Part Number Hot Search : 
2SD1395 T44KU V27MA1S DL4763A GLENAIR NE59333 HM53462 1N4559B
Product Description
Full Text Search
 

To Download CLSM-100S Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  operating temperature ................................................................................... -25? to +85? storage temperature .................................................................................... -40? to +100? package ....................................................................................... flame retardant plastic case, ul94v-0 isolation voltage ............................................................................................ 5kv/50hz/min. model CLSM-100S closed l oop hall effect electrical specifications CLSM-100S general information w eight 28 grams mounting ........................................................... designed to mount directly on pcb via through hole connection pins aperture size (mm)................................................................................................. 7 x 16 output reference ................................................. ............................................................................................................... to obtain a positi ve output on terminal m, input current must flow in the direction of the arrow (conventional flow) 3. due to continuous process improvement, all specifications are subject to change without notice. applications variable speed drives for motors welding equipment power supply equipment measure and control system over current protection protection of power semiconductors features ?noncontact measurement ?measures dc, ac and impulse currents ?very fast response and high accuracy ?high overload capacity notes: 1. busbar temperature should not exceed 100?. 2. the dynamic performance is the best when the busbar fills the aperture. description the model CLSM-100S is a closed loop hall effect current sensor that  accurately measures dc and ac currents and provides electrical isolation between the current carrying conductor and the output of the sensor. nominal current (i n ) ............................................................................................... 100 a current range .................................................................................................... 0 to 200 a nominal output current (i m ) ...................................................................................... 50 ma turns ratio .......................................................................................................... 2000 / 1 measuring resistance (r m ) .................................................................................. 0 to 100 overall accuracy at 25c .................................................................................. 0.5 % of in supply voltage (vdc)........................................................................................... 12 to 18 current consumption .................................................................................. 15 ma + output current accuracy- dynamic performance zero current offset at 25? ................................................................................ < 0.2ma offset current temperature drift (-25? to +85?) ................................................. < 0.3ma linearity ........................................................................................................ better than 0.1% response time ............................................................................................... better than 0.5s di / dt .......................................................................................................... better than 70a/s frequency range .............................................................................................. dc to 200khz (-3db) w 6 1 2 0 h a n g i n g m o s s r o a d ? o r l a n d o , f l o r i d a 3 2 8 0 7 ? w w w . f w b e l l . c o m phone (407) 678-6900 ? fax (407) 677-5765 ? toll free (800) 778-6117
mechanical dimensions model CLSM-100S all dimensions are in inches (millimeters) due to continuous process improvement, all specifications are subject to change without notice. note: bipolar dc supply -12 to -18v +12 to +18v gnd clsm - 100s - + r sense out v m connection schematic mechanical dimensions + - m + - m + - m (14. 5mm) (15mm) (16 mm) .237" (22.86 mm) (27.2mm) (36. 4mm) (5.08 mm) (6.55mm) .032x.024" (0.8 x0.6mm) .258" .571" .591" 1.43" .900" .276" .276" (7mm) .630" .200" im 1.07" (7mm) (6mm) 6 1 2 0 h a n g i n g m o s s r o a d ? o r l a n d o , f l o r i d a 3 2 8 0 7 ? w w w . f w b e l l . c o m phone (407) 678-6900 ? fax (407) 677-5765 ? toll free (800) 778-6117


▲Up To Search▲   

 
Price & Availability of CLSM-100S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X