Part Number Hot Search : 
CHFMG6PT MMBT5 C143Z MSC1205 8B42B C143Z FID3Z1 AD542
Product Description
Full Text Search
 

To Download ASD-IL2F Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  gamewell-fci 12 clintonville road, northford, ct 06472-1610 us a ? tel: (203) 484-7161 ? fax: (203) 484-7118 specifications are for information only, are not intended for in stallation purposes, and are subj ect to change wi thout notice. no responsibility is assumed by gamewell-fci for their use. ?2008 by honeywell international inc. all rights reserved. www.gamewell-fci.com 9020-0619 rev. b3 page 1 of 2 velociti ? series ASD-IL2F analog, addressable ionization smoke sensor description velociti ? and e3 series ? are registered trademarks of honeywell international inc. ul ? is a registered trademark of underwriters laboratories inc. the gamewell-fci velociti ? series, analog address- able plug-in smoke sensors with integral communi- cation provide features that surpass conventional sensors. sensor sensitivity can be programmed in the control panel software . sensitivity is continu- ously monitored and reported to the panel. point id capability allows each sensor?s address to be set, providing exact locations for selective maintenance when the chamber contamination reaches an unac- ceptable level. the ASD-IL2F ionization sensor incorporates a unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. the velociti ? series use a communication protocol that substantially increases the speed of communi- cation between the sensors and certain gamewell- fci analog addressable fire alarm controls. these devices operate in a grouped fashion. if one of the devices in the group has a status change, the panel?s microprocessor stops the group poll and concentrates on the single device. the net effect is response speed up to five times greater than earlier designs. ordering information model description ASD-IL2F analog, addressable ionization smoke sensor features ? sleek, low-profile design ? visual rotary switch addressing ? built-in functional test switch activated by an external magnet ? bicolor leds flash green whenever the sensor is addressed, and light steady red on alarm* ? optional relay, isolator, or sounder bases ? low standby current ? addressable-analog communication ? stable communication technique with noise immunity ? optional remote, single-gang led accessory ra400z ? suitable for installation in ducts note: *only the red led is operative in panels that do not operate in velociti ? mode. ASD-IL2F approved fm 3023594 signaling 07271-0694:199 s1913 mea approved 219-02-e vol.vi an iso 9000-2000 company
gamewell-fci 12 clintonville road, northford, ct 06472-1610 us a ? tel: (203) 484-7161 ? fax: (203) 484-7118 9020-0619 rev. b3 page 2 of 2 www.gamewell-fci.com installation ASD-IL2F plug-in sensors use a separate base to simplify installation, service, and maintenance. a special tool allows maintenance personnel to plug-in and remove the sensors without using a ladder. mount the base on a box which is at least 1.5" (3.8 cm) deep. suitable mounting base boxes include: ?4.0" (10.2 cm) square box. ?3.5" (8.9 cm) or 4.0" (10.2 cm) octagonal box. ? single-gang box (except relay or isolator base). ? with b501bh or b501bht base, use a 4.0" (10.2 cm) square box. ? with b224rb or b224bi base, use a 3.5" (8.9 cm) octag- onal box, or a 4.0" (10.2 cm) octagonal or square box. note: because of the inherent supervision provided by the slc, end-of-line resistors are not required. wiring ?t- taps? or branches are permitt ed for style 4 (class ?b?) wiring. sensor spacing gamewell-fci recommends sp acing sensors in compli- ance with nfpa 72. in low airflow applications with smooth ceilings, space detectors 30 feet (9.144 m) . for spe- cific information regarding sensor spacing, placement, and special applications, refer to nfpa 72. specifications size 2.1? (5.1 cm) high x 4.1? (10.4 cm) diameter installed in b501 base, 6.1? (15.5 cm) diameter installed in adb-flf base shipping weight 5.4 oz. (154 g) operating temperature 32 f to 120 f (0 to 49 c) ul ? -listed velocity range 0-1200 ft./min. (365.8 m/min.) relative humidity 10-93% (non-condensing) electrical specifications voltage range 15 ? 32 volts dc peak. standby current .0003a @ 24 vdc (one communication every 5 seconds with led enabled) maximum alarm current .0065a @ 24 vdc (led lit) bases and options adb-flf 6.1? (15.5 cm) diameter b501 4.1? (10.4 cm) diameter b501bh or b501bht sounder base assembly (b501bht produces a temporal pattern) includes b501 base b224rb relay base screw terminals: up to 14 awg (2.0 mm 2 ) relay type: form-c rating: 2.0a @ 30 vdc resistive 0.3 a @ 110 vdc inductive 1.0 a @ 30 vdc inductive b224rb relay base dimensions 6.2? x 1.2? (15.7 x 3.0 cm) b524bi isolator base dimensions 6.2? x 1.2? (15.7 x 3.0 cm) maximum: 25 devices between isolator bases. ra-400z remote alarm indicator, led bck-200 black detector covers (box of 10)


▲Up To Search▲   

 
Price & Availability of ASD-IL2F

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X