![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
description moeller nk2528-1024gb easy control relay simply easy ? cl ever switching and controlling easy is a compact, user-friendly control relay for simple control applications. appli- cations range from building and domestic automation to machine and plant con- trol. easy has built-in user-friendly operating elements and an lcd display. just connect up easy and draw your circuit diagram on the display by pressing the buttons. easy works with make contacts, break contacts, and relays. enter your circuit diagram in easy just like you sketched it on paper. easy has basic and special functions for relay and contactor controls, and lots more. you can make changes to your circuit just by pressing the buttons. time consuming rewiring is not necessary. simply easy ? applications everywhere ? building and domestic automation, controllers for lighting, doors, window shutters... controls for ventilators, rotating doors, greenhouses, exterior lighting, window controllers, shop display lighting control... controls for temperature, ventilation and brightness levels... controls for machines and plant, presses, conveyor belts, oscillating conveyors, sorters, pumps... simply easy ? open for change the easy circuit diagram can be entered and modified just by pressing the buttons. simply easy ? everything built in (some features depend on the type) an lcd display for showing the circuit diagram operation buttons for wiring, value entry or switching 4 relay outputs with max. 10 a output current or 0.5 a transistor outputs up to 2 a, suitable for parallel connection circuit diagrams can be created with make contacts, break contacts, relays, series and parallel circuits voltage supply (24 v dc or 115/230 v ac) 8/12 digital inputs, expandable to 24 digital inputs (115/230 v ac or 24 v dc) 2 analog inputs (dc models only, two digital inputs can also be used for analog signals) non-volatile circuit diagram and parameter memory (eeprom) (retentive data) (eeprom) display of message texts, setpoint and actual values for timers, counters, time and analog values socket for external memory card or pc interface cable time switch with time and weekday(s) dst setting (summer time/winter time change) protect your circuit diagram and settings against unauthorized changes with a password to protect your know-how optional debounce (input delay) function (reliable switching with fast signals) selectable menu languages, 5 and 10 languages (d, gb, f, i, e, for easy600 also p, nl, s, pl,tr) 4 cursor buttons can also be used as input contacts in the easy circuit diagra (built in manual operation mode) local or remote expansion of inputs and outputs. remote expansion by means of two wire cable up to 30 m between basic unit and expansion unit large ambient temperature range from ?25 c to +55 c easy control relay s1 k1 k1 k2 t1 s4 t1 t1 s5 s6 3
moeller nk2528-1024gb description easy control relay simply easy ? compact and practical easy has a 45 mm as a standard dimension (4/6 space units) for installing in standard domestic distribution panels. easy can be clipped to a top-hat rail or screwed to a mounting plate for rugged environments. easy ? s dimensions are 71.5 x 90 x 53 mm or 107.5 x 90 x 53 mm. example: remote coupling with easy200-easy to a two wire cable simply easy ? more than 20 functions in a single device interconnect make contacts and break contacts 3 contacts can be connected in series up to 41 circuits (121 for easy600) can be connected in parallel switch relay coils create switching functions such changeover switches, self-latching relays, single pulse relays, start-delta starters create timing functions such as on-delayed, on-delayed with random switching, off-delayed, off-delayed with random switching, single pulse, flashing, up/down counter time switch compare analog values output texts, setpoint and actual values store retentively the actual values of timing relays, counters, markers, operating hours counters. simply expand connect the expansion unit to the basic unit using the connector to add up to 24 inputs and 16 outputs. the coupling device enables the expansion unit to be expanded up to 30 m away. simply network connect easy to a data bus as simply as you can expand it. connect the expansion unit for the as-interface and easy can already communicate with the bus master via the as-interface. profibus-dp is just as simple. easy is always a slave on the bus. pc software you can also create easy programs on a pc and download them to easy with the optional pc interface cable. create, store, simulate and document the circuit dia- gram offline. three display formats are available: din en, ansi or the easy display. 4 easy control relay moeller nk2528-1024gb easy control relay basic units, expansion units description type price article no. see price list std. pack basic units 24 v dc, retentive 8 digital inputs (2 inputs also usable as analog inputs) 4 relay outputs lcd display operating buttons screw terminals easy412-dc-r 202403 1 off features as per easy 412-dc-r plus built-in time switch easy412-dc-rc 202404 features as per easy412-dc-rc, without keypad an lcd display easy412-dc-rcx 221596 8 digital inputs (2 inputs also usable as analog inputs) 4 transistor outputs lcd display operating buttons screw terminals time switch easy412-dc-tc 207808 features as per easy412-dc-tc, without keypad an lcd display easy412-dc-tcx 212307 12 digital inputs (2 inputs also usable as analog inputs) 8 transistor outputs lcd display operating buttons screw terminals time switch easy620-dc-tc 212309 12 digital inputs (2 inputs also usable as analog inputs) 8 transistor outputs lcd display operating buttons screw terminals time switch expandable with easy.....e easy621-dc-tc 218719 features as per easy621-dc-tc, without keypad an lcd display easy621-dc-tcx 212311 115/230 v ac 8 digital inputs, 115/230 v ac 4 relay outputs lcd display operating buttons screw terminals easy412-ac-r 202405 1 off features as per easy 412-ac-r plus built-in time switch easy412-ac-rc 202406 features as per easy412-ac-rc, without keypad an lcd display easy412-ac-rcx 212308 115/230 v ac, retentive 12 digital inputs, 115/230 v ac 6 relay outputs lcd display operating buttons screw terminals time switch easy618-ac-rc 212310 12 digital inputs, 115/230 v ac 6 relay outputs lcd display operating buttons screw terminals time switch expandable with easy.....e easy619-ac-rc 218721 features as per easy619-ac-rc, without keypad an lcd display easy619-ac-rcx 212312 expansion units 24 v dc 12 digital inputs 8 transistor outputs with connector easy620-dc-te 212313 1 off 115/230 v ac 12 digital inputs, 115/230 v ac 6 relay outputs with connector easy618-ac-re 212314 coupling unit coupling unit for connecting to an easy619/621 basic unit terminals for remote expansion up to 30 m to the expansion unit with connector easy200-easy 212315 es c ok del alt 5 moeller nk2528-1024gb easy control relay networking, accessories, documentation easy control relay 6 description type price article no. see price list std. pack networking as-interface linked directly to easy619/621 as-interface connection slave 4 inputs, 4 outputs, 4 parameter bits addressable, 0 to 31 easy205-asi 221598 1 off profibus-dp linked directly to easy619/621 profibus-dp slave easy204-dp 212316 1 off accessories software cd, menu in 6 languages installation win 95, 98, win nt easy-soft 202407 1 off memory card 8k memory card for storing the entire easy circuit diagram for easy412 easy-m-8k 202408 16k memory card for storing the entire easy circuit diagram for easy6.. easy-m-16 212317 connection cable 2 m, for connecting to 9-pin serial interface on a pc with interface electronics circuit easy-pc-cab 202409 input/output simulator simulator with power supply unit, 115/230 v ac / output 24 v dc, suitable for easy412-dc... easy412-dc-sim 212318 fixing feet for screw fixing on mounting plate, 3 fixing feet per easy412, 3 fixing feet per easy6.., 2 fixing feet per easy200-easy zb4-101-gf1 061360 9 off switched-mode power supply unit primary-switched mode, stabilised 2, suitable for parallel connection to increase power output or for redundant operation at rated power rated input voltage 50/60 hz: 115/230 v ac rated output voltage (residual ripple): 24 v dc ( g 3%) rated output current: 1.25 a easy400-pow 212319 1 off documentation manual for easy control relay german AWB2528-1304-D 205375 1 off english awb2528-1304-gb 205481 french awb2528-1304-f 205482 italian awb2528-1304-i 205483 spanish awb2528-1304-e 205484 training guide for easy control relay german awb2528-1316-d 205376 1 off english awb2528-1316-gb 205485 french awb2528-1316-f 205486 italian awb2528-1316-i 205487 spanish awb2528-1316-e 205488 easy control relay moeller nk2528-1024gb rmq titan range selection button plate contacts m = make contact, b = break contact, f = safety function by means of positive opening to iec/en 60 947-5-1 colour plunger type price article no. see price list std. pack complete units for surface mounting to ip 66 emergency-stop actuator, tamper-proof to iso 13 850/en 418 pull to release max. configuration: 3x m22-(c)k... 1 m 1 b m22-pv-kc11/i 216525 2 off key-release mushroom buttons with 1 key ms 1 lock mechanism ? 1 m 1 b f m22-pvs/kc11/iy 216523 2 off key-operated buttons with two keys, two positions, stay-put ms 1 lock mechanism ? 1 m 1 b f m22-wrs/kc11/i 216526 2 off push-button flush ? 1 b f ? m22-d-r-x0/k01 216510 5 off 1 m ?? m22-d-g-x1/k10 216512 5 off selector switch, thumb-grip black stay-put/spring-return function can be changed using m22-xc-. coding adapters two positions, stay-put ? 1 m ?? m22-wrk/k10 216518 5 off complete units for front mounting, ip 66 emergency-stop actuator, tamper-proof to iso 13 850/en 418 yellow base pull to release ?? 1 b f m22-pv/k01 216515 5 off ivs top-hat rail adapter front fixing m22-ivs 216400 1 off notes other products are available in the moeller catalogue supplement, nk 1160-1033 gb 14 13 22 21 14 13 22 21 14 13 22 21 21 22 13 14 13 14 0 21 22 7 moeller nk2528-1024gb easy control relay technical data easy control relay easy200-easy easy412-... easy6..-... general standards and regulations en 55 011, en 55 022, iec/en 61 000-4, iec 60 068-2-6, iec 60 068-2-27 dimensions w h d [mm] 35.5 90 53 (2 space units) 71.5 90 53 (4 space units) 107.5 90 53 (6 space units) weight 70 g 200 g 300 g mounting top-hat rail, din 50 022, 35 mm or screw fixing with zb 4-101-gf1 fixing feet (accessories) ambient temperature operating ambient temperature horizontal/vertical mounting ? 25 to +55 c cold to iec 60 068-2-1 heat to iec 60 68-2-2 condensation prevent condensation with suitable measures lcd display (clearly visible) 0 to +55 c storage/transport temperature ? 40 to +70 c relative humidit 5 to 95%, non-condensing (iec 60 068-2-30) air pressure (operation) 795 to 1080 hpa corrosion resistance so 2 10 cm 3 /m 3 , 4 days (iec 60 068-2-42) h 2 s 1 cm 3 /m 3 , 4 days (iec 60 068-2-43) mechanical environmental conditions pollution degree 2 2 2 degree of protection (en 50 178, iec 60 529, vbg4) ip 20 ip 20 ip 20 oscillations (iec 60 068-2-6) 10 to 57 hz (constant amplitude 0.15 mm) 57 to 150 hz (constant acceleration 2 g) shock (iec 60 068-2-27) 18 shocks (semi-sinusoidal 15 g/11 ms) dropping (iec 60 068-2-31) drop height 50 mm free fall, in packaging (iec 60 068-2-32) 1 m electromagnetic compatibility (emc) electrostatic discharge (iec/en 61 000-4-2, level 3) 8 kv air discharge 6 kv contact discharge electromagnetic fields (iec/en 61 000-4-3) field strength 10 v/m emitted interference, interference immunity en 55 011 class b, en 55 022 class b burst (level 3) (iec/en 61 000-4-4) power cables 2 kv signal lines 2 kv high-energy pulses (surge) easy-ac (iec/en 61 000-4-5) 2 kv power cables symmetrical high-energy pulses (surge) easy-dc (iec/en 61 000-4-5, level 2) 0.5 kv power cables symmetrical dielectric strength measurement of the air clearance and creepage distance en 50 178, ul 508, csa c22.2, no 142 dielectric strength en 50 178 tools and cable cross-sections single-core min. 0.2 mm 2 , awg 24 max. 4 mm 2 , awg 12 flexible with ferrule min. 0.2 mm 2 , awg 24 max. 2.5 mm 2 , awg 13 slot-head screwdriver, width 3.5 0.8 mm tightening torque 0.5 ? 0.7 nm backup/accuracy of real-time clock (only with easy-c) clock battery back-up at 25 c ? normally 64 h at 40 c ? normally 24 h accuracy of the real-time clock ? normally g 5 s/day, ~ g 0.5 h/year repetition accuracy of timing relays accuracy of timing relays g 1 % of value resolution range ? s ? ? 10 ms range ? m:s ? ? 1 s range ? h:m ? ? 1 min. retentive memory write cycles of the retentive memory ? f 100 000 8 easy control relay moeller nk2528-1024gb easy control relay technical data easy412-ac-... easy618/619-ac-rc(x) easy618-ac-rc power supply rated voltage (sinusoidal) 115/120/230/240 v ac +10/ ? 15 % 100/110/115/120/230/240 v ac +10/ ? 15 permissible range 90 to 264 v ac 85 to 264 v ac frequency, rated value, tolerance 50/60 hz, g 5 % 50/60 hz, g 5 % input current consumption at 115/120 v ac 60 hz normally 40 ma normally 70 m at 230/240 v ac 50 hz normally 20 ma normally 35 m voltage dips (iec/en 61 131-2) 20ms 20ms heat dissipation at 115/120 v ac normally 5 va normally 10 va at 230/240 v ac normally 5 va normally 10 va easy412-dc-... easy620/621-dc-tc(x) easy620-dc-te power supply rated voltage rated value 24 v dc, ? 15 %, +20 % 24 v dc, ? 15 %, +20 % permissible range 20.4 to 28.8 v dc 20.4 to 28.8 v dc residual ripple f 5 % f 5 % input current at 24 v dc normally 80 ma normally 140 m voltage dips (iec/en 61 131-2) 10ms 10ms power dissipation at 24 v dc normally 2 w normally 5 w easy412-ac-... easy618/619-ac-rc(x) easy618-ac-re digital inputs 115/230 v ac number 8 12 status display lcd display (if provided) lcd display (if provided) electrical isolation to power supply no no between each other no no to the outputs yes yes rated voltage l (sinusoidal) 0 signal 0 to 40 v ac 0 to 40 v ac 1 signal 79 to 264 v ac 79 to 264 v ac rated frequency 50/60 hz 50/60 hz input current on 1 signal r1 to r12, i1 to i6 (easy 618/619 also i9 to i12) 6 x 0.5 ma at 230 v ac 50 hz 6 x 0.25 ma at 115 v ac 60 hz 10 (12) x 0.5 ma at 230 v ac 50 hz 10 (12) x 0.25 ma at 115 v ac 60 hz input current on 1 signal i7, i8 2 x 6 ma at 230 v ac 50 hz 2 x 4 ma at 115 v ac 60 hz 2 x 6 ma at 230 v ac 50 hz 2 x 4 ma at 115 v ac 60 hz delay time for 0 to 1 and 1 to 0 debounce on (i1 to i6/i12) 80 ms (50 hz), 66 n ms (60 hz) 80 ms (50 hz), 66 n ms (60 hz) debounce off (i1 to i6/i9 to i12) 20 ms (50 hz), 16 n ms (60 hz) 20 ms (50 hz), 16 n ms (60 hz) delay time i7, i8 for 1 to 0 debounce on 160 ms (50 hz), 150 ms (60 hz) 80 ms (50 hz), 66 n ms (60 hz) debounce off 100 ms (50 hz/60 hz) 20 ms (50 hz), 16 n ms (60 hz) delay time i7, i8 for 0 to 1 debounce on 80 ms (50 hz), 66 n ms (60 hz) 80 ms (50 hz), 66 n ms (60 hz) debounce off 20 ms (50 hz), 16 n ms (60 hz) 20 ms (50 hz), 16 n ms (60 hz) max. permissible cable length (per input) r1 to r12, i1 to i6 (with easy 618/619 also i9 to i12) normally 40 m normally 40 m i7, i8 normally 100 m normally 100 m 9 moeller nk2528-1024gb easy control relay technical data easy control relay easy412-dc-... easy620/621-dc-tc(x) easy620-tc-te digital inputs 24 v ac number 8, 2 of which (i7,i8) can be used as analog inputs 12, 2 of which (i7,i8) can be used as analog inputs, with basic unit status display lcd display (if provided) lcd display (if provided) electrical isolation to power supply no no between each other no no to the outputs yes yes 24 v dc power supply rated value 24 v dc 24 v dc 0 signal < 5.0 v dc i1 to i8 < 5.0 v dc i1 to i12, r1 to r12 1 signal > 15.0 v dc i1 to i6 > 15.0 v dc i1 to i6, i9 to i12, r1 to r12 input current on 1 signal r1 to r12, i1 to i6 (easy 620/621 also i9 to i12) 3.3 ma at 24 v dc 3.3 ma at 24 v dc input current on 1 signal i7, i8 2.2 ma at 24 v dc 2.2 ma at 24 v dc delay time for 0 to 1 debounce on 20 ms 20 ms debounce off normally 0.25 ms (i1 to i6) normally 0.25 ms (i1 to i6, i9 to i12) delay time for 1 to 0 debounce on 20 ms 20 ms debounce off normally 0.4 ms, i1 to i6 normally 0.2 ms i7, i8 normally 0.4 ms i1 to i6, i9 to i12 normally 0.2 ms i7, i8 cable length (unshielded) 100 m 100 m easy412-dc... easy620/621-dc-tc(x) analog inputs number 2 2 electrical isolation to power supply no no to the digital inputs no no to the outputs yes yes input type dc voltage dc voltage signal range 0 to 10 v dc 0 to 10 v dc resolution analog 0.1 v 0.1 v resolution digital 0.1 0.1 input impedance 11.2 k o 11.2 k o accuracy of two easy devices g 3 % of actual value within a single device g 2 % of actual value (i7, i8), g 0.12 v conversion time, analog/digital debounce on: 20 ms debounce off: every cycle input current < 1 ma cable length (shielded) 30 m u[v] 5.0 9.9 5.0 9.9 0 10 easy control relay moeller nk2528-1024gb easy control relay technical data easy412-...-r... easy618/619-r... relay outputs number 4 6 type of outputs relay in groups of 1 parallel connection of outputs to increase current rating not permissible circuit-breaker b 16 or fuse 8 at miniature circuit-breaker b16 or 8 a fuse (slow) potential isolation to mains supply, inputs yes 300 v eff ac (safe isolation) 600 v eff ac (basic isolation) mechanical lifespan (operations) 10 x 10 6 contacts relays conventional free air thermal current 8 a (10 a ul) recommended for load > 500 ma, 12 v ac/dc short-circuit resistance cos 1 16 a characteristic b (b16) at 600 a short-circuit resistance cos 0.5 to 0.7 16 a characteristic b (b16) at 900 a rated impulse withstand voltage u imp contact coil 6 kv rated insulation voltage u i 250 v ac rated operational voltage u e 250 v ac safe isolation to en 50 178 between coil and contact 250 v ac safe isolation to en 50 178 between two contacts 250 v eff making capacity ac-15 250 v ac, 3 a (600 ops/h) 300 000 switching operations dc-13 l/r f 150 ms 24 v dc, 1 a (500 ops/h) 200 000 switching operations breaking capacity ac-15 250 v ac, 3 a (600 ops/h) 300 000 switching operations dc-13 l/r f 150 ms 24 v dc, 1 a (500 ops/h) 200 000 switching operations filament lamp load 1000 w at 230/240 v ac 25 000 switching operations 500 w at 115/120 v ac 25 000 switching operations fluorescent tube 10 x 58 w at 230/240 v ac with ballast 25 000 switching operations uncompensated 25 000 switching operations 1 x 58 w at 230/240 v ac conventional, compensated 25 000 switching operations operating frequency, relays device lifetime 10 million (10 7 ) mechanical switching frequency 10 hz resistive lamp load 2 hz inductive load 0.5 hz easy400-pow input voltage 115, 230 v ac range 85 to 264 v ac mains frequency 50/60 hz range 47 to 63 hz output voltage (tolerance) 24 v dc ( g 3%) output current 1.25 a overcurrent limit from 1.4 a not adversely affected by no-load opera- tion and protected against short-circuit yes terminals single-core 0.2 to 4 mm 2 , awg 24 to 12 flexible with ferrule 0.2 to 2.5 mm 2 , awg 24 to 13 emitted interference, interference immunity en 50 081-1 class b; 50 082-2 potential isolation, primary/secondary yes, selv (vde 0100 t410; iec 364-4-41) protection class ip20 ambient temperature ? 25 to +55 c storage temperature ? 40 to +70 c 11 moeller nk2528-1024gb easy control relay technical data easy control relay easy412-dc-t... easy620/621-dc-t... transistor outputs number 4 8 contacts semiconductors semiconductors rated voltage u e 24 v dc 24 v dc permissible range 20.4 to 28.8 v dc 20.4 to 28.8 v dc residual ripple f 5 % f 5 % supply current 0 signal normally 9 ma, max. 16 ma normally 18 ma, max. 32 ma 1 signal normally 12 ma, max. 22 ma normally 24 ma, max. 44 ma reverse polarity protection yes potential isolation to inputs, power sup- ply yes rated current i e for 1 signal max. 0.5 a dc lamp load 5 watts without r v residual current with 0 signal per channel < 1.0 ma max. output voltage with 0 signal with external load < 10 m o 2.5 v with 1 signal, i e = 0.5 a u = u e ? 1 v short-circuit protection yes, (detected via diagnostics input i16, i15; r15; r16) short-circuit tripping current for r a f 10 m o 0.7 a f i e f 2 a max. total short-circuit current 8 a 16 a peak short-circuit current 16 a 32 a thermal cutout yes yes maximum operating frequency at constant resistive load r l < 100 k o : operations per hour 40 000 (depends on circuit diagram and load) parallel connection of outputs with resistive load; inductive load with external suppression circuit, combination within a group group 1: q1 to q4 group 1: q1 to q4, s1 to s4 group 2: q5 to q8, s5 to s8 number of outputs max. 4 max. 4 total maximum current 2.0 a status display of the outputs lcd display (if provided) lcd display (if provided) approvals currently ul/csa approved; others in preparation: easy412-dc-r easy412-dc-rc easy412-dc-tc easy412-dc-tcx easy412-ac-r easy412-ac-rc easy412-ac-rx easy620-dc-tc easy618-ac-rc notes for more detailed technical specifications refer to technical data in awb 2528-1304-gb 12 easy control relay moeller nk2528-1024gb easy control relay dimensions control relay easy200-easy easy4... easy618-... easy619-... easy620-... easy621-... m4 7.5 35.5 7.5 90 102 110 71.5 m4 10.75 50 35.75 45 58 56.5 47.5 4.5 45 58 56.5 47.5 4.5 90 102 110 m4 107.5 75 16.25 16.25 13 |
Price & Availability of AWB2528-1304-D
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |