  emc/emi products > fn 280 compact filtered power entry module typical applications the fn 280 power entry module combines an iec inlet, a mains filter with single or dual- fuse holder and a 2-pole rocker switch in a small form factor. choosing fn 280 product line brings you the rapid availability of a standard filter associated with the necessary safety acceptances. standard iec connector filters are a practical solution helping you to pass emi system approval in a short time. a wide selection on amperage ratings, fuse options, mounting possibilities and filters for medical applications are designed to offer you the desired solution. n high conducted attenuation performance, based on chokes with high saturation resistance and excellent thermal behavior. n rear/front or snap-in mounting. n single or dual-fuse holder. n 2-pole rocker switch. n custom-specific versions are available on request. n portable electrical and electronic equipment n consumer goods n edp and office equipment n single-phase power supplies, switch-mode power supplies n test and measurement equipment n medical equipment features and benefits technical specifications maximum continuous operating voltage: 250vac, 50/60hz operating frequency: 50 to 400hz rated currents: 1 to 10a @ 40c max. high potential test voltage: p C> pe 2000vac for 2 sec (standard types) p C> pe 2500vac for 2 sec (b types) p C> n 760vac for 2 sec protection category: ip40 according to iec 60529 temperature range (operation and storage): -25c to +85c (25/85/21) design corresponding to: ul 1283, csa 22.2 no. 8 1986, iec/en 60939 flammability corresponding to: ul 94v-2 or better mtbf @ 40c/230v (mil-hb-217f): 1,500,000 hours fuse holder: 1 or 2 fuses (?5 x 20mm) marking: max. 250v ~ (text is print. below fuse symbol) rocker switch description: function: 2-pole, dark not illuminated marking i - 0 electrical specifications: inrush current 82a 6,000 on-off operations according to ul 1054, tv 5 10,000 on-off operations according to enec mechanical life: 50,000 cycles switch ratings: usa (ul) and canada (c-ul): 10a, 125vac; 10a, 250vac; 1/3hp europe (enec): 10a (4a), 250vac* * value in () relates to the inductive current charge: cos g = 0.65 typical electrical schematic n pe p line cx r 2xl1 2xcy load n pe p e types standard types n pe p line cx r 2xl1 2xcy load l2 n pe p iec inlet filters fn 280 approvals n rated currents up to 10a n single or dual-fuse holder n fuses ?5 x 20mm n 2-pole rocker switch n general purpose application n optional earth line choke (e type) n optional medical version (b type)
2 emc/emi products > fn 280 * maximum leakage under normal operating conditions. note: if the neutral line is interrupted, worst case leakage could reach twice this level. ** filters are delivered without fuse. filter selection table fn 281-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 1 90 fn 281-2-06 2 (2.4) 373 2 220 2.2 1000 -06 1 90 fn 281-4-06 4 (4.8) 373 1 220 2.2 1000 -06 1 90 fn 281-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 1 90 fn 281-10-06 10 (11.6) 373 0.34 220 2.2 1000 -06 1 90 fn 282-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 2 90 fn 282-2-06 2 (2.4) 373 2 220 2.2 1000 -06 2 90 fn 282-4-06 4 (4.8) 373 1 220 2.2 1000 -06 2 90 fn 282-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 2 90 fn 282-10-06 10 (11.6) 373 0.34 220 2.2 1000 -06 2 90 fn 283-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 1 90 fn 283-2-06 2 (2.4) 373 2 220 2.2 1000 -06 1 90 fn 283-4-06 4 (4.8) 373 1 220 2.2 1000 -06 1 90 fn 283-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 1 90 fn 283-10-06 10 (11.6) 373 0.34 220 2.2 1000 -06 1 90 fn 284-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 2 90 fn 284-2-06 2 (2.4) 373 2 220 2.2 1000 -06 2 90 fn 284-4-06 4 (4.8) 373 1 220 2.2 1000 -06 2 90 fn 284-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 2 90 fn 284-10-06 10 (11.6) 373 0.34 220 2.2 1000 -06 2 90 fn 285-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 1 90 fn 285-2-06 2 (2.4) 373 2 220 2.2 1000 -06 1 90 fn 285-4-06 4 (4.8) 373 1 220 2.2 1000 -06 1 90 fn 285-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 1 90 fn 285-10-06 10 (11.6) 373 0.34 220 2.2 1000 -06 1 90 fn 286-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 2 90 fn 286-2-06 2 (2.4) 373 2 220 2.2 1000 -06 2 90 fn 286-4-06 4 (4.8) 373 1 220 2.2 1000 -06 2 90 fn 286-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 2 90 fn 286-10-06 10 (11.6) 373 0.34 220 2.2 1000 -06 2 90 fn 283e-1-06 1 (1.2) 373 7.5 0.4 220 2.2 1000 -06 1 100 fn 283e-2-06 2 (2.4) 373 2 0.4 220 2.2 1000 -06 1 100 fn 283e-4-06 4 (4.8) 373 1 0.4 220 2.2 1000 -06 1 100 fn 283e-6-06 6 (7.2) 373 0.45 0.4 220 2.2 1000 -06 1 100 fn 284e-1-06 1 (1.2) 373 7.5 0.4 220 2.2 1000 -06 2 100 fn 284e-2-06 2 (2.4) 373 2 0.4 220 2.2 1000 -06 2 100 fn 284e-4-06 4 (4.8) 373 1 0.4 220 2.2 1000 -06 2 100 fn 284e-6-06 6 (7.2) 373 0.45 0.4 220 2.2 1000 -06 2 100 fn 282b-1-06 1 (1.2) 2 7.5 220 1000 -06 2 90 fn 282b-2-06 2 (2.4) 2 2 220 1000 -06 2 90 fn 282b-4-06 4 (4.8) 2 1 220 1000 -06 2 90 fn 282b-6-06 6 (7.2) 2 0.45 220 1000 -06 2 90 fn 282b-10-06 10 (11.6) 2 0.34 220 1000 -06 2 90 fn 284b-1-06 1 (1.2) 2 7.5 220 1000 -06 2 90 fn 284b-2-06 2 (2.4) 2 2 220 1000 -06 2 90 fn 284b-4-06 4 (4.8) 2 1 220 1000 -06 2 90 fn 284b-6-06 6 (7.2) 2 0.45 220 1000 -06 2 90 fn 284b-10-06 10 (11.6) 2 0.34 220 1000 -06 2 90 fn 286b-1-06 1 (1.2) 2 7.5 220 1000 -06 2 90 fn 286b-2-06 2 (2.4) 2 2 220 1000 -06 2 90 fn 286b-4-06 4 (4.8) 2 1 220 1000 -06 2 90 fn 286b-6-06 6 (7.2) 2 0.45 220 1000 -06 2 90 fn 286b-10-06 10 (11.6) 2 0.34 220 1000 -06 2 90 filter rated current leakage current* inductance capacitance resistance output fuses** weight @ 40c (25c) @ 230vac/50hz l1 l2 cx cy r connections [a] [a] [mh] [mh] [nf] [nf] [k?] [qty] [g]
3 emc/emi products > fn 280 per cispr 17; a = 50/50 sym; b = 50/50 asym; c = 0.1/100 sym; d = 100/0.1 sym typical filter attenuation 1a types 2 to 6a types 10a types product selector fn 28xx-yy-zz 06: faston 6.3 x 0.8mm (spade/soldering) 1 to 10: rated current blank: standard version e: optional earth line choke b: medical version (with bleed resistor and without y2-capacitor) 1: flange mounting version top/bottom, single-fuse 2: flange mounting version top/bottom, dual-fuse 3: flange mounting version left/right, single-fuse 4: flange mounting version left/right, dual-fuse 5: snap-in version, single-fuse 6: snap-in version, dual-fuse for example: fn 281-6-06, fn 283b-04-06, fn 283e-1-06
4 emc/emi products > fn 280 fn 281 fn 282 fn 283 fn 284 fn 285 fn 286 tolerances dimensions a 32 32 50 50 32 32 0.3 b 82 82 65 65 65 65 0.3 c 72 72 40 40 0.1 d 43.1 43.1 43.1 43.1 43.6 43.6 0.3 e 28.5 28.5 28.5 28.5 28.5 28.5 0.25 f 5.5 5.5 5.5 5.5 5 5 0.3 g 59.95 max. 59.95 max. 59.95 max. 59.95 max. 59.95 max. 59.95 max. h ?3.5 ?3.5 ?3.3 ?3.3 i 13.4 16.2 13.4 16.2 13.9 16.7 0.3 j 22.5 22.5 22.5 22.5 22.5 22.5 m r 2.5 r 2.5 r 2.5 r 2.5 r 2.5 r 2.5 n 60 60 60 60 61.5 +0.2/-0* 61.5 +0.2/-0* +0.5/-0 p 29 29 29 29 29 29 +0.5/-0 r m3 m3 m3 m3 s 90 90 90 90 * for a panel thickness between 0.8 and 3mm all dimensions in mm; 1 inch = 25.4mm tolerances according: iso 2768-m / en 22768-m mechanical data fn 281 / fn 282 fn 283 / fn 284 a b e h c s f d i 6.3 x 0.8 j u fn 285 / fn 286 panel cut out n m p c a b e h g s f d i 6.3 x 0.8 j u c a b e g s f d i 6.3 x 0.8 j u r n m p c r g iec plug type iec plug type c14 c14 c14
04/2013 en headquarters, global innovation and development center scha?ner group nordstrasse 11 4542 luterbach schweiz t +41 32 681 66 26 f +41 32 681 66 30 info@scha?ner.com www.scha?ner.com sales and application centers china scha?ner emc ltd. shanghai t20-3, no 565 chuangye road pudong new area shanghai 201201 t +86 21 3813 9500 f +86 21 3813 9501 / 02 cschina@scha?ner.com www.scha?ner.com finland scha?ner oy sauvonrinne 19 h 08500 lohja t +358 19 35 72 71 f +358 19 32 66 10 ?nlandsales@scha?ner.com france scha?ner emc s.a.s. 112, quai de bezons 95103 argenteuil t +33 1 34 34 30 60 f +33 1 39 47 02 28 francesales@scha?ner.com germany scha?ner deutschland gmbh schoemperlenstrasse 12b 76185 karlsruhe t +49 721 56910 f +49 721 569110 germanysales@scha?ner.com italy scha?ner emc s.r.l. via galileo galilei, 47 20092 cinisello balsamo (mi) t +39 02 66 04 30 45/47 f +39 02 61 23 943 italysales@scha?ner.com japan scha?ner emc k.k. mitsui-seimei sangenjaya bldg. 7f 1-32-12, kamiuma, setagaya-ku tokyo 154-0011 t +81 3 5712 3650 f +81 3 5712 3651 japansales@scha?ner.com www.scha?ner.jp singapore scha?ner emc pte ltd. blk 3015a ubi road 1 05-09 kampong ubi industrial estate t +65 6377 3283 f +65 6377 3281 singaporesales@scha?ner.com spain scha?ner emc espa?a calle calndula 93 miniparc iii, edi?cio e el soto de la moraleja alcobendas 28109 madrid t +34 618 176 133 spainsales@scha?ner.com sweden scha?ner emc ab turebergstorg 1, 6 19147 sollentuna t +46 8 5792 1121 / 22 f +46 8 92 96 90 swedensales@scha?ner.com switzerland scha?ner emv ag nordstrasse 11 4542 luterbach t +41 32 681 66 26 f +41 32 681 66 41 sales@scha?ner.ch taiwan scha?ner emv ltd. 6th floor, no 413 rui guang road neihu district taipei city 114 t +886 2 87525050 f +886 2 87518086 taiwansales@scha?ner.com thailand scha?ner emc co. ltd. northern region industrial estate 67 moo 4 tambon ban klang amphur muang p.o. box 14 lamphun 51000 t +66 53 58 11 04 f +66 53 58 10 19 thailandsales@scha?ner.com uk scha?ner ltd. 5 ashville way molly millars lane wokingham berkshire rg41 2pl t +44 118 9770070 f +44 118 9792969 uksales@scha?ner.com www.scha?ner.uk.com usa scha?ner emc inc. 52 may?eld avenue edison, new jersey 08837 t +1 732 225 9533 f +1 732 225 4789 usasales@scha?ner.com www.scha?ner.com/us to ?nd your local partner within scha?ner?s global network, please go to www.scha?ner.com ? 2013 scha?ner group speci?cations are subject to change within notice. the latest version of the data sheets can be obtained from the website. all trademarks recognized. scha?ner is an iso-registered company. its products are designed and manufactured under the strict quality and environmental requirements of the iso 9001 and iso 14001 standards. this document has been carefully checked. however, scha?ner does not assume any liability for errors or inaccuracies.


▲Up To Search▲   

 
Price & Availability of FN282-4-06

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X