounting detail* four pole ielh1111 mounting detail* bx - flat rocker handle the innovative new design of our ial/cel/lel bx style circuit protectors features a flat rocker that will satisfy your aesthetic needs while guarding against accidental actuation, providing the highest degree of circuit protection and quality. only airpax offers this new standard in user interface. available on a variety of versions with a full range of agency approvals, the iel bx style circuit protectors meet or exceed all current performance specifications, including interrupting capacities up to 50,000 amperes. 1.239 [31.47] .387 ref. [9.84] .768 [19.49] 1.859 [47.22] 2.490 max. [63.25] 2.173 max. [55.19] .314 [7.98] 1.395 [35.43] .125 [3.17] 6-32 thd. mounting m3 iso thd. optional 1.660 [42.16] .750 max. [19.05] optional guard (see detail c?) single pole 1.660 [42.16] .750 [19.05] 1.260 [32.00] .200 [5.08] 2x ?.156 [3.96] panel mounting detail mounting detail tolerance: .005 [.13] unless noted on i on i actuation access (see note) detail "a" on i o off on i o off on i o off on i off o handle position "off" guard with no actuate off feature (sixth decision, x) handle position "on" guard with no actuate off feature (sixth decision, x) push to reset note: access is limited to a device smaller than the underwriters laboratory "articulated probe" defined in ul-489 fig. 11.1.7.2.1. handle position "off" with guard (sixth decision, g) handle position "on" with guard (sixth decision, g) handle position "off" without guard handle position "on" without guard push to reset panel mounting detail tolerance .005 [.13] unless noted. ial series - handles ial series 136
the airpax? lelhp/celhp high current magnetic circuit protector compliments our entire series of lel circuit protectors. its un ique, parallel current sensing design provides precise current overload protection and reliability in the compact size of a two pole lel. the unit is ideal for high power dc applications such as drive motor systems and telecommunication power systems. lel is available in series and series with auxiliary switch configurations with a choice of delays for dc ratings of 125, 150, 175 and 200 amperes. the cel has been enhanced to include these same ratings plus a 4-pole, parallel 400 amp rating for ul489a. the lelhp is ul listed under the conditions of ul489 and csa certified. the celhp is ul listed under the conditions of ul489a. mid-trip handle indication, voltage trip and remote operator options complete the lelhp/celhp circuit breaker series. please see the individual product tables for approved ratings. series parallel on off [17.53] .690 [47.22] 1.859 [49.28] 1.940 [7.14] .281 [3.56] .140 [13.84] .545 [16.26] .640 [26.59] 1.047 [32.56] 1.282 [17.45] .687 1/4-20 stud (m6 x 1.0 stud option) [52.32] 2.060 [5.59] .220 [36.53] 1.438 [10.21] .402 [63.25] 2.490 [19.05] .750 2x 6-32 thread .140 [3.56] deep m3 iso thd optional c no nc breaker in off position series parallel with optional 1rec4 auxiliary switch notes: tolerance .015 [.39] unless noted. dimensions in brackets [ ] are millimeters. a terminal protrusion dimensions are referenced from back of mounting panel. b each screw terminal is supplied with a 10-32x.312[7.92] or m5 x 8mm screw, flatwasher and external tooth lockwasher. c stud terminals are supplied with a flatwasher, external tooth lockwasher and a 1 0-32 or m5 hex nut (<=70a), 1 /4 -20 or m6 hex nut (>70a). d units are supplied without bus bars must have a minimum copper strap (1 31/32 x 1/2 x 1/16 ) of appropriate length to accommodate connections tying each set of terminals together. e other spacing available upon request. contact factory for assistance. [6.60] .260 [2.79] .110 2.438 max [61.93] (see note 1) -rec4 [38.48] 1.5 15 max [18.80] .740 (note e) 32 32 [17.53] .690 [47.22] 1.859 6x 6x [49.28] 1.940 [7.14] .281 [3.56] .140 [6.40] .252 [36.53] 1.438 [10.21] .402 [63.25] 2.490 [57.53] 2.265 max. 6x [14.10] .555 [7.90] .311 [10.77] .424 [7.59] .299 [ 18.80 ] ( note e ) .740 [50.83] 2.001 off [3.61] .142 [17.45] .687 [13.84] .545 off off [32.77] 1.290 [16.46] .648 on off [52.32] 2.060 [5.59] .220 6x 1/4-20 stud 6x 6-32 thread .140 [3.56] deep m3 iso thd optional 1.055 [26.79] [ 18.80 ] ( note e ) .740 two pole three pole (note d) 175/200 parallel pole 32 32 [17.53] .690 [47.22] 1.859 6x 6x [49.28] 1.940 [7.14] .281 [3.56] .140 [6.40] .252 [36.53] 1.438 [10.21] .402 [63.25] 2.490 [57.53] 2.265 max. 6x [14.10] .555 [7.90] .311 [10.77] .424 [7.59] .299 [ 18.80 ] ( note e ) .740 [50.83] 2.001 off [3.61] .142 [17.45] .687 [13.84] .545 off off [32.77] 1.290 [16.46] .648 on off [52.32] 2.060 [5.59] .220 6x 1/4-20 stud 6x 6-32 thread .140 [3.56] deep m3 iso thd optional 1.055 [26.79] [ 18.80 ] ( note e ) .740 lelhp/celhp circuit protectors four pole (cel _ _ p and cml _ _ p only) 8x 6-32 thread .140 [3.56] deep m3 iso thd optional of ff fo ffo ffo 3.005 [76.33] .402 10.21 1.438 36.53 2.490 63.25 .220 5.59 2.060 52.32 (see table) dim. "h" (see table) dim. "h" (see table) dim. "h" max ial series - handles http://airpax.sensata.com 137
the laln/iuln family is a sealed toggle version of the ial/iul family. the silicone rubber seal around the handle assures panel seal integrity and makes this style a natural for harsh environments. this sealed toggle family is available in one to three pole models with ratings of .050 to 100 amperes. [34.92] 1.375 [16.66] .656 [63.25] 2.490 [19.05] .750 keyway .060 [1.52]-.065 [1.65] wide .030 [.76]-.035 [.89] deep [38.48] 1.515 (optional, handle may be in pole 2 instead of pole 1) max. [57.53] 2.265 max. three pole single pole two pole (optional handle may be in pole 2 instead of pole 1.) [13.08] ?.515 [3.96] ?.156 [16.66] .656 [19.05] .750 max. [19.05] .750 [19.05] .750 max. max. [51.82] 2.040 [3.30] .130 on off 6-32 mtg. screw 1/2-32 hex nut lockwasher [19.05] .750 [15.88] .625 [3.61] .142 for high shock mtg. optional handle notes: a terminal protrusion dimensions are referenced from back of mounting panel. b each screw terminal is supplied with a 10-32x.312[7.92] or m5 x 8mm screw, flatwasher and external tooth lockwasher. c stud terminals are supplied with a flatwasher, external tooth lockwasher and a 10-32 or m5 hex nut (<=70a), 1 /4 -20 or m6 hex nut (>70a). panel mounting details: tolerance .005 [.13] unless noted. single pole two pole* three pole* *see single pole mounting detail for hole sizes and locations. ialn/iuln panel seal circuit protectors ial series - handles ial series 138
two pole three pole four pole the rocker style is available in one to four poles. choose either vertical or horizontal mounting with on-off, international markings or a combination of both. five front panel enhancing colors including black, white, red, grey and orange are available. [47.22] 1.859 [57.12] 2.249 [10.65] .419 [34.92] 1.375 [63.25] 2.490 [49.28] 1.940 [3.61] note: tolerance .015 [.38] unless noted. dimensions in brackets [ ] are millimeters. off on [19.05] .750 [42.16] 1.660 [50.09] 1.972 [18.67] 2.361 2x 6-32 thd. (typ.) m3 iso thd. optional .735 (handle width) off on max. [38.07] 1.499 off on max. [57.12] 2.249 off on off on max. [76.58] 3.015 [19.05] .750 [42.17] 1.660 [3.96] 2x ? .156 1.260 [32.00] [5.08] .200 [38.35] 1.510 [19.05] .750 [32.00] 1.260 note: a terminal protrusion dimensions are referenced from back of mounting panel. b each screw terminal is supplied with a 10-32x.312[7.92] or m5 x 8mm screw, flatwasher and external tooth lockwasher. c stud terminals are supplied with a flatwasher, external tooth lock washer and a 10-32 or m5 hex nut (<=70a), o -20 or m6 hex nut (>70a). single pole panel mounting detail* single,two & three pole four pole** * mounting detail tolerance .005 [.13] unless noted. **see single mounting detail for hole sizes and locations. (optional handle may be in pole 2 instead of pole 1.) the ialzx/iulzx/ielzx style adds our rocker handle options of contrasting dual color rocker actuators, affording a clear visual indication of the handle position and integrated handle guards, to 1.239 [31.47] .420 ref [10.67] .750 max. [19.05] 2x 6-32 thd. m3 iso thd. optional on .506 [12.85] optional handle guards 1.660 [42.16] off .772 [19.62] panel mounting details mounting detail tolerance: .005 [.13] unless noted. 1.859 [47.22] 2.173 max. [55.19] .314 [7.98] .201 [5.11] 1.395 [35.43] 2.490 max. [63.25] 1.660 [42.17] .750 [19.05] 1.260 [32.00] 2x ? .156 [3.96] .200 [5.08] 1.239 [31.47] .420 ref [10.67] .750 max. [19.05] 2x 6-32 thd. m3 iso thd. optional on .506 [12.85] optional handle guards 1.660 [42.16] off .772 [19.62] panel mounting details mounting detail tolerance: .005 [.13] unless noted. 1.859 [47.22] 2.173 max. [55.19] .314 [7.98] .201 [5.11] 1.395 [35.43] 2.490 max. [63.25] 1.660 [42.17] .750 [19.05] 1.260 [32.00] 2x ? .156 [3.96] .200 [5.08] panel mounting detail help prevent accidental turn-on and turn-off of the unit. available with a black rocker and white, red or green indicator color for either on or off indication. ialx/iulx/ielx rocer handle ialzx/iulzx/ielzx rocer handle panel mounting detail tolerance .005 [.13] unless noted. ial series - handles http://airpax.sensata.com 139
series trip the most popular configuration for magnetic protectors is the series trip where the sensing coil and contacts are in series with the load being protected. the handle position conveniently indicates circuit status. in addition to providing conventional overcurrent protection, its simultaneously used as an on-off switch. shunt trip the shunt trip is designed for controlling two separate loads with one assembly. the control is established by providing overload protection for the critical load. when the current through this load becomes excessive and reaches the trip point, the protector will open and remove power from both loads simultaneously. the total current rating of both loads must not exceed the maximum contact rating. dual coil by combining two electrically independent coils on a common magnetic circuit, it is possible to provide contact opening when either an over-current or trip voltage is applied to the respective coils. one coil will be a current trip coil with standard specifications. the second, or dual coil, can be used to provide a control function permitting contact opening from a remote interlock or other transducer functions. standard coils are 6, 12, 24, 48, 120 and 240 volts. tripping is instantaneous and must be removed (usually self-interrupting) after trip. auxiliary switch (applies to series trip only) this is furnished as an integral part of a series pole in single or multi-pole assemblies. isolated electrically from the protectors circuit, the switch works in unison with the power contacts and provides indication at a remote location of the protectors on-off status. auxiliary switch contacts actuate simultaneously with the main breaker contacts, and will open regardless of whether the breaker contacts are opened manually or electrically. for auxiliary switch ratings below 6vac or 5vdc, an auxiliary switch with gold contacts, designated as reg is available. gold contacts are not recommended for load current above 100 milliamps. switch only series 1.940 [49.28] .281 [7.13] dimension b (see table) dimension a (see table) 1.290 [32.77] .648 [16.46] 1.055 [26.80] nc no c breaker in off position 1.26 [32.00] .278 [7.05] 1.940 [49.28] 2.640 max. [67.06] (see note a) .795 [20.19] .660 .045 [16.76] 1.14] 1.266 [32.16] .971 [24.66] .676 [17.17] dimension b (see table) -irec5 .250 [6.35] .187 [4.75] -irec4, -ireg4 .260 [6.60] .110 [2.79] 2.454 max. [64.52] (see note a) 2.438 max. [64.52] (see note a) -irec5 .250 [6.35] .187 [4.75] -irec4, -ireg4 .260 [6.60] .110 [2.79] 2.454 max. [64.52] (see note a) 2.438 max. [64.52] (see note a) dual coil shunt spacing for vde switch series with auxiliary switch [17.17] .676 [24.66] .971 [32.16] 1.266 note: each outer terminal is supplied with a flatwasher, tooth lockwasher and a hex nut. note: a terminal protrusion dimensions are referenced from back of mounting panel. b each screw terminal is supplied with a 10-32x.312[7.92] or m5 x 8mm screw, flatwasher and external tooth lockwasher. c stud terminals are supplied with a flatwasher, external tooth lock washer and a 10-32 or m5 hex nut (<=70a), 1/4-20 or m6 hex nut (>70a). series and switch only shunt and dual coil configurations stud terminal types screw stud thread dimension a dimension b m6 .510 .045 [12.95 1.14] .652 .035 [16.56 0.89] 1/4 -20 .545 .045 [13.84 1.14] .687 .035 [17.45 0.89] m5 .510 .045 [12.95 1.14] .652 .035 [16.56 0.89] 10-32 .545 .045 [13.84 1.14] .687 .035 [17.45 0.89] ial series - confgurations ial series 140
relay trip this permits the overload sensing coil to be placed in a circuit which is electrically isolated from the trip contacts. the coil may be actuated by sensors monitoring pressure, flow, temperature, speed, etc. other typical applications include crowbar, interlock and emergency/rapid shutdown circuitry. trip may be accomplished by voltage or current, which must be removed after trip. voltage trip sometimes called dump circuits or panic trip circuits, these units make it possible to open main power contacts with lower power inputs from one or more sources. this configuration is becoming increasingly more important for sensitive circuitry and denser packaging in automation systems. available in series, shunt or relay configurations. [18.34] .722 [33.78] 1.330 [7.14] .281 [16.76 1.14] .660 .045 [49.28] 1.940 (see note a) [67.06] 2.640 max [20.19] .795 relay dual coil relay and dual coil notes: tolerance .015 [.39] unless noted. dimensions in brackets [ ] are millimeters. a terminal protrusion dimensions are referenced from back of mounting panel. b each screw terminal is supplied with a 10-32x.312[7.92] or m5 x 8mm screw, flatwasher and external tooth lockwasher. c stud terminals are supplied with a flatwasher, external tooth lockwasher and a 1 0-32 or m5 hex nut (<=70a), 1/4 -20 or m6 hex nut (>70a). relay dual coil barriers [69.60] 2.740 [17.02] .670 [27.89] 1.098 [65.02] 2.560 [29.13] 1.147 [18.31] .721 [65.02] 2.560 [29.13] 1.147 [18.31] .721 [.84] .033 [78.74] 3.100 [35.00] 1.378 [24.18] .952 [7.69] .303 [3.11] .122 [.84] .033 note: this barrier can be flipped to cover either pole. please contact factory for specific part number fig.4 fig.3 fig.2 fig.1 configurations (cont.) barrier options rating option standard barrier optional barrier iel 240/415 vac fig. 1 fig. 2, 3 & 4 415 vac (vde) 277/480 vac 1/4-20, m6 studs for ac 120/240 vac multi-pole fig. 2 fig. 3 & 4 125vdc lel all multi-pole 50/60 hz fig. 2 fig. 3 & 4 all multi-pole 80 vdc, if opposite polarity fig. 2 fig. 3 & 4 125vdc fig. 2 fig. 3 & 4 note: optional barrier available with factory assigned part number. contact factory for assistance. ial series - confgurations http://airpax.sensata.com 141
mid-trip indication circuit protection, rapid fault location and alarm capability are blended together in the airpax mid-trip indication option. this option is designed for automatic handle movement to a middle position upon electrical overload, allowing for easier detection of the fault circuitand minimizing downtime due to the overload condition. in the optional auxiliary switch configuration, the switch allows an alarm or signal to be forwarded when the breaker trips and the handle moves to the middle position. the alarm can be disengaged by the manual actuation of the handle to the off position. once the fault has been corrected, the circuit breaker can be reset to the on position. the mid-trip option is available in one, two or three pole toggle handle packages and in either standard panel screw or snap-in mounting. please see specification tables of specific product for available ratings. snap-in mounting the snap-in mounting adapter allows for simplified mounting of most iel/lel toggle handle products. prior to shipment, the adapter is attached to the circuit breaker during our final product assembly, allowing you to securely snap the unit into a rectangular panel cut-out. this eliminates the need for panel mounting hardware and associated assembly costs. available for units up to three poles, with or without an option handle guard. c no nc c no nc breaker in on or manually turned off position breaker in mid-trip position (electrically tripped) on position off position mid-trip position (see table) [74.63 .18] 2.938 .007 dim.a? [52.35] 2.061 [25.27] .995 [81.79] 3.220 [44.45] 1.750 [63.37] 2.495 [17.45] .687 [39.62] 1.560 mid-trip handle positions panel mounting detail note: tolerance .015 [.39] unless noted. dimensions in brackets [ ] are millimeters. panel mounting options # of poles dimension a panel thickness 1 pole .760 .007 [19.30 .18] .062 .005 [1.57 .13] 2 pole 1.530 .007 [38.86 .18] .062 .005 [1.57 .13] 3 pole 2.280 .007 [57.91 .18] .062 .005 [1.57 .13] panel mounting detail tolerance .005 [.13] unless noted. ial series - confgurations ial series 142
http://airpax.sensata.com/ ial/cel/lel series - operating characteristics 149 operating characteristics nominal dcr /impedance current ratings (amps) resistance (ohms) impedance (ohms) impedance (ohms) dc delays ac, 50/60hz delays ac, 400hz delays 51, 52, 53, 59 61, 62, 63, 69 41, 42, 43, 49 0.20 45.8 28.5 71.94 1.0 1.38 1.10 2.85 2.0 0.371 0.29 0.76 5.0 0.055 0.051 0.12 10.0 0.017 0.016 0.032 20.0 0.006 0.006 0.010 30.0 0.003 0.004 0.006 50.0 0.0019 0.0018 0.0019 60.0 0.00157 0.00134 70.0 0.00147 0.00133 80.0 0.00146 0.00123 90.0 0.00135 0.00114 100.0 0.00135 0.00114 125.0 0.0005 150.0** 0.0005 165.0** 0.0004 175.0** 0.0004 200.0** 0.0004 250.0** 0.0004 400** 0.0003 notes: dcr and impedance based on 100% rated current applied and stablized a minimum of one hour. no 53 delay on 125 amp single pole or 400 amp four pole devices tolerance: .02 amperes to 2.5 amperes, 20%; 2.6 amperes to 20 amperes, 25%; 21 amperes to 50 amperes, 50%. consult factory for special values and for coil impedance of delays not shown ** paralleled poles only, 400 amps only available on celhp ial series - operating characteristics http://airpax.sensata.com 143
http://airpax.sensata.com/ ial/cel/lel series - operating characteristics 150 percentage of rated current vs trip time in seconds at +25c delay 100% 125%* 150% 200% 400% 600% 800% 1000% 41* no trip may trip .5 to 8 .15 to 1.9 .02 to .4 .006 to .25 .004 to .1 .004 to .05 42* no trip may trip 5 to 70 2.2 to 25 .40 to 5 .012 to 2 .006 to .2 .006 to .15 43* no trip may trip 35 to 350 12 to 120 1.5 to 20 .012 to 2.2 .01 to .22 .01 to .1 49* no trip may trip .100 max. .050 max. .020 max. .020 max. .020 max. .020 max. 51 no trip .5 to 6.5 .3 to 3 .1 to 1.2 .031 to .5 .011 to .25 .004 to .1 .004 to .08 52 no trip 2 to 60 1.8 to 30 1 to 10 .15 to 2 .04 to 1 .008 to .5 .006 to .1 53** no trip 80 to 700 40 to 400 15 to 150 2 to 20 .23 to 9 .015 to .55 .012 to .2 59 no trip .120 max. .100 max. .050 max. .022 max. .017 max. .017 max. .017 max. 61 no trip .7 to 12 .35 to 7 .130 to 3 .030 to 1 .015 to .3 .01 to .15 .008 to .1 62 no trip 10 to 120 6 to 60 2 to 20 .2 to 3 .02 to 2 .015 to .8 .01 to .25 63 no trip 50 to 700 30 to 400 10 to 150 1.5 to 20 .4 to 10 .013 to .85 .013 to .5 69 no trip .120 max .100 max. .050 max. .022 max. .017 max. .017 max. .017 max 71 no trip .44 to 10 .3 to 7 .100 to 3 .030 to 1 .012 to .3 .004 to .15 .004 to .1 72 no trip 1.8 to 100 1.7 to 60 1 to 20 .15 to 3 .015 to 2 .008 to .79 .006 to .28 73 no trip 50 to 600 30 to 400 10 to 150 1.8 to 20 .015 to 10 .015 to .88 .011 to .5 79 no trip .120 max .100 max. .050 max. .023 max. .016 max. .015 max. .015 max notes: all trip curves and trip currents are specifed with the protector mounted in the normal vertical position at ambient temperature of +25 c. protectors do not carry current prior to application of overload. a: ratings above 30 amps may deviate from the above limits by approximately 10% (130% for delay 49). * no 53 delay on 125 amp single pole or 400 amp four pole devices * 135% for delay 71, 72, 73 & 79 ial series - operating characteristics ial series 144
800 700 600 500 400 300 200 150 125 100 0 time in seconds 10 1 .1 1000 100 .01 10000 .001 percent of rated current 1000 900 delay 61 may trip 800 700 600 500 400 300 200 150 125 100 0 time in seconds 10 1 .1 1000 100 .01 10000 .001 percent of rated current 1000 900 delay 62delay 62 delay 62 may trip 800 700 600 500 400 300 200 150 125 100 0 time in seconds 10 1 .1 1000 100 .01 10000 .001 percent of rated current 1000 900 delay 63 may trip 800 700 600 500 400 300 200 150 125 100 0 time in seconds 10 1 .1 1000 100 .01 10000 .001 percent of rated current 1000 900 delay 69 may trip 400hz, dc, 50/60hz delay curves (typ) a choice of delays is offered for dc, 50/60hz, 400hz, or combined dc/50/60hz applications. delays 49, 59, 69 and 79 provide fast-acting, instantaneous tripping and are often used to protect sensitive electronic equipment (not recommended where a known inrush exists). delays 41, 51, 61 and 71 have a short delay for general purpose applications. delays 42, 52, 62 and 72 are long enough for most transformers and capacitor loads. delays 43, 53, 63 and 73 are extra long for special motor applications. inrush pulse tolerance pulse tolerance is defined as a single pulse of half sine wave peak current amplitude of 8 milliseconds duration that will not trip the circuit breaker. the table on page 171 provides a guide to determine if the inertia delay feature is required. consult factory for further assistance. 800 700 600 500 400 300 200 150 125 100 0 time in seconds 10 1 .1 1000 100 .01 10000 .001 percent of rated current 1000 900 delay 61 may trip 800 700 600 500 400 300 200 150 125 100 0 time in seconds 10 1 .1 1000 100 .01 10000 .001 percent of rated current 1000 900 delay 62delay 62 delay 62 may trip 800 700 600 500 400 300 200 150 125 100 0 time in seconds 10 1 .1 1000 100 .01 10000 .001 percent of rated current 1000 900 delay 63 may trip 800 700 600 500 400 300 200 150 125 100 0 time in seconds 10 1 .1 1000 100 .01 10000 .001 percent of rated current 1000 900 delay 69 may trip delay curves http://airpax.sensata.com/ ial/cel/lel series - operating characteristics 149 ial series - delay curves http://airpax.sensata.com 145
dc delay curves (typ) 800 700 600 500 400 300 200 150 125 100 0 10 1 .1 1000 100 .01 10000 .001 percent of rated current 1000 900 delay 51 may trip 800 700 600 500 400 300 200 150 125 100 0 time in seconds 10 1 .1 1000 100 .01 10000 .001 percent of rated current 1000 900 delay 52 may trip 800 700 600 500 400 300 200 150 125 100 0 time in seconds 10 1 .1 1000 100 .01 10000 .001 percent of rated current 1000 900 delay 53 may trip 800 700 600 500 400 300 200 150 125 100 0 time in seconds 10 1 .1 1000 100 .01 10000 .001 percent of rated current 1000 900 delay 59 may trip time in seconds pulse tolerances delay pulse tolerance 61, 62, 63, 71, 72, 73 10 times (approx.) rated current 61f, 62f, 63f, 71f, 72f, 73f 12 times (approx.) rated current 64, 65, 66 (0 - 50a) 25 times (approx.) rated current 64, 65, 66 (>50 - 80a) 20 times (approx.) rated current 64, 65, 66 (>80 - 100a) 18 times (approx.) rated current http://airpax.sensata.com/ ial/cel/lel series - operating characteristics 150 ial series - delay curves ial series 146
400hz delay curves (typ) *available only in ial/iul/iel; not available in lel. 800 700 600 500 400 300 200 150 125 100 0 10 1 .1 1000 100 .01 10000 .001 percent of rated current 1000 900 delay 41 may trip 800 700 600 500 400 300 200 150 125 100 0 time in seconds 10 1 .1 1000 100 .01 10000 .001 percent of rated current 1000 900 delay 42 m ay trip 800 700 600 500 400 300 200 150 125 100 0 time in seconds 10 1 .1 1000 100 .01 10000 .001 percent of rated current 1000 900 delay 43 may trip 800 700 600 500 400 300 200 150 130 100 0 time in seconds 10 1 .1 1000 100 .01 10000 .001 percent of rated current 1000 900 delay 49 m ay trip time in seconds http://airpax.sensata.com/ ial/cel/lel series - operating characteristics 149 ial series - delay curves http://airpax.sensata.com 147
delay 79 800 700 600 500 400 300 200 150 135 100 0 time in seconds 10 1 .1 1000 100 .01 10000 .001 percent of rated current 1000 900 m ay trip 800 700 600 500 400 300 200 150 135 100 0 time in seconds 10 1 .1 1000 100 .01 10000 .001 percent of rated current 1000 900 delay 71 800 700 600 500 400 300 200 150 135 100 0 time in seconds 10 1 .1 1000 100 .01 10000 .001 percent of rated current 1000 900 delay 73 800 700 600 500 400 300 200 150 135 100 0 time in seconds 10 1 .1 1000 100 .01 10000 .001 percent of rated current 1000 900 m ay trip delay 72 may trip m ay trip dc/50/60hz dual-frequency delay curves (typ) http://airpax.sensata.com/ ial/cel/lel series - operating characteristics 150 ial series - delay curves ial series 148
ial/iul/iel/idl/lel specifications trip free will trip open on overload even when forcibly held in the on position. this prevents the operator from damaging the circuit by holding the breaker on. trip indication the operating handle moves positively to the off or mid-trip position on electrical overload. ambient operation ial/iul/iel protectors operate in temperatures between C40c to +85c. insulation resistance not less than 100 megohms at 500 volts dc. dielectric strength ial/iul/iel protectors withstand 3750vac (1250vac for lel), 60hz for 60 seconds between all electrically isolated terminals except auxiliary switch terminals shall withstand 600vac, 60hz for reg and rec types. four terminal dual coil and relay con - struction (not offered in the lel) will withstand 1500vac. endurance operating as a switch, the operating life exceeds 10,000 oper - ations, 6000 at rated load, 4000 without load, at a rate of 6 per minute. electrical characteristics .050-100 amperes 80vdc, 240vac max., 240/415vac at 50 amperes max., 50/60hz and 400hz. consult factory for specific product ratings. units rated for 240/415vac and above 50 amperes are not suitable for across-the-line motor starting. poles one through six poles available. construction series, shunt, relay dual coil and series with auxiliary switch available in various delays and combinations. auxiliary switch when supplied shall be s.p.d.t. configuration. non vde approved switches have a maximum ul rating of 10.0 amperes, 250 volts, 60hz; 3.0 amperes, 50 volts dc (rec type) or 0.1 amperes, 125 volts, 60hz (reg type). vde approved switches have a maximum ul rating of 10.0 amperes, 250 volts, 60hz (rec type); or 0.1 amperes, 125 volts, 60hz (reg; type). the maximum vde ratings are 1.0 amperes, 125 volts, 60hz (rec type); 0.1 amperes, 125 volts, 60hz (reg type). salt spray (corrosion) meet the requirements of mil-prf-55629 when tested in accordance with method 101 of mil-std-202. moisture resistance meet all the requirements of mil-prf-55629 when tested in accordance with method 106 of mil-std-202. shock circuit protectors shall not trip when tested per mil-std-202, method 213, test condition i with 100% rated current applied to delayed units and 80% rated current to instantaneous units. vibration circuit protectors shall not trip when vibrated per mil- std-202, method 204, test condition a with 100% rated current applied to delayed units and 80% rated current to instantaneous units. ul-1500 (marine ignition protected) the idl/idlh is approved for marine ignition protection (series configuration only), covering ignition protected circuit break - ers. this specification requires devices to be used in accordance with the requirementsof u.s. coast guard and fire protection standard for pleasure and commercial motor craft, ansi/mfpa #302. approximate weight per pole ounces grams 3.1 90 recommended torque specifications component torque (in-lbs) 6-32 mounting inserts 6 to 8 m3 mounting screws 4 to 5 10-32 screw terminals 14 to 15 m5 terminal screws 14 to 15 10-32 stud terminals 13 to 14 m5 stud terminals 13 to 14 1/4 - 20 stud terminals 40 to 45 m6 stud terminals 40 to 45 1/2 - 32 mounting bushing 30 to 35 where applicable, mechanical support must be provide to the terminals when applying torque http://airpax.sensata.com/ ial/cel/lel series - operating characteristics 149 ial series - specifcations http://airpax.sensata.com 149
agency approvals - ial/iul/iel voltage frequency (hz) phase min. poles tc ol ul/csa vde (amps) ul 1077 & csa (aic) vde (aic) 65 dc - 1 1 1 .02-100 .10-70 u2, 7500 4000 65(4) dc - 1 1 1 .02-100 - u2, 3000 - 65(4) dc - 1 1 1 .02-50 - u2, 5000 - 65 dc - 2** 2 1 101-150 - u2, 7500 - 80 dc - 1 1 1 .02-70 .10-50 u2, 7500 4000 80 dc - 1 1 1 70.1-100 - u2, 5000 - 80 dc - 2 1 1 101-150 - u1, 10000 - 80 dc - 3 1 0 251-300 - u2, 7500 - 125 dc - 2 1 0 .02-100 - u2, 5000 - 250 dc - 2+ 1 0 .02-50 - u1, 5000 - 300 dc - 3++ 1 0 .02-50 .10-50 u2, 1000 5000 125 50/60 1 1 1 0 .02-70 - u2, 5000 - 125 50/60 1 1 1 1 .02-100 - u1, 3000 - 125(5) 50/60 1 1 1 1 .02-100 - u3, 1500 - 120/240 50/60 1 2 2 1 .02-100 - u1, 2000 - 125/250(5) 50/60 1 2 only 1 1 .02-100 - u3, 1500 - 240 50/60 1&3 1 1 0 .02-70 - u1, 2000 - 240 50/60 3 2 1 1 .02-100 - u2, 2000 - 250 50/60 3 1 1 1 .02-50 .10-100 u2, 3000 2000 250 50/60 3 1 1 1 .02-50 .10-100 c2, 5000(1) 2000 250 50/60 1 1 1 1 .02-50 .10-100 c2, 5000(2) 2000 250 50/60 3 2 1 0 .02-80 .10-100 u1, 1000 2000 250 50/60 3 1 1 0 .02-60 .10-100 u1, 5000 2000 250(5) 50/60 3 3 only 1 1 .02-100 - u3, 2000 - 277 50/60 1 1 1 1 .02-50 - u2, 2000 - 277 50/60 1&3 1 2 1 .02-50 - c2, 5000(1) - 240/415 50/60 3 2 2 0 .02-50 .10-50 u2, 2000 2000 240/415 50/60 1 2 2 0 .02-50 .10-50 c2, 5000(1) 2000 277/480 50/60 3 2 2 1 .02-30 - u2, 2000 - 277/480 50/60 3 2 2 1 .02-50 - u2, 1200 - 277/480 50/60 3 2 1 1 .02-30 - c2, 5000(3) - 277480 50/60 1&3 2 1 0 .02-50 - c2, 5000(3) - 480 50/60 1&3 2 1 1 .02-30 - c2, 5000(3) - 480 50/60 3 2 1 0 .02-50 - c2, 5000(3) - 250 400 1&3 1 2 1 .02-50 - u2, 1500 - agency approvals - cel/celp (communications) voltage frequency (hz) phase min. poles ul/csa vde (amps) ul 489a (aic) vde (aic) 65 dc - 1 .05-50 - 7500 - 65 dc - 2** 101-150 - 50000 - 80 dc - 1 .05-100 - 50000 - 80 dc - 2** 101-200 - 10000 - 80 dc - 3** 201-250 - 10000 - 125 dc - 1 .05-70 - 5000 - 80 dc - 1 125 - 10000 - general notes: ? all supplementary protectors are of the overcurrent (oc) type ? the family of protectors has been evaluated for end use application for use groups (ug) a, b, c and d ? the terminals (fw) are suitable for factory wiring only (0) ? the maximum voltage ratings for which the protectors have been tested are shown in the chart ? the current is the amperage range that the protectors have been tested ? the tripping current (tc) for all of the protectors is either either 1 (in the range of 125% to 135% of ampere rating) or 2 (more than 135% of ampere rating) ? the overload rating (ol) C designates whether the protector has been tested for general use or motor starting applications. 0 C tested at 1.5 times amp rating for general use 1 C tested at 6 times ac rating or 10 times dc rating for motor starting ? the short circuit current rating (sc) C the short circuit rating in amperes following a letter and number designating the test conditions and any calibration following the short circuit test is defined below: c C indicates short circuit test was conducted with series overcurrent protection u C indicates short circuit test was conducted without series overcurrent protection 1 C indicates a recalibration was not conducted as part of the short circuit testing 2 C indicates a recalibration was performed as part of the short circuit testing 3 C indicates recalibration was performed along with the dielectric and voltage withstand for suitable for further use rating agency approvals - iuld (dust sealed) voltage frequency (hz) phase min. poles tc ol ul/csa vde (amps) ul 1077 & csa (aic) vde (aic) 250 50/60 1&3 1 1 1 .02-100 - c2, 5000(3) - 277 50/60 1 1 1 1 .02-30 - c2, 5000(3) - notes: ** paralleled poles; + 2 poles in series; ++ 3 poles in series; (1) with 125 a max. series fuse; (2) series combination with 209 or 229 series (100 a max.); (3) with 100 a max. series fuse; (4) with blocked vent construction (5) non-standard construction. fit for further use approval ial/iul/iel/idl/lel/lelhp specifications agency approvals - lel/lelhp voltage frequency (hz) phase min. poles ul/csa vde (amps) ul489 (aic) vde (aic) 65 dc - 1 .05-50 - 7500 - 65 dc - 2** 101-150 - 50 000 - 65 dc - 3** 175-200 - 50000 - 80 dc - 1 .05-100 .10-100 10000 2000 80 dc - 1 .05-100 - 50000 - 80 dc - 2** 125-150 125-150 10000 2000 80 dc - 3** 175-200 151-200 10000 2000 125 dc - 1 .05-70 .05-70 5000 3000 125/250 dc - 2 .05-50 - 5000 - 125 50/60 1&3 1 .05-40 - 10000 - 125 50/60 1&3 1 .05-50 .10-50 5000 2000 120/240 50/60 1 2 .05-70 .10-50 5000 2000 240 50/60 1&3 1 .05-20 - 5000 - agency approvals - celhp 80 dc - 4 400 - 10000 aic (ul489a) - agency approvals - idl/idlp (marine) voltage frequency (hz) phase min. poles tc ol ul/csa vde (amps) ul 1077 & csa (aic) vde (aic) 48 dc - 1 1 1 .02-100 - u1, 5000 - 48 dc - 2** 1 1 101-150 - u1, 5000 - 65 dc - 1 1 1 .02-60 - u1, 1000 - 80 dc - 1 1 1 .02-100 - u2, 1500 - 125 50/60 1 1 1 1 .02-100 - u 1, 1500 - 250 50/60 1 2 1 1 .02-100 - u2, 1500 - 250 50/60 1&3 1 1 1 .02-60 - u1, 1000 - agency approvals - iulq (tapped coil) voltage frequency (hz) phase min. poles tc ol ul/csa vde (amps) ul 1077 & csa (aic) vde (aic) 125/250 50/60 1 1 1 1 2/1-30/15 - c2, 5000(1) - http://airpax.sensata.com/ ial/cel/lel series - operating characteristics 150 ial series - specifcations ial series 150
ial/iul/iel decision tables the ordering code for ial/iul/iel/lel circuit protectors may be determined by following the decision steps in the appropriate part number decision table subsequent to this page. the coding given permits a self-assigning part number but with certain limitations. special applications may require a factory assigned part number. typical examples are units with mixed ratings, combinations of styles, or constructions not listed in the third decision table, etc. with these, it is suggested that order entry be by description and/or drawings, and a part number will be established. additionally, it is standard policy to establish a factory- assigned part number whenever a descriptive drawing exists to provide cross reference, traceability and manufacturing control. when specifying a circuit breaker for ac motor start or high inrush applications, the peak amplitude and surge duration should be specified for factory assistance in rating selection. for example the code shown is the code for a single pole breaker with a series construction and auxiliary switch, designed for operation in a 50/60hz circuit. it has a short time delay, rating of 20 amperes and a marked black handle, and is vde approved. to determine the ordering number for your particular ial/iul/iel unit, simply follow the steps shown. you may use this number to place an order or as a reference for further questions you may have. notes: iel, ielh and ielx circuit protectors are designed to meet 8mm creepage clearance requirements for installation category 111, pollution degree 3, case a as measured in iec 664. intended for use in equipment to comply with iec 950, 601 and vde 0804 & 0805. second decision single pole two pole three pole four pole* 1 11 111 1111 2 poles *not available in toggle seal handle type. consult factory for 5 and 6 pole iel part number. internal conguration third decision 3 * only one auxiliary switch is normally supplied on two or three pole units. switch is located in the right-hand pole (viewed from terminal end) unless otherwise specied. 1 2 3 4 iel 1 - 1rec4- 61- 20.0 - 01 - v 5 7 example: black yellow red blue green orange white -00 -10 -20 -30 -40 -60 -90 -01 (std) -11 -21 -31 -41 -61 -91 seventh decision 7 handle color and marking selection ial, iul, iel, ialh, iulh, ielh - toggle handle marked* on-off color unmarked i-o fifth decision 5 rated current use three numbers to print required current value between .100 amps minimum and 100 amps maximum. for example, use: .100 or 2.00 or 10.0 the vde (lth) will be 95% of the ul/csa rated current. fourth decision 4 frequency & delay switch only 400hz short delay 400hz long delay 400hz motor start 400hz 150% instant trip dc short delay dc long delay dc motor start dc 125% instant trip 50/60hz short delay 50/60hz long delay 50/60hz motor start 50/60hz 125% instant trip dc/60hz short delay dc/60hz long delay dc/60hz motor start dc/60 hz 135% instant trip for addition of inertial delay, add an f? to any delay numeral. sw -41 -42 -43 -49 -51 -52 -53 -59 -61 -62 -63 -69 - 71 - 72 -73 -79 notes: a. bezels of ialbx, iulbx, ielb, ielbx are black. b. consult factory for other marking options. note: ccc approval is pending. black red grey orange white -00 -20 -40 -50 -90 -01 -21 -41 -51 -91 -02 -22 -42 -52 -92 -03 -23 -43 -53 -93 -04 -24 -44 -54 -94 -05 -25 -45 -55 -95 -06 -26 -46 -56 -96 i-o fig.2 unmarked marking detail seventh decision 7 rocker handle color, indicator color and marking selection (see notes) ialx, iulx, ielx, ialzx, iulzx, ielzx rocker handle (single rocker color) rocker handle color indicating color marking color indicates: on-off fig.1 on-off i-o fig.3 on-off i-o fig.6 i-o fig.5 on-off fig.4 a vertical mounting horizontal mounting n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a black black black white red green white white white on on on -j0 -k0 -l0 -j1 -k1 -l1 -j2 -k2 -l2 -j3 -k3 -l3 -j4 -k4 -l4 -j5 -k5 -l5 -j6 -k6 -l6 b c w hite white black black black ialzx, iulzx, ielzx rocker handle (dual rocker color) black black black black black black white red green white red green white white white white white white on on on off off off -a0 -b0 -c0 -f0 -g0 -h0 -a1 -b1 -c1 -f1 -g1 -h1 -a2 -b2 -c2 -f2 -g2 -h2 -a3 -b3 -c3 -f3 -g3 -h3 -a4 -b4 -c4 -f4 -g4 -h4 -a5 -b5 -c5 -f5 -g5 -h5 -a6 -b6 -c6 -f6 -g6 -h6 black black black black white red green yellow white red green yellow off off off off -m0 -n0 -p0 -r0 n/a n/a n/a n/a -m2 -n2 -p2 -r2 -m3 -n3 -p3 -r3 n/a n/a n/a n/a -m6 -n6 -p6 -r6 n/a n/a n/a n/a a ialbx, iulbx, ielbx, lelbx rocker handle (dual rocker color) ialbx **iulbx *** i elbx **imlbx one handle per unit one handle per pole one handle per unit panel seal one handle per unit, rocker, bracket mounting one handle per unit, rocker, integral mounting o ne handle per unit ul 1500 o ne handle per pole ul 1500 one handle per unit mid trip indication one handle per pole mid trip indication one handle per unit, rocker, accidental-off protection one handle per unit, mid trip indication, rocker, accidental-off protection *ul recognized **ul recognized, csa certied ***ul recognized, csa certied, vde approved *** iml *** imlh select type and terminal first decision 1 ial **iul *** iel ialh **iulh *** ielh ialn *** iuln ialx **iulx *** ielx ialzx **iulzx *** ielzx * idl * id lh type terminal standard screw terminal, no designation required stud terminals clip terminals bullet terminals k c b sixth decision 6 notes: 1. one or more descriptions may be used as required. 2. when this is not used, table one may be substituted and u.s. thread and two lockwashers will be supplied. unit will be rated at 250v (50/60hz only.) 3. vde approved at 250vac 4. vde approved at 415 vac -a -b -c -d -e -g -k -l -m -p -u -w -x -1 -2 standard hardware. no designation required. metric thread mounting inserts and terminals barrier 277v (50/60hz only) ( see note 3 ) 240/415v (50/60hz only) 277v/480v (50/60hz only) ( see note 4 ) handle guard, (available in zx, bx and snap-in versions only) 1/4 - 20 stud (m6 stud when -a option is selected) (<=70a requires -k, if >70a do not use -k) handle lock handle in opposite pole snap-in face plate adapter 120/240v 50/60hz wire clamp supplied (vde approved up to and including 16.0 amps) handle guard with no actuation feature (bx rocker only) silver 5/16" (.312") bullet gold 5/16" (.312") bullet optional the shaded areas denote vde and ccc (if applicable) approval options. this approval requires the addition of a v at the end of the part number. the v will be added to any part number formed entirely from shaded decisions. if non-shaded areas are selected, the unit will not be vde or ccc approved, but other approvals still apply. v = vde and ccc approved description note: ccc approval is pending. -0 -1 -1rec4 -1rec5 -1reg4 -1rs4 -1rls4 -1rs5 -3 -4 switch only (50, 70 or 100 amp switch) series series with auxiliary switch* .110 quick connect series with auxiliary switch* .187 quick connect series with auxiliary switch .110 quick connect series with alarm switch, electrical trip, .110 quick connect terminals series with alarm switch, electrical trip, .110 quick connect terminals (mid-trip only) series with alarm switch, electrical trip, .187 quick connect terminals shunt relay (not available in iel/ielx) this approval requires the addition of a c at the end of the part number. the unit will not be vde approved. c = ccc approved ial series - decision tables http://airpax.sensata.com 151
second decision single pole two pole three pole four pole* 1 11 111 1111 2 poles *not available in toggle seal handle type. consult factory for 5 and 6 pole iel part number. internal conguration third decision 3 * only one auxiliary switch is normally supplied on two or three pole units. switch is located in the right-hand pole (viewed from terminal end) unless otherwise specied. 1 2 3 4 iel 1 - 1rec4- 61- 20.0 - 01 - v 5 7 example: black yellow red blue green orange white -00 -10 -20 -30 -40 -60 -90 -01 (std) -11 -21 -31 -41 -61 -91 seventh decision 7 handle color and marking selection ial, iul, iel, ialh, iulh, ielh - toggle handle marked* on-off color unmarked i-o fifth decision 5 rated current use three numbers to print required current value between .100 amps minimum and 100 amps maximum. for example, use: .100 or 2.00 or 10.0 the vde (lth) will be 95% of the ul/csa rated current. fourth decision 4 frequency & delay switch only 400hz short delay 400hz long delay 400hz motor start 400hz 150% instant trip dc short delay dc long delay dc motor start dc 125% instant trip 50/60hz short delay 50/60hz long delay 50/60hz motor start 50/60hz 125% instant trip dc/60hz short delay dc/60hz long delay dc/60hz motor start dc/60 hz 135% instant trip for addition of inertial delay, add an f? to any delay numeral. sw -41 -42 -43 -49 -51 -52 -53 -59 -61 -62 -63 -69 - 71 - 72 -73 -79 notes: a. bezels of ialbx, iulbx, ielb, ielbx are black. b. consult factory for other marking options. note: ccc approval is pending. black red grey orange white -00 -20 -40 -50 -90 -01 -21 -41 -51 -91 -02 -22 -42 -52 -92 -03 -23 -43 -53 -93 -04 -24 -44 -54 -94 -05 -25 -45 -55 -95 -06 -26 -46 -56 -96 i-o fig.2 unmarked marking detail seventh decision 7 rocker handle color, indicator color and marking selection (see notes) ialx, iulx, ielx, ialzx, iulzx, ielzx rocker handle (single rocker color) rocker handle color indicating color marking color indicates: on-off fig.1 on-off i-o fig.3 on-off i-o fig.6 i-o fig.5 on-off fig.4 a vertical mounting horizontal mounting n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a black black black white red green white white white on on on -j0 -k0 -l0 -j1 -k1 -l1 -j2 -k2 -l2 -j3 -k3 -l3 -j4 -k4 -l4 -j5 -k5 -l5 -j6 -k6 -l6 b c w hite white black black black ialzx, iulzx, ielzx rocker handle (dual rocker color) black black black black black black white red green white red green white white white white white white on on on off off off -a0 -b0 -c0 -f0 -g0 -h0 -a1 -b1 -c1 -f1 -g1 -h1 -a2 -b2 -c2 -f2 -g2 -h2 -a3 -b3 -c3 -f3 -g3 -h3 -a4 -b4 -c4 -f4 -g4 -h4 -a5 -b5 -c5 -f5 -g5 -h5 -a6 -b6 -c6 -f6 -g6 -h6 black black black black white red green yellow white red green yellow off off off off -m0 -n0 -p0 -r0 n/a n/a n/a n/a -m2 -n2 -p2 -r2 -m3 -n3 -p3 -r3 n/a n/a n/a n/a -m6 -n6 -p6 -r6 n/a n/a n/a n/a a ialbx, iulbx, ielbx, lelbx rocker handle (dual rocker color) ialbx **iulbx *** i elbx **imlbx one handle per unit one handle per pole one handle per unit panel seal one handle per unit, rocker, bracket mounting one handle per unit, rocker, integral mounting o ne handle per unit ul 1500 o ne handle per pole ul 1500 one handle per unit mid trip indication one handle per pole mid trip indication one handle per unit, rocker, accidental-off protection one handle per unit, mid trip indication, rocker, accidental-off protection *ul recognized **ul recognized, csa certied ***ul recognized, csa certied, vde approved *** iml *** imlh select type and terminal first decision 1 ial **iul *** iel ialh **iulh *** ielh ialn *** iuln ialx **iulx *** ielx ialzx **iulzx *** ielzx * idl * id lh type terminal standard screw terminal, no designation required stud terminals clip terminals bullet terminals k c b sixth decision 6 notes: 1. one or more descriptions may be used as required. 2. when this is not used, table one may be substituted and u.s. thread and two lockwashers will be supplied. unit will be rated at 250v (50/60hz only.) 3. vde approved at 250vac 4. vde approved at 415 vac -a -b -c -d -e -g -k -l -m -p -u -w -x -1 -2 standard hardware. no designation required. metric thread mounting inserts and terminals barrier 277v (50/60hz only) ( see note 3 ) 240/415v (50/60hz only) 277v/480v (50/60hz only) ( see note 4 ) handle guard, (available in zx, bx and snap-in versions only) 1/4 - 20 stud (m6 stud when -a option is selected) (<=70a requires -k, if >70a do not use -k) handle lock handle in opposite pole snap-in face plate adapter 120/240v 50/60hz wire clamp supplied (vde approved up to and including 16.0 amps) handle guard with no actuation feature (bx rocker only) silver 5/16" (.312") bullet gold 5/16" (.312") bullet optional the shaded areas denote vde and ccc (if applicable) approval options. this approval requires the addition of a v at the end of the part number. the v will be added to any part number formed entirely from shaded decisions. if non-shaded areas are selected, the unit will not be vde or ccc approved, but other approvals still apply. v = vde and ccc approved description note: ccc approval is pending. -0 -1 -1rec4 -1rec5 -1reg4 -1rs4 -1rls4 -1rs5 -3 -4 switch only (50, 70 or 100 amp switch) series series with auxiliary switch* .110 quick connect series with auxiliary switch* .187 quick connect series with auxiliary switch .110 quick connect series with alarm switch, electrical trip, .110 quick connect terminals series with alarm switch, electrical trip, .110 quick connect terminals (mid-trip only) series with alarm switch, electrical trip, .187 quick connect terminals shunt relay (not available in iel/ielx) this approval requires the addition of a c at the end of the part number. the unit will not be vde approved. c = ccc approved marking detail a (see table) load load line load load line line line fig. 2 fig. 3 fig. 4 fig. 5 fig. 1 fig. 6 of fo n on off of fo n on off o o o o line line rocker handle color indicating color indicating color rocker handle color indication on mounting/indicator code: a , b, c indication off mounting/indicator code: f, g, h on i on i o off off o indication off mounting/indicator code: m, n, p, r marking detail c (see ta ble) fig. 2 fig. 3 fig. 6 line load load line o off on o o on off marking detai l b (see table) fig. 2 fig. 3 fig. 4 fig. 5 fig. 1 fig. 6 off on on off off on on off o o o o line load load line load line load line line rocker handle color indicating color on i indication on mounting/indicator code: j, k, l off o line second decision single pole two pole three pole four pole* 1 11 111 1111 2 poles *not available in toggle seal handle type. consult factory for 5 and 6 pole iel part number. internal conguration third decision 3 * only one auxiliary switch is normally supplied on two or three pole units. switch is located in the right-hand pole (viewed from terminal end) unless otherwise specied. 1 2 3 4 iel 1 - 1rec4- 61- 20.0 - 01 - v 5 7 example: black yellow red blue green orange white -00 -10 -20 -30 -40 -60 -90 -01 (std) -11 -21 -31 -41 -61 -91 seventh decision 7 handle color and marking selection ial, iul, iel, ialh, iulh, ielh - toggle handle marked* on-off color unmarked i-o fifth decision 5 rated current use three numbers to print required current value between .100 amps minimum and 100 amps maximum. for example, use: .100 or 2.00 or 10.0 the vde (lth) will be 95% of the ul/csa rated current. fourth decision 4 frequency & delay switch only 400hz short delay 400hz long delay 400hz motor start 400hz 150% instant trip dc short delay dc long delay dc motor start dc 125% instant trip 50/60hz short delay 50/60hz long delay 50/60hz motor start 50/60hz 125% instant trip dc/60hz short delay dc/60hz long delay dc/60hz motor start dc/60 hz 135% instant trip for addition of inertial delay, add an f? to any delay numeral. sw -41 -42 -43 -49 -51 -52 -53 -59 -61 -62 -63 -69 - 71 - 72 -73 -79 notes: a. bezels of ialbx, iulbx, ielb, ielbx are black. b. consult factory for other marking options. note: ccc approval is pending. black red grey orange white -00 -20 -40 -50 -90 -01 -21 -41 -51 -91 -02 -22 -42 -52 -92 -03 -23 -43 -53 -93 -04 -24 -44 -54 -94 -05 -25 -45 -55 -95 -06 -26 -46 -56 -96 i-o fig.2 unmarked marking detail seventh decision 7 rocker handle color, indicator color and marking selection (see notes) ialx, iulx, ielx, ialzx, iulzx, ielzx rocker handle (single rocker color) rocker handle color indicating color marking color indicates: on-off fig.1 on-off i-o fig.3 on-off i-o fig.6 i-o fig.5 on-off fig.4 a vertical mounting horizontal mounting n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a black black black white red green white white white on on on -j0 -k0 -l0 -j1 -k1 -l1 -j2 -k2 -l2 -j3 -k3 -l3 -j4 -k4 -l4 -j5 -k5 -l5 -j6 -k6 -l6 b c w hite white black black black ialzx, iulzx, ielzx rocker handle (dual rocker color) black black black black black black white red green white red green white white white white white white on on on off off off -a0 -b0 -c0 -f0 -g0 -h0 -a1 -b1 -c1 -f1 -g1 -h1 -a2 -b2 -c2 -f2 -g2 -h2 -a3 -b3 -c3 -f3 -g3 -h3 -a4 -b4 -c4 -f4 -g4 -h4 -a5 -b5 -c5 -f5 -g5 -h5 -a6 -b6 -c6 -f6 -g6 -h6 black black black black white red green yellow white red green yellow off off off off -m0 -n0 -p0 -r0 n/a n/a n/a n/a -m2 -n2 -p2 -r2 -m3 -n3 -p3 -r3 n/a n/a n/a n/a -m6 -n6 -p6 -r6 n/a n/a n/a n/a a ialbx, iulbx, ielbx, lelbx rocker handle (dual rocker color) ialbx **iulbx *** i elbx **imlbx one handle per unit one handle per pole one handle per unit panel seal one handle per unit, rocker, bracket mounting one handle per unit, rocker, integral mounting o ne handle per unit ul 1500 o ne handle per pole ul 1500 one handle per unit mid trip indication one handle per pole mid trip indication one handle per unit, rocker, accidental-off protection one handle per unit, mid trip indication, rocker, accidental-off protection *ul recognized **ul recognized, csa certied ***ul recognized, csa certied, vde approved *** iml *** imlh select type and terminal first decision 1 ial **iul *** iel ialh **iulh *** ielh ialn *** iuln ialx **iulx *** ielx ialzx **iulzx *** ielzx * idl * id lh type terminal standard screw terminal, no designation required stud terminals clip terminals bullet terminals k c b sixth decision 6 notes: 1. one or more descriptions may be used as required. 2. when this is not used, table one may be substituted and u.s. thread and two lockwashers will be supplied. unit will be rated at 250v (50/60hz only.) 3. vde approved at 250vac 4. vde approved at 415 vac -a -b -c -d -e -g -k -l -m -p -u -w -x -1 -2 standard hardware. no designation required. metric thread mounting inserts and terminals barrier 277v (50/60hz only) ( see note 3 ) 240/415v (50/60hz only) 277v/480v (50/60hz only) ( see note 4 ) handle guard, (available in zx, bx and snap-in versions only) 1/4 - 20 stud (m6 stud when -a option is selected) (<=70a requires -k, if >70a do not use -k) handle lock handle in opposite pole snap-in face plate adapter 120/240v 50/60hz wire clamp supplied (vde approved up to and including 16.0 amps) handle guard with no actuation feature (bx rocker only) silver 5/16" (.312") bullet gold 5/16" (.312") bullet optional the shaded areas denote vde and ccc (if applicable) approval options. this approval requires the addition of a v at the end of the part number. the v will be added to any part number formed entirely from shaded decisions. if non-shaded areas are selected, the unit will not be vde or ccc approved, but other approvals still apply. v = vde and ccc approved description note: ccc approval is pending. -0 -1 -1rec4 -1rec5 -1reg4 -1rs4 -1rls4 -1rs5 -3 -4 switch only (50, 70 or 100 amp switch) series series with auxiliary switch* .110 quick connect series with auxiliary switch* .187 quick connect series with auxiliary switch .110 quick connect series with alarm switch, electrical trip, .110 quick connect terminals series with alarm switch, electrical trip, .110 quick connect terminals (mid-trip only) series with alarm switch, electrical trip, .187 quick connect terminals shunt relay (not available in iel/ielx) this approval requires the addition of a c at the end of the part number. the unit will not be vde approved. c = ccc approved ial series
second decision single pole two pole three pole 1 11 111 2 poles fifth decision 5 rated current use three numbers to print (.050 or 1.50 or 100) value between .050 amps and 100 amps. fourth decision 4 frequency and delay dc short delay dc long delay dc motor start dc 125% instant tri p 50/60hz short delay 50/60hz long delay 50/60hz motor start 50/60hz 125% instant trip for addition of inertial delay, add an ?f? to any delay numeral. *not available above 100 amps. -51 -52 -53* -59 -61 -62 -63 -69 the shaded areas denote vde and ccc (if applicable) approval options. this approval requires the addition of a v at the end of the part number. the v will be added to any part number formed entirely from shaded decisions. if non-shaded areas are selected, the unit will not be vde or ccc approved, but other approvals still apply. v = vde and ccc approved the approval requires the addition of a c at the end of the part number. the unit will not be vde approved. c = ccc approved 1 2 3 4 lel 1 - 1rec4 - 61 - 20.0 - 01 - v 5 7 example: third decision 3 * used only with mid-trip. -1 -1rec4 -1rec5 -1reg4 -1rs4 -1rls4 series series with auxiliary switch .110 quick connect series with auxiliary switch .187 quick connect series with auxiliary switch (gold contacts) .110 quick connect series with alarm switch, electrical trip, .110 quick connect series with alarm switch, electrical trip, .110 quick connect* internal conguration note: other options available, consult factory. one handle per unit one handle per pole one handle per unit, mid-trip indication one handle per pole, mid-trip indication one handle per unit, rocker, integral mounting one handle per unit, rocker, mid-trip indication, integral mounting one handle per unit, rocker, accidental-off protected one handle per unit, rocker, mid-trip indication, accidental-off protected lel lelh lml l mlh l elzx l mlzx l elbx l mlbx select type and terminal first decision 1 type terminal standard screw terminal, no designation required stud terminals clip terminals bullet terminals k c b description sixth decision metric thread mounting inserts and terminals b arrier 2 40v 50/60hz h andle guard, (available in zx, bx and snap-in versions only) 1/4 - 20 stud (m6 stud when -a option is selected) ( 50a requires -k, >50a do not use -k) h andle lock h andle in opposite pole s nap-in mounting plate adapter 1 20/240 vac, 5000 a.i.c., 70a max. 2 pole only with barrier (vde 250vac) 1 25vdc h andle guard with no actuate "of f" feature (see detail c) s ilver 5/16" (.312") bullet g old 5/16" (.312") bullet -a -b -f -g -k -l -m -p -u -v -x -1 -2 6 optional notes: 1. one or more descriptions may be used as required. 2. when this decision is not used, decision 7 may be substituted and u.s. thread will be supplied. 3 .if (m5 or m6) studs are required, use ?a? only on an lelk. seventh decision 7 lel toggle handle color selection black w/ white markings yellow w/ black markings red w/ white markings blue w/ white markings green w/ white markings orange w/ black markings white w/ black markings -01 -11 -21 -31 -41 -61 -91 see alternate 7th decision for zx and bx rocker handles. lel decision tables http://airpax.sensata.com/ ial/cel/lel series - operating characteristics 149 lel series - decision tables http://airpax.sensata.com 153 notes: the lel family of circuit breakers are designed to meet 8mm creepage and clearance requirements for installation category 111, pollution degree 3, case a as measured in iec 664. intended for use in equipment designed to comply with iec 380, 435, 601 and vde 0730, 0804 & 0805.
line line fig. 2 fig. 3 fig. 4 fig. 5 fig. 1 fig. 6 rocker handle color indicating color indicating color rocker handle color indication ?on? mounting/indicator code: a, b, c load load line load load line indication ?off? mounting/indicator code: f, g, h line line area reserved for amperage marking. on i on i o off off o off on on off o off on o o o on off marking detail ?a? (see table) fig. 2 fig. 3 fig. 4 fig. 5 fig. 1 fig. 6 off off o o line load line load line load line marking detail ?b? (see table) off on on offon on o o load line rocker handle color indicating color on i indication ?on? mounting/indicator code: j, k, l off o notes: a. bezels of ialbx, iulbx, ielb, ielbx are black. b. consult factory for other marking options. black red grey orange white -00 -20 -40 -50 -90 -01 -21 -41 -51 -91 -02 -22 -42 -52 -92 -03 -23 -43 -53 -93 -04 -24 -44 -54 -94 -05 -25 -45 -55 -95 -06 -26 -46 -56 -96 i-o fig.2 unmarked marking detail seventh decision 7 rocker handle color, indicator color and marking selection (see notes) lelzx & lmlzx rocker handle (single rocker color) rocker handle color indicating color marking color indicates: on-off fig.1 on-off i-o fig.3 on-off i-o fig.6 i-o fig.5 on-off fig.4 a vertical mounting horizontal mounting n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a black black black white red green white white white on on on -j0 -k0 -l0 -j1 -k1 -l1 -j2 -k2 -l2 -j3 -k3 -l3 -j4 -k4 -l4 -j5 -k5 -l5 -j6 -k6 -l6 b c white white black black black lelzx & lmlzx rocker handle (dual rocker color) black black black black black black white red green white red green white white white white white white on on on off off off -a0 -b0 -c0 -f0 -g0 -h0 -a1 -b1 -c1 -f1 -g1 -h1 -a2 -b2 -c2 -f2 -g2 -h2 -a3 -b3 -c3 -f3 -g3 -h3 -a4 -b4 -c4 -f4 -g4 -h4 -a5 -b5 -c5 -f5 -g5 -h5 -a6 -b6 -c6 -f6 -g6 -h6 black black black black white red green yellow white red green yellow off off off off -m0 -n0 -p0 -r0 n/a n/a n/a n/a -m2 -n2 -p2 -r2 -m3 -n3 -p3 -r3 n/a n/a n/a n/a -m6 -n6 -p6 -r6 -m5 -n5 -p5 -r5 a lelbx rocker handle (dual rocker color) indication ?off? mounting/indicator code: m, n, p, r no actuation access optional handle position ?off? with guard handle position ?on? with guard marking detail ?c? (see table) fig. 2 fig. 3 fig. 6 line load load line o off on o o on off marking detail a (see table) load load line load load line line line fig. 2 fig. 3 fig. 4 fig. 5 fig. 1 fig. 6 of fo n on off of fo n on off o o o o line line rocker handle color indicating color indicating color rocker handle color indication on mounting/indicator code: a , b, c indication off mounting/indicator code: f, g, h on i on i o off off o indication off mounting/indicator code: m, n, p, r marking detail c (see ta ble) fig. 2 fig. 3 fig. 6 line load load line o off on o o on off marking detai l b (see table) fig. 2 fig. 3 fig. 4 fig. 5 fig. 1 fig. 6 off on on off off on on off o o o o line load load line load line load line line rocker handle color indicating color on i indication on mounting/indicator code: j, k, l off o line http://airpax.sensata.com/ ial/cel/lel series - operating characteristics 150 lel series - decision tables ial series 154
second decision single pole two pole three pole 1 11 111 2 poles fifth decision 5 rated current use three numbers in build (.050 or 1.50 or 100). required value between .050 amps minimum and 125 amps maximum. fourth decision 4 frequency and delay dc short delay dc long delay dc motor start dc 125% instant tri p for addition of inertial delay, add an ?f? to any delay numeral. example: -51f *not available above 100 amps. -51 -52 -53* -59 the shaded areas denote vde and ccc (if applicable) approval options. this approval requires the addition of a v at the end of the part number. the v will be added to any part number formed entirely from shaded decisions. if non-shaded areas are selected, the unit will not be vde or ccc approved, but other approvals still apply. v = vde and ccc approved the approval requires the addition of a c at the end of the part number. the unit will not be vde approved. c = ccc approved 1 2 3 4 cel 1 - 1rec4 - 51 - 20.0 - a - 01 - v 5 7 6 example: third decision 3 * only one auxiliary switch is normally supplied on two and three pole units switch is located in the right hand pole (viewed from terminal end). note, aux switch followed by ?r? indicates reverse mount option ** not available for 125 amp single pole internal conguration select type and terminal first decision 1 type terminal standard screw terminal, no designation required stud terminals clip terminals bullet terminals k c b description sixth decision 6 optional notes: 1. one or more descriptions may be used as required. 2. when this decision is not used, decision 7 may be substituted and u.s. thread will be supplied. seventh decision 7 lel toggle handle color selection black w/ white markings yellow w/ black markings red w/ white markings blue w/ white markings green w/ white markings orange w/ black markings white w/ black markings -01 -11 -21 -31 -41 -61 -91 see alternate 7th decision for zx and bx rocker handles. cel one handle per unit, ul489a listed celzx one handle per unit, rocker handle, ul489a listed celbx one handle per unit, at rocker handle, ul489a listed celh one handle per pole, ul489a listed cml single pole only, one handle per unit mid-trip construction, ul489a listed -1rec4 series with auxiliary switch .110 quick connect -1rls4 ** series with auxiliary switch .110 quick connect, mid-trip only -1rec5 series with auxiliary switch .187 quick connect -1rs4 ** alarm switch, .110 quick connect -1 series cmlzx single pole only, one handle per unit, rocker handle w/ rls aux switch, mid-trip construction, ul489a listed cmlbx single pole only, one handle per unit, at rocker handle w/ rls aux switch, mid-trip construction, ul489a listed cmlh one handle per pole mid-trip construction, ul489a listed the approval requires the addition of a t at the end of the part number. the unit will only be t v en60947-2 approved with a single pole, 125 amp rating conguration. t = t v approved -a metric thread mounting inserts and terminals -g snap-in mounting plate adapter with handle guard (zx, bx and snap-in only) -t 80vdc, 10000aic, (required over 50a) -v 125vdc -1 silver 5/16? (.312?) bullet -2 gold 5/16? (.312?) bullet -k 1/4-20 stud (m6 stud when metric option -a selected) 50a requires -k, >50a do not use -k -b barrier -p snap-in mounting plate adapter cel decision tables http://airpax.sensata.com/ ial/cel/lel series - operating characteristics 149 cel series - decision tables http://airpax.sensata.com 155
line line fig. 2 fig. 3 fig. 4 fig. 5 fig. 1 fig. 6 rocker handle color indicating color indicating color rocker handle color indication ?on? mounting/indicator code: a, b, c load load line load load line indication ?off? mounting/indicator code: f, g, h line line area reserved for amperage marking. on i on i o off off o off on on off o off on o o o on off marking detail ?a? (see table) fig. 2 fig. 3 fig. 4 fig. 5 fig. 1 fig. 6 off off o o line load line load line load line marking detail ?b? (see table) off on on offon on o o load line rocker handle color indicating color on i indication ?on? mounting/indicator code: j, k, l off o notes: a. bezels of ialbx, iulbx, ielb, ielbx are black. b. consult factory for other marking options. black red grey orange white -00 -20 -40 -50 -90 -01 -21 -41 -51 -91 -02 -22 -42 -52 -92 -03 -23 -43 -53 -93 -04 -24 -44 -54 -94 -05 -25 -45 -55 -95 -06 -26 -46 -56 -96 i-o fig.2 unmarked marking detail seventh decision 7 rocker handle color, indicator color and marking selection (see notes) lelzx & lmlzx rocker handle (single rocker color) rocker handle color indicating color marking color indicates: on-off fig.1 on-off i-o fig.3 on-off i-o fig.6 i-o fig.5 on-off fig.4 a vertical mounting horizontal mounting n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a black black black white red green white white white on on on -j0 -k0 -l0 -j1 -k1 -l1 -j2 -k2 -l2 -j3 -k3 -l3 -j4 -k4 -l4 -j5 -k5 -l5 -j6 -k6 -l6 b c white white black black black lelzx & lmlzx rocker handle (dual rocker color) black black black black black black white red green white red green white white white white white white on on on off off off -a0 -b0 -c0 -f0 -g0 -h0 -a1 -b1 -c1 -f1 -g1 -h1 -a2 -b2 -c2 -f2 -g2 -h2 -a3 -b3 -c3 -f3 -g3 -h3 -a4 -b4 -c4 -f4 -g4 -h4 -a5 -b5 -c5 -f5 -g5 -h5 -a6 -b6 -c6 -f6 -g6 -h6 black black black black white red green yellow white red green yellow off off off off -m0 -n0 -p0 -r0 n/a n/a n/a n/a -m2 -n2 -p2 -r2 -m3 -n3 -p3 -r3 n/a n/a n/a n/a -m6 -n6 -p6 -r6 -m5 -n5 -p5 -r5 a lelbx rocker handle (dual rocker color) indication ?off? mounting/indicator code: m, n, p, r no actuation access optional handle position ?off? with guard handle position ?on? with guard marking detail ?c? (see table) fig. 2 fig. 3 fig. 6 line load load line o off on o o on off marking detail a (see table) load load line load load line line line fig. 2 fig. 3 fig. 4 fig. 5 fig. 1 fig. 6 of fo n on off of fo n on off o o o o line line rocker handle color indicating color indicating color rocker handle color indication on mounting/indicator code: a , b, c indication off mounting/indicator code: f, g, h on i on i o off off o indication off mounting/indicator code: m, n, p, r marking detail c (see ta ble) fig. 2 fig. 3 fig. 6 line load load line o off on o o on off marking detai l b (see table) fig. 2 fig. 3 fig. 4 fig. 5 fig. 1 fig. 6 off on on off off on on off o o o o line load load line load line load line line rocker handle color indicating color on i indication on mounting/indicator code: j, k, l off o line http://airpax.sensata.com/ ial/cel/lel series - operating characteristics 150 cel series - decision tables ial series 156
lelhp decision tables lelpk one handle per unit lmlpk one handle per unit, mid-trip lelhpk one handle per pole lmlhpk one handle per pole, mid-trip lelzxpk one zx rocker handle per unit (integral mounting) lmlzxpk one zx rocker handle per unit, mid-trip (integral mounting) lelbxpk one bx rocker handle per unit (integral mounting) lmlbxpk one bx rocker handle per unit, mid-trip (integral mounting) lelhpk 11 - 1rec4 - 51 - 125. - a - 01 - v select type with stud terminals first decision poles second decision 11 two pole (up to 150 amps) 111 three pole (160 to 200 amps) internal conguration third decision frequency and delay fourth decision rated current (amps) fifth decision -51 dc 125% short delay (125 to 150 amp) 125. 130. 135. 150. 175. 200. dc 135% short delay (160 to 200 amp) -52 dc 125% long delay (125 to 150 amp) dc 135% long delay (160 to 200 amp) -59 dc 125% instant trip (125 to 150 amp) dc 135% instant trip (160 to 200 amp) 7 toggle handle color seventh decision additional ratings available. see lel alternative 7th decision for zx & bx rocker handles 1. one toggle handle per unit on 125a to 150a units (2-parallel pole) 2. 175a to 200a (3-parallel pole) requires handle in each pole, ?h? selection -1 series -1rec4 series with auxiliary switch .110 quick connect -1reg4 series, aux switch (gold contacts) .110 quick connect -1rlsg4 series, alarm aux switch (gold contacts), .110 quick connect, mid-trip only -1rls4 series with alarm aux switch .110 quick connect, mid-trip only -1rs4 series with alarm aux switch .110 quick connect -1rs4 series with alarm aux switch .187 quick connect -1rs5 series with alarm aux switch .187 quick connect, mid-trip -1rec5 series with aux switch .187 quick connect -1rls5 series with alarm aux switch .187 quick connect, mid-trip only example: 1 2 3 4 5 6 7 sixth decision 6 optional (leave entry blank if none apply) notes: 1. one or more descriptions may be used as required. 2. when this decision is not used, decision 7 may be substituted and u.s. thread will be supplied. -a metric thread mounting inserts and terminals -g snap-in mounting plate adapter with handle guard (zx, bx & snap-in only) -x handle guard with no actuate off feature (bx only, no mid-trip) -p snap-in mounting plate adapter -31 blue w/ white markings -41 green w/ white markings -61 orange w/ black markings -01 black w/ white markings -11 yellow w/ black markings -21 red w/ white markings -91 white w/ black markings the shaded areas denote vde approval options. this approval requires the addition of a v at the end of the part number. the v will be added to any part number formed entirely from shaded decisions. if non-shaded areas are selected, the unit will not be vde approved, but other approvals still apply. v = vde approved for addition of intertial delay, add an ?f? to any delay option. example: - 59 becomes -59f http://airpax.sensata.com/ ial/cel/lel series - operating characteristics 149 lelhp series - decision tables http://airpax.sensata.com 157
celhpk 11 - 1rec4 - 51 - 125. - a - 01 - v select type first decision celp one toggle handle per unit poles second decision 11 two pole (up to 150 amps) 111 three pole (160 to 250 amps) 1111 four pole (400 amps) internal conguration third decision frequency and delay fourth decision rated current (amps) fifth decision -51 dc 125% short delay (101 to 150 amp) 125. 130. 135. 150. 175. 200. 400. dc 135% short delay (160 to 250 amp) -52 dc 125% long delay (101 to 150 amp) dc 135% long delay (160 to 250 amp) -53 dc 125% motor start (101 to 150 amp) dc 135% motor start (160 to 250 amp) -59 dc 125% instant trip (101 to 150 amp) dc 135% instant trip (160 to 250 amp) 7 toggle handle color seventh decision additional ratings available. see lel alternative 7th decision for zx & bx rocker handles celhp one toggle handle per pole cmlhp one toggle handle per pole, mid-trip construction celzxp one rocker handle per unit celbxp one at rocker handle per unit 1. one toggle handle per unit is available only on 101a to 200a (two parallel pole construction) 2. 201a to 250a (three parallel pole constructions) require handles in each pole, ?h? version rst decision 3. unit supplied with bullet terminals will not have buss bar installed, unless requested, buss bar supplied standard to 150a only. 4. one handle per unit is available for 100a to 200a (two parallel pole constructions) and 201a to 250a (three pole constructions) (zx & bx versions only) 5. 400 amps available with toggle handes only -0 switch only -1 series -1rec4 series with auxiliary switch .110 quick connect -1rls4 * series with alarm aux. switch .110 quick connect, mid-trip only -1rs4 * series with alarm aux. switch .110 quick connect -1rs4 * series with alarm aux. switch .187 quick connect -1rec5 series with auxiliary switch .187 quick connect -1rls5 * series with alarm aux. switch .187 quick connect, mid-trip only 1. only one auxiliary switch is normally supplied on two and three pole units. switch is located in the right hand pole (viewed from terminal end panel mount position). 2. when more than one aux. switch is required, change the 1 (of the 1rec4) to 2 or 3. if switches are mixed, then use ?2r? or 3r?. * not available at 400 amps example: terminal standard screw terminal, no designation required stud terminals clip terminals bullet terminals k c b 1 2 3 4 5 6 7 sixth decision 6 optional (leave entry blank if none apply) notes: 1. one or more descriptions may be used as required. 2. when this decision is not used, decision 7 may be substituted and u.s. thread will be supplied. -a metric thread mounting inserts and terminals -g snap-in mounting plate adapter with handle guard (zx, bx & snap-in only) -1 silver 5/16? (.312?) bullet -2 gold 5/16? (.312?) bullet -x handle guard with no actuate off feature (bx only, no mid-trip) -b barrier -01 black w/ white markings -11 yellow w/ black markings -21 red w/ white markings -31 blue w/ white markings -41 green w/ white markings -61 orange w/ black markings -91 white w/ black markings the shaded areas denote vde approval options. this approval requires the addition of a v at the end of the part number. the v will be added to any part number formed entirely from shaded decisions. if non-shaded areas are selected, the unit will not be vde approved, but other approvals still apply. v = vde approved celhp decision tables http://airpax.sensata.com/ ial/cel/lel series - operating characteristics 150 lelhp series - decision tables ial series 158
?2013 sensata technologies, inc. all rights reserved worldwide. the following data sheet is an excerpt from our airpax? power protection catalog, literature # 2455005000, printed in the usa, may 9th, 2013. important notice: sensata technologies reserves the right to make changes to, or to discontinue, any product or service identifed in this publication without notice. before placing orders, users should obtain the latest version of the relevant information to verify t hat the information being relied upon is current. sensata technologies assumes no responsibility for customers product designs or applications. users must determine the suitability of the sensata device described in this publication for their application, including the level of reliability required. many factors be yond sensatas control can affect the use and performance of a sensata product in a particular application, including the conditions under which the product is used and the time and environmental conditions in which the product is expected to perform. as these facto rs are uniquely within the users knowledge and control, it is essential that the user evaluate the sensata product to determine whether it is f t for a particular purpose and suitable for the users application. sensata technologies products are sold subject to sensatas terms and conditions of sale which can be found at: www.sensata.com/terms.htm http://airpax.sensata.com/ sensata technologies inc. 529 pleasant street attleboro, ma 02703, usa phone: +1 508-236-3287


▲Up To Search▲   

 