324 10/02 applications electronic ballasts features long useful life high reliability small dimensions extensive field experience in standard electronic ballast applications construction charge-discharge proof, polar aluminum case with insulating sleeve negative pole connected to case axial leads, welded to ensure perfect electrical contact taping and packing bulk pallet package capacitors with d l 16 30 mm are also available taped on reel. for details on taping and packing, refer to page 342. standard 105 c b43697 axial-lead capacitors b43697
325 10/02 b43697 standard 105 c specifications and characteristics in brief rated voltage u r surge voltage u s 450 vdc 495 vdc rated capacitance c r capacitance tolerance 10 47 f 10/+ 30 % q leakage current i l (5 min, 20 c) self-inductance esl 1) useful life 450 vdc 420 vdc requirements: 105 c; u r ; i ~ r 85 c; u r ; i ~ max 85 c; u r ; i ~ r 40 c; u r ;1,85 i ~ r 40 c; u r ; 2,3 i ~ r > 4 000 h > 9 000 h > 20 000 h > 200 000 h > 11 500 h > 17 500 h > 58 000 h > 200 000 h ? c / c 30 % of initial value esr 3 times initial spec. limit i l initial specified limit failure percentage: 1 % failure rate: 20 fit ( 20 10 9 /h) (for definiton fit , refer to chapter quality , page 62) voltage endurance test 105 c; u r 3 000 h 5 000 h post test requirements: ? c/c 10 % of initial value esr 1,3 % times initial spec. limit i l initial specified limit vibration resistance to iec 60068-2-6, test fc: displacement amplitude 0,75 mm, frequency range 10 hz to 55 hz, acceleration max. 10 g , duration 3 2 h iec climatic category to iec 60068-1: 40/105/56 ( 40 c/+ 105 c/56 days damp heat test) detail specification sectional specification similar to cecc 30301-801 iec 60384-4 i l 0,3 a c r f ------- u r v ------- ? ? 0,7 4 a + diameter d 12 mm 14 mm 16 mm 18 mm length l approx. esl (nh) 25 mm 22 26 30 mm 21 24 29 34 39 mm 33 38 1) if optimum circuit design is used, the values are lower by 30 %.
326 10/02 b43697 standard 105 c dimensional drawings dimensions, weights and packing units d l mm d max l max mm wire w mm approx. weight g packing units (pieces) bulk reel pallet 12 30 12,5 30,5 0,8 5,1 600 450 288 14 30 14,5 30,5 0,8 6,8 400 350 200 16 30 16,5 30,5 0,8 8,9 350 250 180 18 30 18,5 30,5 1,0 11,1 300 160 18 39 18,5 40 1,0 14,7 250 160 kal0680-9 max max d 1,3+0,1 5 40 _ 40 5 _ max +1,5 max +4 +0,04 0,02 w _
327 10/02 b43697 standard 105 c case dimensions and ordering codes technical data u r vdc c r f case dim. d l mm ordering code bulk pallet package reel 450 10 12 30 b43697a5106q000 b43697a5106q007 b43697a5106q009 15 14 30 b43697a5156q000 B43697A5156Q007 b43697a5156q009 22 16 30 b43697a5226q000 b43697a5226q007 b43697a5226q009 33 18 30 b43697a5336q000 b43697a5336q007 47 18 39 b43697a5476q000 b43697a5476q007 c r 100 hz 20 c f esr typ 100 hz 20 c ? esr max 100 hz 20 c ? esr max 100 hz ? 25 c ? esr max 10 khz 20 c ? z max 100 khz 20 c ? i ~ max 10 khz 40 c a i ~ max 10 khz 85 c a i ~ r 10 khz 105 c a 450 vdc 10 7,5 11,0 300 4,4 4,3 1,20 0,95 0,50 15 4,8 7,6 170 3,0 2,9 1,55 1,20 0,65 22 3,2 5,2 120 2,0 1,9 2,05 1,60 0,85 33 2,1 3,5 95 1,4 1,3 2,45 1,90 1,00 47 1,5 2,6 70 1,0 0,9 3,40 2,65 1,40
328 10/02 b43697 standard 105 c useful life depending on ambient temperature t a under ripple current operating conditions at u r 1) useful life depending on ambient temperature t a under ripple current operating conditions at u op 1) u op = 420 v 1,5 a t 20 000 h 10 000 h 250 000 h 100 000 h 50 000 h 4 000 h 0 40 60 50 90 80 70 110 100 0,5 1,0 ? c 120 kal0550-g 2,0 2,5 3,0 b43697 r ~ ~ 1,5 a t 11 000 h 50 000 h 25 000 h 250 000 h 100 000 h 80 0 40 50 60 70 90 100 ? c 120 110 0,5 1,0 2,0 2,5 3,0 b43697 kal0551-p r ~ ~ 1) refer to page 40 for an explanation on how to interpret the useful life graphs.
329 10/02 b43697 standard 105 c frequency factor of permissible ripple current i ~ versus frequency f frequency characteristics of esr at different temperatures typical behavior equivalent series resistance esr versus frequency f at different temperatures typical behavior for 10 f/450 v impedance z versus frequency f at different temperatures typical behavior for 10 f/450 v 10 f kal0647-3 0 b43697 2 510 3 hz 10 4 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,2 ~ 10 khz f ~ 10 1 f kal0643-5 0 510 2 510 3 10 hz 4 b43697 60 ? c 20 ? c 25 ? c _ 85 ? c 5 10 15 20 25 esr 10 khz esr f 10 1 10 2 5 3 10 10 4 10 5 55hz f b43697 kal0642-w 5 10 1 _ 0 10 10 1 10 2 5 5 ? 10 3 25 ? c _ 20 ? c 60 ? c esr 10 1 10 2 5 3 10 10 4 10 5 55hz f b43697 kal0641-n 5 10 1 _ 0 10 10 1 10 2 5 5 ? z 10 3 60 ? c 20 ? c 85 ? c 25 ? c _
herausgegeben von epcos ag unternehmenskommunikation, postfach 80 17 09, 81617 mnchen, deutschland ++49 89 636 09, fax (0 89) 636-2 26 89 ? epcos ag 2002. vervielf?ltigung, ver?ffentlichung, verbreitung und verwertung dieser broschre und ihres inhalts ohne aus- drckliche genehmigung der epcos ag nicht gestattet. bestellungen unterliegen den vom zvei empfohlenen allgemeinen lieferbedingungen fr erzeugnisse und leistungen der elek- troindustrie, soweit nichts anderes vereinbart wird. diese broschre ersetzt die vorige ausgabe. fragen ber technik, preise und lieferm?glichkeiten rich ten sie bitte an den ihnen n?chstgelegenen vertrieb der epcos ag oder an unsere vertriebsgesellschaften im ausland. bauelemente k?nnen aufgrund technischer erfordernisse gefahrstoffe ent- halten. ausknfte darber bitten wir unter angabe des betreffenden typs ebenfalls ber die zust?ndige vertriebsgesellschaft ein - zuholen. published by epcos ag corporate communications, p.o. box 80 17 09, 81617 munich, germany ++49 89 636 09, fax (0 89) 636-2 26 89 ? epcos ag 2002. reproduction, publication and dissemination of this brochure and the information contained therein without epcos? prior express consent is prohibited. purchase orders are subject to the general conditions for the s upply of products and services of the electrical and electronics industry recommended by the zvei (german electrical and el ectronic manufacturers? associ ation), unless otherwise agreed. this brochure replaces the previous edition. for questions on technology, prices and delivery please contact the sales offices of epcos ag or the international representa- tives. due to technical requirements components may contain dangerous substances. for information on the type in question please also contact one of our sales offices.
|