Part Number Hot Search : 
CJF6388 32000 LX1991 GPZ20G NJU7660 BA1404 PST8436U MAX155
Product Description
Full Text Search
 

To Download SOB763670 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  all technical caracteristics are subject to change without previous notice. caract?ristiques sujettes ? modifications sans pr?avis. p p p p r r r r o o o o u u u u d d d d t t t t o o o o s s s s e e e e r r r r v v v v e e e e y y y y o o o o u u u u celduc ? r e l a i s page 1 / 9f/gb s/mon/SOB763670/a/14/09/2007 relais statique biphas? de puissance double power solid state relay okpac ? ? relais statique biphas? asynchrone avec haute immunit? et protection surtension int?gr?e 2 leg random solid state relays with high immunity and internal voltage protection. ? sortie thyristors technologie tms 2 (*) permettant une longue dur?e de vie : 24 ? 510vac 35a back to back thyristors on output with tms 2 (*) technology for a long lifetime expectancy : 24 to 510 vac 35a. ? entr?es doubles avec led de visualisation sur les 2 entr?es de couleur verte. d ouble input with green led visualization on the inputs. ? protection ip20. ip20 protection flaps. ? construit en conformit? aux normes en60947-4-3 (iec947-4-3) et en60950/vde0805 (isolement renforc?) -ul-cul pending designed in conformity with en60947-4-3 (iec947-4-3) and en60950/vde0805 (reinforced insulation) -ul-cul pending ? diff?rentes possibilit?s de connecteur de commande. les relais sont livr?s sans le connecteur de commande. s?lectionner ce connecteur pages 6 ? 9. different possibilities for input connector. input connector is not delivered with the ssr. select input connector in pages 6 to 9. ? sur demande: mod?les asynchrone, avec protection en tension,... on request : random models, voltage protection by vdr or transils output input input output l1 t1 l2 t2 + - 1 2 - + SOB763670 output : 2x35a/24-510vac input : 8-30vdc caract?ristiques d'entr?e / control characteristics (at 25 c) dc param?tre / parameter symbol min typ max tension de commande / control voltage uc 8 30 courant de commande / control current (@ uc ) ic 6 24 tension de non fonctionnement / release voltage uc off 2 led d'entr?e / input led verte / green tension inverse / reverse voltage urv 32 tension de transil d'entr?e / clamping voltage (transil) uclamp 36 immunit? / input immunity : en61000-4-4 2kv immunit? / input immunity : en61000-4-5 2kv input : ic = f( uc) 0 2 4 6 8 10 12 14 16 18 20 22 24 0 24681012141618202224262830 uc (v) ic (ma) www.datasheet.co.kr datasheet pdf - http://www..net/
r e l a i s rue amp?re b.p. 4 42290 sorbiers - france e-mail : celduc-relais@celduc.com fax +33 (0) 4 77 53 85 51 service commercial france t?l. : +33 (0) 4 77 53 90 20 sales dept.for europe tel. : +33 (0) 4 77 53 90 21 sales dept. asia : t?l. +33 (0) 4 77 53 90 19 www.celduc.com celduc ? page 2 / 9f/gb s/mon/SOB763670/a/14/09/2007 okpac ? caract?ristiques de sortie / output characteristics (at 25 c) param?tre / parameter conditions symbol min typ. max unit plage de tension utilisation / operating voltage range ue 24 400 510 v rms tension de cr?te / peak voltage ( + internal vdr) up 1200 (clamp near 910volts) v niveau de synchronisme / zero cross level usync random v tension minimum amor?age / latching voltage ie nom ua 10 v courant nominal / nominal current (ac-51) ie ac-51 35 40 a rms courant surcharge / non repetitive overload current tp=10ms (fig. 3) itsm 400 500 a chute directe ? l'?tat passant / on state voltage drop @ 25 c vt 0,9 v r?sistance dynamique / on state dynamic resistance rt 15 m ? puissance dissip?e (max) par phase/ output power dissipation (max value) by power pd 0,9x0,9xie + 0,015xie 2 w r?sistance thermique jonction/semelle thermal resistance between junction to case rthj/c 0,6 k/w courant de fuite ? l'?tat bloqu? / off state leakage current @ue typ, 50hz ilk 1 ma courant minimum de charge / minimum load current iemin 5 ma temps de fermeture / turn on time @ue typ, 50hz ton max 0,1 ms temps d'ouverture / turn off time @ue typ, 50hz toff max 10 ms fr?quence utilisation / operating frequency range f mains f 0,1 50-60 800 hz dv/dt ? l'?tat bloqu? / off state dv/dt dv/dt 500 v/ s di/dt max / maximum di/dt non repetitive di/dt 50 a/ s i 2 t (<10ms) i 2 t 800 1250 a 2 s immunit? / conducted immunity level iec/en61000-4-4 (bursts) 2kv criterion a immunit? / conducted immunity level iec/en61000-4-5 (surge) 2kv criterion a protection court-circuit / short circuit protection voir/ see page 9 example fuse ferraz grc 25a/32a 14x51 caract?ristiques g?n?rales / general characteristics (at 25 c) symbol isolement entr?e/sortie - input to output insulation ui 4000 vrms isolation sortie/ semelle - output to case insulation ui 4000 vrms r?sistance isolement / insulation resistance ri 1000 (@500vdc) m ? tenue aux tensions de chocs / rated impulse voltage uimp 4000 v degr? de protection / protection level / cei529 ip20 degr? de pollution / pollution degree -2 vibrations / vibration withstand 10 -55 hz according to cei68 double amplitude 1,5 mm tenue aux chocs / shocks withstand according to cei68 - 30/50 g temp?rature de fonctionnement / ambient temperature (no icing, no condensation) - -55 /+100 c temp?rature de stockage / storage temperature (no icing, no condensation) -55/+125 c humidit? relative / ambient humidity hr 40 to 85 % poids/ weight 80 g conformit? / conformity en60947-4-3 (iec947-4-3) conformit? / conformity pending vde0805/en60950 ul/cul plastique du boitier / housing material pa 6 ul94vo semelle / base plate aluminium, nickel-plated www.datasheet.co.kr datasheet pdf - http://www..net/
r e l a i s rue amp?re b.p. 4 42290 sorbiers - france e-mail : celduc-relais@celduc.com fax +33 (0) 4 77 53 85 51 service commercial france t?l. : +33 (0) 4 77 53 90 20 sales dept.for europe tel. : +33 (0) 4 77 53 90 21 sales dept. asia : t?l. +33 (0) 4 77 53 90 19 www.celduc.com page 3 / 9f/gb s/mon/SOB763670/a/14/09/2007 okpac ? celduc ? courbes thermiques / thermal specifications courants de surcharges / overload currents 400 350 300 250 200 150 100 50 10 1 0,1 0,01 time (s) itsm (apeak) 1 2 surcharge de courant : itsm(apeak) = f(t) pour mod?le 35a (itsm=400a) surge current : itsm (apeak) =f(t) for 35a models with itsm=400a 1 -itsm non r?p?titif sans tension r?appliqu?e est donn? pour la d?termination des protections. no repetitive itsm is given without voltagereapplied . this curve is used to define the protection (fuses). 2 -itsm r?p?titif est donn? pour des surcharges de courant (tj initiale=70 c). attention : la r?p?tition de ces surcharges de courant diminue la dur?e de vie du relais. repetitive itsm is given for inrush current with initial tj = 70 c. in normal operation , this curve musn't be exceeded. be careful, the repetition of the surge current decreases the life expectancy of the ssr. ? > warning ! semiconductor relays don't provide any galvanic insulation between the load and the mains. always use in conjunction with an adapted circuit breaker with isolation feature or a similar device in order to ensure a reliable insulation in the ev ent of wrong function and when the relay must be insulated from the mains (maintenance ; if not used for a long duration ...). ? > attention ! les relais ? semi-conducteurs ne procurent pas d'isolation galvanique entre le r?seau et la charge. ils doivent ?tre utilis? s associ?s ? un disjoncteur avec propri?t? de sectionnement ou similaire, afin d'assurer un sectionnement fiable en amont de la l igne dans l'hypoth?se d'une d?faillance et pour tous les cas o? le relais doit ?tre isol? du r?seau (maintenance ; non utilisation sur un e longue dur?e...). 0 5 10 15 20 25 30 35 0 0 10 20 30 40 50 60 70 80 90 100 0 courant de charge / rms load current (a) puissance dissip?e / power dissipation (w) 0 10 20 30 40 50 60 70 80 90 100 0 0 20 40 60 80 100 0 temp?rature ambiante / ambient temperature ( c) 12k/w 6k/w 2,1k/w 1,5k/w full on state 2 legs 1 leg on state 1,1k/w 0,75k/w 0,55k/w www.datasheet.co.kr datasheet pdf - http://www..net/
r e l a i s rue amp?re b.p. 4 42290 sorbiers - france e-mail : celduc-relais@celduc.com fax +33 (0) 4 77 53 85 51 service commercial france t?l. : +33 (0) 4 77 53 90 20 sales dept.for europe tel. : +33 (0) 4 77 53 90 21 sales dept. asia : t?l. +33 (0) 4 77 53 90 19 www.celduc.com celduc ? page 4 / 9f/gb s/mon/SOB763670/a/14/09/2007 okpac ? dimensions sans le connecteur de commande/ dimensions without control connector h h d?pend du type de connecteur de commande. diff?rent mod?les possibles: voir page suivantes h max = 47mm h depends on the type of input connector different solutions are available : see following pages h max = 47mm l1 l2 t1 t2 + + - - in 2 in 1 www.datasheet.co.kr datasheet pdf - http://www..net/
r e l a i s rue amp?re b.p. 4 42290 sorbiers - france e-mail : celduc-relais@celduc.com fax +33 (0) 4 77 53 85 51 service commercial france t?l. : +33 (0) 4 77 53 90 20 sales dept.for europe tel. : +33 (0) 4 77 53 90 21 sales dept. asia : t?l. +33 (0) 4 77 53 90 19 www.celduc.com page 5 / 9f/gb s/mon/SOB763670/a/14/09/2007 okpac ? okpac ? raccordement de puissance / power wiring nombre de fils / number of wires mod?le de tournevis / screwdriver type couple de serrage recommand? 1 2 recommended torque fil rigide (sans embout) solid (no ferrule) fil multibrins (avec embout) fine stranded (with ferrule) fil rigide (sans embout) solid (no ferrule) fil multibrins (avec embout) fine stranded (with ferrule) m5 n.m 1,5 ... 10 mm 2 awg16....awg8 1,5 ... 6 mm 2 awg16....awg10 1,5 ... 10 mm 2 awg16....awg8 1,5 ... 6 mm 2 awg16....awg10 pozidriv 2 2 raccordement de puissance / power connections celduc ? directement avec fils avec ou sans embouts/ direct connection with wires with or without ferrules avec cosses/ with ring terminals puissance avec cosses / power with ring terminals. w max = 12,6mm 16 mm 2 (awg6) 25 mm 2 (awg4) 35mm 2 (awg2 /awg3) 50mm 2 (awg0 /awg1) des cosses et kits d'adaptation peuvent ?tre fournis : voir relais forte puissance et documentation connexion forte puissance/ suitable ring terminals and spe- cial kit for high current can be delivered: see high power ssr and data-sheet for power connexion. nouvelles bornes avec rondelles freins new terminals with washers www.datasheet.co.kr datasheet pdf - http://www..net/
r e l a i s rue amp?re b.p. 4 42290 sorbiers - france e-mail : celduc-relais@celduc.com fax +33 (0) 4 77 53 85 51 service commercial france t?l. : +33 (0) 4 77 53 90 20 sales dept.for europe tel. : +33 (0) 4 77 53 90 21 sales dept. asia : t?l. +33 (0) 4 77 53 90 19 www.celduc.com page 6 / 9f/gb s/mon/SOB763670/a/14/09/2007 okpac ? raccordement de commande par connecteur d?brochable / control connections by pluggable connector celduc ? diff?rentes possibilit?s de connecteurs et de sortie/ different possibilities of connectors and outputs connecteur ? vis screw solution screw 270 screw 90 screw 45 1 2 3 1 4 2 3 4 double ref : 1y042217 weidmuller: blz5,08/4/225sn sw 1741890000 ref : 1y041660 weidmuller: bldt5,08/4 sn sw 1660730000 ref : 1y042715 weidmuller: blz5,08/4/270sn sw 1557510000 ref : 1y040915 weidmuller: blz5,08/4/90sn sw 1552910000 single wire = 0,15...2,5mm 2 26-12awg wire strip length = 7mm single wire = 0,15...2,5mm 2 26-12awg wire strip length = 7mm single wire = 0,15...2,5mm 2 26-12awg wire strip length = 8mm single wire = 0,15...2,5mm 2 26-12awg wire strip length = 7mm www.datasheet.co.kr datasheet pdf - http://www..net/
r e l a i s rue amp?re b.p. 4 42290 sorbiers - france e-mail : celduc-relais@celduc.com fax +33 (0) 4 77 53 85 51 service commercial france t?l. : +33 (0) 4 77 53 90 20 sales dept.for europe tel. : +33 (0) 4 77 53 90 21 sales dept. asia : t?l. +33 (0) 4 77 53 90 19 www.celduc.com page 7 / 9f/gb s/mon/SOB763670/a/14/09/2007 okpac ? raccordement de commande par connecteur d?brochable / control connections by pluggable connector celduc ? diff?rentes possibilit?s de connecteurs et de sortie/ different possibilities of connectors and outputs solution ressort spring solutions 180 270 90 put and remove a wire www.datasheet.co.kr datasheet pdf - http://www..net/


▲Up To Search▲   

 
Price & Availability of SOB763670

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X