lc handover test system specification sheet jfw model 50PA-420 jfw industries, inc. phone: 317-887-1340 sales@jfwindustries.com www.jfwindustries.com frequency range 800-2200 mhz configuration 8 x 2 lc handover test system (see block diagram 092-5588) impedance 50 ohms nominal vswr 1.5:1 maximum attenuation range 0-127 db in 1 db steps attenuation accuracy 0.4 db or 2% of programmed (whichever is greater) insertion loss (ant1-ant8 to j1 or j2) 15.5 db nominal at 800 mhz 18.5 db nominal at 2200 mhz power divider isolation 25 db minimum rf input power +20 dbm average +30 dbm (no damage) switching speed 5 microseconds typical (after command is received and processed) (3 milliseconds typical processing time) ac supply 100-240 vac @ 47-63 hz manual control keypad and lcd display remote control ethernet (10/100) and rs-232 remote commands variable handover (vhnd av aw vx vy tz) feedback handover (fhnd av aw vx vy tz) fade attenuator (fax y z t) feedback fade (ffax y z t) pause (pausex) set attenuator (sax y) read attenuator (rax) change baud rate (cbx) identification (idn) rf connector sma or n female operating temperature range 0oc to +50oc jfw form e-7-f rev f page 1 of 2 --continued--
lc handover test system specification sheet jfw model 50PA-420 jfw industries, inc. phone: 317-887-1340 sales@jfwindustries.com www.jfwindustries.com physical size see outline drawing 092-5589 04/30/2008 trs 04/30/2008 ecr/ecn # date rev appr / date ecr/ecn # dat e rev appr / date 15916 05/28/2008 a trs 05/28/2008 15969 06/04/2008 b trs 06/04/2008 16179 08/07/2008 c trs 08/07/2008 jfw form e-7-f rev f page 2 of 2
|