  fcx ?ax series differential pressure transmitter small flange remote seal type date data sheet mar. 10, 1999 specifications features up tp flange rating the fcx ?x series small flange remote seal type differential pressure transmitter accurately measures differential pressure, liquid level or gauge pressure and transmits a proportional 4 to 20ma signal. the trans-mitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and functionality. totally welded construction of the seals assures excellent reliability in high temperature and highly corrosive process conditions. EDSX6-103 1. directly connectable to 1-1/2in and 2in flanges the transmitter is connectable to 1-1/2in and 2in pipes without a reducer. 2. flow measurement without impulse piping 1/2in and 3/4in flange size is also available. this differ- ential pressure transmitter allows connection to 1/2in and 3/4in flanges of a general size for the orifice tap, which eliminates the need of using a impulse piping. problems with the impulse piping, such as clogging, leaks or corrosion can be solved. in addition, the following process connection is also available. screw connection 1/2-14npt, 3/4-14npt, rc1/2, rc3/4 3. minimum environmental influence the "advanced floating cell" design which protects the pressure sensor against changes in temperature, static pressure, and overpressure substantially reduces total measurement error in actual field applications. 4. replaceable communication module fuji micro-electronics manufacturing technology offers replaceable communication module that makes fcx?x transmitter very unique in design. in case of change in communication protocl all that needs to be done is just replace the module and the transmitter gets upgraded to the new version. 5. fuji/hart bilingual communication module the communication module is "bilingual" to speak both fuji proprietary protocol and hart. any hart compatible devices can communicate with fcx?x series trans- mitters. 6. application flexibility various options that render the fcx?x suitable for almost any process applications include: analog indicator at either the electronics side or terminal side full range of hazardous area approvals built-in rfi filter and lightning arrester ? 1 / 2 -digits lcd meter stainless steel electronics housing wide selection of materials high temperature, high vacuum seals f x 5 f x 6 +/ 130 { +/ 1300 } +/ 500 { +/ 5000 } 13 { 130 } 50 { 500 } 3 { 30} 12.5 { 125} 130 { 1300 } 500 { 5000 } min. fhx fkx type range limit [kpa] {m bar} span limit [kpa] (m bar} functional specifications type: model fhx: 4 to 20ma model fkx: 4 to 20ma with digital signal service: liquid, gas, or vapour static pressure, span, and range limit: max. fhx/fkx static pressure maximum static pressure limit for screw connction type: 4.2mpa } 7. programmable output linearization function in addition to linear and square root, output signal can be freely programmable. (up to 14 compensated points at approximation.) (available for amplifier unit from version 24 and fxw(hhc) version 5.3.) 8. burnout current flexibility (under scale: 3.2 to 3.8ma, over scale: 20.8 to 21.6ma) burnout signal level is adjustable using model fxw hand held communicator (hhc) to comply with namur ne43. (available for amplifier unit from version 24 and fxw (hhc) version 5.3.) 9. dry calibration without reference pressure thanks to the best combination of unique construction of mechanical parts (sensor unit) and high performance electronics circuit (electronics unit), reliability of dry cali- bration without reference pressure is at equal level as wet calibration. fhx, fkx ... 3
2 fhx, fkx ... 3 power supply: transmitter operates on 10.5v to 45v dc at transmitter terminals. 10.5v to 32v dc for the units with optional arrester. load limitations: see figure below note: for communication with hhc (model: fxw), min. of 250 ? required. hazardous locations: (approval pending) baseefa ex ds iic t5, t6 eex ia iic t4, t5 ex n ii t5 factory class i ii iii class i ii iii class i ii iii mutual div. 1 div. 1 div. 2 groups b thru. g groups a thru. f groups a thru. g riis exds iib + h 2 t4 type n nonincendive authorities flameproof intrinsic safety lower limit of static press. process temperature atmospheric pressure fill fluid 13th digit of "code symbols" ?20 to 120 c 0 to 250 c ?40 to 120 c 0 to 250 c w, a and d h y and g s fluorinated oil silicone oil 2.7kpa abs {20mmhg abs} zero/span adjustment : model fhx: zero is adjustable from the external ad- justment screw. the adjustment screw can also function to adjust span when mode switch (lo- cated on the electronics unit) is in the span mode. inhibit mode to disable the ad- justment screw is also available. model fkx: zero and span are adjustable from the hhc. zero is also adjustable externally from the adjustment screw. damping: adjustable electrical damping. model fhx: the time constant is adjustable to 0, 0.3, 1.2, 4.8, or 19.2 seconds. model fkx: the time constant is adjustable between 0 to 38.4 seconds. zero elevation/suppression: ?00% to +100% of url 2000 [ ? ] 1500 1000 load resistance 500 250 1533 ? 600 ? operating area 24v 45v 10 16.1 50 [ v ] 10.5v power voltage lower limit of static pressure (vacuum limit), silicone fill sensor: see fig. 1 fluorinated fill sensor: atmospheric pressure the maximum span of each sensor can be converted to different units using factors as below. 1mpa=10 3 kpa=10bar=10.19716kgf/cm 2 = 145.0377psi 1kpa=10mbar=101.976mmh 2 o=4.01463h 2 o overrage limit: to maximum static pressure limit output signal: model fhx: 4 to 20ma dc 2-wire, linear signal model fkx: 4 to 20ma dc (linear or square root) with digital signal superimposed on the 4 to 20ma signal normal/reverse action: model fhx: selectable by moving a jumper pin located on the electronics unit. model fkx: selectable from hhc indication: analog indicator or 4 1 / 2 digit lcd meter, as specified. burnout direction: if self-diagnostic detect transmitter fail- ure, the analog signal will be driven to ei- ther ?utput hold? ?utput overscale or ?utput underscale?modes. model fhx: unless otherwise specified in the order, the transmitter will be shipped in ?utput hold?mode. (output signal just before failure happens is maintained.) model fkx: selectable from hhc ?utput hold? output signal is hold as the value just be- fore failure happens. ?utput overscale? approx. 21.6ma (adjustable within the range 20.8ma to 21.6ma from hhc) ?utput underscale? approx. 3.8ma (adjustable within the range 3.2ma to 3.8ma from hhc) 0 3.8 3.2 4 20 20.8 21.6 over scale burnout probable over range probable under range normal operating range under scale burnout loop-check output: model fhx: transmitter can output constant signal of 4ma, 12ma, or 20ma if mode switch is set to the loop check mode. model fkx: transmitter can be configured to provide constant signal 3.8ma through 21.6ma by hhc. temperature limit: ambient: ?15 to + 65 c (?15 to + 60 c for arrester option) (?10 to + 60 c for fluorinated oil fill transmitter) (?10 to + 60 c for silicone oil "h", "s") for explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits speci- fied in each standard. process: storage: ?40 to +70 c humidity limit: 0 to 100% rh
3 zero shift: 0.5%/28 c ( x equal to 1/2 url or more) zero shift; (0.5 )%/28 c ( x less than 1/2 url) total shift; 0.75%/28 c ( x less than 1/2 url or more) total shift; (0.25 + 0.5 )%/28 c ( x less than 1/2 url) high performance type (option) zero shift: 0.5%/28 c ( x equal to 1/6.5 url or more) zero shift; (0.5 )%/28 c ( x less than 1/6.5 url) total shift; 0.75%/28 c (x equal to 1/6.5 url or more) total shift; (0.25 + 0.5 )%/28 c ( x less than 1/6.5 url) where, x : calibrated span url: maximum span (upper range limit) note 1: condition: capillary length: 3m max. in case the capillary length is 5m, the performance becomes 1.5 times worse than above. note 2: in case the 7th code (material code) is other than w, a, b, c or d, the perfor- mance becomes 2.5 times worse than above. note 3: above specifications are based on the con- ditions that flanges and sensor unit are at the same temperature and in the same level. if temperature is different at flanges, capillary or sensor unit, output variation may increase. () performance specifications accuracy rating: (including linearity, hysteresis, and re- (standard) peatability) for spans greater than 1/10 of url: 0.25% of span for spans below 1/10 of url (model fkx only): (option) for spans greater than 1/10 of url: 0.1% of span for spans below 1/10 of url (model fkx only): linearity: 0.1% of calibrated span stability: 0.2% of upper range limit (url) for 24 months temperature effect: effects per 28 c change between the lim- its of ?15 c and +65 c 0.17+0.08 % of span 0.1 x url span () url 2 x x url 2 x x url 6.5 x x url 6.5 x x 0.05+0.05 % of span 0.1 x url span vv vv v vv v vv vv vv vv vv ? v v vv vv vv vv items display set tag no. model no. serial no. engineering unit range limit measuring range damping output mode burnout direction adjustment output adjust data self diagnoses printer external switch lock transmitter display(*) linearise (**) rerange (**) notes:(*) hhc's version must be more than 5.0 (or fxw 1 2), to use this function. (**) hhc's version must be more than 5.3, and amplifier unit version 24. communication: (model fkx only) with hhc (model fxw, consult data sheet no. eds8-47), following informa- tion can be remotely displayed or recon- figured. programmable output linearization function: in smart version, output signal can be characterized with ?4 points linear ap- proximation function?from hhc.
4 fhx, fkx ... 3 physical specifications electrical connections: g1/2, 1/2-14 npt, pg13.5, or m20 x 1.5 conduit, as specified. process connections: jis 10k, 20k, 30k - 40, 50a 10k, 20k, 30k - 15, 20a (with adapter) ansi/jpi 150lb, 300lb -1 1 / 2 ", 2" 150lb, 300lb - 1/2", 3/4" (with adapter) screw connection (with adapter); rc1/2, rc3/4, 1/2 - 14npt, 3/4 - 14npt diaphragm extension: 0, 50, 100, 150, or 200mm as specified. (see model code. extended diaphragm is available only with 316l stainless steel diaphragm) process-wetted parts material: diaphragm: 316l stainless steel, hastelloy-c, monel or tantalum flange face: 316 stainless steel, hastelloy- c lining monel lining, or tantalum lining extension: 316 stainless steel non-wetted parts material: electronics housing: low copper die-cast aluminum alloy (standard), finished with polyester coating, or 316 stainless steel (scsi4 par jis g51), as specified. capillary: in case of 13th code "y. w. g. a. d", pvc armored stainless steel. in case of 13th code "h. s", stainless steel armored stainless steel. mounting flange: (option) 304 stainless steel or carbon steel fill fluid: silicone oil (standard) or fluori- nated oil (daifloil) mounting bracket: carbon steel with ep- oxy coating or 304stainless steel, as specified environmental protection: iec ip67 and nema 4x mounting: on 60.5mm (jis 50a) pipe using mount- ing bracket, direct wall mounting mass {weight}: transmitter approximately 15kg without options. add; 0.5kg for mounting bracket 0.8kg for indicator option 4.5kg for stainless steel housing option 1.5kg per 50mm extension of diaphragm dielectric strength: 500v ac, 50/60hz 1 min., between circuit and earth. insulation resistance: more than 100m ? /500v dc. turn-on time: 4 sec. internal resistance for external field indicator: 12 ? or less time constant (*) 1.7 s dead time approx. 0.3 s note: * capillary length: 1.5m, ambient tem- perature: 23 c static pressure effect: zero shift; 0.2% of url/1mpa (10 bar) 2.5 times the zero shift for material code, "h", "m" and "t" span shift: ?0.2 % of calibrated span for flange nominal pressure overrange effect: zero shift; 0.3% of url for flange nominal pressure 2.5 times the effects for material code. "h", "m" and "t" supply voltage effect: less than 0.05% fo calibrated span per 10v rfi effect: less than 0.2% of url for the frequen- cies of 20 to 1000mhz and field strength 30 v/m when electronics covers on. step response: (without electrical damping) +0.2 ?.1
5 accessories fig. 1 relation between process temperature and operating pressure operating area non-operating area 101 {1010} 53.3 {533} 13.3 {133} 2.7 {27} [kpa abs] {m bar abs} operating pressure ?0 0 60 85 120 200 230 250 process temperature silicone (code y,g) filled liquid: [ c ] silicone (code s) optional features indicator: a plug-in analog indicator (1.5% accuracy) can be housed in the electronics compart- ment or in the terminal box of the hous- ing. an optional 4 1 / 2 digits lcd meter is also available. arrester: a built-in arrester protects the electronics from lightning surges. lighting surge immunity is 4kv (1.2 x 50 s). oxygen service: special cleaning procedures are followed throughout the process to maintain all pro- cess wetted parts oil-free. the fill fluid is fluorinated oil. chlorine service: oil-free procedures as above. includes fluorinated oil for fill. degreasing: process-wetted parts are cleaned, but the fill fluid is standard silicone oil. not for use on oxygen or chlorine measurement. vacuum service: special silicone oil and filling procedure are applied. see below figure. customer tag: a stainless steel tag for customer tag data is wired to the transmitter. coating of cell: cell's surface is finished with epoxy/poly- urethane double coating. specify if envi- ronment is extremely corrosive. hand-held communicator: (model fxw, refer to data sheet no. eds 8-47) communication module: (standard for model fkx) by adding communication module, re- mote setting function becomes available for model fhx. remark: when the communication module is con- nected, the operation mode of external zero/span adjustment screw is limited to zero adjustment only.
6 fhx, fkx ... 3 12345678 910111213 14151617181920 description type 4 to 20ma, output type 4 to 20ma with digital signal, output type conduit connection <4th digit> g 1/2 1/2 - 14npt pg 13.5 m20 x 1.5 30 fx fhx fkx s t v w flange <5th digit> material size and rating 304 stainless jis 10k 40a steel jis 10k 50a jis 20k 40a jis 20k 50a jis 30k 40a jis 30k 50a ansi/jpi 150lb 1 1 / 2 " ansi/jpi 150lb 2" ansi/jpi 300lb 1 1 / 2 " ansi/jpi 300lb 2" carbon steel jis 10k 40a jis 10k 50a jis 20k 40a jis 20k 50a jis 30k 40a jis 30k 50a ansi/jpi 150lb 1 1 / 2 " ansi/jpi 150lb 2" ansi/jpi 300lb 1 1 / 2 " ansi/jpi 300lb 2" none 40a, 1 1 / 2 b (wafer type) 50a, 2b direct mounting adapter connection (* 1) span limit [kpa] {m bar} <6th digit> fhx fkx 13 ... 130 (130 ... 1300) 3 ... 130 ( 30 ... 1300) 50 ... 500 (500 ... 5000) 12.5 ... 500 (125 ... 5000) 0 1 2 3 4 5 a b c d g h j k l m q r s t w x y 5 6 w a b c d h m t note 1: direct mounting adapter type is specified at 16th to 20th digit. direct mounting adapter is available only for 7th digit code "w". 2: diaphragm extension is available only for 2" (50a) flanges. ? ? ? material/diapharagm extension <7th digit> diaphragm 316l stainless steel hastelloy-c monel tantalum flange face 316 stainless steel hastelloy-c monel tantalum diaphragm extension (mm) 0 50 100 150 200 0 0 0 (* 2 ) code symbols
7 odering information 1. when odering this instrument, specify the output orientation (burnout direction) in case of abnormality in the transmitter. unless otherwise specified, the output hold function is supplied. 2. when odering fkx, specify the output mode (linear or square root output). unless otherwise specified, linear output is supplied. 3. when specifying the digital indicator/actual scale (codes p and s on 9th digit), specify the method indication (indicated value and unit). description } a b c d m n h k p y b c e m n p q a b g d e l y w g a d h s a b c d j e f g h k l p m q s n y c indicator and arrester <9th digit> indicator arrester none none analog, 0 to 100% linear scale none analog, 0 to 100% sq. root scale none analog, custom scale none analog, double scale none none yes analog, 0 to 100% linear scale yes analog, 0 to 100% sq. root scale yes analog, custom scale yes analog, double scale yes digital, 0 to 100% none digital, custom scale none (model fkx only) digital, 0 to 100% square root none digital, 0 to 100% yes digital, custom scale yes (model fkx only) digital, 0 to 100% square root yes approvals for hazardous locations <10th digit> (approval pending) none (for ordinary locations) jis, flameproof (conduit seal) (available for 4th digit code "s") jis, flameproof (cable gland seal) (available for 4th digit code "s") fm, flameproof (or explosionproof) (available for 4th digit code "t") baseefa, flameproof (conduit seal) baseefa, flameproof (cable gland seal) (conduit connection g 1/2 only) fm, intrinsic safety and nonincendive cenelec, intrinsic safety cenelec, intrinsic safety and baseefa, type n capillary and mounting bracket <11th digit> mounting bracket capillary carbon steel 1.5m 3m 5m stainless steel 1.5m 3m 5m stainless steel parts <12th digit> stainless steel tag plate stainless steel elec. housing coating of cell none none none yes none none none yes none yes yes none none none yes yes none yes none yes yes yes yes yes treatment/fill fluid <13th digit> treatment fill fluid none silicone oil (for general use) none fluorinated oil degreasing silicone oil oxygen service fluorinated oil (7th digit code "w", "a", "b", "c" and "d") chlorine service fluorinated oil (7th digit code "h" and "t") high temp. 250 c silicone oil high temp. and vacuum (250 c) silicone oil teflon membrane <14th digit> none yes (7th digit code "w", "h", "m", and "t") 12345678 910111213 141516171819 20 3 fx (7th digit code "w", "a", "b", "c" and "d")
8 fhx, fkx ... 3 12345678 910111213 14151617181920 process connection (direct mounting adapter) <16th to 17 digit> jis 10k 15a jis 10k 20a jis 20k 15a jis 20k 20a jis 30k 15a jis 30k 20a ansi/jpi 150lb 1/2" ansi/jpi 150lb 3/4" ansi/jpi 300lb 1/2" ansi/jpi 300lb 3/4" screw connection rc1/2 screw connection rc3/4 screw connection rc1/2 - 14npt screw connection rc3/4 - 14npt material (direct mounting adapter) <18th digit> adapter bolts/nuts (* 1) 316 stainless steel cr-mo steel/carbon steel vent/drain (for direct mounting adapter) <19 th digit> standard long type gasket (for direct mounting adapter) <20th digit> standard (teflon) (only y, w, g, a and d can be specified on 13th digit). for high temperature (spiral gasket) (only h and s can be specified on 13th digit). note 1 for connection of transmitter receiving pressure unit and direct mounting adapter description 30 fx 1 1 2 2 3 3 1 1 2 2 s s s s 1 2 1 2 1 2 h t h t r 2 n t w g n 1 2 specifications of direct mounting adapter {for 15, 20a (1/2, 3/4") connection} and others note 1. when odering the instrument with direct mounting adapter, specify "y" in the 5th digit of code symbol, and specify 16th digit to 20th digits. when odering the instrument without direct mounting adapter, nothing should be filled in the 16th to 20th digits. 2. unless otherwise described in the specifications, leave the 21st digit blank.
9 jis-10k-40a jis-10k-50a jis-20k-40a jis-20k-50a jis-30k-40a jis-30k-50a ansi/jpi-150lb-1 1/2" ansi/jpi-150lb-2" ansi/jpi-300lb-1 1/2" ansi/jpi-300lb-2" outline diagram (unit:mm) 7th digit of code symbols w, h, m, t a b c d l 0 50 100 150 200 14 to 19.5 15 to 30.5 15.5 to 31 16 to 31.5 16.5 to 32 mass approx. [kg] d 140 155 140 155 160 165 127 152 156 165 e 105 120 105 120 120 130 98.4 120.6 114.3 127 5th digit of code symbols 0, g 1, h 2, j 3, k 4, l 5, m a, q b, r c, s d, t t 36 36 38 38 42 42 37.5 39.5 41 42.5 n- h 4-19 4-19 4-19 8-19 4-23 8-19 4-16 4-20 4-23 8-20 flange conduit conn. 4th digit of code symbols s t v w table 1 j g1/2 1/2-14npt pg13.5 m20x1.5 k 17 16 8 16 m 8 5 4.5 5 no. 8-32unc m4 m4 m4 earth terminal note *: cable gland is supplied in case of flameproof packing type. ?1 cable is suitable. 75 20 11th digit of code symbols a,d b, e g, l capillary length s [mm] 1500 3000 5000 h k f x s t v w connection diagram + + ck + ck 3 84 49 20 2-m6 screw depth 9 inner of gasket 71 note: in case of water type, flange is excluded from the scope of supply. mount flange, referring to the view. 13 j k m 15 g1/2 17 see table 1 270 120 70 detail "a" (conduit conn.) detail "b" 261 s s h.p. l.p. 48 84 l 20 t e d 38 28 58 233 mtg. pipe jis 50a (2") u - bolt m8 2-m8 x 12 70 4 holes 9 dia. 49 inner of gasket 62 up down 71 n holes h dia. in case of 4th digit code "s,v,w,x" cable ground (option) see note "b" conduit. conn. 110 50 88 "a" conduit conn. fastener (in case of 10th digit code "b,c,m,n") 104 zero/span adj. screw 80 with field ind. (option) earth terminal (both side) see table 1 51 71 (27) 80
10 fhx, fkx ... 3 outline diagram (unit:mm) table 1 11th digit of code symbols a,d b, e g, l capillary length s [mm] 1500 3000 5000 h k f x s t v w 3 y 1 2 3 conduit conn. 4th digit of code symbols s t v w j g1/2 1/2-14npt pg13.5 m20x1.5 k 17 16 8 16 m 8 5 4.5 5 no. 8-32unc m4 m4 m4 earth terminal 13 j k m 15 g1/2 17 see table 1 270 + ck+ck + conection diagram 120 70 detail "a" (conduit conn.) detail "b" 261 38 28 58 233 mtg. pipe jis 50a (2") u - bolt m8 2-m8 x 12 70 4 holes 9 dia. 62 up down n holes h dia. in case of 4th digit code "s,v,w,x" cable ground (option) see note "b" conduit conn. 110 50 88 "a" conduit conn. fastener (in case of digit code b,c,m,n") 104 zero/span adj. screw 80 with field ind. (option) 51 71 (27) 80 long vent/drain plug (added specification) vent/drain plug (102) 25 f e d 84 t 80 20 s specifications for instrument with direct mounting adapter earth terminal (both side) see table 1 16th digit of code symbols 1 1 2 2 3 3 1 1 2 2 n- h 4-15 4-15 4-15 4-15 4-19 4-19 4-16 4-16 4-16 4-20 17th digit of code symbols 1 2 1 2 1 2 h t h t d 95 100 95 100 115 120 89 98 95 117 e 70 75 70 75 80 85 60.3 69.9 66.7 82.5 -f 51 56 51 56 55 60 34.9 42.9 34.9 42.9 t 12 14 14 16 18 18 11.5 13 14.5 16 note *: cable gland is supplied in case of flameproof packing type. ?1 cable is suitable. flange jis-10k-15a jis-10k-20a jis-20k-15a jis-20k-20a jis-30k-15a jis-30k-20a ansi/jpi-150lb - 1/2" ansi/jpi-150lb - 3/4" ansi/jpi-300lb - 1/2" ansi/jpi-300lb - 3/4"
11 4th digit of code symbols s t v w table 1 11th digit of code symbols a,d b, e g, l capillary length s [mm] 1500 3000 5000 16th digit of code symbols s s s s press. conn. "d" note *: cable gland is supplied in case of flameproof packing type. ?1 cable is suitable. h k f x s t v w 3 y s conduit conn. j g1/2 1/2-14npt pg13.5 m20x1.5 k 17 16 8 16 m 8 5 4.5 5 no. 8-32unc m4 m4 m4 earth terminal 17th digit of code symbols r n 2 t rc 1/2 1/2 - 14npt rc 3/4 3/4 - 14npt 13 j k m 15 g1/2 17 see table 1 270 ck+ ck connection diagram 120 70 detail "a" (conduit conn.) detail "b" 261 38 28 58 233 mtg. pipe jis 50a (2") u - bolt m8 2-m8 x 12 70 4 holes 9 dia. 62 up down in case of 4th digit code "s,v,w,x" cable gland (option) see note "b" conduit conn. 110 50 88 "a" conduit conn. fastener (in case of 10th digit code b,c,m,n") 104 zero/span adj. acrew 80 withh field ind. (option) earth terminal (both side) see table 1 51 71 (27) 80 specifications for instrument with direct mounting adapter (screw connection type) long vent/drain plug (option) vent/drain plug press. conn. "d" (102) 25 84 23 20 s + +
the product conforms to the requirements of the electromagnetic compatibility directive 89/336/eec as detailed within the technical construction file number tn510412. the applicable standards used to demonstrate compliance are :- emi (emission) en50081-1 : 1992 "lvd - the transmitter is not covered by the requirements of the lvd standard." ems (immunity) en50082-1 : 1992 test item frequency range basic standard applicable electro- magnetic radiation disturbance 30-1000mhz en55022 class b test item no. test specification basic standard performance criteria 1 2 3 b a b electrostatic discharge fast transients common mode 0.5kv, 5/50 (tr/th) ns 5khz rep. radio-frequency electromagnetic field. 8kv (air) 27-500mhz 3v/m (unmodulated) iec 801-2:1984 iec 801-3:1984 iec 801-4:1988 information in this catalog is subject to change without notice. printed in japan head office 11-2 osaki 1-chome, shinagawa-ku, tokyo, 141-0032 japan phone: 81-3-5435-7111 http://www. fujielectric.co.jp/eng/sg/keisoku/welcome.htm sales div. international sales dept. no.1, fuji-machi, hino-city, tokyo 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187, 6189 fhx, fkx ... 3


▲Up To Search▲   

 
Price & Availability of EDSX6-103

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X