  Datasheet File OCR Text:
  data sheet flc ... 2, fld portaflow-x is a portable type ultrasonic fowmeter utilizing transit time difference for measuring fow rates in pipes from the outside. it is a compact and light-weight instrument incorporating the latest electronics and digital signal processing technolo - gies, realizing high performance and easy operation. fluid conditions measured fuid: homogeneous liquids (water, sea water, oil or fuid of unknown sound velocity) capable of ultrasonic wave propagation turbidity of fuid: 10000 deg. (mg/ ? ) or less state of fow: axis-symmetric fow in pipe flled with fuid fluid temperature: small diameter sensor, C 40 to +100c small sensor, [standard] C 40 to +100c middle sensor, C 40 to +8c large sensor, C 40 to +80c high-temperature sensor, C 40 to +200c velocity range: C 32 to 0 to +32m/s piping conditions pipe material: steel, stainless steel, cast iron, vinyl- chloride, frp, asbestos, aluminum, acrylic, etc. pipe size: small diameter sensor, 13 to 100 small sensor, 50 to 400 middle sensor, 200 to 1200 large sensor, 200 to 6000 high-temperature sensor, 50 to 400 lining material: none, tar epoxy, mortar, rubber or mate - rial of known sound velocity straight pipe length: upstream side, 10d or more downstream side, 5d or more (d: inner pipe diameter) refer to japan electric measuring in - struments manufactures associations standard jemis-032 for details. 1. compact and light-weight the adoption of the latest electronics and digital signal processing technologies has reduced the size and weight of the converter to 1/7 and 1/5, respectively, in comparison with traditional model. 2. battery operation this fowmeter is designed for 5 hours of continuous operation with its own built-in battery which is re - chargeable in 2 hours with the supplied power adaptor. 3. full variety of sensors the fowmeter can be used with various types of sen - sors applicable for small to large diameter pipe ( 13 to 6000) and low to high temperature (C40 to +200c). 4. high accuracy the fowmeter is designed for high accuracy ( 1.0%). the adoption of new sound velocity measurement sys - tem permits measurements of fuids of unknown sound velocity, and also slightly affection from fuid tempera - ture and pressure. 5. improvement in anti-bubble characteristic anti-bubble characteristic is greatly improved by digital signal processing. 6. quick response with the use of high-speed micro-processor suited for digital signal processing, the response time is at fast as 1 second or less. 7. multi-lingual the following languages are supported for display: jap - anese (katakana), english, german and french. 8. excellent performance and easy operation large type graphic lcd and minimum number of func - tion keys are used for page selection, allowing easy set - ting. C lcd with back light C equipped with 40000 data logging function of 20 sites C equipped with received wave monitoring function C equipped with serial communication function C easy mounting of sensor C integrated type graphic printer (option) converter (type: flc) detector (type: fld12) ultrasonic flowmeter portable type features specifications EDSX6-95F may. 8, 2006 date
flc ... 2, fld  kind sensor case mounting bracket small diameter plastic aluminum alloy + plastic small type plastic aluminum alloy + plastic middle type plastic large type plastic high temperature 304ss aluminum alloy + 304ss kind dimensions (hxwxd) mass small diameter 420 x 53 x 90mm 0.6kg small type 540 x 53 x 90mm 0.8kg middle type 72 x 60 x 40mm 0.4kg (note) large type 104 x 93 x 62mm 1.4kg (note) high temperature 530 x 52 x 205mm 1.7kg note: mass of both sensors accuracy 1.5% of rate 0.03m/s 1.0% of rate 0.02m/s 1.0% of rate 0.01m/s flow velocity 2 to 32 m/s 0 to 2 m/s 2 to 32 m/s 0 to 2 m/s 1 to 32 m/s 0 to 1 m/s pipe size 13 to 50 or less 50 to 300 or less 300 to 6000 (note) reference conditions are based on jemis-032. converter (type:flc) power supply: built-in battery or power adaptor built-in battery: special type ni-mh battery continuous operation time, about 5 hours (without printer, back light off, analog output off, trans voltage 1 time) recharging time, about 2 hours (power adaptor used) power adaptor: special type power adaptor 90 to 264v ac, 47 to 63hz or 10 to 30v dc power consumption: 12w or less lcd display: full dot graphic display 240 x 320 dot (with back light) led display: dc in (green), fast charge (red) key pad: 10 keys (on, off, r , s , w , v , esc, ent, light, print) power failure backup: memory backup with lithium battery (effective term, 5 years) response time: 1s or less output signal: 4 to 20ma dc, 1 point (load resistance, 0 to 1k w ) input signal: 4 to 20ma dc (not isolated), 1 point serial communication: rs-232c (not isolated), 1 point transmission speed: max. 9600bps transmission distance: max. 15m printer (option): to be mounted on top of converter thermal serial dot printing (8 x 256 dot) ambient temperature: C10 to +55c (without printer) C10 to +45c (with printer) ambient humidity: 90% rh or less type of enclosure: dust-proof type (ip50 or equivalent) enclosure case: plastic case (color: gray) dimensions: h240 x w127 x d70mm (without print - er) h359 x w127 x d70mm (with printer) mass: 1.5kg (without printer) 2.0kg (with printer) detector (type: fld) mounting method: mounting on outside of already con - structed pipe sensor mounting method: v or z method mounting belt /wire: small diameter sensor, plastic cloth belt small sensor, plastic cloth belt middle sensor, stainless wire large sensor, stainless wire high-temperature sensor, stainless belt acoustic coupler: silicone grease signal cable: special type coaxial cable connection: converter; bnc connector sensor, middle/large type; terminal screws other; bnc connector ambient temperature: C20 to +60c ambient humidity: middle/large sensor, 100% rh or less other, 90% rh or less type of enclosure: middle/large sensor, immersion-proof type (ip67 or equivalent) other, drip-proof type (ip52 or equivalent) material: dimensions/mass: accuracy
 functions display language: japanese (katakana) / english / german/ french, selectable instantaneous value display function: two of velocity, fow rate (with fow di - rection) and analog input, simultaneous display unit; metric/english system selectable metric system: velocity m/s flow rate ? /s, ? /min, ? /h, m ? /d, m 3 /s, m 3 /min, m 3 /h, mm 3 /d, bbl/s, bbl/min, bbl/h, mbbl/d english system: velocity ft/s flow rate gal/s, gal/min, gal/h, mgal/d, ft 3 /s, ft 3 /min, ft 3 /h, mft 3 /d, bbl/s, bbl/min, bbl/h, mbbl/d note: gal refers to u.s. gallons. total value display function: forward and reverse total values, simul - taneous display unit; metric/english system, selectable metric system: m ? , ? , m 3 , km 3 , mm 3 mbbl, bbl, kbbl english system: gal, kgal, ft 3 , kft 3 , mft 3 mbbl, bbl, kbbl clock display function: time (year, month, day, hour, minute) display and setting damping: 0 to 99s (time constant) low fow cut: 0 to 1.000m/s 0 to 3.300 ft/s output setting function: current output scaling, output type, burnout setting and calibration communication function: velocity, fow rate, totals, analog input, status, logging data transmission on re - quest logging function: site data (place, piping, fuid, sensor mounting method, type of sensor) up to 20 places and a maximum of 40000 data (time, velocity, fow rate, totals, analog input, status) can be stored in memory. waveform display function: display of bi-directional received wave - forms graph display function: display of velocity, fow rate or analog input trend graph printing function: printout of screen, fxed cycle printout (time, velocity, fow rate, totals, analog input, status), logging data, trend graph, and waveforms by using integral printer (option) plastic wedge pzt oscillator pipe lining cable detector converte r dc 4~20ma cable detector converte r dc 4~20ma mounting of detector (2) single-measuring-path system (z method) measuring principle with ultrasonic pulses propagated diagonally between the upstream and downstream sensors, fow rate is measured by detecting the time difference obtained by the fow of fuid. configuration diagram (1) single-measuring-path system (v method) upstream sensor flow velocity v downstream sensor t 1 t 2 detector q d con- verter output signal
flc ... 2, fld  fluid temperature ( c ) 200 100 80 0 C40 13 50 100 200 400 6000 1200 pipe size (mm) small diameter sensor standard sensor (small type) high-temperature sensor large sensor middle sensor detector selection guide description 1 f l d 1 2 3 4 5 6 7 8 9 kind small sensor (standard) small diameter sensor high-temperature sensor middle sensor large sensor terminal mold none provided (middle/large sensor only) structure general use coaxial cable 5m 0 1 y a 1 2 2 2 3 2 4 1 5 1 t h e p ro d u c t c o n fo r m s t o t h e re q u i re m e n t s o f t h e electromagnetic compatibility directive 89/336/eec as detailed within the technical construction file number tn510423. the applicable standards used to demonstrate compliance are :- en 55011:1991 conducted and radiated emissions class a en 50082-1 :-1992 radiated immunity, esd and fbt description 2 f l c 0 1 2 3 4 5 6 7 8 specification standard converter basic system basic system + printer power adapter ac power (90 to 264v ac, 50/60hz) 1 2 1 s note: dc power adapter is optional accesoories. code symbols [note] 1. high turbid fuid or scales sticking on the internal wall of pipes may interrupt the ultrasonic propagations. 2. in case of cast iron pipes or pipes with lining, the large sensor is recommended rather than the middle sensor.
 scope of delivery drawing no. tk7m7039c1 tk7g7976c1 tk7g7977c1 tk7g7978c1 tk7g7982c1 tk7g7984c1 tk7g7983c1 tk468664c5 tk7g7987c1 tk468664c3 tk468664c4 tk7g7974c1 tk7g7979c1 tk7g7980c3 tk7g7980c5 tk7g7981c1 ti-50k name of unit 1 basic system 2 printer item 1 battery 2 power adaptor 3 printer unit 4 printer roll paper 5 silicone grease 6 signal cable 7 extension signal cable 8 analog input/output cable 9 mounting belt/wire 10 pipe thickness gauge converter (type: flc) detector (type: fld) name of unit 1 small diameter/small/ m i d d l e / l a r g e / h i g h temperature scope of delivery 1) sensor unit 2) signal cable (5m, 2 cables) 3) mounting belt/wire 4) silicone grease (100g) (note) small sensor and small diameter sensor can be put in the basic system carrying case. scope of delivery 1) converter unit 2) power adaptor 3) power cable (2m) 4) analog input/output cable (1.5m) 5) carrying case 6) manual 1) printer unit 2) roll paper (1 roll) optional accessories specifcation special type ni-mh battery (12v, 1350mah) special type power adaptor, with power cable, 2m 90 to 264v ac, 47 to 63hz 10 to 30v dc (with car cigarette cable) mounted on top of converter, with roll paper (1 roll), thermal serial dot system (8 x 256 dot) maker: seiko i type: tp080C20lj1 specifcation: thermal roll paper, 80mm wide x 40, without core maker: shin-etsu type: standard g40m, 100g high temperature ks62m, 100g special type signal cable, 5m x 2 middle/large sensor; bnc connector on one side other: bnc connector on both sides special type coaxial cable with bnc connector 10m x 2 50m x 2 4-core cable, 1.5m, with connector small/small diameter sensor: plastic cloth belt middle sensor: stainless wire large sensor: stainless wire high-temperature sensor: stainless belt maker: kawatetsu advantech type: tiC50k specification: material; cop per, c ast iron, aluminum, glass, hard resin, ceramic, etc. measuring range; 0.8 to 80mm accuracy; 0.1mm or 0.5% rd
flc ... 2, fld  scale(inch) cursor 52.5 scale(mm) distance between two sensors 0~128 90 max 36 320 saddle bnc connector lock nut element holder detector fld22 ( s mall diameter sensor) scale(inch) cursor 52.5 90 max 36 540 scale(mm) distance between two sensors 0~335 saddle bnc connector lock nut element holder ent esc print light on off dc in fast charge stream down stream up senso r analog in/ou t dc17.5v serial feed on of f 127 359 70 printer dc power input sensor input (downstream) sensor input (upstream) serial communication port analog input/output power switch ent esc print light on off dc in fast charge stream dow n stream up sensor analog in/out dc17.5 v serial sensor input(upstream) sensor input(downstream) serial communication port analog input/output power switch dc power input 70 127 240 outline diagram (unit:mm) converter flcs1 converter flc2 (with printer) detector fld12 ( s mall sensor)
 external connection diagram 114 93 sensor unit 104 62 19 cable(5m long) wire rope mounting spring bnc connector f detector fld51 ( l arge sensor) serial communication analog input/output pin no. 1 2 3 4 pin no. 1 2 3 4 5 6 7 8 9 symbol r x d t x d d t r g n d d s r r t s c t s item receive data send data data terminal ready signal ground data set ready send request send ready sensor input/output item analog input + analog output C analog input C analog output + power input (power adaptor output) color black red white blue connector : d-sub 9 pin plug (male) 6 1 5 9 flc,fld-p6-c 4 2 3 1 flc,fld-p6-d dc17.5v flc,fld-p6-f fld,flc-p6-e fld,flc-p6-e upstream side downstream side connector : circular connector 4 pin scale(inch) scale(mm) cursor f 26 52 distance between two sensors 0~330 saddle bnc connector lock nut element holder 90 max 205 max 33 33 530 33 detector fld32 ( h igh-temperature sensor) detector fld41 ( m iddle sensor) 72 40 114 60 19 detector cable(length : 5m) bnc connecter wire rope grand terminal mounting spring
flc ... 2, fld information in this catalog is subject to change without notice. printed in japan head office gate city ohsaki, east t ower , 11-2, osaki 1-chome, shinagawa-ku, t okyo 141-0032, japan http://www .fesys.co.jp/eng instrumentation div . international sales dept. no.1, fuji-machi, hino-city , t okyo, 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187 http://www .fic-net.jp/eng caution on safety *before using this product, be sure to read its instruction manual in advance.


▲Up To Search▲   

 