ver : pa_1 update : 2012.03.09 ac-dc switching power supply AQF600 series 600 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -1- electrical specifications model no. AQF600-12s AQF600-24s AQF600-28s AQF600-36s AQF600-48s AQF600-54s max output wattage (convection) (w) 480w 600w 600w 600w 600w 600w voltage 90-264 vac or 120-370 vdc frequency (hz) 47-63 hz current (full load) < 0.8 a max. (115 vac) / < 4.0 a max. (230 vac) inrush current (<2ms) < 30 a max. (115 vac) / < 60 a max. (230 vac) leakage current < 3.5 ma max.(240vac 63hz) input power factor pf>0.98 (115 vac) / pf>0.93 (230 vac) at full load voltage (v.dc.) 12v 24v 28v 36v 48v 54v trim 5% voltage accuracy 2% current (convection) (a) max 40 25 21.4 16.6 12.5 11.1 line regulation (ll-hl) (typ.) 1% loa d regulation (5-100%) (typ.) 1% minimum load 5% maximum capacitive load 70,000 uf 60,000 uf 48,000 uf 30,000 uf 20,000 uf 10,000 uf ripple & noise (max.) < 1% efficiency (typ.) 90% 91% 92% 92% 93% 93% hold-up time 12 ms min. output switching frequency 100 khz over power protection auto recovery over voltage protection auto recovery over temperature auto recovery protection short circuit protection auto-recovery input-output (v.ac) 3000v input-fg (v.ac) 1500v isolation output-fg . (v.ac) 500v 5v stand by (18cfm fan) 5vsb: 5v@0.6a ; tolerance 10% , ripple & noise: 100m vp-p (max.) dc ok signal turn on: 4~6v ; turn off: 0~1v remote control +rc / -rc: power on=open ; power off=short function fan control 12vdc / 0.5a max. operating temperature -25c?+70c (with derating) storage temperature -25c?+85c temperature coefficient 0.03%/c ( 0~50c ) humidity 95% rh mtbf >120,000 h @ 25c (mil-hdbk-217f) environment vibration 10~500hz, 2g 10min./1cycle, 60min. each along x, y, z axes. key features ? universal input: 90-264 vac ? with p.f.c. function, pf>0.95 ? remote sense function ? remote on/off function ? current share function ? power good function ? protections: over load / over voltage / over temperature / short circuit all by auto-recovery ? high power density ? rohs compliant design ? 3-years product warranty 1. all specifications valid at normal input voltage, full load and +25 c after warm-up time unless o therwise stated. 2. ripple & noise are measured a t 20mhz of bandwidth with 0.1uf & 47uf parallel capacitor.
ver : pa_1 update : 2012.03.09 ac-dc switching power supply AQF600 series 600 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -2- electrical specifications model no. AQF600-12s AQF600-24s AQF600-28s AQF600-36s AQF600-48s AQF600-54s dimension (l x w x h) 9.0 x 4.13 x 1.72 inches (228.5 x 105.0 x 44.0 mm ) tolerance 0.5 mm weight 1200 g physical cooling convection cooled safety agency approvals ce, ul60950 (pending) emi (conducted & radiated emission) en 55022 class b, radiated class a (pending) emc ems (noise immunity) en 55024 (pending) block diagram derating 1. all specifications valid at normal input voltage, full load and +25 c after warm-up time unless o therwise stated. 2. ripple & noise are measured a t 20mhz of bandwidth with 0.1uf & 47uf parallel capacitor.
ver : pa_1 update : 2012.03.09 ac-dc switching power supply AQF600 series 600 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -3- mechanical dimension ac input terminal pin pin# single 1 ac in dc output terminal pin pin# single 2~4 +dc out 5~7 -dc out connector pin (cn4) pin# single c1 +s c2 -s c3 +rc c4 -rc c5 +pg c6 gnd c7 +5v sb c8 -5v sb c9 n.c c10 cs assembly instructions *u case t=2.0mm customer screws into the length of the case no higher than 0.5mm (namely screw length for load plate thickness plus 2.5mm
ver : pa_1 update : 2012.03.09 ac-dc switching power supply AQF600 series 600 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -4- function descripiton of cn4 : pin no. function description c1 +s positive sensing. the +s signal should be connected to the posit ive terminal of the load. the +s and -s leads should be twisted in pa ir to minimize noise pick-up effect. the maximum line drop compensation is 0.5v. (max.) c2 -s negative sensing. the -s signal should be connected to the negat ive terminal of the load. the -s and +s leads should be twisted in pair to minimize noise pick-up effect. the maximum line drop compensation is 0.5v. (max.) c3 +rc turns the output on and off by electrical or dry c ontact between pin c4 (-rc), short: power off, open: power on. c4 -rc remote control ground. c5 dc-ok dc-ok signal is a dc output , referenced to pinc6(dc-ok gnd). c6 gnd this pin connects to the negative te rminal(-v). return for dc-ok signal output. c7 +5v sb stand by voltage output ground 4.5~5.5v, referenced to pin c8(-5v sb). the maximum load current is 0.6a. c8 -5v sb stand by voltage output ground. c9 n.c no pin c10 cs current share function pin function manual : 1. remote sense the remote sensing compensates voltage drop on the load wiring up to 0.5v. (max.) 2. dc-ok signal between dc-ok(pinc5) and gnd(pinc6) output status 4~6v on 0~1v off 3. remote control it can be turned on/off by using the "remote control" function. between rc+(pinc3) and rc-(pinc4) output status sw on (short) off sw off (open) on
|