  iec inlet flters fn 280 compact fltered power entry module approvals n rated currents up to 10a n single or dual-fuse holder n fuses ?5 x 20mm n 2-pole rocker switch n general purpose application n optional earth line choke (e type) typical applications the fn 280 power entry module combines an iec inlet, a mains filter with single or dual- fuse holder and a 2-pole rocker switch in a small form factor. choosing fn 280 product line brings you the rapid availability of a standard filter associated with the necessary safety acceptances. standard iec connector filters are a practical solution helping you to pass emi system approval in a short time. a wide selection on amperage ratings, fuse options, mounting possibilities and filters for medical applications are designed to offer you the desired solution. n high conducted attenuation performance, based on chokes with high saturation resistance and excellent thermal behavior. n rear/front or snap-in mounting. n single or dual-fuse holder. n 2-pole rocker switch. n custom-specific versions are available on request. n portable electrical and electronic equipment n consumer goods n edp and office equipment n single-phase power supplies, switch-mode power supplies n test and measurement equipment n medical equipment features and benefits technical specifications maximum continuous operating voltage: 250vac, 50/60hz operating frequency: 50 to 400hz rated currents: 1 to 10a @ 40c max. high potential test voltage: p C> e 2000vac for 2 sec (standard types) p C> e 2500vac for 2 sec (b types) p C> n 760vac for 2 sec protection category: ip40 according to iec 60529 temperature range (operation and storage): -25c to +85c (25/85/21) design corresponding to: ul 1283, csa 22.2 no. 8 1986, iec/en 60939 flammability corresponding to: ul 94v-2 or better mtbf @ 40c/230v (mil-hb-217f): 1,500,000 hours fuse holder: 1 or 2 fuses (?5 x 20mm) marking: max. 250v ~ (text is print. below fuse symbol) rocker switch description: function: 2-pole, dark not illuminated marking i - 0 electrical specifications: inrush current 82a 6,000 on-off operations according to ul 1054, tv 5 10,000 on-off operations according to enec mechanical life: 50,000 cycles switch ratings: usa (ul) and canada (c-ul): 10a, 125vac; 10a, 250vac; 1/3hp europe (enec): 10a (4a), 250vac* * value in () relates to the inductive current charge: cos g = 0.65 typical electrical schematic n e p line cx r 2xl1 2xcy load n e p e types standard types n e p line cx r 2xl1 2xcy load l2 n e p
> components > fn 280 * maximum leakage under normal operating conditions. note: if the neutral line is interrupted, worst case leakage could reach twice this level. ** filters are delivered without fuse. filter selection table fn 281-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 1 140 fn 281-2-06 2 (2.4) 373 2 220 2.2 1000 -06 1 140 fn 281-4-06 4 (4.8) 373 1 220 2.2 1000 -06 1 140 fn 281-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 1 140 fn 281-10-06 10 (11.6) 373 0.34 220 2.2 1000 -06 1 140 fn 282-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 2 90 fn 282-2-06 2 (2.4) 373 2 220 2.2 1000 -06 2 90 fn 282-4-06 4 (4.8) 373 1 220 2.2 1000 -06 2 90 fn 282-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 2 90 fn 282-10-06 10 (11.6) 373 0.34 220 2.2 1000 -06 2 140 fn 283-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 1 140 fn 283-2-06 2 (2.4) 373 2 220 2.2 1000 -06 1 140 fn 283-4-06 4 (4.8) 373 1 220 2.2 1000 -06 1 140 fn 283-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 1 140 fn 283-10-06 10 (11.6) 373 0.34 220 2.2 1000 -06 1 140 fn 284-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 2 90 fn 284-2-06 2 (2.4) 373 2 220 2.2 1000 -06 2 90 fn 284-4-06 4 (4.8) 373 1 220 2.2 1000 -06 2 90 fn 284-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 2 90 fn 284-10-06 10 (11.6) 373 0.34 220 2.2 1000 -06 2 140 fn 285-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 1 140 fn 285-2-06 2 (2.4) 373 2 220 2.2 1000 -06 1 140 fn 285-4-06 4 (4.8) 373 1 220 2.2 1000 -06 1 140 fn 285-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 1 140 fn 285-10-06 10 (11.6) 373 0.34 220 2.2 1000 -06 1 140 fn 286-1-06 1 (1.2) 373 7.5 220 2.2 1000 -06 2 90 fn 286-2-06 2 (2.4) 373 2 220 2.2 1000 -06 2 90 fn 286-4-06 4 (4.8) 373 1 220 2.2 1000 -06 2 90 fn 286-6-06 6 (7.2) 373 0.45 220 2.2 1000 -06 2 90 fn 286-10-06 10 (11.6) 373 0.34 220 2.2 1000 -06 2 140 fn 283e-1-06 1 (1.2) 373 7.5 0.4 220 2.2 1000 -06 1 140 fn 283e-2-06 2 (2.4) 373 2 0.4 220 2.2 1000 -06 1 140 fn 283e-4-06 4 (4.8) 373 1 0.4 220 2.2 1000 -06 1 140 fn 283e-6-06 6 (7.2) 373 0.45 0.4 220 2.2 1000 -06 1 140 fn 284e-1-06 1 (1.2) 373 7.5 0.4 220 2.2 1000 -06 2 90 fn 284e-2-06 2 (2.4) 373 2 0.4 220 2.2 1000 -06 2 90 fn 284e-4-06 4 (4.8) 373 1 0.4 220 2.2 1000 -06 2 90 fn 284e-6-06 6 (7.2) 373 0.45 0.4 220 2.2 1000 -06 2 90 fn 282b-1-06 1 (1.2) 2 7.5 220 1000 -06 2 90 fn 282b-2-06 2 (2.4) 2 2 220 1000 -06 2 90 fn 282b-4-06 4 (4.8) 2 1 220 1000 -06 2 90 fn 282b-6-06 6 (7.2) 2 0.45 220 1000 -06 2 90 fn 282b-10-06 10 (11.6) 2 0.34 220 1000 -06 2 140 fn 284b-1-06 1 (1.2) 2 7.5 220 1000 -06 2 90 fn 284b-2-06 2 (2.4) 2 2 220 1000 -06 2 90 fn 284b-4-06 4 (4.8) 2 1 220 1000 -06 2 90 fn 284b-6-06 6 (7.2) 2 0.45 220 1000 -06 2 90 fn 284b-10-06 10 (11.6) 2 0.34 220 1000 -06 2 140 fn 286b-1-06 1 (1.2) 2 7.5 220 1000 -06 2 90 fn 286b-2-06 2 (2.4) 2 2 220 1000 -06 2 90 fn 286b-4-06 4 (4.8) 2 1 220 1000 -06 2 90 fn 286b-6-06 6 (7.2) 2 0.45 220 1000 -06 2 90 fn 286b-10-06 10 (11.6) 2 0.34 220 1000 -06 2 140 filter rated current leakage current* inductance capacitance resistance output fuses** weight @ 40c (25c) @ 230vac/50hz l1 l2 cx cy r connections [a] [a] [mh] [mh] [nf] [nf] [k?] [qty] [g]
> components > fn 280 per cispr 17; a = 50/50 sym; b = 50/50 asym; c = 0.1/100 sym; d = 100/0.1 sym typical filter attenuation 1a types 2 to 6a types 10a types product selector fn 28xx-yy-zz 06: faston 6.3 x 0.8mm (spade/soldering) 1 to 10: rated current blank: standard version e: optional earth line choke b: medical version (with bleed resistor and without y2-capacitor) 1: flange mounting version top/bottom, single-fuse 2: flange mounting version top/bottom, dual-fuse 3: flange mounting version left/right, single-fuse 4: flange mounting version left/right, dual-fuse 5: snap-in version, single-fuse 6: snap-in version, dual-fuse for example: fn 281-6-06, fn 283b-04-06, fn 283e-1-06
> components > fn 280 your local partner: to find your local partner within schaffners global network, please go to www.schaffner.com february 2009 fn 281 fn 282 fn 283 fn 284 fn 285 fn 286 tolerances dimensions a 32 32 50 50 32 32 0.3 b 82 82 65 65 65 65 0.3 c 72 72 40 40 0.1 d 43.1 43.1 43.1 43.1 43.6 43.6 0.3 e 28.5 28.5 28.5 28.5 28.5 28.5 0.25 f 5.5 5.5 5.5 5.5 5 5 0.3 g 59.95 max. 59.95 max. 59.95 max. 59.95 max. 59.95 max. 59.95 max. h ?3.5 ?3.5 ?3.3 ?3.3 i 16.2 16.2 16.2 16.2 16.7 16.7 0.3 j 22.5 22.5 22.5 22.5 22.5 22.5 m r 2.5 r 2.5 r 2.5 r 2.5 r 2.5 r 2.5 n 60 60 60 60 61.5 +0.2/-0* 61.5 +0.2/-0* +0.5/-0 p 29 29 29 29 29 29 +0.5/-0 r m3 m3 m3 m3 s 90 90 90 90 * for a panel thickness between 0.8 and 3mm all dimensions in mm; 1 inch = 25.4mm tolerances according: iso 2768-m / en 22768-m mechanical data fn 281 / fn 282 fn 283 / fn 284 a b e h c s f d i 6.3 x 0.8 j u fn 285 / fn 286 panel cut out n m p c a b e h g s f d i 6.3 x 0.8 j u c a b e g s f d i 6.3 x 0.8 j u r n m p c r g


▲Up To Search▲   

 
Price & Availability of FN282B-10-06

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X