speci?cations which provide more details for the proper and safe use of the described product are available upon request. all speci?cations are subject to change without notice. power supplies cbg series dc to dc converters single/multi output, general-purpose features ? these dc to dc converters are entirely shielded by a metal case(except base). ? no external components needed. ? built-in short circuit protection and remote on-off functions. temperature and humidity ranges shapes and dimensions circuit diagrams single output type cbg-sf series 2-output type cbg-df series deratings derating is necessary when operating environment temperatures exceed 50c. terminal connections temperature range operating C10 to +70c[with derating over 50c] storage C20 to +85c humidity range 95(%)rh max. [maximum wet-bulb temperature:38c] 0.5 16max. 7.8max. * 3.5 28max. t=0.3 22.86 ( 2.19 ) ( 2.19 ) ( 2.69 ) 2.54 ( 5.23 ) 3 4 2 6 4 5 1 1 3 2 6- 0.64 0.1 ( diagonal 0.85 0.1 ) 17.78 0.4 15.24 0.4 3.5 0.5 3 0.5 terminal: 1, 3 terminal: 2, 4 1.5 3 weight: 8g dimensions in mm tolerance: 0.3 * including stand-off 0.5mm 1 6 3 2 5 4 n.c +vout vout off on +vin ?in vin r l 1 6 3 2 5 4 off on +vin vin vin r l1 common out vout +vout r l2 series cbg-sf cbg-df no.1 +vin +vin no.2 Cvin Cvin no.3 control control no.4 nc Cvout no.5 Cvout common out no.6 +vout +vout 0 20 30 40 50 60 70 80 ?0 10 100 120 80 60 40 0 20 output power ( % ) ambient temperature ( ? )
a333_cbg 980406 speci?cations which provide more details for the proper and safe use of the described product are available upon request. all speci?cations are subject to change without notice. power supplies cbg series dc to dc converters single/multi output, general-purpose electrical characteristics * 1 output voltage:input variation(minimum to maximum input voltage), load variation :0 to 100%, temperature variation:C10 to +70c . * 2 variation value per 1c . * 3 measurement frequency:50mhz * 4 input voltage:typical value, output current:maximum value * 5 2-output load variation condition:balanced load precautions ? ripple noise of the input applied voltage should be less than 1% peak-to-peak of the standard input voltage. ? parallel connection of outputs(to increase the converter output current) is not possible. ? since the converter is entirely shielded by a metal case, care should be taken to isolate the case from the surrounding components and wiring pattern. ? a fuse should be connected to the input with a current rating 3 to 8 times that of the rated(normal) input current. part no. input voltage edc(v) output voltage * 1 (v) output current (ma) output voltage stability(%) typ. output ripple noise voltage * 3 ep-p(mv) typ. max. efficiency * 4 (%)typ. input-output insulation input load temperature * 2 CBG-0505SF 4.5 to 6 55% 0 to 160 0.05 0.2 0.01 40 100 55 withstand voltage ac.500v 1min insulation resistance 50m w min. dc.500v cbg-0512sf 4.5 to 6 125% 0 to 66 0.05 0.2 0.02 30 120 60 cbg-0512df 4.5 to 6 128% (0 to 33) 2 0.05 2 * 5 0.02 30 120 60 cbg-0515sf 4.5 to 6 155% 0 to 52 0.05 0.2 0.02 30 150 60 cbg-0515df 4.5 to 6 158% (0 to 26) 2 0.05 2 * 5 0.02 30 150 60 cbg-1205sf 10 to 16 55% 0 to 160 0.05 0.2 0.01 40 100 65 cbg-1212sf 10 to 16 125% 0 to 66 0.05 0.2 0.02 30 120 70 cbg-1212df 10 to 16 125% (0 to 33) 2 0.05 2 * 5 0.02 30 120 70 cbg-1215sf 10 to 16 155% 0 to 52 0.05 0.2 0.02 30 150 70 cbg-1215df 10 to 16 155% (0 to 26) 2 0.05 2 * 5 0.02 30 150 70
|