Part Number Hot Search : 
SK7473 HFA3683A B2322BG1 250K15 24D05 250K15 ZB4BD2 XR2212
Product Description
Full Text Search
 

To Download 6J4-2 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  v oltage selecting and fused connector with optional rfi power line filter for general purpose applications for ul544 health care equipment the most widely accepted of all the power entry modules, the j series combines an iec connector, 2-voltage, or 4- voltage selection, and a north american fuseholder. it features a compact snap-in design and a unique voltage selector card. j4 models - this general purpose filter provides susceptibility protection from line-to-ground noise on the power line and acts as a high frequency lean--p?ilter for more complex emissions applications. hj4 models - this medical filter provides susceptibility protection without the leakage current associated with line- to-ground capacitors. designed to allow equipment to meet ul544 medical specifications for patient care and non-patient care equipment, the hj filter has a maximum leakage current of 2? at 120 vac 60 hz. see appendix c for more information on medical applications and ul standards. equipment rating labels and mounting clips for thicker panel widths are available as accessories. for more information on ul544 specifications, see appendix c. note: when using the models with an iec connector, remember that the leakage current of the companion line cord, ga400, is more significant than that of the filter - which may disqualify this line cord from use in patient care applications. 114 catalog 1654001 dimensions are in inches and dimensions are shown for usa cust. svc.: 1-800-468-2023 www.corcom.com revised 05-07 millimeters unless otherwise reference purposes only. corcom prods: 1-847-680-7400 www.tycoelectronics.com specified. values in italics specifications subject germany: 49-89-6089-0 are metric equivalents. to change. j series j series corcom product guide ul recognized csa certified 6j4/6J4-2 t erminal view f ront view, all models 6 hj4-1/6hj4-2 terminal view voltage selection unfiltered and filtered models open cover door and rotate fuse-pull lever to left. select operating voltage by orienting voltage selection card, desired voltage on top left side. push card firmly into module slot. rotate fuse-pull lever back into normal position and re-insert fuse into holders. use caution in selecting correct fuse value. unfiltered models available voltage selection part number positions 6vj1 4 6vj1-2 2 unfiltered models available voltage part number selection rfi filter positions type 6vj4 4 general purpose 1 6J4-2 2 general purpose 1 6hj4-4 4 medical 2 6hj4-2 2 medical 2 note 1: general purpose filter for susceptibility applications note 2: medical line filter for very low leakage ul544 health care requirements
specifications m aximum leakage current, each line-to-ground: 6j4 6ehj4 6vj m odels m odels m odels @250 vac 50 hz: 500 ? 5 ? 5 ? hipot rating (one minute): line-to-ground vdc 2250 2250 1550 line-to-line vac 1450 1450 1450 operating frequency: 50/60 hz operating voltages: 6vj1, 6j4, 6hj4-4: 100, 120, 220, 240 vac 6j1-2, 6J4-2, 6hj4-2: 115, 230 vac rated current: 6a fuse (not included): integral fuseholder, line side,accepts .25" x 1.25" fuse terminals: connector block terminals .045" square, suitable for soldering, wire wrapping, or crimp-on lugs 115 catalog 1654001 dimensions are in inches and dimensions are shown for usa cust. svc.: 1-800-468-2023 www.corcom.com revised 05-07 millimeters unless otherwise reference purposes only. corcom prods: 1-847-680-7400 www.tycoelectronics.com specified. values in italics specifications subject germany: 49-89-6089-0 are metric equivalents. to change. p o w e r e n t r y m o d u l e s j series corcom product guide v oltage selecting and fused connector with optional rfi power line filter for general purpose applications for ul544 health care equipment (continued) minimum insertion loss in db: line-to-ground in 50 ohm circuit current frequency-mhz rating .15 .5 1 5 10 20 30 j4 models 6a 9 20 25 41 45 45 48 hj4 models 6a 9 11 15 19 13 12 10 electrical schematics filtered 6j4 & 6J4-2 filtered 6hj4-4 & 6hj4-2 note 1: jumper required if only spst power switch is used. note 2: jumpers required if no input filtering is used. note 3: use only 120v and 240v positions for 2-volt selection units. electrical schematics hot neutral note 1 pilot light transformer primary 100v 120v 100v 20v 120v 220v 240v a a b b c c dd e e f j h f power on-o f f o f f on ground note 3 hot neutral note 1 pilot light transformer primary 100v 120v 1 00v 2 0v 120v 220v 240v a a b b c c dd e e f j h f power on-o f f o f f on ground note 3
116 catalog 1654001 dimensions are in inches and dimensions are shown for usa cust. svc.: 1-800-468-2023 www.corcom.com revised 05-07 millimeters unless otherwise reference purposes only. corcom prods: 1-847-680-7400 www.tycoelectronics.com specified. values in italics specifications subject germany: 49-89-6089-0 are metric equivalents. to change. j series corcom product guide v oltage selecting and fused connector with optional rfi power line filter for general purpose applications for ul544 health care equipment (continued) case styles recommended panel cutout unfiltered and filtered models unfiltered models filtered models * .003 note 4: fuse cover door shown in open condition. note 5: standard units mount in panel thickness of .060 - .090" special mounting clips sold separately for panel thickness of .105-.125". see accessories list on next page. case dimensions part no. ab cd ( max) (max) (max) (max) unfiltered 2.68 1.52 1.17 1.23 6vj1/6vj1-2 68.1 38.6 29.7 31.2 filtered 2.75 1.87 1.17 1.58 6 j4/6J4-2 6 9.9 47.5 29.7 40.1 6hj4-4/6hj4-2 2.75 1.87 1.17 1.58 69.9 47.5 29.7 40.1 mounting diagram (clearance) a c b d note 5 .110 [ 2.79 ] terminals a note 5 .110 [ 2.79 ] terminals c b d note 4 bezel 2.60* 66.0 2.68 68.1 3.00 76.2 1.063* 27.0 1.17 29.7
equipment rating labels unfiltered and filtered models s elf-adhesive labels, as shown below, are available in m ultiples of 40. specify part number. accessories unfiltered and filtered models line cord no. ga400: (7 1/2 foot, 3-conductor line cord to mate with j series) ja302, 2 voltage selector card ( comes standard with 6vj1-2, 6J4-2, 6hj4-2) ja304, 4 voltage selector card (comes standard with 6vj1, 6j4, 6hj4-4) ja403, mounting clips for .105-.125" panel ja500, voltage selector card extractor tool 117 catalog 1654001 dimensions are in inches and dimensions are shown for usa cust. svc.: 1-800-468-2023 www.corcom.com revised 05-07 millimeters unless otherwise reference purposes only. corcom prods: 1-847-680-7400 www.tycoelectronics.com specified. values in italics specifications subject germany: 49-89-6089-0 are metric equivalents. to change. p o w e r e n t r y m o d u l e s j series corcom product guide v oltage selecting and fused connector with optional rfi power line filter for general purpose applications for ul544 health care equipment (continued) 4-volt part ab c number va fuse fuse max. 100/120 (115) 220/240 (230) ja410 25 250 ma 125 ma ja411 50 500 ma 250 ma ja412 100 1a 500 ma ja413 200 2a 1a ja414 250 2.5a 1.25a ja415 300 3a 1.5a ja416 400 4 a 2a ja417 500 5a 2.5a ja418 600 6a 3a ja419 assortment ja410-ja418: 40 labels of one part number ja419: 5 each ja410 - ja418 (45 labels) c c b b a a 2 .330 .210 l ine v. + 5 - 10% 4 8-440 - 50 va max. fuse 100v 120v 220v 2 40v 5 00ma 250ma


▲Up To Search▲   

 
Price & Availability of 6J4-2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X