rev.b dot pin1 linkcom lal xxxx x date code g s LAL2094-50 2-1 broadband access transformer designed to meet ul 60950 and en 60950 requirement s for supplementary insulation rohs compliant operating temperature -40c to 85c electrical specifications @25 ocl: pin 16-9= 200uh 10% @ 10khz/0.1v/ser. (pin 1 1-14 short) pin 16-9= 30uh max. @ 100khz/100mv (pin 11-14,pin 2-3,1-4 short) leakage inductance: pin 16-9= 30uh max. @ 100khz/100mv ( pin 11-14,pi n 7-6,5-8 short) pin 16-5= 80pf max. @ 100khz/100mv ( pin 11-14,pi n 7-6 short) interwinding capacitance pin 16-1= 50pf max. @ 100khz/100mv ( pin 11-14,pi n 2-3 short) pin 16-9 to pin 1-4= -80db max. @ 30khz/2v ( pin 1 1-14,pin 2-3 short) t.h.d pin 16-9 to pin 5-8= -80db max. @ 30khz/2v ( pin 1 1-14,pin 7-6 short) pin 16-9 = 5.0 ohm max. ( pin 11-14 short) d.c.r pin 1-4= 10 ohm max. ( pin 2-3 short) pin 5-8= 2.0 ohm max. ( pin 7-6 short) hi-pot : pri. C sec. =1875vac/60hz/2seconds/1ma pin16-9 : pin 1-4 = 12% :1 ( pin 11-14,pin 2-3 sh ort) turn ratio: pin16-9 : pin 5-8 = 3.82% :1 ( pin 11-14,pin 7-6 short) dimensions (units: mm) schematic there shall be no breakdown between winding 1,3,2,4 ,5,7,6,8 & 16,11,14 ,9 when tested according to itu-tk.21:2003 enhanced level 6 kv, par. 2.1.1.b using the test procedures of k.44:2003. mark 1.lal****----lal2094 2. x----product line 3. date code----yyww 4. g----rohs
|