  data sheet paperless recorder phr this is a paperless recorder that displays measured data on the lcd in real time and stores data in compactflash. the type of input such as thermocouple, resistance bulb, d.c. voltage (current), etc. can be arbitrarily set to 18 channels at the maximum. the data stored in compactflash can be regenerated on the screen, and the use of supplied support software al - lows the data to be regenerated on a pc screen. the data recorded in ascii format can be directly read in a spreadsheet such as excel, which facilitates the process - ing on a pc. (the data recorded in binary format cannot be read in.) features 1. large capacity storage by compactflash measured data is periodically stored in compactflash. in case of 512 mb, for example, display fles for about 3 year and a half (display refresh cycle 30 sec) can be taken up (in case of ascii data format, 9 channels, maxi - mum/minimum recording). 2. quick search and display of past data data stored in compactflash can be displayed in suc - cession by scrolling the screen. 3. various display capability depending on the object of measurement, the most suitable display format can be selected from a variety of formats including bar graph display, trend display, digital display, etc. 4. pc support software supplied as standard loader software that enables easy display and change of set data and data viewer software that regenerates the data stored in compactflash are supplied as standard. 5. compact size 160 (w) 144 (h) 185 (d) mm(panel mounting), com - pact and as light as about 1.5 kg (9-point input, without option). 6. 18-point recording (option) 12 types of thermocouples, 2 types of resistance bulbs and dc voltage/current input can be recorded up to 18 points 7. communication function (option) rs485 modbus communication is available. 8. lcd extinguishing function automatically extinguishes the lcd if nothing is oper - ated for certain time. you can set the time after a lapse of which the lcd is extinguished via parameter "lcd ex - tinguishing time". the settable range is 0 to 60 minutes. setting at 0 minute overrides the function, whereby the lcd will never extinguish. this function prevents the backlight life from shorten - ing uselessly. during the extinguishment, the power consumption can be reduced. 9. ethernet function (option) ftp, web server, e-mail and modbus-tcp are available using 10base-t. specifications input system number of input points:9 points or 18 points (can be selected at the time of purchase) input circuit: input mutual isolation (see "others" on page 5 for the withstand voltage) resistance bulb measured current: about. 1 ma measuring cycles:9 or 18 points.100ms cycles recording cycle: 1 second to 12 hours input types: thermocouple, resistance bulb, dc volt - age, and dc current (shunt resistors are ftted in input terminals). note) provide a shunt resistor (type: phzp0101) separately. measuring range date EDS10-74J dec. 5, 2011 input types reference range thermocouple b r s k e j t n w l u pn 400.0 to 1760.0oc 0.0 to 1760.0oc 0.0 to 1760.0oc C200.0 to 1370.0oc C200.0 to 800.0oc C200.0 to 1100.0oc C200.0 to 400.0oc 0.0 to 1300.0oc 0.0 to 1760.0oc C200.0 to 900.0oc C200.0 to 400.0oc 0.0 to 1300.0oc resistance bulb jpt100 pt100 C200.0 to 600.0oc C200.0 to 600.0oc dc voltage 50mv 500mv 1-5v 0-5v 0.00 to 50.00mv 0.0 to 500.0mv 1.000 to 5.000v 0.000 to 5.000v note) b, r, s, k, e, j, t : jis c 1602, din iec 584-1 n : nicosil-nisil (iec 584) w : 5%re-26%re w (hoskins mfg. co. usa) l : fe-cu ni (din 43710) u : cu-cu ni (din 43710) pn: platinel jpt100 : jis c 1604- 1989 (old jis pt 100) pt100 : jis c 1604, din iec 751
2 phr selection of input types: by key operation on the front panel. note that the same input type (thermo - couple, resistance bulb, voltage) should be set every 2 channels. refer to "set - ting method of input types" for details. burn-out function: provided as standard for thermocouple and resistance bulb inputs. if the input has been open-circuited, the recording level swings over 100%. thermocouple burn-out current: approx. 0.2 a input flter function: settable for each channel (primary delay flter) time constants are settable in the range from 0 to 900 sec. scaling function: possible by dc voltage (current) input scaling range: -32767 to 32767 decimal position: settable at any point unit symbol: selectable out of 125 different units or 12 user units of up to 7 charac - ters. subtraction function: subtraction between each channel is al - lowed. totalizing function: the measured value of each channel can be totalized. applicable to daily, monthly, annual or external input total - izing. f value calculation function: f value (extinction value of bacteria by sterilization by heating) can be calcu - lated from the measured temperature by each channel. f value and measured temperature can be displayed and recorded using 2 chan - nels. square rooter function: square rooter can be performed against the input value per each channel. logarithmic calculation function: the measured value of each channel can be displayed in exponent form. mathematics function: the following calculation is available with the math function. 1) computation function addition, subtraction, multiplication, division, absolute value, exponential, square-root extraction, log, ln, exp, humidity, maximum, minimum, average, and integration. 2) computation input enable channel input (1 to 30 ch), total input (1 to 30 ch), di (di to di10), communi - cation input (no.1 to no.12), constant (no.1 to no.20). indication system indicator: 5.7" tft color lcd (320 240 dots) with backlight, no contrast adjustment. on the lcd, certain picture elements remain lit or extinguished. on account o f t h e n a tu r e i n h e r e n t t o l c d, t h e brightness may be non-uniform. but, such are not troubles. color of indication: 14 colors applicable language: english, japanese life of backlight: 50,000 hours (20c) in terms of total lighting time. (replace the backlight as a set of dis - play unit. if the lcd extinguishing func - tion is resorted to, the lcd can be used longer as much.) trend display: direction: vertical and horizontal number of channels: 10 or 4 channels per screen group. (select from up to 30 channels). display refreshment cycles: select from 1 second to 12 hours scale display or no-display can be se - lected. bar graph display: number of channels: 10 or 4 channels per screen group. (select from up to 30 channels). display refreshment cycles: 1 second. analog meter display: for 4 inputs per screen group. (input from 1 to 4). display in bar graphs or in analog meters can be selected. display refresh cycle: 1 second digital display: number of channels: 10 or 4 channels per screen group. (select from up to 30 channels). display refreshment cycles: 1 second. totalizing data display: number of channels: 10 or 4 channels per screen group. (select from up to 30 channels) display refresh cycle: 1 second. event summary display: alarm summary and message summary can be displayed. the message occur - rence information and message display can be switched. ethernet log display: e-mail sending, ftp server log in/off and modbus tcp/ip communication start/stop can be displayed. parameter display/set: already-set data display and set change display screen tag indication: number of characters to be displayed: up to 8 characters up to 8 characters (note 1) at 10-channel display. u p t o 16 ch a r a c t e r s a t 4 channel display. note 1: up to 7 characters only can be displayed on certain screens.
3 characters to be displayed: alphanumerics, hiraganas and katakanas. tag, unit and channel no. display: which can be displayed depends on the particular screen. refer to the table below. (keywords only are extract - ed.) screen channnels per screen item tag 1 tag 2 unit ch np. trend bar graph analog meter instantaneous value 4 or less 5 or more 4 or less 5 or more 4 or less 5 or more 4 or less 5 or more + x + x x all all + C + C C + x + x x + x + x x: 1 item only can be displayed +: 2 items only can be displayed C: nothing can be displayed all except tag 2 all except tag 2 no. 1 to 4 others historical trend display: displays past recording data read from compact fash, currently recording data or just recorded data. the record - ing chart can be scrolled or, via time designation, the control can jump to an arbitrary recording chart. number of screen groups: four groups (up to 10 channels per 1 group can be registered.) keyboard no. of keys: 8 function: use to select various screens and set various parameters. recording function external memory media: compact flash card format according to fat32, fat16 or fat. otherwise, reading and saving are impossible. recording capacity: 2gb maximum (compact fash). lim - iting the recording fle to 64 mb is recommended (for 112 hours if display refresh cycle is 1 second. see table 1 (p. 7).) (when the size of the recording fle comes to be 256mb or more, a new fle is created automatically and recording is maintained.) * please change the compact fash every six month to prevent the data los - ing. recording method: turning on the rec key allows mea - sured data to be written at fxed cycles. recorded as a new fle whenever the recording starts. data save cycles: linked to the display refreshment cycles on the real time trend screen. how - ever, they are automatically set to about 1 minute if the refreshment cycles are set to less than 1 minute. trend data: measurement data sampled at mea - surement cycle is saved in terms of mean value, inst ant aneous value or maximum/minimum value. event data: saves alarm data and message data. further saves power on and off, if any, after starting recording. totalizing value data: records the totalized data according to the totalizing type selected by channels. values by totalizing types or total from the beginning of totalizing, whichever selected, can be recorded. for each channel, the input value totalizing, number of di inputs or measurement at times when di inputs have occurred can be selected. input values to be totalized are selected from daily report, monthly report, yearly report and exter - nal input. if power has been turned off and on while totalizing, the totalizing is resumed at last value. (last value remains saved, but data during power off is not totalized.) confguration data: confguration data can be saved. and this data can also download to recorder. storage capacity : approximately 3 years when the display refresh cycle is 30 seconds (in case of 9-channel recording in ascii data for - mat, and 512 mb compact fash used). refer to table 1. residual capacity of memory: indicates how much of the memory card has been used on the screen. when all the memory is used up, you can stop recording or delete the oldest recording fle to save the newest data. compact fash card form: phzp1301, phzp2801 (cf card) (if a card other than the above is used, no operation assurance is ensured. meanwhile, as for other cf cards for which operation check will have been completed, the results will be posted on our company's homepage sequen - tially. please refer to this website.) data format: either of ascii or binary format can be selected. (switching cannot be made while the recording is in progress. in the case of ascii format, the data can be directly read on excel, etc.) note: the data recorded in binary for - mat cannot be read directly. approximately 166 bytes per sampling for maximum/minimum recording of 9-channel input in ascii format, or ap - proximately 40 bytes for maximum/mini - mum recording of 9-channel input in binary format.
4 phr alarm function no. of settings: up to 4 alarms for each channel are set - table. type of alarm: high/low limits indication: status (alarm types) is displayed on digi - tal display unit when an alarm occurs. historical display on alarm summary (alarm start/cancel time and alarm types) hysteresis: set within the recording range of 0 to 100% acts on high or low limit alarm, and does not affect the battery alarm nor memory full alarm. relay output: number of points; 10 (option: cannot be selected if the number of input points is 18.) transistor output (open collector output): 18 points (option) alarm latch function: holds alarm indication and alarm output even after measurement value has left the alarm range. on/off operation is performed accord - ing to key setting. power supply rated power voltage: 100 to 240v ac range of operating voltage: 90 to 264v ac supply frequency: 50/60hz 2% (both employable) power consumption power voltage 100v ac 240v ac consumption about 36va about 47va structure mounting method: panel-mounted (vertical panel) or por - table (desktop type) thickness of panel: 2 to 26 mm materials: pc-abs for case and bezel color: black external dimensions: panel-mounted: 160 (w) 144 (h) 185 (d) mm portable: 160 (w) 171.5 (h) 206.6 (d) mm mass: about 1.5 kg (9-point input, without op - tion) external terminal board: screw terminals (m3 thread) rj45: ethernet terminal (option) operating condition ambient temperature: panel-mounted(without ethernet func - tion): 0 to 50c * 1 portable: 0 to 40c panel mount (with ethernet function): 0 to 40c * 2 ambient humidity: 20 to 80%rh vibration: 10 to 60hz 0.2m/s 2 or less shock: none magnetic feld: 400 a/m or less signal source resistance: thermocouple input .... 1kohm or less resistance bulb input... 10ohm/wire or less (resistance of each wire of 3-wire system should be balanced). voltage input... 0.1% or less of input resistance mounting posture: forward tilt 0o, backward tilt within 30o, horizontal 0o warm-up time: one hour or more after power on environmental protection: iec ip50 (front)/20 (terminal) installation category: ii pollution degree: 2 operating altitude: 2000m max. *1: in case of the 12th digit of ordering code is "y" or "r". *2: in case of the 12th digit of ordering code is "e" or "w". reference standard accuracy/resolution: measuring conditions (232oc, 65 10% rh, power voltage, frequency fuctuation within 1%, no external noise, warm-up time of 1 hour or more, vertical mounting, standard values of signal source resistance and wiring resistance... within 1% ) input types digital indication accuracy note 1 digital indication resolution thermocouple b r s k e j t n w l u pn (0.15%+1 digit) (0.3%+1 digit) for the range shown below thermocouple b : 400 to 600oc thermocouples r and s : 0 to 300oc thermocouples k, e, j, t, l and u : - 200 to - 100c resistance bulb jpt100 pt100 (0.15%+1 digit) dc voltage 50mv 500mv 5v (0.15%+1 digit) 0.1c 10v 100v 1mv note 1) digital indication accuracy is a percentage (%) with respect to input range of 1 page. note 2) no error of reference contact compensation of thermocouple is included. 0.1c error of reference contact compensation: k, e, j, t, n, l, u, pn: 0.5oc r, s, b, w: 1.0oc (when measured at 0oc or more) max. input voltage: thermocouple, resistance bulb, dc volt - age: 10v dc (continuous) input impedance: thermocouple, dc voltage: about 1m ?
5 others clock: with calendar function (christian era) accuracy: 100 ppm or less (monthly error: about 4 minutes) however, time error at ambient tem - perature 232oc and power on/off is not included. memory backup: parameters are saved to the internal non-volatile fash memory. the clock is backed up with built-in lithium battery. trend data is not backed up. insulation resistance: 100 ? or more (when measured be - tween each terminal and ground by using a 500v dc megger) withstand voltage: input terminal C input terminal: 500 v ac, 1 min power terminal C ground: 2000v ac, 1 min input terminal C ground:500v ac, 1 min alarm terminal (contact output) C ground: 2000 v ac, 1 min alarm terminal (contact output) C alarm terminal (contact output): 750 v ac, 1 min communication terminal C ground: 500 v ac, 1 min alarm terminal (open collector) C ground: 500 v ac, 1 min power terminal C input terminal: 500 v ac, 1 min effect on operation effect of power supply fuctuation conditions: for the fuctuation in the range from 90 to 264v ac (frequeucy: 50/60hz) reading change (100v ac base): (0.2%+1 digit) or lower. for the fuctuation in the range from 47 to 63hz (power voltage: 100v ac) reading change (50hz base): (0.2%+1 digit) or lower. effect of input signal resistance: thermocouple input: (0.5v/ ? )+1digit or less dc voltage: fluctuation for resistance value equivalent to 0.1% of the input resistance: (0.2%+1 digit) or lower. reistance bulb (for wiring resistance of 10 ? for 1 line (the same for 3 lines)) reading change: (0.2%+1 digit) or lower. effect of ambient temperature: reading change: (0.3%+1 digit)/10oc or lower. effect of mounting position: for the backward 30o slant reading change: (0.2%+1 digit) or lower. effect of vibration: when sine wave of 10 to 60hz with the acceleration of 0.2m/s 2 is applied in each direction for 2 hours. reading change: (0.2%+1 digit) or lower. effect of external noise: normal mode noise (50, 60hz0.1hz) 20db or more common mode noise (50, 60hz0.1hz) 120db or more (thermocouple input: minus terminal- ground) (resistance bulb input: b line-ground) safety and emc standard safety standard: based on iec61010-1 (portable type does not meet the stan - dard.) emc standard: based on en61326 transportation/storage conditions temperature: C10 to +60oc humidity: 5 to 90%rh vibration: 10 to 60hz, 2.45 m/s 2 or lower shock: 294m/s 2 or lower (packed state) additional function (option) alarm relay output/di (11th digit of code symbols: 1) a card with 10-point relay output and 5-point di in - put can be mounted. cannot be mounted if the number of input points is 18. terminal structure: m3 screw terminal alarm relay output: 1a contact output (10 points), individual channel or common output (or output) allowed. do1: contact capacity;150v/3a ac, 30v/3a dc (resistive load) do2-10: contact capacity; 240v/3a ac, 30v/3a dc (resistive load) di input: no-voltage contact input (5 points) the following control is allowed by con - tact input. (1) recording start/stop (2) message set (3) f value calculation reset (4) totalizing start/stop (5) totalized value reset (6) lcd (backlight) lighting (7) e-mail sending on pulse width: 200 msec or more off pulse width: 200 msec or more communication, alarm (open collector output), di input (12 digit of code symbols is r or w) rs485 communication. card having 18 alarm points (open collector output) and 5 di input points can be installed. terminal structure: m3 thread terminal (do11 (alarm open collector output), di6, dio source termi - nal and communication terminal) d-sub 25 pin female terminal (do12 to do28 (alarm open collector output)) and di7 to di10 communication: physical specifcations: eia rs485 communication protocol: modbus (rtu)
6 phr communication method: 2 wire method. half duplex bit serial, start-stop sync type. data type: 8 bits. parity: odd/even/none. stop bit: 1 bit. communication rate: 9600, 19200bps connection aspect: multi-drop/up to 32 recorders con - nectable including master station communication distance: total extension 500m or less rs232c/rs485 signal converter (recom - mendation): isolated type manufacture: omron corporation model: k3sc-10 alarm output: open-collector transistor output (18 points) electrical rate: 30vdc, 100ma (resistive load) di input: no-voltage contact input (5 points). contact input allows following controls. (1) recording start/stop (2) message set (3) f value calculation reset (4) totalizing start/stop (5) totalized value reset (6) lcd (backlight) lighting (7) e-mail sending on pulse width: 200 msec or more off pulse width: 200 msec or more ethernet (option) the following can be performed through the ethernet function. http server (internet explorer 6 is available) note 1 measurement display: digitally displays the measurement of each channel of the recorder and alarm occurrence status. event summary display: displays event summary including alarm on/off and issuance of messages. main unit information display: displays memory use conditions and in - formation on the main unit such as the battery end warning. integrated value display: digitally displays the integrated value of each channel of the recorder. ftp server (internet explorer 6 available.) note 1 file download: record fles stored in compact fash (cf) can be downloaded from the browser. file delete: record fles stored in cf can be deleted from the browser. access authentication: authenticates access authority to ftp server. smtp (e-mail client) transmits e-mails to specified address under the following conditions. (1) when an alarm turns on or off (2) when di is set to on or off (3) when an error occurs to the main u n i t ( s u ch a s l ow b a tt e r y o r n o memory space) (4) at specifed intervals modbus tc/ip data read: settings can be read through modbus tcp/ip communication. data write: settings can be written through mod - bus tcp/ip communication. note1: netscape is not available. support software note: applicable pc: pc/at-compatible machine operation on pc98-series machines by nec is not guar - anteed. operation on self-made or shop-brand pcs is not guar - anteed. the following software is provided as standard. loader software for pc major function: performs various parameter setting/ change of the main unit o/s: windows 2000/xp required memory: 64mb or larger disk drive: windows 2000/xp-capable cd-rom hard disk capacity: free capacity of 30mb or larger required printer: windows 2000/xp-capable printer and printer driver note) pc loader communication cable (type phzp1801) is separately required. data viewer software major function: regenerates the past trend record on the pc from the data in the compact fash. provided with historical trend dis - play and event display functions. data can be changed to csv fle. o/s: windows 2000/xp required memory: 64mb or larger disk drive: w indows 20 0 0/xp-capable cd-rom drive hard disk drive: free capacit y of 30mb or larger re - quired printer: windows 2000/xp-capable printer and printer driver standard functions function record range voluntary setting input type setting skip function trend display tag name display screen name display unit creation scaling function pv shift input filter burnout function historical trend display description recording range can be set by channel. input type can be set by channel. (key operation on the front face) set the same input type for every 2 channels. skips arbitrary channel display/recording. time display: time is displayed at the top of the trend display screen. alarm display: on occurrence of an alarm and the restoration, alarm is displayed in the alarm display field. the compact flash usage is displayed with a bargraph at the top. by channel, maximum of 8 characters. displays the screen name (maximum of 16 characters). industrial units can be arbitrarily created, maximum of 7 digits, 12 types. arbitrary scaling is allowed in the case of dc voltage input. decimal point position can also be arbitrarily set in the range from -32767 to 32767. shift the zero point and slant of the reading. prevents sudden fluctuation of input for each channel (primary delay filter). time constant: 0 to 900 seconds. displays the break of thermocouple/resistance bulb input by scaling out to 100% side. regenerates and displays the data stored in the compact flash by scrolling the screen. displays data of a designated time.
7 table 1. recording capacity the recording can be made for the period of time listed in the tables shown below under the following conditions. ? 9 input points ? recording data format: ascii ? recording type: maximum/minimum recording ? no alarm, nor message, nor other events. display upgrade cycle compactflash size 64mb 1 sec 10 sec 30 sec 1 min 10 min recordable capacity (about) 112 hours 46 days 140 days 280 days 7.7 years display upgrade cycle compactflash size 256mb 1 sec 10 sec 30 sec 1 min recordable capacity(about) 18 days 187 days 1.5 years 3 years ? when the number of input points is 18, the period is ap - proximately one half of those listed in the table. ? in binary format, the period is approximately 4 times as long as those listed in the table. ? for recording type of mean or instantaneous value, the number of days is approximately 2 times as long. while compact flash is not in use, recorded date and event date can be stored approximately 600kb in the main unit when recording 9-channel in max-min recording, ap - proximately 15300 data can be stored. for 4 hours at the display refresh cycle of 1 second. the number of the save data varies depending on the number of the event data. ordering code specifications 4 5 6 7 8 phr 4 5 6 7 8 9 10 11 12 13 1 2 4 1 y 1 b - 1 2 n e 0 1 9 channel 18 channel panel mounting portable (desktop) black without (not furnished) version no. japanese english 100 to 240 v ac without with without communication (rs485), alarm output, di input ethernet ethernet, communication (rs485), alarm output, di input general 9 10 11 12 13 digit note 3 note 2 note 1 note 4 note 5 note 4,5 note note 1 : cannot be selected if 2 is selected for the forth digit (the number of input points is 18). note 2 : the compact flash is optional. refer to the section of "optional items" below. note 3 : portable mounting type doesn't comply with ul and ce. note 4 : alarm output; transistor (open collector) output note 5 : cannot be specified when "2" is selected for the 5th digit. b 1 4 1 y r e w y scope of deliviry recorder (phr) item panel mounting bracket cd-rom pc support software instruction manual 1 1 panel packing for the front face ac power cord (2m) 1 1 quantity portable panel mounting 2 1 1 noise filter for the power supply 1 1 optional items pc card adapter phzp0501 for compact flash compact flash phzp2801-512 phzp1301-01g 512mb 1gb phzp1001 item code specification shunt resistor for dc current input phzp0101 10 0.1% pc loader communication cable phzp1801 length 3m with connector usb-a/usb minib terminal * cd-rom with instruction manual and support software phzp0301 terminating resistor for communication phzp0701 100 transmission cable phzp0901 for phr to pc for phr to phr d-sub light type 25 pin connector with male terminal for alarm output (without cable) phzp0801 * shape of this cable is shown below usb (a) plug C usb (mini-b ) plug
8 phr outline diagrams (unit : mm) p anel cutout panel mounting type in the case of 9-point input in the case of 18-point input 144 161 136.5 160 140 185 136.5 21.6 t 2 t 26 panel mtg.bracket 24.6 when panel packing is mounted (note) when placing the main unit on another instrument or on the floor, allow a space of 100mm or more between the unit and instrument or the floor. input terminal (points 1 to 9) source terminal 100 240vac n l r-module rcj fuji electric di input & alarm terminal (option) communication dio terminal (option) dio-on trx1 trx2 shld do11 dio - com 24vdc in a6 dio terminal (d-sub) (option) ethernet terminal (option) 144 161 136.5 160 140 185 136.5 21.6 t 2 t 26 panel mtg.bracket 24.6 when panel packing is mounted (note) when placing the main unit on another instrument or on the floor, allow a space of 100mm or more between the unit and instrument or the floor. r-module fuji electric rcj fuji electric rcj r-module 100 240vac l n input terminal (points 10 to 18) source terminal dio-on trx1 trx2 shld do11 dio - com 24vdc in a6 dio terminal (d-sub) communication dio terminal input terminal (points 1 to 9) ethernet terminal (option) 137 +1.5 0 (160 n?22) +2 0 137 +1.5 0 137 +1.5 0 mounting one unit mounting close together sidewise n : number of units to be mounted do not use the water proof pacing in case of mounting n unit
9 portable (table top) type in the case of 9-point input in the case of 18-point input r-module rcj fuji electric 144 49 208.5 136.5 15 20 160 140 185 136.5 21.6 foot handle stand-foot (note) please use the stand-foot upright. di input & alarm terminal (option) input terminal (points 1 to 9) source terminal communication dio terminal (option) dio terminal (d-sub) (option) dio-on trx1 trx2 shld do11 dio - com 24vdc in a6 r-module rcj fuji electric r-module rcj fuji electric 144 208.5 136.5 15 20 160 140 185 136.5 21.6 foot handle (note) please use the stand-foot upright. input terminal (points 10 to 18) source terminal 49 dio-on trx1 trx2 shld do11 dio - com 24vdc in a6 stand-foot input terminal (points 1 to 9) communication dio terminal (option) dio terminal (d-sub) (option)
10 phr external connection diagrams panel mounting type in the case of 9-point input in the case of 18-point input di1 231 di2 di3 di4 di5 do1 do2 do3 do4 do5 do6 do7 do8 do9 do10 alarm output/digital input terminal m3 thread ch6 ch7 rcj ch8 ch9 resistance bulb thermo- couple voltage (note) for current input, connect an optional shunt resistance to a voltage input terminal + - + - ch1 ch2 ch3 ch4 ch5 resistance bulb thermo- couple voltage ac100 240v 50/60hz + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - 232 233 234 235 236 237 238 239 240 241 242 243 244 245 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 61 11 62 12 63 13 71 21 72 22 73 23 31 32 33 81 41 82 42 83 43 91 51 92 52 93 53 communication, digital input and alarm (open collector) output terminal (m3 thread) dio(+24v) dio(0v) do11 di6 shld trx2 trx1 pcd 6 25 13 14 vpd 1 do12 7 do13 8 do14 9 do15 10 do16 11 do17 12 do18 15 do19 16 do20 17 do21 18 do22 19 do23 20 do24 21 do25 22 do26 23 do27 24 do28 2 di7 3 di8 4 di9 5 di10 pcd vpd vpd pcd pcd pcd + C 24vdc modbus communication (shield) (C) (+) digital input and alarm (open collector) output terminal, d-sub terminal m3 thread input terminal m3 thread source terminal ch6 ch7 rcj ch8 ch9 (note) for current input, connect an optional shunt resistance to a voltage input terminal + - + - ch1 ch2 ch3 ch4 ch5 - - + - + - + - + - + - + - + - + - + - + - + - + - + - + - 61 11 62 12 63 13 71 21 72 22 73 23 31 32 33 81 41 82 42 83 43 91 51 92 52 93 53 ch15 ch16 rcj ch17 ch18 + - + - ch10 ch11 ch12 ch13 ch14 + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - 161 111 162 112 163 113 171 121 172 122 173 123 131 132 133 181 141 182 142 183 143 191 151 192 152 193 153 dio(+24v) dio(0v) do11 di6 shld trx2 trx1 pcd 6 25 13 14 vpd 1 do12 7 do13 8 do14 9 do15 10 do16 11 do17 12 do18 15 do19 16 do20 17 do21 18 do22 19 do23 20 do24 21 do25 22 do26 23 do27 24 do28 2 di7 3 di8 4 di9 5 di10 pcd vpd vpd pcd pcd pcd + C 24vdc modbus communication (shield) (C) (+) m3 thread input terminal ac100 240v 50/60hz m3 thread source terminal communication, digital input and alarm (open collector) output terminal (m3 thread) digital input and alarm (open collector) output terminal, d-sub terminal resistance bulb thermo- couple voltage resistance bulb thermo- couple voltage resistance bulb thermo- couple voltage resistance bulb thermo- couple voltage
11 portable (table top) type in the case of 9-point input in the case of 18-point input alarm output/digital input terminal m3 thread resistance bulb thermo- couple voltage resistance bulb thermo- couple voltage di1 231 di2 di3 di4 di5 do1 do2 do3 do4 do5 do6 do7 do8 do9 do10 ch6 ch7 rcj ch8 ch9 (note) for current input, connect an optional shunt resistance to a voltage input terminal + - + - ch1 ch2 ch3 ch4 ch5 ac100 240v 50/60hz l n + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - 232 233 234 235 236 237 238 239 240 241 242 243 244 245 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 61 11 62 12 63 13 71 21 72 22 73 23 31 32 33 81 41 82 42 83 43 91 51 92 52 93 53 dio(+24v) dio(0v) do11 di6 shld trx2 trx1 pcd 6 25 13 14 vpd 1 do12 7 do13 8 do14 9 do15 10 do16 11 do17 12 do18 15 do19 16 do20 17 do21 18 do22 19 do23 20 do24 21 do25 22 do26 23 do27 24 do28 2 di7 3 di8 4 di9 5 di10 pcd vpd vpd pcd pcd pcd + C 24vdc modbus communication (shield) (C) (+) communication, digital input and alarm (open collector) output terminal (m3 thread) digital input and alarm (open collector) output terminal, d-sub terminal m3 thread input terminal source terminal (inlet) voltage thermo- couple resistance bulb voltage thermo- couple resistance bulb voltage thermo- couple resistance bulb voltage thermo- couple resistance bulb ac100 240v 50/60hz l n ch6 ch7 rcj ch8 ch9 (note) for current input, connect an optional shunt resistance to a voltage input terminal + - + - ch1 ch2 ch3 ch4 ch5 + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - 61 11 62 12 63 13 71 21 72 22 73 23 31 32 33 81 41 82 42 83 43 91 51 92 52 93 53 ch15 ch16 rcj ch17 ch18 + - + - ch10 ch11 ch12 ch13 ch14 + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - 161 111 162 112 163 113 171 121 172 122 173 123 131 132 133 181 141 182 142 183 143 191 151 192 152 193 153 dio(+24v) dio(0v) do11 di6 shld trx2 trx1 pcd 6 25 13 14 vpd 1 do12 7 do13 8 do14 9 do15 10 do16 11 do17 12 do18 15 do19 16 do20 17 do21 18 do22 19 do23 20 do24 21 do25 22 do26 23 do27 24 do28 2 di7 3 di8 4 di9 5 di10 pcd vpd vpd pcd pcd pcd + C 24vdc modbus communication (shield) (C) (+) communication, digital input and alarm (open collector) output terminal (m3 thread) digital input and alarm (open collector) output terminal, d-sub terminal m3 thread input terminal source terminal (inlet)
phr note 1) windows2000/xp, excel, and internet explorer are the trademarks or registered trademarks of microsoft corpora - tion in the u.s. note 2) compactflash is a trademark or registered trademark of sandisk corporation. note 3) modbus is the trademark or registered trademark of aeg schneider automation international. note 4) the pc98 series is are the trademark or registered trademark of nec corporation. note 5) netscape is the trademark or registered trademark of netscape communications corp. s electing input type the input type is the same every 2 channels. the input type of channel 2, 4, 6, 8, 11, 13, 15 and 17 can only be set in the same category of previous channel. the following input types are available. example of channel input type selection details input type thermocouple, 50mv resistance bulb pt100, jpt100 k, e, j, t, r, s, b, n, w, l, u, and pn thermocouples, 50mv 500mv 500mv 5v 1 to 5v, 0 to 5v other channels other channels (*1) note, however, that input type can be arbitrarily selected only for channels 9 and 18 irrespective of the type allocated to other channels. *1: used for f value calculation, for example. if an input type is allocated to another channel, or, if the input type of channel 2 is allocated to other channels and several settings are made when the temperature is being measured by connecting k thermocouple to channel 1, it is possible to display a temperature measured by k thermocouple on channel 2. f value calculation is available on channel 1, and the temperature recording is available on channel 2. for setting method, refer to the instruction manual. input type description input type channel 1 k thermocouple thermocouple, 50mv the type of thermocouple can be arbitrarily selected for each channel. channel 2 t thermocouple channel 3 1-5v 5v channel 4 0-5v channel 5 channel 6 channel 7 channel 8 channel 9 channel 10 channel 11 channel 12 channel 13 channel 14 channel 15 channel 16 channel 17 channel 18 pt100 resistance bulb the type of resistance bulb can be arbitrarily selected for each channel. jpt100 500mv 500mv 500mv j thermocouple thermocouple, 50mv input type can be arbitrarily selected for channel 9. k thermocouple 50mv thermocouple, 50mv the input type of the thermocouple and 50mv is the same. skip 1-5v 5v skip and other channel can arbitrarily be selected irrespective of the input type. pt100 skip resistance bulb other channels 500mv 500mv thermocouple, 50mv input type can be arbitrarily selected for channel 18. 50mv printed in japan caution on safety *before using this product, be sure to read its instruction manual in advance. international sales div sales group gate city ohsaki, east t ower , 1 1-2, osaki 1-chome, shinagawa-ku, t okyo 141-0032, japan http://www .fujielectric.com phone: 81-3-5435-7280, 7281 fax: 81-3-5435-7425 http://www .fjielectric.com/products/instruments/ information in this catalog is subject to change without notice.


▲Up To Search▲   

 
Price & Availability of EDS10-74J

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X