rev a product ep13 th adsl line transformer meets requirements of iec60950 for supplementary insulation, 250v working voltage information subject to change without notice. 10/02 primary units are in inches. millimeters are in brackets. electrical specifications at +20c unless noted otherwise test description limit units tol notes inductance 440 h 5% 1-4 tie( 2+3 ), 10khz, 100mvac, ls. leakage inductance 10.0 h max. 1-4 tie( 2+3, 7+8+9+10 ), 300khz, 100mvac, ls. dc resistance 0.590 ? max. 1-3 dc resistance 0.590 ? max. 2-4 dc resistance 0.480 ? max. 10-8 dc resistance 0.480 ? max. 9-7 turns ratio 1 : 1 --- 1% ( 1-3 ) : ( 2-4 ), 10khz, 100mvac. dielectric 1,875 vac 500a 1-10 tie( 2+3, 8+9 ), 1 second test, 500a maximum leakage current. designed to reflect 100 ohms on the line with 100 ohms on the ic side. operating temperature range: -40c to +85c C2220 description tel 888-978-2638 - fax 605-886-8995 - specifications subject to change without notice. for latest revision visit www.tycopowercomponents.com the information contained in this drawing is the sole property of coev, inc. any reproduction or use without the written permis sion of coev, inc. is prohibited. coev xxxxx C2220 customer terminal #1 indicator eia date code and lot code 0.550 max [13.97 max] 0.550 max [13.97 max] [12.70 max] 0.100" - 0.130" [2.54 - 3.30] 5 1 2 3 4 8 7 6 9 10 0.500 max 0.047 (10) .020 sqr 10 x 10.16 .4 00 2.54 .100 component must insert fully to surface a. a 10 8 sec 1 pri 3 9 ( ic side ) 7 ( line side ) 2 4
|