  Datasheet File OCR Text:
  small flange remote seal type differential pressure transmitter data sheet features the fcx? 2 small flange remote seal type differential pressure transmitter accurately measures differential pressure, liquid level or gauge pressure and transmits a proportional 4 to 20ma signal. the transmitter utilizes a unique micromachined capacitance silicon sensor with state- of-the-art microprocessor technology to provide exceptional performance and functionality. totally welded construction of the seals assures excellent reliability in high temperature and highly corrosive process conditions. 1. directly connectable to 1- 1 /2 in and 2in flanges the transmitter is connectable to 1- 1 /2 in and 2in pipes without a reducer. 2. flow measurement without impulse piping 1 /2 in and 3 /4 in flange size is also available. this differ- ential pressure transmitter allows connection to 1 /2 in and 3 /4 in flanges of a general size for the orifice tap, which eliminates the need of using a impulse piping. problems with the impulse piping, such as clogging, leaks or corrosion can be solved. in addition, the following process connection is also available. screw connection 1 /2 -14npt, 3 /4 -14npt, rc 1 /2 , rc 3 /4 3. minimum environmental influence the ?dvanced floating cell?design which protects the pressure sensor against changes in temperature, static pressure, and overpressure substantially reduces total measurement error in actual field applications. 4. fuji/hart bilingual communications protocol and foundation fieldbus and profibus compatibil- ity fcxa 2 series transmitter offers bilingual communi- cations to speak both fuji proprietary protocol and hart . any hart compatible devices can commu- nicate with fcxa 2 . further, by upgrading electron- ics foundation fieldbus and profibus are also available. 5. application flexibility various options that render the fcx? 2 suitable for almost any process applications include: analog indicator at either the electronics side or terminal side full range of hazardous area approvals built-in rfi filter and lightning arrester ? -digit lcd meter with engineering unit stainless steel electronics housing wide selection of materials high temperature, high vacuum seals 6. programmable output linearization function in addition to linear and square root, output signal can be freely programmable. (up to 14 compensated points at approximation.) 7. burnout current flexibility (under scale: 3.2 to 3.8ma, over scale: 20.8 to 21.6ma) burnout signal level is adjustable using model fxw hand held communicator (hhc) to comply with namur ne43. 9. dry calibration without reference pressure thanks to the best combination of unique construction of mechanical parts (sensor unit) and high performance electronics circuit (electronics unit), reliability of dry cali- bration without reference pressure is at equal level as wet calibration. fkx ... 4 date EDSX6-116K apr. 1, 2007 specifications functional specifications service: liquid, gas, or vapour static pressure, span, and range limit: maximum static pressure limit for screw connction type: 4.2mpa lower limit of static pressure (vacuum limit), silicone fill sensor: see fig. 1 fluorinated fill sensor: atmospheric pressure the maximum span of each sensor can be converted to different units using factors as below. 1mpa =10 3 kpa=10bar=10.19716kgf/cm 2 =145.0377psi 1kpa=10mbar=101.976mmh 2 o=4.01463h 2 o up to flange rating f kx 3 f kx 5 f kx 6 +/?32 {+/?320} +/?130 {+/?1300} +/?500 {+/?5000} 3 { 30} 13 {130} 50 {500} 32 { 320 } 130 { 1300 } 500 { 5000 } min. type range limit [kpa] {m bar} span limit [kpa] (m bar} max. static pressure
2 fkx ... 4 (note) (1) hhc: hand held communicator overrange limit: to maximum static pressure limit output signal: 4 to 20ma dc (linear or square root) with digital signal superimposed on the 4 to 20ma signal. power supply: transmitter operates on 10.5v to 45v dc at transmitter terminals. 10.5v to 32v dc for the units with optional arrester. load limitations: see figure below note: for communication with hhc (1) (model: fxw), min. of 250 ? is required. hazardous locations: 2000 [ ? ] 1500 1000 load resistance 500 250 0 1533 ? 600 ? operating area 24v 45v 10 16.1 50 [ v ] 10.5v power voltage a tex ex ii 2 gd eex d iic t6 ip66/67 t85 c tamb = -40 c to +65 c eex d iic t5 ip66/67 t100 c tamb = -40 c to +85 c factory mutual class i div.1 groups b, c, d t6 type 4x class ii iii div.1 groups e, f, g t6 type 4x tamb max = +60 c authorities flameproof iecex scheme /saa ex d iic t5 ip66/67 pending tamb = -40 c to +85 c ex d iic t6 ip66/67 pending tamb = -40 c to +65 c tiis ex do iib+h 2 t4 tamb max = +55 c maximum process temp.=+120 c csa - a tex ex ii 1 gd eex ia iic t5 tamb = -40 c to +40 c eex ia iic t4 tamb = -40 c to +80 c entity parameters: ui=28v, ii=93.3ma, pi=0.66w, ci=27nf (without arrester), ci=34.2nf (with arrester), li=1.134mh factory mutual class i ii iii div.1 groups a, b, c, d, e, f, g t4 entity type 4x entity parameters: vmax=42.4v, imax=113ma, pi=1w, ci=34.2nf, li=1.134mh authorities intrinsic safety iecex scheme /saa ex ia iic t4 ip66/67 tamb = -40 c to +70 c ex ia iic t5 ip66/67 tamb = -40 c to +50 c entity parameter: ui=28v, ii=93.3ma, pi=0.66w, ci=0.033 f, li=1.034mh tiis ex ia iic t4 tamb max = +60 c entity parameter: ui=28v, ii=94.3ma, pi=0.66w, ci=32.6nf, li=1.134mh csa class i div.1 groups a, b, c, d class ii div.1 groups e, f, g class iii div.1 t emp code t4 tamb max = +40 c t emp code t3c tamb max = +85 c entity parameters: vmax=28v, imax=93ma, ci=27nf (without arrester), ci=34.2nf (with arrester), li=1.4mh model code 9th digit 13th digit t amb a,b,c,d,j y, g , h,s -40 c to +85 c l,p,m,1,2,3 y, g , h,s -20 c to +80 c q,s,n,4,5,6 y, g , h,s -20 c to +60 c e,f,g,h,k y, g , h,s -40 c to +60 c - w,a,d -10 c to +60 c
3 programmable output linearization function: output signal can be characterized with ?4 points linear approximation function from hhc (1) . emc conformity: en61326 vv vv v vv v vv vv vv vv vv vv ? v v vv vv vv vv items display set tag no. model no. serial no. engineering unit range limit measuring range damping linear square root burnout direction calibration output adjust data self diagnoses printer external switch lock transmitter display linearize rerange output mode lower limit of static press. process temperature atmospheric pressure fill fluid 13th digit of ?ode symbols ?20 to 120 c 0 to 250 c ?40 to 120 c 0 to 250 c w, a and d h y and g s fluorinated oil silicone oil 2.7kpa abs {20mmhg abs} ?utput underscale? adjustable within the range 3.2ma to 3.8ma from hhc (1) 3.8 3.2 4 20 20.8 21.6 [ma] over scale burnout probable over range probable under range normal operating range under scale burnout loop-check output: transmitter can be configured to provide constant signal 3.8ma through 21.6ma by hhc (1) . temperature limit: ambient: ?15 to + 65 c (?15 to + 60 c for arrester option) (?10 to + 60 c for fluorinated oil fill transmitter) (?10 to + 60 c for silicone oil ?? ?? for explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits speci- fied in each standard. process: storage: ?40 to +70 c humidity limit: 0 to 100% rh communication: with hhc (1) (model fxw, consult data sheet no. eds8-47), following informa- tion can be remotely displayed or recon- figured. note: hhc? version must be more than 6.0 (or fxw 1 3), for fcx- a 2 . zero/span adjustment : zero and span are adjustable from the hhc (1) . zero and span are also adjustable externally from the adjustment screw (span adjustment is not available with 9th digit code ?, p, m, q , s, n?. damping: adjustable from hhc or local adjustment unit with lcd display. the time constant is adjustable between 0.12 to 32 seconds. zero elevation/suppression: ?00% to +100% of url normal/reverse action: selectable from hhc (1) indication: analog indicator or 5-digit lcd meter, as specified. burnout direction: selectable from hhc (1) if self-diagnostic detect transmitter fail- ure, the analog signal will be driven to ei- ther ?utput hold? ?utput overscale or ?utput underscale?modes. ?utput hold? output signal is hold as the value just be- fore failure happens. ?utput overscale? adjustable within the range 20.8ma to 21.6ma from hhc (1) a tex ex ii 3 gd eex nl iic t5 tamb = -40 c to +40 c eex nl iic t4 tamb = -40 c to +80 c specific parameters: model without arrester: ui=42.4v, ii=113ma, pi=1w, ci=27nf, li=1.134mh model with arrester: ui=32v, ii=113ma, pi=1w, ci=34.2nf, li=1.134mh eex nal iic t5 tamb = -40 c to +40 c eex nal iic t4 tamb = -40 c to +80 c specific parameters: model without arrester: umax=42.4v, imax=113ma, pmax=1w, model with arrester: umax=32v, imax=113ma, pmax=1w factory mutual class i ii iii div.2 groups a, b, c, d, f, g t4 entity type 4x authorities t ype n nonincendive iecex scheme /saa - tiis - csa class i div.2 groups a, b, c, d class ii div.2 groups e, f, g class iii div.2 t emp code t4 tamb max = +40 c t emp code t3c tamb max = +85 c entity parameters: vmax=28v, ci=27nf (without arrester), ci=34.2nf (with arrester), li=1.4mh model code 9th digit 13th digit t amb a,b,c,d,j y, g , h,s -40 c to +85 c l,p,m,1,2,3 y, g , h,s -20 c to +80 c q,s,n,4,5,6 y, g , h,s -20 c to +60 c e,f,g,h,k y, g , h,s -40 c to +60 c - w,a,d -10 c to +60 c
4 fkx ... 4 zero shift: 0.5%/28 c ( x equal to 1 /2 url or more) zero shift; (0.5 )%/28 c ( x less than 1 /2 url) total shift; 0.75%/28 c ( x less than 1 /2 url or more) total shift; (0.25 + 0.5 )%/28 c ( x less than 1 /2 url) (option) (code; 21th digit j,k) zero shift: 0.5%/28 c ( x equal to 1 /6.5 url or more) zero shift; (0.5 )%/28 c ( x less than 1 /6.5 url) total shift; 0.75%/28 c ( x equal to 1 /6.5 url or more) total shift; (0.25 + 0.5 )%/28 c ( x less than 1 /6.5 url) where, x : calibrated span url: maxi mum span (upper range limit) note : above specifications are based on the con- ditions that flanges and sensor unit are at the same temperature and in the same level. if temperature is different at flanges, capillary or sensor unit, output variation may increase. performance specifications reference conditions, silicone oil fill, 316ss isolating diaphragms, 4 to 20ma analog output in linear mode and capillary length 1.5m. accuracy rating: (including linearity, hysteresis, and re- peatability) (standard) for spans greater than 1 /10 of url: 0.25% of span for spans below 1 /10 of url: (option) (code; 21th digit h,k) for spans greater than 1 /10 of url: 0.1% of span for spans below 1 /10 of url: stability: 0.2% of upper range limit (url) for 3 years. temperature effect: effects per 28 c change between the lim- its of ?15 c and +65 c url 2 x url 2 x url 6.5 x url 6.5 x dielectric strength: 500v ac, 50/60hz 1 min., between circuit and earth. insulation resistance: more than 100m ? at 500v dc. turn-on time: 4 sec. internal resistance for external field indicator: 12 ? or less static pressure effect: zero shift; 0.2% of url/1mpa (10 bar) span shift: 0.2% of calibrated span / 1mpa overrange effect: zero shift; 0.1% of url for flange nominal pressure supply voltage effect: less than 0.005% fo calibrated span per 1v rfi effect: less than 0.2% of url for the frequen- cies of 20 to 1000mhz and field strength 30 v/m when electronics covers on. update period: 120 msec * ) step response: (without electrical damping) 0.17+0.08 % of span 0.1 x url span () () 0.05+0.05 % of span 0.1 x url span time constant (*) 1.7 s dead time (*) 0.2 s *) faster response is available as option (maximum update rate: 25 times per second).
5 accessories fig .1 relation between process temperature and operating pressure operating area non-operating area 101 {1010} 53.3 {533} 13.3 {133} 2.7 {27} [kpa abs] {m bar abs} operating pressure ?0 0 60 85 120 200 230 250 process temperature silicone (code y,g) filled liquid: [ c ] silicone (code s) physical specifications electrical connections: g 1 /2 , 1 /2 -14 npt, pg13.5, or m20 x 1.5 con- duit, as specified. and 1-conduit or 2-conduit, as specified. process connections: jis 10k, 20k, 30k - 40, 50a 10k, 20k, 30k - 15, 20a (with adapter) ansi/jpi 150lb, 300lb -1 1 /2 ", 2" 150lb, 300lb - 1 /2 ", 3 /4 " (with adapter) screw connection (with adapter); rc 1 /2 , rc 3 /4 , 1 /2 - 14npt, 3 /4 - 14npt diaphragm extension: 0, 50, 100, 150, or 200mm as specified. (see model code. extended diaphragm is available only with 316l stainless steel diaphragm) process-wetted parts material: diaphragm: 316l stainless steel, hastelloy-c, monel or tantalum flange face: 316 stainless steel, hastelloy- c lining monel lining, or tantalum lining extension: 316 stainless steel non-wetted parts material: electronics housing: low copper die-cast aluminum alloy finished with epoxy/ polyurethane double coating (stan- dard), or 316 stainless steel (scsi4 par jis g5121), as specified. capillary: in case of 11th code ?. e. l.? pvc armored stainless steel. in case of 11th code q . r. s? stain- less steel armored stainless steel. mounting flange: 304 stainless steel or carbon steel. fill fluid: silicone oil (standard) or fluori- nated oil mounting bracket: 304 stainless steel environmental protection: iec ip67 and nema 6/6p mounting: on 60.5mm (jis 50a) pipe using mount- ing bracket, direct wall mounting mass {weight}: transmitter approximately 15kg without options. add; 0.5kg for mounting bracket 0.8kg for indicator option 4.5kg for stainless steel housing option 1.5kg per 50mm extension of diaphragm optional features indicator: a plug-in analog indicator (2.5% accuracy) can be housed in the electronics compart- ment or in the terminal box of the hous- ing. an optional 5-digit lcd meter with engi- neering unit is also available. local adjustment unit with lcd display: an optional 5-digit lcd meter with zero/ span adjustment function, loop-check function and damping adjustment func- tion, is available. arrester: a built-in arrester protects the electronics from lightning surges. lightning surge immunity: 4kv (1.2 x 50 s). oxygen service: special cleaning procedures are followed throughout the process to maintain all pro- cess wetted parts oil-free. the fill fluid is fluorinated oil. chlorine service: oil-free procedures as above. includes fluorinated oil for fill. degreasing: process-wetted parts are cleaned, but the fill fluid is standard silicone oil. not for use on oxygen or chlorine measurement. vacuum service: special silicone oil and filling procedure are applied. see fig. 1. optional tag plate: an extra stainless steel tag for customer tag data is wired to the transmitter. coating of cell: cell's surface is finished with epoxy/poly- urethane double coating. specify if envi- ronment is extremely corrosive. hand-held communicator: (model fxw, refer to data sheet no. eds 8-47) z/s board: parts no.=zzpfcx4-a070 when z/s board is mounted on the fcx a 2 amplifier unit, external adjustment screw will be available for zero and span adjustment.
6 fkx ... 4 g 1 /2 ( 1) 1 /2 - 14npt ( 1) pg13.5 ( 1) m20 1.5 ( 1) g 1 /2 ( 2) 1 /2 - 14npt ( 2) pg13.5 ( 2) m20 1.5 ( 2) material size and rating 304 stainless jis 10k 40a steel jis 10k 50a jis 20k 40a jis 20k 50a jis 30k 40a jis 30k 50a jis 63k 40a jis 63k 50a ansi/jpi 150lb 1 1 /2 " ansi/jpi 150lb 2" ansi/jpi 300lb 1 1 /2 " ansi/jpi 300lb 2" ansi/jpi 600lb 1 1 /2 b ansi/jpi 600lb 2b carbon steel jis 10k 40a jis 10k 50a jis 20k 40a jis 20k 50a jis 30k 40a jis 30k 50a jis 63k 40a jis 63k 50a ansi/jpi 150lb 1 1 /2 " ansi/jpi 150lb 2" ansi/jpi 300lb 1 1 /2 " ansi/jpi 300lb 2" ansi/jpi 600lb 1 1 /2 b ansi/jpi 600lb 2b none 40a, 1 1 /2 b (wafer type) 50a, 2b direct mounting adapter connection (* 1) 3........32(30...320) 13......130(130...1300) 50......500(500...5000) diaphragm 316l stainless steel 316l stainless steel +au coating hastelloy-c monel tantalum description note note 1 note 2 note 3 digit 4 5 6 7 4567 123 f4 kx 89 10 16 18 20 21 14 15 17 11 12 13 19 digit no. of code a b c d s t v w 0 1 2 3 4 5 6 7 a b c d e f g h j k l m n p q r s t u v w x y 3 5 6 v a b c d j h m t flange face 316 stainless steel hastelloy-c monel tantalum diaphragm extension(mm) 0 50 100 150 200 0 0 0 0 (*3) note 1: (*1) direct mounting adapter type is specified at 16th to 20th digit. direct mounting adapter is available only for 7th digit code "v". note 2: (*2) 100:1 turn down is possible for model fkx, but should be used within indicated span for better performance. note 3: (*3) diaphragm extension is available only for 2" (50a) flanges. combination with 12th digit code "c, e, p, q "are not available. (*2) code symbols
7 indicator arrester none none analog, 0 to 100% linear scale none analog, 0 to 100% sq. root scale none analog, custom scale none analog, double scale(linear and sq.root) none none yes analog, 0 to 100% linear scale yes analog, 0 to 100% sq. root scale yes analog, custom scale yes analog, double scale(linear and sq.root) yes digital, 0 to 100% none digital, custom scale none digital, 0 to 100% square root none digital, 0 to 100% yes digital, custom scale yes digital, 0 to 100% square root yes digital, 0 to 100% (local adjustment unit with lcd display) none digital, custom scale (local adjustment unit with lcd display) none digital, 0 to 100% square root (local adjustment unit with lcd display) none digital, 0 to 100% (local adjustment unit with lcd display) yes digital, custom scale (local adjustment unit with lcd display) yes digital, 0 to 100% square root (local adjustment unit with lcd display) yes none (for ordinary locations) tiis, flameproof (conduit seal) (available for 4th digit code "a", "s") tiis, flameproof (cable gland seal) (available for 4th digit code "a", "s") fm, flameproof (or explosionproof) (available for 4th digit code "b", "t") atex, flameproof iecex scheme/saa, flameproof (approval pending) tiis, intrinsic safety fm, intrinsic safety and nonincendive atex, intrinsic safety atex, type n iecex scheme/saa, intrinsic safety fm, combined of flameproof and intrinsic safety mounting bracket capillary armor of capillary stainless steel 1.5m pvc 3m 5m 1.5m stainless steel 3m 5m extra ss tag plate stainless steel elec. housing coating of cell none none none yes none none none yes none yes yes none none none yes yes none yes none yes yes yes yes yes treatment fill fluid standard silicone oil (for general use) standard fluorinated oil degreasing silicone oil oxygen service fluorinated oil (7th digit code "v", "a", "b", "c" and "d") chlorine service fluorinated oil (7th digit code "h" and "t") high temp. 250 c silicone oil (7th digit code "v", "a", "b", "c", "d" and "h") high temp. and vacuum (250 c) silicone oil (7th digit code "v", "a", "b", "c" and "d") none yes (available for 7th digit code "v", "h", "m" and "t". not available for 5th digit code "y" and 13th digit code "h", "s".) description note note5 note4 digit 9 10 11 12 13 14 4567 123 f4 kx 8 0 9 10 16 18 20 14 15 17 11 12 13 19 21 digit no. of code y b c e m n p q d e l q r s y w g a d h s y c note 4: (*4) customer tag number can be engraved on standard stainless steel name plate. if extra tag plate is required, select "yes". note 5: (*5) available for 13th digit code "y", "w", "g", "a" and "d". (*4) (*5) a b c d x r g h k p t v a b c d j e f g h k l p m q s n 1 2 3 4 5 6 z/s board attached.
8 fkx ... 4 jis 10k 15a jis 10k 20a jis 20k 15a jis 20k 20a jis 30k 15a jis 30k 20a ansi/jpi 150lb 1 /2 " ansi/jpi 150lb 3 /4 " ansi/jpi 300lb 1 /2 " ansi/jpi 300lb 3 /4 " screw connection rc 1 /2 screw connection rc 3 /4 screw connection rc 1 /2 - 14npt screw connection rc 3 /4 - 14npt (*6) adapter bolts/nuts (* 6) 316 stainless steel cr-mo steel/carbon steel standard long type standard (teflon) (only y, w, g, a and d can be specified on 13th digit). for high temperature (spiral gasket) (only h and s can be specified on 13th digit). (*7) high accuracy type instruction manual attached low temperature effect type instruction manual attached h+j instruction manual attached instruction manual unattached high accuracy type instruction manual unattached low temperature effect type instruction manual unattached t+u instruction manual unattached description note note 6 note 7 digit 16, 17 18 19 20 21 4567 123 f4 0 kx 89 10 16 18 20 14 15 17 11 12 13 19 21 digit no. of code 1 1 2 2 3 3 1 1 2 2 s s s s 1 2 1 2 1 2 h t h t r 2 n t w a n 1 2 note 6: (*6) for connection of transmitter receiving pressure unit and direct mounting adapter note 7: (*7) if other option is not necessary, 21st digit code is blank. in case of 21st digit code is blank, instruction manual attached. h j k l t u v specifications of direct mounting adapter {for 15, 20a ( 1 /2 , 3 /4 ") connection} and others note 1. when odering the instrument with direct mounting adapter, specify ??in the 5th digit of code symbol, and specify 16th digit to 20th digit. when odering the instrument without direct mounting adapter, nothing should be filled in the 16th to 20th digit. 2. unless otherwise described in the specifications, leave the 21st digit blank.
9 ordering information when ordering this instrument, specify: 1. code symbols 2. measuring range 3. output orientation (burnout direction) when abnormality is occurred in the transmitter. hold / overscale (21.6ma) / underscale (3.2ma) unless otherwise specified, output hold function is supplied. 4. output mode (linear or square root output) unless otherwise specified, output mode is linear. 5. indication method (indicated value and unit) in case of the actual scale (code d, h, p, s on 9th digit). 6. tag no. (up to 26 alphanumerical characters), if required. the product conforms to the requirements of the electromagnetic compatibility directive 94/9/ec as detailed within the technical construction file number tn513035. the applicable standards used to demonstrate compliance are : frequency range mhz limits reference standard 30 to 230 40db ( v/m) quasi peak, measured at 10m distance 230 to 1000 47db ( v/m) quasi peak, measured at 10m distance cispr16-1 and cispr16-2 phenomenon test value basic standard performance criteria b electrostatic discharge conducted rf 0.15 to 80mhz 3v 80%am (1khz) electromagnetic field 4kv (contact) 8kv (air) 80 to 1000mhz 10v/m 80%am (1khz) en61000-4-2 burst a en61000-4-3 rated power frequency magnetic field 30a/m 50hz a en61000-4-8 2kv 5khz b en61000-4-4 surge 1.2 s/50 s 1kv (line to line) 2kv (line to ground) b en61000-4-5 a en61000-4-6 emi (emission) en61326 : 1997 class a (standard for industrial location) emi (immunity) en61326: 1997 annex a (standard for industrial location) note) definition of performance criteria a: during testing, normal performance within the specification limits. b: during testing, temporary degradation, or loss of function or performance which is self-recovering.
10 fkx ... 4 outline diagram (unit:mm) 5th digit of code symbols 0, g 140 36 4-19 jis-10k-40a 105 1, h 155 36 4-19 jis-10k-50a 120 2, j 140 38 4-19 jis-20k-40a 105 3, k 155 38 8-19 jis-20k-50a 120 4, l 160 42 4-23 jis-30k-40a 120 5, m 6, n 7, p 165 42 8-19 jis-30k-50a jis-63k-40a jis-63k-50a 130 a, q 175 52 4-25 130 b, r 185 54 8-23 145 c, s 127 37.5 4-16 ansi/jpi-150lb-1 1/2b 98.4 d, t e, u f, v 152 39.5 4-20 ansi/jpi-150lb-2b 120.6 ? ? t n-? (flange) 156 41 4-23 ansi/jpi-300lb-1 1/2b 114.3 165 42.5 8-20 ansi/jpi-300lb-2b 127 156 42.5 4-23 ansi/jpi-600lb-1 1/2b 114.3 165 45.5 8-20 ansi/jpi-600lb-2b 127 4th digit of the code symbols conduit conn. 11th digit of code symbols capillary length [mm] d, q 1500 e, r 3000 l, s 5000 jkm g1/2 17 8 3, 4, a, s 1/2-14npt 16 5 b, t pg13.5 8 4.5 c, v m20 1.5 16 5 d, w table 1 7th digit of code symbols l mass approx. [kg] v, h, m, t, j 0 14 to 19.5 a 50 15 to 30.5 b 100 15.5 to 31 c 150 16 to 31.5 d 200 16.5 to 32 ck ck note : in case of wafer type, flange is excluded from the scope of supply. mount flange, referring to the view. note) cable gland is supplied in case of flameproof packing type. ?1 cable is suitable. connection diagram inner of gasket 105 104 105 ?0 70 8 10 88 71 222 ?0 52.5 94.5 ?8 km 17 75 ?9 ?4 ? ? 38 58 201 20 270 48 43 70 2-m8 12 l.p. ss h.p. 120 62 lt (27) 28 see table 1 j ?5 ?/2 20 ?3 71 ?9 ?4 20 mtg. pipe jis 50a (2b) u-bolt m8 zero adj. screw 4 holes 9 dia. "a" conduit conn. with field ind. fastene (flameproof only) note) cable gland (option) "b" conduit conn. n holes h dia. no flange is attached in case of 5th digit code w, x" earth terminal detail "a" detail "b" 2-m6 screw depth 9 inner of gasket in case of 4th digit code "t" in case of 4th digit code "a.b.c.d.e" in case of 4th digit code "s.v.w.x" up down electronics unit sensor unit
11 4th digit of the code symbols conduit conn. 11th digit of code symbols capillary length [mm] d, q 1500 e, r 3000 l, s 5000 table 1 jkm g1/2 17 8 3, 4, a, s 1/2-14npt 16 5 b, t pg13.5 84.5 c, v 16 5 d, w m20 1.5 16th digit of code symbols 17th digit of code symbols 1 95 12 4-15 jis-10k-15a 70 2 100 14 4-15 jis-10k-20a 75 1 95 14 4-15 jis-20k-15a 70 2 100 16 4-15 jis-20k-20a 75 1 115 18 4-19 jis-30k-15a 80 2 120 18 4-19 jis-30k-20a 85 h 89 11.5 4-16 ansi/jpi-150lb 1/2b 60.3 t 98 13 4-16 ansi/jpi-150lb 3/4b 69.9 h 95 14.5 4-16 ansi/jpi-300lb 1/2b 66.7 t 117 16 4-20 ansi/jpi-300lb 3/4b 82.5 1 1 2 2 3 3 1 1 2 2 ? 51 56 51 56 55 60 34.9 42.9 34.9 42.9 ? ? t n-? flange ck ck electronics unit sensor unit 2-m8 12 connection diagram km 17 j ?5 ?/2 ?3 detail "a" detail "b" (102) 25 70 105 104 52.5 88 ?0 8 ?4 ? ? ? t 20 38 58 270 70 120 62 48 43 201 (27) 28 80 s ?0 222 long vent/drain plug (option) vent/drain plug mtg. pipe jis 50a(2b) u-bolt m8 zero adj. screw l. p. h. p. 4 holes 9 dia. "a" conduit conn. with field ind. fastener (flameproof only) cable gland (option) "b" conduit conn. earth terminal n holes, h dia. 105 10 94.5 in case of 4th digit code "t" in case of 4th digit code "a.b.c.d.e" in case of 4th digit code "s.v.w.x" up down note) cable gland is supplied in case of flameproof packing type. ?1 cable is suitable. note)
fkx ... 4 4th digit of the code symbols conduit conn. note) cable gland is supplied in case of flameproof packing type. ?1 cable is suitable. 16th digit of code symbols 17th digit of code symbols press. conn."d" srrc 1/2 sn 1/2-14npt s2rc 3/4 st 3/4-14npt 11th digit of code symbols capillary length [mm] d, q 1500 e, r 3000 l, s 5000 table 1 jkm g1/2 17 8 a, s 1/2-14npt 16 5 b, t pg13.5 8 4.5 c, v m20 1.5 16 5 d, w ck ck k 17 m ?5 j ?3 g1/2 connection diagram detail "a" detail "b" low press. conn. d" high press. conn. "d" (102) 25 ?4 70 105 104 ?0 ?0 52.5 94.5 88 8 s 20 38 58 201 (27) 28 23 222 270 48 43 70 120 62 long vent/drain plug (option) vent/drain plug mtg. pipe jis 50a (2b) u-bolt m8 zero adj. screw "a" conduit conn. with field ind. cable gland (option) "b" conduit conn fastener (flameproof only) earth termina 4 holes 9 dia. in case of 4th digit code "t" in case of 4th digit code "a.b.c.d.e" 105 10 in case of 4th digit code "s.v.w.x" up down note) 2-m8 12 electronics unit sensor unit information in this catalog is subject to change without notice. printed in japan head office gate city ohsaki, east tower, 11-2, osaki 1-chome, shinagawa-ku, tokyo 141-0032, japan http://www.fesys.co.jp/eng instrumentation div. international sales dept. no.1, fuji-machi, hino-city, tokyo, 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187 http://www.fic-net.jp/eng caution on safety *before using this product, be sure to read its instruction manual in advance.


▲Up To Search▲   

 
Price & Availability of EDSX6-116K

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X