revised: march 17, 2009 115 ? 2009 littelfuse, inc. specifications are subject to change without notice. surface mount fuses 202 series flat-pak ? fast-acting fuse > 202 series please refer to www.littelfuse.com/series/202.html for current information. 202 series 202 series fuse description fast-acting and slo-blo ? fuse versions of the flat-pak ? fuse designs are available. both designs are available in either a gull-wing surface mount package or a dip configuration for through-hole mounting. these fuse designs feature a 250 vac rating in a low profile, rectangular package. agency approvals electrical characteristics for series agency agency file number ampere range e10480 1/16ma - 5a lr29862 1/16ma - 5a % of ampere rating opening time 100% 4 hours, minimum 200% 2 seconds, maximum electrical specifications by item ampere rating (a) amp code max voltage rating (v) interrupting rating nominal cold resistance (ohms) nominal melting i 2 t (a 2 sec) agency approvals 0.062 .062 250 50 amperes @250 vac 7.9000 0.000220 x x 0.125 .125 250 2.4500 0.00180 x x 0.250 .250 250 0.8800 0.0147 x x 0.500 .500 250 0.2980 0.0363 x x 0.750 .750 250 0.1660 0.0980 x x 1.00 001. 250 0.1190 0.192 x x 1.50 01.5 250 0.0701 0.540 x x 2.00 002. 250 0.0469 1.07 x x 2.50 02.5 250 0.0455 1.76 x x 3.00 003. 250 0.0327 1.71 x x 4.00 004. 250 0.0244 3.00 x x 5.00 005. 250 0.0174 4.68 x x
revised: march 17, 2009 introduction to circuit protection introduction to circuit protection transientology 116 ? 2009 littelfuse, inc. specifications are subject to change without notice. surface mount fuses 202 series flat-pak ? fast-acting fuse > 202 series please refer to www.littelfuse.com/series/202.html for current information. average time current curves 100 10 0.1 0.01 0.001 1000 100 10 1 0.1 0.05 1/16a 1/8a 1/4a 1/2a 3/4a 1a 1 1/2a 2a 2 1/2a 3a 4a 5a time in seconds current in amperes 1 soldering parameters temperature rerating curve note: 1. derating depicted in this curve is in addition to the standard derating of 25% for continuous operation. wave soldering 260c, 3 seconds max. reflow soldering 215c, 30 seconds max.
revised: march 17, 2009 117 ? 2009 littelfuse, inc. specifications are subject to change without notice. surface mount fuses 202 series flat-pak ? fast-acting fuse > 202 series please refer to www.littelfuse.com/series/202.html for current information. 202 series materials body: thermoplastic terminations: tin/lead plated copper solderability mil-std-202, method 208. product characteristics cleaning board washable in most common solvents. operating temperature C55 o c to 125 o c dimensions packaging packaging option packaging specification quantity quantity & packaging code surface mount fuses bulk C 100 hxg 24mm tape and reel eia rs-481-2 (iec 286, part 3) 500 urg through hole fuses antistatic magazine C 100 h 9.45 (.372") 6.35 (.250") 4.19 (.165") 0.53 (.021") 10.16 (.400") .135" 0.30 (.012") 6 o 202 flat- pak l f f 2a 250 v pat 4563666 dip configuration (thru-hole) mounting 9.45 (.372") 6.35 (.250") 4.19 (.165") 202g flat- pak l f f 2a 250 v pat 4563666 smf configuration ("gull wing" surface mount) 1.52 (.060") 0.08 (.003") 1.40 (.055") 15.24 (.600") 17.12 (.674) 4.06 (.160) 11.53 (.454) 2.79 (.110) recommended pad layout part numbering system 0202 002. hxg series amp code refer to amp code column of electrical characteristics table quantity code hxg = 100 urg = 500 0202 002. h series amp code refer to amp code column of electrical characteristics table quantity code h = 100 surface mount fuses: through hole fuses:
revised: march 17, 2009 introduction to circuit protection introduction to circuit protection transientology 118 ? 2009 littelfuse, inc. specifications are subject to change without notice.
|