If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
level transmitter the fcx -a iii level transmitter accurately measures liq uid level and transmits a proportional 4 to 20ma signal. the trans- mitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor tech nology to provide exceptional performance and functionality. 1. high accuracy 0.2% accuracy for all calibrated spans is a standard feature for all models covering 0.32kpa {3.2mbar} range to 500kpa {5bar} high differential pressure range. 0.1% accuracy is available as option. fuji?s micro-capacitance silicon sensor assures this accuracy for all elevated or suppressed calibra tion ranges without additional adjust- ment. 2. minimum environmental in uence the ?advanced floating cell? design which protects the pressure sensor against changes in tempera ture, static pressure, and overpressure substantially re duces total measurement error in actual ? eld applications. 3. fuji/hart bilingual communications protocol fcx -a iii series transmitter offers bilingual communica- tions to speak both fuji proprietary protocol and hart ? . any hart ? compatible devices can communicate with fcx -a iii . 4. application exibility various options that render the fcx -a iii suitable for almost any process applications include: ? full range of hazardous area approvals ? built-in rfi ? lter and lightning arrester ? 5-digit lcd meter with engineering unit ? stainless steel electronics housing ? wide selection of materials ? high temperature, high vacuum service. 5. programmable output linearization function output signal can be freely programmable. (up to 14 compensated points at approximation.) 6. burnout current exibility (under scale: 3.2 to 4.0ma, over scale: 20.0 to 22.5ma) burnout signal level is adjustable using model fxw hand held communicator (hhc) to comply with namur ne43. 7. dry calibration without reference pressure thanks to the best combination of unique construction of mechanical parts (sensor unit) and high performance electronics circuit (electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. data sheet fke ... 5 date EDSX7-66H aug. 10, 2011 features specifications functional speci cations service: liquid, gas, or vapour static pressure, span, and range limit: remark: to minimize environmental in? uence, span should be greater than 1 /40 of the max. span in most applications. ? lower limit of static pressure (vacuum limit) ; silicone ? ll sensor: see fig.1 fluorinated ? ll sensor: 66kpa abs (500mmhg abs) at temperature below 60 c. ? the maximum span of each sensor can be converted to different units using factors as below. 1mpa=10 3 kpa=10bar=10.19716kgf/cm 2 =145.0377psi 1kpa=10mbar=101.9716mmh 2 o=4.01463inh 2 o overrange limit: to maximum static pressure limit output signal: 4 to 20ma dc with digital signal superim- posed on the 4 to 20ma signal power supply: transmitter operates on 10.5v to 45v dc at transmitter terminals. 10.5v to 32v dc for the units with optional arrester. range limit [kpa] {m bar} fke 3 fke 5 fke 6 type span limit [kpa] {m bar} +/? 32 { +/? 320} +/? 130 { +/? 1300} +/? 500 { +/? 5000} max. 0.32 {3.2} 1.3 {13} 5 {50} min. static pressure ? ? ? 32 {320} 130 {1300} 500 {5000} up to ? ange rating
2 fke ... 5 process: load limitations: see ? gure below 2000 [] 1500 1000 load resistance 500 250 0 1474 577 operating area 24v 45v 10 16.35 50 e[ v ] 10.5v power voltage (dc) r= e-10.5 (imax+0.9)x10 -3 note: for communication with hhc (1) (model: fxw), min. of 250 : required. hazardous locations: see table 2 zero/span adjustment: zero and span are adjustable from the hhc (1) . zero and span are also adjustable externally from the adjustment screw. damping: adjustable from hhc or local con? gurator unit with lcd display. the time constant is adjustable between 0.06 to 32 seconds. zero elevation/suppression: ?100% to + 100% of url normal/reverse action: selectable from hhc (1) indication: analog indicator or 5-digit lcd meter, as speci? ed. burnout direction: selectable from hhc (1) if self-diagnostic detect transmitter failure, the analog signal will be driven to either ?output hold?, ?output overscale? or ?output underscale? modes. ?output hold?: output signal is hold as the value just before failure happens. ?output overscale?: adjustable within the range 20.0ma to 22.5ma from hhc (1) ?output underscale?: adjustable within the range 3.2ma to 4.0ma from hhc (1) 3.2 4 20 22.5 [ma] over scale burnout probable over range probable under range normal operating range under scale burnout output limits comforming the namur ne43 by order. loop-check output: transmitter can be con? gured to provide constant signal 3.2ma through 22.5ma by hhc (1) . temperature limit: ambient: ?40 to + 85c (?20 to + 80c for lcd indicator) (?40 to + 60c for arrester option) (?10 to + 60c for ? uorinated oil ? ll transmitter) for explosionproof units (? ameproof or intrinsic safety), ambient temperature must be within the limits speci- ? ed in each standard. storage: ?40 to + 90c humidity limit: 0 to 100% rh communication: with hhc (1) (model fxw, consult data sheet no. eds8-47), following items can be remotely displayed or con? gured. note: hhc?s version must be higher than 7.0 (or fxw 1? 4), for fcx -a iii . local con gurator with lcd display (option): local con? gurator with 3 push button and lcd display can support following items. items by communication with fxw by local con? gurator (with 3 push button) display set display set tag no. vvvv model no. vvvv serial no. & software version v ? v ? engineering unit vvvv range limit v ? v ? measuring range vvvv damping vvvv output mode v ? v ? burnout direction vvvv calibration vvvv output adjust ? v ? v data v ? v ? self diagnoses v ? v ? printer (in case of fxw with printer option) v ??? external switch lock vvvv transmitter display vvvv linearize vv ?? rerange vvvv saturate current vvvv write protect vvvv history ? calibration history ? ambient temperature history v v v ? v v v ? programmable output linearization function: output signal can be characterized with ?14 points linear approximation function? from hhc (1) . emc conformity: en61326-1: 2006 atmospheric pressure 2.7kpa abs {20.3mmhg abs} 0.13kpa abs {0.98mmhg abs} w, a and d h j y and g s t k fluorinated oil silicone oil ?20 to 120c ?15 to 250c 20 to 300c ?40 to 120c ?15 to 250c 20 to 300c ?15 to 150c low pressure side contact liquid temperature on transmitter of code h, j, s, t is 120c or lower. low pressure side contact liquid temperature of code k is 85c or lower code in the 13th digit of ?code symbols? process temperature lower limit of static press (note) (1) hhc: hand held communicator 3 mounting position effect: zero shift, less than 0.3kpa {3m bar} for a 10 tilt in any plane. (no extension) no effect on span. this error can be corrected by adjusting zero. dielectric strength: 500v ac, 50/60hz 1 min., between cir cuit and earth. insulation resistance: more than 100m ? at 500v dc. internal resistance for external eld indicator: 12 ? or less 0.1 x url span () 0.1 + 0.1 % of span performance speci cations reference conditions, silicone oil ? ll, 316ss isolating diaphragms, 4-20 ma analog output in linear mode. accuracy rating: (including linearity, hysteresis, and re- peatability) (standard) for spans greater than 1 /10 of url: 0.2% of span for spans below 1 /10 of url: (option) (code: 21th digit h, k) for span greater than 1 /10 of url: 0.1% of span for span below 1 /10 of url: stability: 0.2% of upper range limit (url) for 10 years. temperature effect: effects per 28c change between the limits of ?40c and +85c time constant (at 23c) 0.55 s 0.3 s range code ?3? ?5? and ?6? dead time 0.12 s static pressure effect: zero shift: 0.2% of url / 1mpa span shift: ?0.2% of calibrated span / 1mpa overrange effect: zero shift; 0.1% of url for ? ange rating pressure supply voltage effect: less than 0.005% of calibrated span per 1v update rate: 60 msec step response: (without electrical damping) (standard) zero shift: total effect: (option) (code: 21th digit j, k) zero shift: 0.3% (x>1/4url) total effect: 0.4% (x>1/4url) 0.1 x url span () 0.05 + 0.05 % of span url x () 0.35 % url x () 0.5 % 0.25 x url x () 0.1 + 0.2 %(x<1/4url) 0.25 x url x () 0.2 + 0.2 %(x<1/4url) physical speci cations electrical connections: g 1 /2 , 1 /2 -14 npt, pg13.5, or m20 x 1.5 conduit, as speci? ed. process connections: lp side: 1 /4 -18 npt or rc 1 /4 . hp side: ansi, din, or jis raised face flange. see outline diagram for detailed dimensions. refer to ?code symbols? process-wetted parts material: non-wetted parts material: electronics housing: low copper die-cast aluminum alloy ? nished with polyester coat ing (standard), or 316 stainless steel (astm cf8m), as speci? ed. bolts and nuts: cr-mo alloy (standard) or 304 stainless steel fill ? uid: silicone oil (standard) or ? uori- nated oil mounting ? ange: 304 stainless steel or carbon steel, as speci? ed environmental protection: iec ip67 and nema 6 / 6p flange mounting: see drawings mass {weight}: transmitter approximately 10.2 to 19.2kg without options. add; 0.5kg for mounting bracket 4.5kg for stainless steel housing option 1.0kg per 50mm extension of diaphragm v j c d e h m t p r process cover 316 stainless (* 1 ) 316 stainless (* 1 ) 316 stainless (* 1 ) 316 stainless (* 1 ) 316 stainless (* 1 ) 316 stainless (* 1 ) 316 stainless (* 1 ) 316 stainless (* 1 ) 316 stainless (* 1 ) 316 stainless (* 1 ) diaphragm 316l stainless 316l stainless 316l stainless 316l stainless 316l stainless hastelloy-c monel tantalum 316l stainless 316l stainless material code (7th digit in ?code symbols?) lp side wetted sensor body 316 stainless 316 stainless 316 stainless 316 stainless 316 stainless hastelloy-c lining monel lining tantalum lining 316 stainless 316 stainless hp side diaphragm & ? ange face 316l stainless 316l stainless steel +au coating hastelloy-c monel tantalum hastelloy-c monel tantalum tantalum zirconium note: (* 1 ) scs14a per jis g 5121 (equivalent cf8m per astm a351/a351m) remark: sensor o-rings: viton o-ring and te? on gasket select- able. 4 fke ... 5 optional features indicator: a plug-in analog indicator (2.5% accu- racy). an optional 5-digit lcd meter with engi- neering unit is also available. local con gurator with lcd display: an optional 5 digits lcd meter with 3 push buttons can support items as using communication with fxw. arrester: a built-in arrester protects the electronics from lightning surges. lightning surge immunity: 4kv (1.2 50s) oxygen service: special cleaning procedures are followed throughout the process to maintain all process wetted parts oil-free. the ? ll ? uid is ? uorinated oil. chlorine service: oil-free procedures as above. includes ? uorinated oil for ? ll. degreasing: process-wetted parts are cleaned, but the ? ll ? uid is standard silicone oil. not for use on oxygen or chlorine measure- ment. vacuum service: special silicone oil and ? lling procedure are applied. see fig.1 and fig.2 optional tag plate: an extra stainless steel tag with customer tag data is wired to the transmitter. coating of cell: cell?s surface is ? nished with epoxy/poly- urethane double coating. specify if environment is extremely cor- rosive. fig. 1 r elation between process temperature and operating pressure fig. 2 relation between process temperature and operating pressure silicone (code y,g) silicone (code s) operating area silicone (code t) 101 {1010} 53.3 {533} 13.3 {133} 2.7 {27} [kpa abs] {mbar abs} operating pressure C40 C15 60 20 85 120 200 230 250 300 process temperature[c ] operating area non-operating area 101 {1010} 0.13 {1.3} [kpa abs] {mbar abs} operating pressure C15 150 process temperature[c ] sealing liquid:silicone (code k) 5 accessories oval anges: (model ffp, refer to data sheet no. eds6- 128) converts process connection to 1 /2 -14 npt or to rc 1 /2 ; in carbon steel or in 316 stainless steel. hand held communicator: (model fxw, refer to data sheet no. eds 8-47) ordering information when ordering this instrument, specify: 1. code symbols 2. measuring range 3. output orientation (burnout direction) when abnormality is occurred in the transmitter. hold / overscale / underscale. unless otherwise speci? ed, output hold function is sup- plied. 4. indication method (indicated value and unit) in case of the actual scale (code d, h, p, s, 2, 5 on 9th digit). 5. tag no. (up to 14 alphanumerical characters), if re- quired. 6 fke ... 5 5 6 7 8 9 s t v w x hp side lp side 0 1 2 3 4 5 6 7 8 9 m r a b c d e f g h j k s t u v w x 3 5 6 v c d e j h m t p r diaphragm 316l stainless steel 316l stainless steel 316l stainless steel 316l stainless steel 316l stainless steel hastelloy-c monel tantalum 316l stainless steel 316l stainless steel diaphragm and flange face 316l stainless steel hastelloy-c monel tantalum diaphram: 316l stainless steel +au coating flange face: 316 stainless steel hastelloy-c monel tantalum titanium zirconium wetted sensor body 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel hastelloy-c lining monel lining tantalum lining 316 stainless steel 316 stainless steel 7 8 fke ... 5 9 d p o e v j u d p o o 1 s f t t $ p o o ( 0 w b m q b o h f t d s f x 6 / ' 4 $ 3 & |