  technical specification iq90-hp family product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 1 the inqor ? half-brick converter series is composed of next-generation, board-mountable, isolated, fixed switching frequency dc-dc converters that use synchronous rectification to achieve extremely high power conversion efficiency. each module is supplied completely encased to provide protection from the harsh environments seen in many industrial and transportation applications. operational features ? high efficiencies, up to 90% at ful l rated load current ? delivers full po wer wi th mi nimal de rating - no he atsink re quired ? operating input voltage range: 34 - 160 v ? fixed frequency switchi ng provides predictable emi ? no minimum load requirement protection features ? input under-voltage lockout ? output current li mit and short circuit protection ? active back bias li mit ? output over-voltage protection ? thermal shutdown mechanical features ? industry standard half-bri ck pin-out configuration ? standard size: 2.390" x 2.490" x 0.512" (60.6 x 63.1 x 13.0 mm) ? total weight: 5oz (142g) control features ? on/off control referenced to input side ? remote sense for the output voltage ? output voltage trim range of -20%, +10% safety features ? 2250 v, 30 m w input-to-output isolation ? ul/cul 60950-1 recognized (us & canada), basic insulation rating ? tuv certifi ed to en60950-1 ? meets directives which facilitates ce marking in users end product ? board and plastic components meet ul94v-0 standard ? rohs compli ant (see last page) contents page no. mechanical drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 iq90 family electri cal characteristics (all output voltages) . . . . . . . . . . 3 iq90 family standards and qual ification . . . . . . . . . . . . . . . . . . . . . . . 4 iq90 family figures (all output voltages) . . . . . . . . . . . . . . . . . . . . . . 5 iq90018hpx60 electri cal characteristics (1.8 vout) & figures . . . . . . . 6-7 iq90033hpx53 electri cal characteristics (3.3 vout) & figures . . . . . . . 8-9 iq90050hpx40 electri cal characteristics (5.0 vout) & figures . . . . . 10-11 iq90120hpx19 electri cal characteristics (12 vout) & figures . . . . . 12-13 iq90150hpx15 electri cal characteristics (15 vout) & figures . . . . . 14-15 iq90240hpx9f electri cal characteristics (24 vout) & figures . . . . . 16-17 iq90280hpx08 electri cal characteristics (28 vout) & figures . . . . . 18-19 iq90400hpx5h electrical characteristics (40 vout) & figures . . . . . 20-21 iq90480hpx4g electri cal characteristics (48 vout) & figures . . . . . 22-23 application section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-27 ordering information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 34-160 v 1.8-48 v 228 w 2250 v dc half-brick continuous input outputs max power isolation dc-dc converter
technical specification iq90-hp family product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 2 notes 1) applied torque per screw should not exceed 6in-lb. (0.7 nm). 2) baseplate flatness tolerance is 0.004" (.10 mm) tir for surface. 3) pins 1-3, 5-7 are 0.040 (1.02mm) diameter, with 0.080 (2.03mm) diameter standoff shoulders. 4) pins 4 and 8 are 0.080 (2.03 mm) dia. with 0.125 (3.18 mm) dia. 5) all pins: material: copper alloy finish: matte tin over nickel plate 6) undimensioned components are shown for visual reference only 7) weight: 4.9oz (142g) 8) threaded or non-threaded options available 9) all dimensions in inches (mm) tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm) pin designations pin name function 1 vin(+) 2 on/off ttl input to turn converter on and off, referenced to vin(C), with 3 vin(C) negative input voltage 4 vout(C) negative output voltage 5 sense(C) negative remote sense 1 6 trim output voltage trim 2 7 sense(+) 3 8 vout(+) notes: 1) sense(C) should be connected to vout(C) either 2) leave trim pin open for nominal output voltage. 3) sense(+) should be connected to vout(+) 1.90 [ 48,3 ] .400 [ 10,16 ] 1.400 [ 35,56 ] .400 [ 10,16 ] .700 [ 17,78 ] 1.000 [ 25,4 ] 1.400 [ 35,56 ] 2.386 .020 [ 60,6 0,5 ] .233 .020 [ 5,92 0,5 ] .543 .020 [ 13,79 0,5 ] 1.90 [ 48,3 ] 2.486 .020 [ 63,14 0,5 ] .243 .020 [ 6,17 0,5 ] .243 .020 [ 6,17 0,5 ] 2.00 [ 50,8 ] +.002 .512 -.005 +0,05 13 [ -0,12 ] overall height +.007 .027 -.010 +0,17 0,69 [ -0,25 ] bottomside clearance .163 [ 4,14 ] 1 2 3 4 5 6 7 8 side view top view thru hole m3 (see note 8) standoffs (4) mechanical drawing
technical specification iq90-hp family product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 3 iq90 family electrical characteristics (all output voltages) ta = 25 c, airflow rate = 300 lfm, vin = 90 v dc unless otherwise noted; full operating temperature range is -40 c to +100 c baseplate temperature with appropriate power derating. specifications subject to change without notice. parameter min. typ. max. units notes & conditions absolute maximum ratings input voltage non-operating 170 v continuous operating 160 v continuous operating transient protection 170 v isolation voltage input to output 2250 v dc input to base-plate 2250 v dc output to base-plate 2250 v dc operating temperature -40 100 c baseplate temperature storage temperature -55 125 c voltage at on/off input pin -2 18 v input characteristics operating input voltage range 34 90 160 v input under-voltage lockout turn-on voltage threshold 33.0 33.4 33.8 v turn-off voltage threshold 30.0 30.4 30.8 v lockout voltage hysteresis 3.0 v input over-voltage shutdown - v not available recommended external input capacitance 100 typical esr 0.1-0.2 input filter component values (l\c) 3.4\1.8 h\f internal values; see figure e dynamic characteristics turn-on transient turn-on time 10 ms full load, vout=90% nom. start-up inhibit time 200 230 250 ms figure f output voltage overshoot 0 % maximum output capacitance isolation characteristics isolation voltage (dielectric strength) see absolute maximum ratings isolation resistance 30 m isolation capacitance (input to output) 1000 pf see note 1 temperature limits for power derating curves semiconductor junction temperature 125 c package rated to 150 c board temperature 125 c ul rated max operating temp 130 c transformer temperature 125 c maximum baseplate temperature, tb 100 c feature characteristics switching frequency 255 275 295 khz isolation stage switching freq. is half this on/off control off-state voltage 2.4 1.8 v on-state voltage -2 0.8 on/off control application notes figures a & b pull-up voltage 5 v pull-up resistance 50 k over-temperature shutdown otp trip point 125 c average pcb temperature over-temperature shutdown restart hysteresis 10 c reliability characteristics calculated mtbf (telcordia) tr-nwt-000332 tbd 10 6 hrs. 80% load, 200lfm, 40 c ta calculated mtbf (mil-217) mil-hdbk-217f tbd 10 6 hrs. 80% load, 200lfm, 40 c ta field demonstrated mtbf 10 6 hrs. see our website for details note 1: higher values of isolation capacitance can be added external to the module.
technical specification iq90-hp family product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 4 standards compliance parameter notes & conditions standards compliance ul/cul 60950-1 file # e194341, basic insulation en60950-1 certifed by tuv needle flame test (iec 695-2-2) test on entire assembly; board & plastic components ul94v-0 compliant iec 61000-4-2 esd test, 8 kv - np, 15 kv air - np (normal performance) note: an external input fuse must always be used to meet these safety requirements. contact synqor for offcial safety certifcates on new releases or download from the synqor website. qualification testing parameter # units test conditions qualification testing life test 32 95% rated vin and load, units at derating point, 1000 hours vibration 5 10-55 hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis mechanical shock 5 100g minimum, 2 drops in x and y axis, 1 drop in z axis temperature cycling 10 -40 c to 100 c, unit temp. ramp 15 c/min., 500 cycles power/thermal cycling 5 toperating = min to max, vin = min to max, full load, 100 cycles design marginality 5 tmin-10 c to tmax+10 c, 5 c steps, vin = min to max, 0-105% load humidity 5 85 c, 85% rh, 1000 hours, continuous vin applied except 5 min/day solderability 15 pins mil-std-883, method 2003 iq90 family standards and qualification
technical specification iq90-hp family product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 5 common figure 3: trim graph for trim-up 1.8 to 12 v outputs. 0 20 40 60 80 100 120 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 load current (% ) output voltage (%) vin min vin nom vin max typical current limit inception point typical output voltage at shutdown common figure 1: typical startup waveform. input voltage pre-applied, on/off pin on ch 2. common figure 2: output voltage vs. load current showing typical current limit curves and converter shutdown points. 100.0 1,000.0 10,000.0 100,000.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 increase in vout (%) trim resistance (kohms) 15 v 24 v 28 v 40 v 48 v 10.0 100.0 1,000.0 10,000.0 100,000.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 increase in vout (%) trim resistance (kohms) 1.8 v 3.3 v 5 v 12 v 10.0 100.0 1,000.0 10,000.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 decrease in vout (%) trim resistance (kohms) all voltages common figure 5 : trim graph for trim down. common figure 4: trim graph for trim-up 15 to 48 v outputs. nominal vout iq90 family figures (all output voltages) 5.00
product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 6 technical specification input: output: current: part no.: 34 - 160 v 1.8 v 60 a iq90018hpx60 iq90018hpx60 electrical characteristics (1.8 vout) ta = 25 c, airflow rate = 300 lfm, vin = 90 v dc unless otherwise noted; full operating temperature range is -40 c to +100 c baseplate temperature with appropriate power derating. specifications subject to change without notice. parameter min. typ. max. units notes & conditions input characteristics maximum input current 5.0 a vin min; trim up; in current limit no-load input current 40 50 ma disabled input current 2.5 4 ma response to input transient 0.08 v see figure 6 input terminal ripple current 230 ma rms recommended input fuse 10 a fast acting external fuse recommended output characteristics output voltage set point 1.782 1.8 1.818 v output voltage regulation over line 0.1 0.3 % over load 0.1 0.3 % over temperature -27 27 mv total output voltage range 1.755 1.845 v over sample, line, load, temperature & life output voltage ripple and noise 20 mhz bandwidth; see note 1 peak-to-peak 0 270 540 mv full load rms 32 60 mv full load operating output current range 0 60 a subject to thermal derating output dc current-limit inception 66.0 72.0 78.0 a output voltage 10% low output dc current-limit shutdown voltage 0.8 v back-drive current limit while enabled 1.9 a negative current drawn from output back-drive current limit while disabled 0.1 ma negative current drawn from output maximum output capacitance 15,000 f vout nominal at full load (resistive load) output voltage during load current transient step change in output current (0.1 a/s) 80 mv 50% to 75% to 50% iout max settling time 700 s to within 1% vout nom output voltage trim range -20 10 % across pins 8&4; common figures 3-5; see note 2 output voltage remote sense range 10 % across pins 8&4 output over-voltage protection 2.1 2.2 2.3 v over full temp range efficiency 100% load 84 % see figure 1 for efficiency curve 50% load 87 % see figure 1 for efficiency curve note 1: output is terminated with 1 f ceramic and 15 f low-esr tantalum capacitors. for applications requiring reduced output voltage ripple and noise, consult synqor applications support (e-mail: support@synqor.com) note 2: trim-up range is limited below 10% at low line and full load.
product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 7 technical specification input: output: current: part no.: figure 1: efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 c. figure 2: power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 c. figure 3: encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 lfm through 400 lfm. air flows across the converter from input to output (nominal input voltage). figure 4: encased converter (with 1/2 heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 lfm through 400 lfm. air flows across the converter from input to output (nominal input voltage). figure 6: output voltage response to step-change in input voltage (1000 v/ms). load cap: 100 f, electrolytic output capacitance. ch 1: vout (200 mv/div), ch 2: vin (50 v/div). figure 5: output voltage response to step-change in load current (50%-75%- 50% of iout(max); di/dt = 0.1 a/ s). load cap: 1 f ceramic and 15 f tantalum capacitors. ch 1: vout ( 100 m v/div), ch 2: iout (20 a/div). 0 10 20 30 40 50 60 70 25 40 55 70 85 ambient air temperature (c) iout (a) 400 lfm (2.0 m/s) 300 lfm (1.5 m/s) 200 lfm (1.0 m/s) 100 lfm (0.5 m/s) 0 10 20 30 40 50 60 70 25 40 55 70 85 ambient air temperature (c) iout (a) 400 lfm (2.0 m/s) 300 lfm (1.5 m/s) 200 lfm (1.0 m/s) 100 lfm (0.5 m/s) 0 3 6 9 12 15 18 21 24 0 5 10 15 20 25 30 35 40 45 50 55 60 load current (a) power dissipation (w) 34 vin 90 vin 150 vin 60 65 70 75 80 85 90 95 100 0 5 10 15 20 25 30 35 40 45 50 55 60 load current (a) efficiency (%) 34 vin 90 vin 150 vin 34 - 160 v 1.8 v 60 a iq90018hpx60 34 - 160 v 1.8 v 60 a iq90018hpx60 iq90018hpx60 figures
product # iq90xxxhpxxx p hone 1-888-567-9596 www.synqor.com d oc.# 005-0005256 rev. a 0 5/26/09 p age 8 technical specification input: output: current: part no.: 34 - 160 v 3.3 v 53 a iq90033hpx53 iq90033hpx53 electrical characteristics (3.3 vout) ta = 25 c, airflow rate = 300 lfm, vin = 90 v dc unless otherwise noted; full operating temperature range is -40 c to +100 c baseplate temperature with appropriate power derating. specifications subject to change without notice. parameter min. typ. max. units notes & conditions input characteristics maximum input current 7.7 a vin min; trim up; in current limit no-load input current 50 60 ma disabled input current 2.5 4 ma response to input transient 0.11 v see figure 6 input terminal ripple current 350 ma rms recommended input fuse 10 a fast acting external fuse recommended output characteristics output voltage set point 3.267 3.3 3.333 v output voltage regulation over line 0.1 0.3 % over load 0.1 0.3 % over temperature -50 50 mv total output voltage range 3.218 3.383 v over sample, line, load, temperature & life output voltage ripple and noise 20 mhz bandwidth; see note 1 peak-to-peak 0 170 340 mv full load rms 22 40 mv full load operating output current range 0 53 a subject to thermal derating output dc current-limit inception 58.3 63.6 68.9 a output voltage 10% low output dc current-limit shutdown voltage 1.7 v back-drive current limit while enabled 1.4 a negative current drawn from output back-drive current limit while disabled 0.1 ma negative current drawn from output maximum output capacitance 10,000 f vout nominal at full load (resistive load) output voltage during load current transient step change in output current (0.1 a/s) 80 mv 50% to 75% to 50% iout max settling time 500 s to within 1% vout nom output voltage trim range -20 10 % across pins 8&4; common figures 3-5; see note 2 output voltage remote sense range 10 % across pins 8&4 output over-voltage protection 3.8 4.0 4.2 v over full temp range efficiency 100% load 89 % see figure 1 for efficiency curve 50% load 91 % see figure 1 for efficiency curve note 1: output is terminated with 1 f ceramic and 15 f low-esr tantalum capacitors. for applications requiring reduced output voltage ripple and noise, consult synqor applications support (e-mail: support@synqor.com) note 2: trim-up range is limited below 10% at low line and full load.
product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 9 technical specification input: output: current: part no.: figure 1: efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 c. figure 2: power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 c. figure 3: encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 lfm through 400 lfm. air flows across the converter from input to output (nominal input voltage). figure 4: encased converter (with 1/2 heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 lfm through 400 lfm. air flows across the converter from input to output (nominal input voltage). figure 6: output voltage response to step-change in input voltage (1000 v/ms). load cap: 100 f, electrolytic output capacitance. ch 1: vout (200 mv/div), ch 2: vin (50 v/div). figure 5: output voltage response to step-change in load current (50%-75%- 50% of iout(max); di/dt = 0.1 a/ s). load cap: 1 f ceramic and 15 f tantalum capacitors. ch 1: vout ( 100 m v/div), ch 2: iout (20 a/div). 0 10 20 30 40 50 60 25 40 55 70 85 ambient air temperature (c) iout (a) 400 lfm (2.0 m/s) 300 lfm (1.5 m/s) 200 lfm (1.0 m/s) 100 lfm (0.5 m/s) 0 10 20 30 40 50 60 25 40 55 70 85 ambient air temperature (c) iout (a) 400 lfm (2.0 m/s) 300 lfm (1.5 m/s) 200 lfm (1.0 m/s) 100 lfm (0.5 m/s) 0 3 6 9 12 15 18 21 24 27 0 5 10 15 20 25 30 35 40 45 50 55 load current (a) power dissipation (w) 34 vin 90 vin 150 vin 60 65 70 75 80 85 90 95 100 0 5 10 15 20 25 30 35 40 45 50 55 load current (a) efficiency (%) 34 vin 90 vin 150 vin 34 - 160 v 3.3 v 53 a iq90033hpx53 34 - 160 v 3.3 v 53 a iq90033hpx53 iq90033hpx53 figures
product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 10 technical specification input: output: current: part no.: 34 - 160 v 5.0 v 40 a iq90050hpx40 iq90050hpx40 electrical characteristics (5.0 vout) ta = 25 c, airflow rate = 300 lfm, vin = 90 v dc unless otherwise noted; full operating temperature range is -40 c to +100 c baseplate temperature with appropriate power derating. specifications subject to change without notice. parameter min. typ. max. units notes & conditions input characteristics maximum input current 8.9 a vin min; trim up; in current limit no-load input current 40 50 ma disabled input current 3 4 ma response to input transient 0.2 v see figure 6 input terminal ripple current 400 ma rms recommended input fuse 10 a fast acting external fuse recommended output characteristics output voltage set point 4.95 5 5.05 v output voltage regulation over line 0.1 0.3 % over load 0.1 0.3 % over temperature -75 75 mv total output voltage range 4.875 5.125 v over sample, line, load, temperature & life output voltage ripple and noise 20 mhz bandwidth; see note 1 peak-to-peak 0 150 300 mv full load rms 21 40 mv full load operating output current range 0 40 a subject to thermal derating output dc current-limit inception 44.0 48.0 52.0 a output voltage 10% low output dc current-limit shutdown voltage 2.6 v back-drive current limit while enabled 0.5 a negative current drawn from output back-drive current limit while disabled 0.4 ma negative current drawn from output maximum output capacitance 8,000 f vout nominal at full load (resistive load) output voltage during load current transient step change in output current (0.1 a/s) 140 mv 50% to 75% to 50% iout max settling time 500 s to within 1% vout nom output voltage trim range -20 10 % across pins 8&4; common figures 3-5 output voltage remote sense range 10 % across pins 8&4 output over-voltage protection 5.8 6.1 6.4 v over full temp range efficiency 100% load 87 % see figure 1 for efficiency curve 50% load 90 % see figure 1 for efficiency curve note 1: output is terminated with 1 f ceramic and 15 f low-esr tantalum capacitors. for applications requiring reduced output voltage ripple and noise, consult synqor applications support (e-mail: support@synqor.com)
product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 11 technical specification input: output: current: part no.: figure 1: efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 c. figure 2: power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 c. figure 3: encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 lfm through 400 lfm. air flows across the converter from input to output (nominal input voltage). figure 4: encased converter (with 1/2 heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 lfm through 400 lfm. air flows across the converter from input to output (nominal input voltage). figure 6: output voltage response to step-change in input voltage (1000 v/ms). load cap: 100 f, electrolytic output capacitance. ch 1: vout (500 mv/div), ch 2: vin (50 v/div). figure 5: output voltage response to step-change in load current (50%-75%- 50% of iout(max); di/dt = 0.1 a/ s). load cap: 1 f ceramic and 15 f tantalum capacitors. ch 1: vout ( 200 m v/div), ch 2: iout (20 a/div). 0 5 10 15 20 25 30 35 40 45 25 40 55 70 85 ambient air temperature (c) iout (a) 400 lfm (2.0 m/s) 300 lfm (1.5 m/s) 200 lfm (1.0 m/s) 100 lfm (0.5 m/s) 0 5 10 15 20 25 30 35 40 45 25 40 55 70 85 ambient air temperature (c) iout (a) 400 lfm (2.0 m/s) 300 lfm (1.5 m/s) 200 lfm (1.0 m/s) 100 lfm (0.5 m/s) 0 5 10 15 20 25 30 35 0 5 10 15 20 25 30 35 40 load current (a) power dissipation (w) 34 vin 90 vin 150 vin 60 65 70 75 80 85 90 95 100 0 5 10 15 20 25 30 35 40 load current (a) efficiency (%) 34 vin 90 vin 150 vin 34 - 160 v 5.0 v 40 a iq90050hpx40 34 - 160 v 5.0 v 40 a iq90050hpx40 iq90050hpx40 figures
product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 12 technical specification input: output: current: part no.: 34 - 160 v 12 v 19 a iq90120hpx19 iq90120hpx19 electrical characteristics (12 vout) ta = 25 c, airflow rate = 300 lfm, vin = 90 v dc unless otherwise noted; full operating temperature range is -40 c to +100 c baseplate temperature with appropriate power derating. specifications subject to change without notice. parameter min. typ. max. units notes & conditions input characteristics maximum input current 9.8 a vin min; trim up; in current limit no-load input current 50 60 ma disabled input current 3 5 ma response to input transient 0.5 v 1000 v/ms, see figure 6 input terminal ripple current 320 ma rms recommended input fuse 10 a fast acting external fuse recommended output characteristics output voltage set point 11.88 12 12.12 v output voltage regulation over line 0.1 0.3 % over load 0.1 0.3 % over temperature -180 180 mv total output voltage range 11.700 12.300 v over sample, line, load, temperature & life output voltage ripple and noise 20 mhz bandwidth; see note 1 peak-to-peak 0 100 200 mv full load rms 17 30 mv full load operating output current range 0 19 a subject to thermal derating output dc current-limit inception 20.9 22.8 24.7 a output voltage 10% low output dc current-limit shutdown voltage 6 v back-drive current limit while enabled 0.5 a negative current drawn from output back-drive current limit while disabled 1 ma negative current drawn from output maximum output capacitance 1,500 f vout nominal at full load (resistive load) output voltage during load current transient step change in output current (0.1 a/s) 320 mv 50% to 75% to 50% iout max settling time 80 s to within 1% vout nom output voltage trim range -20 10 % across pins 8&4; common figures 3-5; see note 2 output voltage remote sense range 10 % across pins 8&4 output over-voltage protection 14.0 14.6 15.3 v over full temp range efficiency 100% load 90 % see figure 1 for efficiency curve 50% load 92 % see figure 1 for efficiency curve note 1: output is terminated with 1 f ceramic and 15 f low-esr tantalum capacitors. for applications requiring reduced output voltage ripple and noise, consult synqor applications support (e-mail: support@synqor.com) note 2: trim-up range is limited below 10% at low line and full load.
product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 13 technical specification input: output: current: part no.: figure 1: efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 c. figure 2: power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 c. figure 3: encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 lfm through 400 lfm. air flows across the converter from input to output (nominal input voltage). figure 4: encased converter (with 1/2 heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 lfm through 400 lfm. air flows across the converter from input to output (nominal input voltage). figure 6: output voltage response to step-change in input voltage (1000 v/ms). load cap: 100 f, electrolytic output capacitance. ch 1: vout (500 mv/div), ch 2: vin (50 v/div). figure 5: output voltage response to step-change in load current (50%-75%- 50% of iout(max); di/dt = 0.1 a/ s). load cap: 1 f ceramic and 15 f tantalum capacitors. ch 1: vout ( 200 m v/div), ch 2: iout (5 a/div). 0 3 6 9 12 15 18 21 24 27 30 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 load current (a) power dissipation (w) 34 vin 90 vin 150 vin 60 65 70 75 80 85 90 95 100 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 load current (a) efficiency (%) 34 vin 90 vin 150 vin 0 2 4 6 8 10 12 14 16 18 20 25 40 55 70 85 ambient air temperature (c) iout (a) 400 lfm (2.0 m/s) 300 lfm (1.5 m/s) 200 lfm (1.0 m/s) 100 lfm (0.5 m/s) 0 2 4 6 8 10 12 14 16 18 20 25 40 55 70 85 ambient air temperature (c) iout (a) 400 lfm (2.0 m/s) 300 lfm (1.5 m/s) 200 lfm (1.0 m/s) 100 lfm (0.5 m/s) 34 - 160 v 12 v 19 a iq90120hpx19 34 - 160 v 12 v 19 a iq90120hpx19 iq90120hpx19 figures
product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 14 technical specification input: output: current: part no.: 34 - 160 v 15 v 15 a iq90150hpx15 iq90150hpx15 electrical characteristics (15 vout) ta = 25 c, airflow rate = 300 lfm, vin = 90 v dc unless otherwise noted; full operating temperature range is -40 c to +100 c baseplate temperature with appropriate power derating. specifications subject to change without notice. parameter min. typ. max. units notes & conditions input characteristics maximum input current 9.8 a vin min; trim up; in current limit no-load input current 50 60 ma disabled input current 2.5 4 ma response to input transient 0.55 v see figure 6 input terminal ripple current 490 ma rms recommended input fuse 10 a fast acting external fuse recommended output characteristics output voltage set point 14.85 15 15.15 v output voltage regulation over line 0.1 0.3 % over load 0.1 0.3 % over temperature -225 225 mv total output voltage range 14.625 15.375 v over sample, line, load, temperature & life output voltage ripple and noise 20 mhz bandwidth; see note 1 peak-to-peak 0 100 200 mv full load rms 18 40 mv full load operating output current range 0 15 a subject to thermal derating output dc current-limit inception 16.5 18.0 19.5 a output voltage 10% low output dc current-limit shutdown voltage 8 v back-drive current limit while enabled 0.4 a negative current drawn from output back-drive current limit while disabled 1.5 ma negative current drawn from output maximum output capacitance 1,000 f vout nominal at full load (resistive load) output voltage during load current transient step change in output current (0.1 a/s) 520 mv 50% to 75% to 50% iout max settling time 80 s to within 1% vout nom output voltage trim range -20 10 % across pins 8&4; common figures 3-5; see note 2 output voltage remote sense range 10 % across pins 8&4 output over-voltage protection 17.5 18.3 19.1 v over full temp range efficiency 100% load 90 % see figure 1 for efficiency curve 50% load 92 % see figure 1 for efficiency curve note 1: output is terminated with 1 f ceramic and 15 f low-esr tantalum capacitors. for applications requiring reduced output voltage ripple and noise, consult synqor applications support (e-mail: support@synqor.com) note 2: trim-up range is limited below 10% at low line and full load.
product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 15 technical specification input: output: current: part no.: figure 1: efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 c. figure 2: power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 c. figure 3: encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 lfm through 400 lfm. air flows across the converter from input to output (nominal input voltage). figure 4: encased converter (with 1/2 heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 lfm through 400 lfm. air flows across the converter from input to output (nominal input voltage). figure 6: output voltage response to step-change in input voltage (1000 v/ms). load cap: 100 f, electrolytic output capacitance. ch 1: vout (1 v/div), ch 2: vin (50 v/div). figure 5: output voltage response to step-change in load current (50%-75%- 50% of iout(max); di/dt = 0.1 a/ s). load cap: 1 f ceramic and 15 f tantalum capacitors. ch 1: vout ( 1 v/div), ch 2: iout (5 a/div). 0 2 4 6 8 10 12 14 16 25 40 55 70 85 ambient air temperature (c) iout (a) 400 lfm (2.0 m/s) 300 lfm (1.5 m/s) 200 lfm (1.0 m/s) 100 lfm (0.5 m/s) 0 2 4 6 8 10 12 14 16 25 40 55 70 85 ambient air temperature (c) iout (a) 400 lfm (2.0 m/s) 300 lfm (1.5 m/s) 200 lfm (1.0 m/s) 100 lfm (0.5 m/s) 0 3 6 9 12 15 18 21 24 27 30 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 load current (a) power dissipation (w) 34 vin 90 vin 150 vin 60 65 70 75 80 85 90 95 100 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 load current (a) efficiency (%) 34 vin 90 vin 150 vin 34 - 160 v 15 v 15 a iq90150hpx15 34 - 160 v 15 v 15 a iq90150hpx15 iq90150hpx15 figures
product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 16 technical specification input: output: current: part no.: 34 - 160 v 24 v 9.5 a iq90240hpx9f iq90240hpx9f electrical characteristics (24 vout) ta = 25 c, airflow rate = 300 lfm, vin = 90 v dc unless otherwise noted; full operating temperature range is -40 c to +100 c baseplate temperature with appropriate power derating. specifications subject to change without notice. parameter min. typ. max. units notes & conditions input characteristics maximum input current 10.1 a vin min; trim up; in current limit no-load input current 40 50 ma disabled input current 2 3 ma response to input transient 0.75 v see figure 6 input terminal ripple current 530 ma rms recommended input fuse 10 a fast acting external fuse recommended output characteristics output voltage set point 23.76 24 24.24 v output voltage regulation over line 0.1 0.3 % over load 0.1 0.3 % over temperature -360 360 mv total output voltage range 23.40 24.60 v over sample, line, load, temperature & life output voltage ripple and noise 20 mhz bandwidth; see note 1 peak-to-peak 0 85 170 mv full load rms 18 40 mv full load operating output current range 0 9.5 a subject to thermal derating output dc current-limit inception 10.4 11.4 12.4 a output voltage 10% low output dc current-limit shutdown voltage 13 v back-drive current limit while enabled 0.2 a negative current drawn from output back-drive current limit while disabled 2.5 ma negative current drawn from output maximum output capacitance 400 f vout nominal at full load (resistive load) output voltage during load current transient step change in output current (0.1 a/s) 1200 mv 50% to 75% to 50% iout max settling time 80 s to within 1% vout nom output voltage trim range -20 10 % across pins 8&4; common figures 3-5 output voltage remote sense range 10 % across pins 8&4 output over-voltage protection 28.0 29.3 30.5 v over full temp range efficiency 100% load 88 % see figure 1 for efficiency curve 50% load 91 % see figure 1 for efficiency curve note 1: output is terminated with 1 f ceramic capacitor. for applications requiring reduced output voltage ripple and noise, consult synqor applications support (e-mail: support@synqor.com)
product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 17 technical specification input: output: current: part no.: figure 1: efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 c. figure 2: power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 c. figure 3: encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 lfm through 400 lfm. air flows across the converter from input to output (nominal input voltage). figure 4: encased converter (with 1/2 heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 lfm through 400 lfm. air flows across the converter from input to output (nominal input voltage). 34 - 160 v 24 v 9.5 a iq90240hpx9f figure 6: output voltage response to step-change in input voltage (1000 v/ms). load cap: 100 f, electrolytic output capacitance. ch 1: vout (1 v/div), ch 2: vin (50 v/div). figure 5: output voltage response to step-change in load current (50%-75%- 50% of iout(max); di/dt = 0.1 a/ s). load cap: 1 f ceramic capacitor. ch 1: vout (2 v/div), ch 2: iout (5 a/div). 0 1 2 3 4 5 6 7 8 9 10 25 40 55 70 85 ambient air temperature (c) iout (a) 400 lfm (2.0 m/s) 300 lfm (1.5 m/s) 200 lfm (1.0 m/s) 100 lfm (0.5 m/s) 0 1 2 3 4 5 6 7 8 9 10 25 40 55 70 85 ambient air temperature (c) iout (a) 400 lfm (2.0 m/s) 300 lfm (1.5 m/s) 200 lfm (1.0 m/s) 100 lfm (0.5 m/s) 0 5 10 15 20 25 30 35 40 0 1 2 3 4 5 6 7 8 9 10 load current (a) power dissipation (w) 34 vin 90 vin 150 vin 60 65 70 75 80 85 90 95 100 0 1 2 3 4 5 6 7 8 9 10 load current (a) efficiency (%) 34 vin 90 vin 150 vin 34 - 160 v 24 v 9.5 a iq90240hpx9f iq90240hpx9f figures
product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 18 technical specification input: output: current: part no.: 34 - 160 v 28 v 8.0 a iq90280hpx08 iq90280hpx08 electrical characteristics (28 vout) ta = 25 c, airflow rate = 300 lfm, vin = 90 v dc unless otherwise noted; full operating temperature range is -40 c to +100 c baseplate temperature with appropriate power derating. specifications subject to change without notice. parameter min. typ. max. units notes & conditions input characteristics maximum input current 9.8 a vin min; trim up; in current limit no-load input current 45 60 ma disabled input current 2.5 4 ma response to input transient 0.8 v see figure 6 input terminal ripple current 460 ma rms recommended input fuse 10 a fast acting external fuse recommended output characteristics output voltage set point 27.72 28 28.28 v output voltage regulation over line 0.1 0.3 % over load 0.1 0.3 % over temperature -420 420 mv total output voltage range 27.30 28.70 v over sample, line, load, temperature & life output voltage ripple and noise 20 mhz bandwidth; see note 1 peak-to-peak 0 140 280 mv full load rms 25 50 mv full load operating output current range 0 8 a subject to thermal derating output dc current-limit inception 8.8 9.6 10.4 a output voltage 10% low output dc current-limit shutdown voltage 16 v back-drive current limit while enabled 0.15 a negative current drawn from output back-drive current limit while disabled 3 ma negative current drawn from output maximum output capacitance 250 f vout nominal at full load (resistive load) output voltage during load current transient step change in output current (0.1 a/s) 1400 mv 50% to 75% to 50% iout max settling time 80 s to within 1% vout nom output voltage trim range -20 10 % across pins 8&4; common figures 3-5 output voltage remote sense range 10 % across pins 8&4 output over-voltage protection 32.7 34.2 35.6 v over full temp range efficiency 100% load 89 % see figure 1 for efficiency curve 50% load 91 % see figure 1 for efficiency curve note 1: output is terminated with 1 f ceramic capacitor. for applications requiring reduced output voltage ripple and noise, consult synqor applications support (e-mail: support@synqor.com)
product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 19 technical specification input: output: current: part no.: figure 1: efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 c. figure 2: power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 c. figure 3: encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 lfm through 400 lfm. air flows across the converter from input to output (nominal input voltage). figure 4: encased converter (with 1/2 heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 lfm through 400 lfm. air flows across the converter from input to output (nominal input voltage). figure 6: output voltage response to step-change in input voltage (1000 v/ms). load cap: 100 f, electrolytic output capacitance. ch 1: vout (1 v/div), ch 2: vin (50 v/div). figure 5: output voltage response to step-change in load current (50%-75%- 50% of iout(max); di/dt = 0.1 a/ s). load cap: 1 f ceramic capacitor. ch 1: vout ( 2 v/div), ch 2: iout (2 a/div). 0 1 2 3 4 5 6 7 8 9 25 40 55 70 85 ambient air temperature (c) iout (a) 400 lfm (2.0 m/s) 300 lfm (1.5 m/s) 200 lfm (1.0 m/s) 100 lfm (0.5 m/s) 0 1 2 3 4 5 6 7 8 9 25 40 55 70 85 ambient air temperature (c) iout (a) 400 lfm (2.0 m/s) 300 lfm (1.5 m/s) 200 lfm (1.0 m/s) 100 lfm (0.5 m/s) 60 65 70 75 80 85 90 95 100 0 1 2 3 4 5 6 7 8 load current (a) efficiency (%) 34 vin 90 vin 150 vin 60 65 70 75 80 85 90 95 100 0 1 2 3 4 5 6 7 8 load current (a) efficiency (%) 34 vin 90 vin 150 vin 34 - 160 v 28 v 8.0 a iq90280hpx08 34 - 160 v 28 v 8.0 a iq90280hpx08 iq90280hpx08 figures
product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 20 technical specification input: output: current: part no.: 34 - 160 v 40 v 5.7 a iq90400hpx5h iq90400hpx5h electrical characteristics (40 vout) ta = 25 c, airflow rate = 300 lfm, vin = 90 v dc unless otherwise noted; full operating temperature range is -40 c to +100 c baseplate temperature with appropriate power derating. specifications subject to change without notice. parameter min. typ. max. units notes & conditions input characteristics maximum input current 9.9 a vin min; trim up; in current limit no-load input current 50 60 ma disabled input current 2.5 4 ma response to input transient 0.9 v see figure 6 input terminal ripple current 460 ma rms recommended input fuse 10 a fast acting external fuse recommended output characteristics output voltage set point 39.6 40 40.4 v output voltage regulation over line 0.1 0.3 % over load 0.1 0.3 % over temperature -600 600 mv total output voltage range 39.00 41.00 v over sample, line, load, temperature & life output voltage ripple and noise 20 mhz bandwidth; see note 1 peak-to-peak 0 125 250 mv full load rms 25 50 mv full load operating output current range 0 5.7 a subject to thermal derating output dc current-limit inception 6.27 6.84 7.41 a output voltage 10% low output dc current-limit shutdown voltage 23 v back-drive current limit while enabled 0.13 a negative current drawn from output back-drive current limit while disabled 4 ma negative current drawn from output maximum output capacitance 150 f vout nominal at full load (resistive load) output voltage during load current transient step change in output current (0.1 a/s) 2100 mv 50% to 75% to 50% iout max settling time 80 s to within 1% vout nom output voltage trim range -20 10 % across pins 8&4; common figures 3-5; see note 2 output voltage remote sense range 10 % across pins 8&4 output over-voltage protection 46.8 48.8 50.8 v over full temp range efficiency 100% load 89 % see figure 1 for efficiency curve 50% load 91 % see figure 1 for efficiency curve note 1: output is terminated with 1 f ceramic capacitor. for applications requiring reduced output voltage ripple and noise, consult synqor applications support (e-mail: support@synqor.com) note 2: trim-up range is limited below 10% at low line and full load.
product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 21 technical specification input: output: current: part no.: figure 1: efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 c. figure 2: power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 c. figure 3: encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 lfm through 400 lfm. air flows across the converter from input to output (nominal input voltage). figure 4: encased converter (with 1/2 heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 lfm through 400 lfm. air flows across the converter from input to output (nominal input voltage). figure 6: output voltage response to step-change in input voltage (1000 v/ms). load cap: 100 f, electrolytic output capacitance. ch 1: vout (1 v/div), ch 2: vin (50 v/div). figure 5: output voltage response to step-change in load current (50%-75%- 50% of iout(max); di/dt = 0.05 a/ s). load cap: 1 f ceramic capacitor. ch 1: vout ( 2 v/div), ch 2: iout (2 a/div). 0 1 2 3 4 5 6 25 40 55 70 85 ambient air temperature (c) iout (a) 400 lfm (2.0 m/s) 300 lfm (1.5 m/s) 200 lfm (1.0 m/s) 100 lfm (0.5 m/s) 0 1 2 3 4 5 6 25 40 55 70 85 ambient air temperature (c) iout (a) 400 lfm (2.0 m/s) 300 lfm (1.5 m/s) 200 lfm (1.0 m/s) 100 lfm (0.5 m/s) 0 5 10 15 20 25 30 35 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 load current (a) power dissipation (w) 34 vin 90 vin 150 vin 60 65 70 75 80 85 90 95 100 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 load current (a) efficiency (%) 34 vin 90 vin 150 vin 34 - 160 v 40 v 5.7 a iq90400hpx5h 34 - 160 v 40 v 5.7 a iq90400hpx5h iq90400hpx5h figures
product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 22 technical specification input: output: current: part no.: 34 - 160 v 48 v 4.6 a iq90480hpx4g iq90480hpx4g electrical characteristics (48 vout) ta = 25 c, airflow rate = 300 lfm, vin = 90 v dc unless otherwise noted; full operating temperature range is -40 c to +100 c baseplate temperature with appropriate power derating. specifications subject to change without notice. parameter min. typ. max. units notes & conditions input characteristics maximum input current 9.6 a vin min; trim up; in current limit no-load input current 50 60 ma disabled input current 2.5 4 ma response to input transient 1 v see figure 6 input terminal ripple current 440 ma rms recommended input fuse 10 a fast acting external fuse recommended output characteristics output voltage set point 47.52 48 48.48 v output voltage regulation over line 0.1 0.3 % over load 0.1 0.3 % over temperature -720 720 mv total output voltage range 46.80 49.20 v over sample, line, load, temperature & life output voltage ripple and noise 20 mhz bandwidth; see note 1 peak-to-peak 0 110 220 mv full load rms 22 40 mv full load operating output current range 0 4.6 a subject to thermal derating output dc current-limit inception 5.0 5.5 6.0 a output voltage 10% low output dc current-limit shutdown voltage 27 v back-drive current limit while enabled 0.1 a negative current drawn from output back-drive current limit while disabled 5 ma negative current drawn from output maximum output capacitance 100 f vout nominal at full load (resistive load) output voltage during load current transient step change in output current (0.1 a/s) 2300 mv 50% to 75% to 50% iout max settling time 80 s to within 1% vout nom output voltage trim range -20 10 % across pins 8&4; common figures 3-5; see note 2 output voltage remote sense range 10 % across pins 8&4 output over-voltage protection 56.1 58.6 61.0 v over full temp range efficiency 100% load 89 % see figure 1 for efficiency curve 50% load 92 % see figure 1 for efficiency curve note 1: output is terminated with 1 f ceramic capacitor. for applications requiring reduced output voltage ripple and noise, consult synqor applications support (e-mail: support@synqor.com) note 2: trim-up range is limited below 10% at low line and full load.
product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 23 technical specification input: output: current: part no.: 34 - 160 v 48 v 4.6 a iq90480hpx4g 34 - 160 v 48 v 4.6 a iq90480hpx4g 0 5 10 15 20 25 30 35 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 load current (a) power dissipation (w) 34 vin 90 vin 150 vin figure 1: efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 c. figure 2: power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 c. 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 25 40 55 70 85 ambient air temperature (c) iout (a) 400 lfm (2.0 m/s) 300 lfm (1.5 m/s) 200 lfm (1.0 m/s) 100 lfm (0.5 m/s) 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 25 40 55 70 85 ambient air temperature (c) iout (a) 400 lfm (2.0 m/s) 300 lfm (1.5 m/s) 200 lfm (1.0 m/s) 100 lfm (0.5 m/s) figure 3: encased converter (without heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 lfm through 400 lfm. air flows across the converter from input to output (nominal input voltage). figure 4: encased converter (with 1/2 heatsink) max. output power derating vs. ambient air temperature for airflow rates of 100 lfm through 400 lfm. air flows across the converter from input to output (nominal input voltage). 60 65 70 75 80 85 90 95 100 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 load current (a) efficiency (%) 34 vin 90 vin 150 vin figure 5: output voltage response to step-change in load current (50%-75%- 50% of iout(max); di/dt = 0.05 a/ s). load cap: 1 f ceramic capacitor. ch 1: vout ( 2 v/div), ch 2: iout (2 a/div). figure 6: output voltage response to step-change in input voltage (1000 v/ms). load cap: 100 f, electrolytic output capacitance. ch 1: vout (1 v/div), ch 2: vin (50 v/div). iq90480hpx4g figures
technical specification iq90-hp family product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 24 basic operation and features this converter series uses a two-stage power conversion topology. the first stage is a buck-converter that keeps the output voltage constant over variations in line, load, and temperature. the second stage uses a transformer to provide the functions of input/output isolation and voltage step-up or step-down to achieve the output voltage required. both the first stage and the second stage switch at a fixed frequency for predictable emi performance. rectification of the transformers output is accomplished with synchronous rectifiers. these devices, which are mosfets with a very low on-state resistance, dissipate far less energy than schottky diodes. this is the primary reason that the converter has such high efficiency, even at very low output voltages and very high output currents. these converters are offered totally encased to withstand harsh environments and thermally demanding applications. dissipation throughout the converter is so low that it does not require a heatsink for operation in many applications; however, adding a heatsink provides improved thermal derating performance in extreme situations. this series of converters use the industry standard footprint and pin-out configuration. control features remote on/off (pin 2 ): the on/off input, pin 2, permits the user to control when the converter is on or off. this input is referenced to the return terminal of the input bus, vin(-). the on/off signal is active low (meaning that a low turns the converter on). figure a details four possible circuits for driving the on/off pin. figure b is a detailed look of the internal on/ off circuitry. remote sense(+) (pins 7 and 5) : the sense(+) inputs correct for voltage drops along the conductors that connect the converters output pins to the load. pin 7 should be connected to vout(+) and pin 5 should be connected to vout(-) at the point on the board where regulation is desired. a remote connection at the load can adjust for a voltage drop only as large as that specified in this datasheet, that is [ vout(+) - vout(-) ] C [v sense(+) - v sense(-) ] < sense range % x vout pins 7 and 5 must be connected for proper regulation of the output voltage. if these connections are not made, the converter will deliver an output voltage that is slightly higher than its specified value. note: the output over-voltage protection circuit senses the voltage across the output (pins 8 and 4) to determine when it should trigger, not the voltage across the converters sense leads (pins 7 and 5). therefore, the resistive drop on the board should be small enough so that output ovp does not trigger, even during load transients. open collector enable circuit remote enable circuit direct logic drive negative logic (permanently enabled) on/off vin( _ ) on/off on/off vin( _ ) on/off 5v ttl/ cmos vin( _ ) vin( _ ) figure a: various circuits for driving the on/off pin. figure b: internal on/off pin circuitry ttl 5v 50k 50k on/off v in( _ ) 100pf application section
technical specification iq90-hp family product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 25 output voltage trim (pin 6) : the trim input permits the user to adjust the output voltage across the sense leads up or down according to the trim range specifications. to decrease the output voltage, the user should connect a resistor between pin 6 and pin 5 (sense(-) input). for a desired decrease of the nominal output voltage, the value of the resistor should be r trim-down = ( 511 ) - 10.22 (k w ) ? % where ?% = v nominal C v desired x 100% v nominal to increase the output voltage, the user should connect a resistor between pin 6 and pin 7 (sense(+) input). for a desired increase of the nominal output voltage, the value of the resistor should be trim graphs show the relationship between the trim resistor value and rtrim-up and rtrim-down, showing the total range the output voltage can be trimmed up or down. note: the trim feature does not affect the voltage at which the output over-voltage protection circuit is triggered. trimming the output voltage too high may cause the over-voltage protection circuit to engage, particularly during transients. it is not necessary for the user to add capacitance at the trim pin. the node is internally bypassed to eliminate noise. total dc variation of v out : for the converter to meet its full specifications, the maximum variation of the dc value of v out , due to both trimming and remote load voltage drops, should not be greater than that specified for the output voltage trim range. protection features input under-voltage lockout : the converter is designed to turn off when the input voltage is too low, helping avoid an input system instability problem, described in more detail in the application note titled input system instability on our website. the lockout circuitry is a comparator with dc hysteresis. when the input voltage is rising, it must exceed the typical turn- on voltage threshold value (listed on the specifications page) before the converter will turn on. once the converter is on, the input voltage must fall below the typical turn-off voltage threshold value before the converter will turn off. output current limit : the maximum current limit remains constant as the output voltage drops. however, once the impedance of the load across the output is small enough to make the output voltage drop below the specified output dc current- limit shutdown voltage, the converter turns off. the converter then enters a hiccup mode where it repeatedly turns on and off at a 5 hz (nominal) frequency with a 5% duty cycle until the short circuit condition is removed. this prevents excessive heating of the converter or the load board. output over-voltage limit : if the voltage across the output pins exceeds the output over-voltage protection threshold, the converter will immediately stop switching. this prevents damage to the load circuit due to 1) excessive series resistance in output current path from converter output pins to sense point, 2) a release of a short-circuit condition, or 3) a release of a current limit condition. load capacitance determines exactly how high the output voltage will rise in response to these conditions. after 200 ms the converter will automatically restart. over-temperature shutdown : a temperature sensor on the converter senses the average temperature of the module. the thermal shutdown circuit is designed to turn the converter off when the temperature at the sensed location reaches the over-temperature shutdown value. it will allow the converter to turn on again when the temperature of the sensed location falls by the amount of the over-temperature shutdown restart hysteresis value. r trim-up (k w ) where v out = nominal output voltage 511 _ 10.22 5.11v out x ( 100+ ? % ) 1.225 ? % ? % ) = ( _
technical specification iq90-hp family product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 26 application considerations figure c: typical application circuit (negative logic unit, permanently enabled). figure d: internal input filter diagram (component values listed on the specifications page). v in external input filter trim v in(+) i load c load v out(+) r trim-up or r trim-down v sense(+) on/off v in( _ ) v out( _ ) v sense( _ ) electrolytic capacitor input system instability: this condition can occur because any dc-dc converter appears incrementally as a negative resistance load. a detailed application note titled input system instability is available on the synqor website which provides an understanding of why this instability arises, and shows the preferred solution for correcting it. application circuits: figure c provides a typical circuit diagram which details the input filtering and voltage trimming. input filtering and external capacitance: figure d provides a diagram showing the internal input filter components. this filter dramatically reduces input terminal ripple current, which otherwise could exceed the rating of an external electrolytic input capacitor. the recommended external input capacitance is specified in the input characteristics section on the electrical characteristics page. more detailed information is available in the application note titled emi characteristics on the synqor website. c l v in(+) v in( _ )
technical specification iq90-hp family product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 27 startup inhibit period: the startup inhibit period ensures that the converter will remain off for approximately 200 ms when it is shut down for any reason. when an output short is present, this generates a 5 hz hiccup mode, which prevents the converter from overheating. in all, there are seven ways that the converter can be shut down, initiating a startup inhibit period: ? input under-voltage lockout ? input over-voltage shutdown ? output over-voltage protection ? over temperature shutdown ? current limit ? short circuit protection ? turned off by the on/off input figure e shows three turn-on scenarios, where a startup inhibit period is initiated at t 0 , t 1 , and t 2 : before time t 0 , when the input voltage is below the uvl threshold, the unit is disabled by the input under-voltage lockout feature. when the input voltage rises above the uvl threshold, the input under-voltage lockout is released, and a startup inhibit period is initiated. at the end of this delay, the on/off pin is evaluated, and since it is active, the unit turns on. at time t 1 , the unit is disabled by the on/off pin, and it cannot be enabled again until the startup inhibit period has elapsed. when the on/off pin goes high after t 2 , the startup inhibit period has elapsed, and the output turns on within the typical turn-on time. thermal considerations: the maximum operating base-plate temperature, t b , is 100 oc. as long as the users thermal system keeps t b < 100 oc, the converter can deliver its full rated power. a power derating curve can be calculated for any heatsink that is attached to the base-plate of the converter. it is only necessary to determine the thermal resistance, r th ba , of the chosen heatsink between the base-plate and the ambient air for a given airflow rate. this information is usually available from the heatsink vendor. the following formula can the be used to determine the maximum power the converter can dissipate for a given thermal condition if its base-plate is to be no higher than 100 oc. p max = 100 oc - t a diss r th ba this value of power dissipation can then be used in conjunction with the data shown in figure 2 to determine the maximum load current (and power) that the converter can deliver in the given thermal condition. for convenience, power derating curves for an encased converter without a heatsink and with a typical heatsink are provided for each output voltage. figure e: startup inhibit period (turn-on time not to scale) under-voltage lockout turn- on threshold on/off (neg logic) v out v in 200ms 200ms 200ms (typical start-up inhibit period) t 0 t 1 t 2 t 9ms (typical turn on time) on on on off off application section
technical specification iq90-hp family product # iq90xxxhpxxx ph one 1-888-567-9596 www.synqor.com doc.# 005-0005256 rev. b 5/6/10 pa ge 28 part numbering system the part nu mbering sy stem fo r sy nqors dc -dc co nverters follows the format shown in the example below. the first 12 ch aracters co mprise th e ba se pa rt nu mber an d the last 3 ch aracters in dicate av ailable op tions. th e - g suffix indicates 6/ 6 ro hs co mpliance. application notes a variety of ap plication no tes an d te chnical wh ite pa pers ca n be downloaded in pdf format from our website. rohs compliance: the eu led ro hs (r estriction of ha zardous substances) di rective ba ns th e us e of le ad, ca dmium, he xavalent chromium, me rcury, po lybrominated bi phenyls (p bb), an d polybrominated di phenyl et her (p bde) in el ectrical an d el ectronic equipment. th is sy nqor pr oduct is 6/ 6 ro hs co mpliant. fo r more information pl ease re fer to sy nqors ro hs ad dendum available at our rohs compliance / le ad fr ee in itiative we b page or e-mail us at rohs@synqor.com . ordering information the tables below show the valid model numbers and ordering options for converters in this product family. when ordering synqor converters, pl ease en sure th at yo u us e th e co mplete 15 character pa rt nu mber co nsisting of th e 12 ch aracter base part number and the additional characters for options. add -g to th e mo del nu mber fo r 6/ 6 ro hs co mpliance. the following options must be included in place of the w x y z spaces in the model numbers listed above. not all combinations ma ke va lid pa rt nu mbers, pl ease co ntact synqor for av ailability. see the product summary web page for more options. patents synqor holds the followi ng patents, one or more of which might apply to this product: 5,999,417 6,222,742 6,545,890 6,577,109 6,594,159 6,731,520 6,894,468 6,896,526 6,927,987 7,050,309 7,072,190 7,085,146 7,119,524 7,269,034 7,272,021 7,272,023 warranty synqor offers a t wo (2 ) year limited warranty. complete warranty information is listed on our website or is available upon request from synqor. information furnished by synqor is believed to be accurate and reliable. however, no responsibility is assumed by synqor for its use, nor for any infringements of patents or other rights of third parties which may result from its use. no license is granted by implication or otherwise under any patent or patent rights of synqor. product family package size performance level thermal design output current 6/6 rohs options (see ordering information) input voltage output voltage contact synqor for further information: phone : 978-849-0600 toll free : 888-567-9596 fax : 978-849-0602 e-mail : power@synqor.com web: www.synqor.com address : 155 swanson road boxborough, ma 01719 usa model number continuous input voltage output voltage maximum output current iq90018hp w 60nrs 34 - 160 v 1.8 v 60 a iq90033hp w 53nrs 34 - 160 v 3.3 v 53 a iq90050hp w 40nrs 34 - 160 v 5.0 v 40 a iq90120hp w 19nrs 34 - 160 v 12 v 19 a iq90150hp w 15nrs 34 - 160 v 15 v 15 a iq90240hp w 9fnrs 34 - 160 v 24 v 9.5 a iq90280hp w 08nrs 34 - 160 v 28 v 8.0 a iq90400hp w 5hnrs 34 - 160 v 40 v 5.7 a iq90480hp w 4gnrs 34 - 160 v 48 v 4.6 a i q 9 0 1 2 0 h p c 1 9 n r s - g options description: w x y z thermal design enable logic pin style feature set c - encased with threaded baseplate d - encased with non-threaded baseplate n - negative r - 0.180" s - standard


▲Up To Search▲   

 
Price & Availability of SYNQORINC-IQ90033HPC53NRS-G

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X