wire wound inductor - ceramic or ferrite ||||||||||||| | | aisc-0805(f) standard specifications: applications: features: 2 . 3 x 1 . 7 x 1 . 6 m m pb rohs compliant p arameters abracon p/n: aisc-0805(f)-xxx operating temperature: -40c to +85c storage temperature: -10c to +40c 70% rh max. 303 3 2 e s p e ranz a , r a n c h o s a n t a m a r g a r i t a , c a l i f o r n i a 926 8 8 t e l 949-54 6 - 800 0 | f a x 949 - 546 - 800 1 | w w w . abr a c o n . c o m revised: 12.09.10 visit w w w . abracon. com for terms & conditions of sale ? widely applied in the vco, saw circuit for gsm, cdma communications ? used in hard disk, notebook computer and other electronic equipment ? ceramic or ferrite construction assures the utmost in the thermal stablity and high srf ? exceptionally high q compared to non-wirewound inductor, especially at high frequencies ? inductance values available from 2.2 nh to 68uh; tight tolera nce pa r t srf r d c i d c x a m x a m n i m e c n a r e l o t r e b m u n ( % ) ( m h z ) ( ) ( m a ) aisc-0805-r0022 0 0 6 1 . 0 0 0 0 6 > 0 2 , 0 1 aisc-0805-r0033 0 0 6 8 0 . 0 0 0 0 6 > 0 2 , 0 1 , 5 aisc-0805-r0068 0 0 6 1 1 . 0 0 0 0 5 0 2 , 0 1 , 5 aisc-0805-r0082 0 0 6 9 1 . 0 0 0 8 4 0 2 , 0 1 , 5 aisc-0805-r012 0 0 6 5 1 . 0 0 0 1 4 0 2 , 0 1 , 5 , 2 aisc-0805-r015 0 0 6 7 1 . 0 0 0 9 2 0 2 , 0 1 , 5 aisc-0805-r018 0 0 6 2 . 0 0 0 3 3 0 2 , 0 1 , 5 , 2 aisc-0805-r022 0 0 5 2 2 . 0 0 0 6 2 0 2 , 0 1 , 5 , 2 aisc-0805-r027 0 0 5 5 2 . 0 0 0 5 2 0 2 , 0 1 , 5 , 2 aisc-0805-r033 0 0 5 7 2 . 0 0 0 2 2 0 2 , 0 1 , 5 , 2 aisc-0805-r039 0 0 5 9 2 . 0 0 0 1 2 0 2 , 0 1 , 5 , 2 aisc-0805-r047 0 0 5 1 3 . 0 0 5 7 1 0 2 , 0 1 , 5 , 2 aisc-0805-r056 0 0 5 2 3 . 0 0 5 6 1 0 2 , 0 1 , 5 , 2 aisc-0805-r068 0 0 5 8 3 . 0 0 0 5 1 0 2 , 0 1 , 5 , 2 aisc-0805-r082 0 0 4 2 4 . 0 0 0 4 1 0 2 , 0 1 , 5 , 2 aisc-0805-r10 0 0 4 6 4 . 0 0 0 2 1 0 2 , 0 1 , 5 , 2 aisc-0805-r12 0 0 4 1 5 . 0 0 0 2 1 0 2 , 0 1 , 5 , 2 aisc-0805-r15 0 0 4 6 5 . 0 0 0 0 1 0 2 , 0 1 , 5 , 2 aisc-0805-r18 0 0 4 4 6 . 0 0 5 9 0 2 , 0 1 , 5 , 2 aisc-0805-r22 0 0 4 7 . 0 0 5 8 0 2 , 0 1 , 5 , 2 aisc-0805-r27 0 5 3 1 0 8 6 0 2 , 0 1 , 5 , 2 aisc-0805-r33 0 1 3 4 . 1 0 6 6 0 2 , 0 1 , 5 , 2 aisc-0805-r39 0 9 2 5 . 1 0 6 5 0 2 , 0 1 , 5 , 2 aisc-0805-r47 0 5 2 2 7 . 1 0 3 4 0 2 , 0 1 , 5 aisc-0805-r56 0 3 2 9 . 1 0 5 3 0 2 , 0 1 , 5 aisc-0805-r68 0 9 1 5 0 . 2 0 0 3 0 2 , 0 1 , 5 aisc-0805-r75 0 8 1 1 . 2 0 8 2 0 2 , 0 1 , 5 aisc-0805-r82 0 8 1 3 . 2 0 5 2 0 2 , 0 1 , 5 aisc-0805-r91 0 6 1 4 . 2 0 3 2 0 2 , 0 1 , 5 aisc-0805-1r0 0 5 1 5 . 2 0 0 2 0 2 , 0 1 , 5 aisc-0805f-1r0 5,10,20 6 3 1.2 0 245 aisc-0805f-1r5 5,10,20 6 0 1.4 5 225 aisc-0805f-2r2 5,10,20 5 8 1.8 0 200 aisc-0805f-3r3 5,10,20 5 0 2.3 0 175 aisc-0805f-4r7 5,10,20 4 3 2.8 0 140 aisc-0805f-6r8 5,10,20 3 6 3.4 0 115 aisc-0805f-100 5,10,20 3 0 4.7 0 98 aisc-0805f-150 5,10,20 2 3 6.5 0 80 aisc-0805f-220 5,10,20 2 0 8.0 0 68 aisc-0805f-330 5,10,20 1 7 10.7 0 60 aisc-0805f-470 5,10,20 1 4 13.8 0 55 aisc-0805f-680 5,10,20 1 1 17.5 0 49 50 @ 500 mhz l (n h ) @ t est freq. 15 @ 250 mhz 18 @ 250 mhz 10 @ 2.5 mhz @ t est freq. q, m in 40 @ 1500 mhz 30 @ 1500 mhz 50 @ 1000 mhz 50 @ 1000 mhz 50 @ 500 mhz 50 @ 500 mhz 15 @ 7.9 mhz 10 @ 2.5 mhz 10 @ 2.5 mhz 15 @ 7.9 mhz 15 @ 7.9 mhz 15 @ 7.9 mhz 15 @ 7.9 mhz 23 @ 50 mhz 22 @ 50 mhz 20 @ 50 mhz 15 @ 7.9 mhz 33 @ 100 mhz 23 @ 50 mhz 23 @ 50 mhz 23 @ 50 mhz 45 @ 250 mhz 40 @ 250 mhz 40 @ 250 mhz 35 @ 250 mhz 60 @ 500mhz 50 @ 250 mhz 50 @ 250 mhz 50 @ 250 mhz 60 @ 500mhz 60 @ 500mhz 60 @ 500mhz 60 @ 500mhz 55 @ 500 mhz 60 @ 500 mhz 60 @ 500mhz 60 @ 500mhz 750 @ 25 mhz 820 @ 25 mhz 910 @ 25 mhz 1000 @ 25 mhz 390 @ 100 mhz 470 @ 50 mhz 560 @ 25 mhz 680 @ 25 mhz 180 @ 100 mhz 220 @ 100 mhz 270 @ 100 mhz 330 @ 100 mhz 33 @ 250 mhz 39 @ 250 mhz 47 @ 200 mhz 56 @ 200 mhz 68 @ 200 mhz 82 @ 150 mhz 100 @ 150 mhz 120 @ 150 mhz 2.2 @ 250 mhz 3.3 @ 250 mhz 6.8 @ 250 mhz 8.2 @ 250 mhz 12 @ 250 mhz 22 @ 250 mhz 27 @ 250 mhz 150 @ 100 mhz 1000 @ 7.9 mhz 1500 @ 7.9 mhz 10000 @ 2.5 mhz 22000 @ 2.5 mhz 15000 @ 2.5 mhz 2200 @ 7.9 mhz 3300 @ 7.9 mhz 4700 @ 7.9 mhz 6800 @ 7.9 mhz 33000 @ 2.5 mhz 47000 @ 2.5 mhz 68000 @ 2.5 mhz 10 @ 2.5 mhz 10 @ 2.5 mhz 8 @ 2.5 mhz cer tified abracon is cer tified abracon is iso9001:2008 cer tified
|||||||||||| | | | 2 . 3 x 1 . 7 x 1 . 6 m m pb rohs compliant options and part identification: (left blank if standard) t tape & reel j 5% g 2% k 10% m 20% tolerance code aisc - 0805(f) - - - please refer to the table above. g n i g a k c a p e d o c e c n a t c u d n i electrical properties for a isc-0805: c i t s i r e t c a r a h c e r u t a r e p m e t y c n e u q e r f s v q y c n e u q e r f s v l y c n e u q e r f s v q y c n e u q e r f s v l t e m perature chara c teri s tic blan k cera m i c f f err i t e m aterial code electrical properties for a isc-0805f electrical properties: wire wound inductor - ceramic or ferrite aisc-0805(f) 3 0 3 3 2 e s p e ran z a , r a n c h o s a n t a m a r g a r i t a , c a l i f o r n i a 9 2 6 8 8 t e l 949- 5 4 6 - 8 0 0 0 | f a x 9 4 9 - 5 4 6 - 8 0 0 1 | w w w . a b r a c o n . c o m revised: 12.09.10 visit w w w . abra c o n . c o m for terms & conditions of sale cer tified abracon is cer tified abracon is iso9001:2008 cer tified
|||||||||||||| | 2 . 3 x 1 . 7 x 1 . 6 m m pb rohs compliant 8 outline drawing: tape & reel: tape and reel 2,000pcs/reel dimensions: inches (mm) dimensions: mm z a c dimensions of tape dimensions of reel a c z 178 2.0 8.4+1.5 601.0 s eries aisc-0805(f) a m m b ( m m ) k m m p m m w m m pc s / r eel 1.8 2.5 1.45 4 8 2,000 a bra con p/n aisc-0805(f) wire wound inductor - ceramic or ferrite aisc-0805(f) 3 0 3 3 2 e s p e ran z a , r a n c h o s a n t a m a r g a r i t a , c a l i f o r n i a 9 2 6 8 8 t e l 949- 5 4 6 - 8 0 0 0 | f a x 9 4 9 - 5 4 6 - 8 0 0 1 | w w w . a b r a c o n . c o m revised: 12.09.10 visit w w w . abra c o n . c o m for terms & conditions of sale cer tified abracon is cer tified abracon is iso9001:2008 cer tified attention: abracon corporation?s products are cots ? commercial-off-the-shelf products; suitable for commercial, industrial and, where designated, automotive applications. abracon?s products are not specifically designed for military, aviation, aerospace, life-dependant medical applications or any application requiring high reliability where component failure could result in loss of life and/or property. for applications requiring high reliability and/or presenting an extreme operating environment, written consent and authorization from abracon corporation is required. please contact abracon corporation for more information.
|