Part Number Hot Search : 
OLSYG116 MS15N60 WF202 NSVS1103 20MB4 28100 C2220C N74LS1
Product Description
Full Text Search
 

To Download 3CFE1 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  c series c 92 switch with iec connector compact size ul recognized csa certified vde approved c series two function power entry module combining a dpst switch and an iec 320 power line connector. compact packaging allows a smaller panel cutout with choice of snap-in or flange mounting. available with general purpose filtering (f models - cfs, cfe), medical application filtering (h models - chs, che) or unfiltered (cs, ce). terminals allow for easy connection to any wiring scheme. preconnected terminals from line to switch are available (b models - cbs, cbe) for reducing oem wiring time. the medical versions (h models) are designed specifically for health care applications. their extremely low leakage current allows compliance with ul544 and ul2601 as well as csa22.2 health care specifications for use with both patient and non-patient care equipment. the c series also has the adaptability to fit into existing panel cutouts using snap-on extender options. using the ca430 extender, the panel cutout height is increased by 0.13?. (extender is available pre-assembled using part numbers with ?k? designation) specifications hipot rating (one minute): line-to-ground 2250 vdc line-to-line 1450 vdc operating frequency: 50/60 hz rated voltage: 120/250 vac rated current: 10a@120 vac 10a @ 250 vac operating voltages: 115/230 vac switch: rated for 10,000 operations at full load. 51 amp inrush capability. terminals: unfiltered .187? x .032? terminals filtered .25? x .032? terminals filtered models only: maximum leakage current, each line-to-ground f models @ 120 vac 60 hz: .25ma @ 250 vac 50 hz: .40ma h models @ 120 vac 60 hz: 2 a @ 250 vac 50 hz: 5 a minimum insertion loss in db: line-to-ground in 50 ohm circuit current frequency mhz rating 0.05 0.15 0.5 1 5 10 30 h models 1a 16 21 37 44 26 21 10 3a 9 14 31 32 26 24 14 6a 4 10 22 23 19 18 13 10a 2 6 10 15 11 11 9 f models 1a 10 26 46 48 46 47 46 3a 8 16 32 36 43 48 50 6a 4 11 22 27 36 41 50 10a 1 4 14 18 27 33 42 line-to-line in 50 ohm circuit current frequency mhz rating 0.05 0.15 0.5 1 5 10 30 h models 1a 1 6 13 29 38 42 26 3a 1 5 10 22 36 34 36 6a 1 5 14 20 31 33 37 10a 1 4 11 19 32 37 38 f models 1a 1 3 13 28 62 67 42 3a 2 6 14 23 65 65 67 6a 2 6 14 27 46 48 58 10a 1 7 14 23 42 44 62 electrical schematic f models (cfs, cfe) h models (chs, che) resistor location for reference only. cfs cs note 1: jumpers provided on cbs and cbe versions. note 2: location of optional filter. b models (cbs, cbe) note 1 note 1 note 2 note 2 power on/off www.cor.com - libertyville, il (847) 680-7400
libertyville, il (847) 680-7400 - www.cor.com series c c 93 case styles metric shown in italics. ce, cbe ? cfs, chs cs, cbs ? mounting holes: dia. (2) with .23 dia. x 90 counter sunk .13 3.3 case dimensions metric shown in italics. part a b c d e f no. (max) (max) (max) .006 .006 .006 .152 .152 .152 cs, cbs ce, cbe cfs, chs cfe, che 1.23 31.24 .97 24.64 1.62 41.17 1.06 26.92 1.540* 39.12* 1.417 36.0 .97 24.64 1.62 41.17 1.06 26.92 1.540* 39.12* 1.74 44.2 panel cutout for thickness of .031-.098 ( .8-2.5 ). not recommended for plastic panels. for snap-in applications, the d sides of the cutout must have a .02(. 508 ) radius on the installation side. snap-in models allow front mounting only. 1.23 31.24 1.74 44.2 1.12 28.5 1.12 28.5 1.417 36.0 1.62 41.17 1.62 41.17 * with k extender (ca430) add to height .13 3.3 1.540* 39.12* 1.540* 39.12* 2.53 64.26 2.53 64.26 cfe, che ? cbs, cbe pre-wired terminals available part numbers 10cs1 10ce1 1chs1 1che1 10cks1 10cke1 1ckhs1 1ckhe1 1cfs1 1cfe1 3chs1 3che1 1ckfs1 1ckfe1 3ckhs1 3ckhe1 3cfs1 3CFE1 6chs1 6che1 3ckfs1 3ckfe1 6ckhs1 6ckhe1 6cfs1 6cfe1 10chs1 10che1 6ckfs1 6ckfe1 10ckhs1 10ckhe1 10cfs1 10cfe1 10ckfs1 10ckfe1 10cbs1 10cbe1 10ckbs1 10ckbe1 panel cutout 10 ckfs1 current rating (1, 3, 6, 10a) series extender option blank - without extender k - pre-assembled with ca430 extender terminal type (1/4? quick connect) filter type blank - unfiltered b - pre-wired switch f - standard filter h - medical grade filter mounting type s - snap-in e - flange mount ordering information consult your local corcom sales representative for pricing. mounting holes: dia. (2) with .23 dia. x 90 counter sunk .13 3.3


▲Up To Search▲   

 
Price & Availability of 3CFE1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X