iso 9001 iso 14001 as 9100 certified mini-circuits ? p.o. box 350166, brooklyn, new york 11235-0003 (718) 934-4500 fax (718) 332-4661 for detailed performance specs & shopping online see mini-circuits web site the design engineers search engine provides actual data instantly from mini-circuits at: www.minicircuits.com minicircuits.com tm if/rf microwave components typical performance data directional coupler electrical specifcations maximum ratings pin connections input 3 output 4 coupled 1 ground 2 50 ? term external 6 not used 5 operating temperature -40c to 85c storage temperature -55c to 100c case style: db714 price: $1.49 ea. qty (25) demo board mcl p/n: tb-71 suggested pcb layout (pl-009) outline drawing outline dimensions ( ) inch mm TCD-9-1W mainline loss 0.0 0.5 1.0 1.5 2.0 2.5 3.0 0 500 1000 1500 2000 frequency (mhz) mainline loss (db) at rf level of -10 dbm TCD-9-1W coupling & directivity 0 10 20 30 40 0 500 1000 1500 2000 frequency (mhz) coupling & directivity (db) coupling directivity at rf level of -10 dbm TCD-9-1W+ TCD-9-1W TCD-9-1W return loss 0 10 20 30 40 50 0 500 1000 1500 2000 frequency (mhz) return loss (db) in out cpl at rf level of -10 dbm 50 ? 5 to 2000 mhz directional coupler rev. f m119986 ed-8571/1 tcd-9-1 w wz/td/cp/am 081113 surface mount abcdef .160 .150 .160 .050 .040 .025 4.06 3.81 4.06 1.27 1.02 0.64 g h j k wt .028 .065 .190 .030 grams 0.71 1.65 4.83 0.76 0.15 freq. range (mhz) coupling (db) mainline loss 1 (db) directivity (db) vswr (:1) power input, w nom. flatness l m u l m u l mu f l -f u typ. max. typ. max. typ. max. typ. min. typ. min. typ. min. typ. max. max. 5-1000 8.9 0.5 0.6 1.2 2.1 1.2 1.8 1.5 2.1 21 17 17 10 13 1.30 0.5 1.0 1000-2000 8.9 0.5 0.6 2.5 10 1.60 1.0 frequency (mhz) mainline loss (db) in-out coupling (db) in-cpl directivity (db) in return loss (db) out cpl features ? wideband, 5 to 2000 mhz ? low mainline loss, 1.2 db typ. (5-1000 mhz) ? aqueous washable ? leads for excellent solderability ? protected by us patent 6,140,887 applications ? gps ? cellular ? satellite distribution ? cable tv + rohs compliant in accordance with eu directive (2002/95/ec) the +suffx identifes rohs compliance. see our web site for rohs compliance methodologies and qualifcations. l = low range [f l to 10 f l ] m = mid range [10 f l to f u /2] u= upper range [f u /2 to f u ] 1. mainline loss includes theoretical power loss at coupled port. 5.00 1.11 8.96 21.65 19.14 27.81 18.92 200.00 1.14 8.97 20.18 20.84 30.26 20.66 600.00 1.26 8.67 15.41 21.16 22.87 20.18 800.00 1.38 8.61 13.30 20.11 22.87 18.90 1000.00 1.54 8.48 11.72 18.37 22.07 17.30 1200.00 1.74 8.57 10.31 16.42 21.82 15.67 1400.00 2.04 8.57 9.19 14.49 22.16 14.29 1600.00 2.32 8.61 8.42 12.72 21.46 12.97 1800.00 2.72 8.75 7.63 11.17 23.19 11.93 2000.00 3.07 8.76 7.28 9.96 22.33 10.99 sugges te d la yo ut, to le ra nce to be wi th in .002 pcb la nd pa tter n electrical schematic
|