Part Number Hot Search : 
NSSW203T 2518T 31GF6A HT9202L BP20100 BSP171 390360 1J000
Product Description
Full Text Search
 

To Download G24-13-SNDDC24V Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  9 replacement relays for i/o blocks and bases use relays to fill i/o bases and to replace relays supplied with i/o blocks 3 relay series compatibility with i/o blocks and bases relay series applicable i/o blocks and bases g2r electromechanical g70a output base, g730-rid and g730-roc04 i/o modules g3r solid state g70a output base, g730-ria i/o modules g3rz power mosfet relay g730-zia, g730-zid and g730-zom i/o modules g7t electromechanical p7tf relay bases, g7tc relay blocks g3ta solid state p7tf relay bases, g7tc relay blocks g6d electromechanical g70d and g70d-r6-b7a relay blocks, srt2-roc08/-roc16 output m odules, g730 g3dz power mosfet relay g70d and g70d-r6-b7a relay blocks, srt2-rof output m odules, g730-aom/-zim/-zom i/o modules g2r power pcb relay 3 ordering information applicable block base classification applicable load rated input voltage part number g70a relay output base, g 7 3 0 r i d d g 7 3 0 r o c 0 4 i / o input relay 21.8maat24vdc 24 vdc g2r-1a3-snd dc24v y , g730-rid and g730-roc04 i/o m o d u l e s ( r e f e r t o g 7 0 a a n d g 7 3 0 - r g2r-13-snd dc24v mo d u l es ( r e f er t o g 7 0 a an d g 7 3 0 - r data sheets for specific models) output relay 10 a at 250 vac/30 vdc 24 vdc g2r-1-snd dc24 d a t a s h e e t s f o r s e c i f i c m o d e l s ) y 12 vdc g2r-1-snd dc12 3 input relays g2r-1a3-snd and g2r-13-snd coil ratings rated voltage 230 vac 12 vdc 24 vdc rated current 50 hz 3.7 ma 43.6 ma 21.8 ma 60 hz 3.1 ma coil resistance 30,000 ? 275 ? 1,100 ? must operate voltage 80% max. of rated voltage 70% max. of rated voltage must release voltage 30% min. of rated voltage 15% min. of rated voltage max. voltage 110% of rated voltage power consumption approx. 0.7 w (60 hz) approx. 0.53 w note: 1. the rated current and coil resistance are measured at a coil temperature of 23 c with a tolerance of +15% / --20% (ac rated cur- rent) or . 10% (dc coil resistance). 2. leds are used for the built-in operation indicator. for models equipped with these indications, the vac rated current must be increased by approximately 1 ma; the vdc rated current, by approximately 4 ma.
replacement relays replacement relays 2 3 output relays g2r-1-s and g2r-1-sn coil ratings rated voltage 24 vdc rated current (50/60 hz) 21.8 ma coil resistance 1,100 ? coil inductance armature off 4.27 (h) (ref. value) armature on 8.55 must operate voltage 70% min. of rated voltage must release voltage 15% min. of rated voltage max. voltage 110% of rated voltage power consumption approx. 0.53 w contact ratings also refer to ratings/characteristics of g70a-zim16-5. number of poles 1 pole load resistive load (p.f. = 1) inductive load (p.f. = 0.4; l/r = 7 ms) rated load 10 a at 250 vac; 10 a at 30 vdc 7.5 a at 250 vac; 5 a at 30 vdc rated carry current 10 a max. operating voltage 380 vac, 125 vdc max. operating current 10 a max. switching capacity 2,500 va, 300 w 1,875 va, 150 w min. permissible load 100 ma at 5 vdc g3r solid state relay 3 ordering information input relays applicable block b isolation indicator response d logic level rated input l t part number p p base p speed supply voltage supply current p voltage g70a relay input b g 7 3 0 r i a i / o photo- l yes -- -- -- 4to 3 2 v d c 0.1 to 1 0 0 a 100 to 240 vac g3r-iazr1sn ac100-240 y base, g730-ria i/o m o d u l e s ( r e f e r t o coupler high-speed 32 vdc 100 ma 5vdc g3r-idzr1sn dc5 mo d u l es ( r e f er t o g70a and g730-r g 12 to 24 vdc g3r-idzr1sn dc12-24 g 7 0 a a n d g 7 3 0 r data sheets for s p e c i f i c m o d e l s ) low-speed 5vdc g3r-idzr1sn-1 dc5 specific models) 12 to 24 vdc g3r-idzr1sn-1 dc12-24 output relays applicable block base isolation indicator zero cross function applicable output load rated input part number g70a relay output base, g 7 3 0 r i a i / o d l phototriac yes yes 2 a at 75 to 264 vac 5to 2 4 v d c g3r-oa202szn dc5-24 y , g730-ria i/o modules ( r e f e r t o g 7 0 a a n d no 24 vdc g3r-oa202sln dc5-24 ( r e f er t o g 7 0 a an d g730-r data sheets for photocoupler -- -- -- 2aat4to60vdc g3r-odx02sn dc5-24 g 7 3 0 r d a t a s h e e t s f o r specific models) 1 a at 40 to 200 vdc g3r-od201sn dc5-24
replacement relays replacement relays 3 3 ratings input relays input ratings part number rated voltage operating voltage input current must operate voltage must release voltage g3r-iazr1sn 100 to 240 vac 60 to 264 vac 15 ma max. 60 vac max. 20 vac min. g3r-idzr1sn 5vdc 4to6vdc 8mamax. 4vdcmax. 1vdcmin. 12 to 24 vdc 6.6to32vdc 6.6 vdc max. 3.6 vdc min. g3r-idzr1sn-1 5vdc 4to6vdc 4vdcmax. 1vdcmin. 12 to 24 vdc 6.6to32vdc 6.6 vdc max. 3.6 vdc min. output ratings part number logic level supply voltage logic level supply current g3r-iazr1sn 4to32vdc 0.1 to 100 ma g3r-idzr1sn g3r-idzr1sn-1 output relays input ratings part number rated voltage operating voltage input current must operate voltage must release voltage g3r-oa202szn 5to24vdc 4to32vdc 15 ma max. ( t 2 5 c ) 4vdcmax. 1vdcmin. g3r-oa202sln (at 25 c) g3r-odx02sn 8mamax. g3r-od201sn output ratings part number load voltage load current (see note) inrush current g3r-oa202szn 75 to 264 vac 0.05 to 2 a 30 a (60 hz, 1 cycle) g3r-oa202sln g3r-odx02sn 4to60vdc 0.01 to 2 a 8a(10ms) g3r-od201sn 40 to 200 vdc 0.01 to 1.5 a 8a(10ms) note: the minimum current value is measured at 10 cmin. 3 characteristics input relays item g3r-iazr1sn g3r-idzr1sn g3r-idzr1sn-1 operate time 20 ms max. 0.1 ms max. 15 ms max. release time 20 ms max. 0.1 ms max. 15 ms max. response frequency 10 hz 1khz 10 hz output on voltage drop 1.6 v max. leakage current 5 m amax. insulation resistance 100 m w min. between input and output dielectric strength 4,000 vac for 1 min between input and output vibration resistance 10 to 55 hz, 1.5 mm double amplitude shock resistance 1,000 m/s 2 (approx. 100g) ambient temperature operating: --30 cto80 c(--22 f to 176 f) with no icing storage: --30 c to 100 c(--22 f to 212 f) with no icing ambient humidity operating: 45% to 85% weight approx. 18 g
replacement relays replacement relays 4 output relays item g3r-oa202szn g3r-oa202sln g3r-odx02sn g3r-oa201sn operate time 1/2 of load power source cycle + 1 ms max. 1msmax. release time 1/2 of load power source cycle + 1 ms max. 2msmax. response frequency 20 hz 100 khz output on voltage drop 1.6 v max. 2.5 v max. leakage current 1.5 ma max. 1mamax. insulation resistance 100 m w min. between input and output dielectric strength 4,000 vac for 1 min between input and output vibration resistance 10 to 55 hz, 1.5 mm double amplitude shock resistance 1,000 m/s 2 (approx. 100g) ambient temperature operating: --30 to 80 c(--22 f to 176 f) with no icing storage: --30 to 100 c(--22 f to 212 f) with no icing ambient humidity operating: 45% to 85% weight approx. 18 g 3 engineering data load current vs. ambient temperature characteristics g730-zom04 + g3r-oa202s p n g730-zom04 + g3r-od201sn (40 to 200 vdc) g730-zom04 + g3r-odx02sn (4 to 60 vdc) ambient temperature ( c) load current (a) ambient temperature ( c) load current (a) ambient temperature ( c) load current (a) four points mounted four points mounted four points mounted note: the above data are for a g730 mounted with four g3rs. inrush current resistivity non-repetitive (keep the inrush current to half the rated value if it occurs repetitively.) g3r-oa202s p n inrush current (a. peak) energizing time (ms) inrush current (a. peak) energizing time (ms) inrush current (a. peak) energizing time (ms) g3r-od201sn g3r-odx02sn
replacement relays replacement relays 5 g3rz power mosfet relay 3 ordering information input/output relays applicable block base classification insulation method indicator zero cross function applicable output load rated input voltage part number g730-zia, g730-zid and g 7 3 0 z o m i / o b input relay or t t l photodiode yes no 1.0 a at 3 t 2 6 4 v a c / 5vdc g3rz-201sln dc5 g730-zom i/o bases ( refer to g730-r data y output relay array 3to264vac/ 3to125vdc 12 vdc g3rz-201sln dc1 2 ( r e f e r t o g 7 3 0 - r d a t a sheets for specific models) 3 t o 1 2 5 v d c 24 vdc g3rz-201sln dc24 3 ratings input/output relays input ratings part number rated voltage operating voltage input impedance must operate voltage must release voltage g3rz-201sln 5vdc 4to6vdc 400 w 20% 4vdcmax. 1vdcmin. 12 vdc 9.6 to 14.4 vdc 1.1 k w 20% 9.6 vdc max. 24 vdc 19.2 to 28.8 vdc 2.2 k w 20% 19.2 vdc max. output ratings load voltage load current inrush current 3to264vac,3to125vdc 100 m ato1.0a 10 a (10 ms) 3 characteristics input/output relays item g3rz-201sln operate time 6msmax. release time 10 ms max. output on-resistance 2.4 w max. leakage current 10 m a max. at 125 vdc insulation resistance 100 m w min. at 500 vdc dielectric strength 2,500 vac, 50/60 hz for 1 min between input and output vibration resistance 10 to 55 hz, 1.5 mm double amplitude shock resistance 1,000 m/s 2 (approx. 100g) ambient temperature operating: --30 cto85 c(--22 f to 185 f) with no icing storage: --30 c to 100 c(--22 f to 212 f) with no icing ambient humidity operating: 45% to 85% weight approx. 20 g
replacement relays replacement relays 6 3 reference data load current vs. ambient temperature characteristics inrush current resistivity non-repetitive (keep the inrush current to half the rated value if it occurs repetitively.) g3rz-201sln load current (a) inrush current (a. peak) ambient temperature ( c) energizing time (ms) note: the above data are for a g730 mounted with four g3rzs. g3rz-201sln g7t power relay 3 ordering information applicable block base classification applicable load rated input voltage part number p7tf bases and g7tc i/o blocks input relay, ac coil 10 to 100 ma 110/120 vac g7t-1122s ac110/120 v ( r e f e r t o g 7 t c d a t a s h e e t f o r y , 200/220 vac g7t-1122s ac200/220v ( r e f er t o g 7 t c d a t as h ee t f or specific models) input relay, dc coil 10 to 100 ma 24 vdc g7t-1122s dc24v s e c i f i c m o d e l s ) output relay, dc coil 5a 12 vdc g7t-1112s dc12v y , 24 vdc g7t-1112s dc24v 3 ratings input/output relays coil ratings (common to input/output per relay) rated voltage (v) rated current (ma) coil resistance ( s n 1 ) must operate must release maximum voltage power consumption 50 hz 60 hz r e s i s t a n c e (see note 1) percent of rated voltage per relay per 16 relays ac 110/120 220/240 7.5/ 3.7/ 6.4/7.0 3.2/3.5 13,000 w 48,300 w 80% max. 30% min. 110% 0.7 va 11 va dc 12 42 290 w 80% max. 10% min. 110% 0.5 w 8w dc 24 21 1,150 w 80% max. 10% min. 110% 0.5 w 8w note: 1. the rated current and coil resistance are measured at a coil temperature of +23 c with a tolerance of +15%/--20% for ac rated current and 15% for coil resistance. 2. approx. 4 ma flows into each led indicator. to calculate the power supply capacity, add the current value of each indicator.
replacement relays replacement relays 7 contact ratings (common to input/output per relay) classification for input for output resistive load (cos j =1) inductive load (cos j =0.4 l/r=7 ms) resistive load (cos j =1) inductive load (cos j =0.4 l/r=7 ms) carry current 1a 5a switching voltage 250 vac, 125 vdc switching current 1a 0.5 a 5a 2a switching power dc 24 w dc 12 w dc 120 w ac 440 va dc 48 w ac 220 va min. permissible load 100 m aat1v 10 ma at 5 v electrical life 10,000,000 operations (at 10 ma) 50,000 operations (at 1 a) 2,500,000 operations (at 10 ma) 20,000 operations (at 1 a) 1,000,000 operations (under rated load) mechanical life 50,000,000 operations 3 characteristics: g7t relays part number g7tc-ia16 (input, ac coil) g7tc-id16 (input, dc coil) g7tc-oc16 (-1) (output, dc coil) g7tc-oc08 (-1) (output, dc coil) led color red green green case color transparent red transparent green transparent contact resistance 50 m w max. operate time 15 ms max. release time 15 ms max. max. operating f mechanical limit 18,000 operations/hour p g frequency at rated load 1,800 operations/hour insulation resistance 100 m w at 500 vdc dielectric t t h between coil and contact 2,000 vac, 50/60 hz for 1 minute strength between same polarity contacts 1,000 vac, 50/60 hz for 1 minute between paired connectors 250 vac, 50/60 hz for 1 minute malfunction vibration 10 to 55 hz with 1.0-mm double amplitude malfunction shock 200 m/s 2 noise immunity noise level: 1.5 kv; pulse width: 100 ns to 1 m s rated voltage between positive and negative terminal blocks rated voltage of controllers (plc or other) input circuit 24 vdc 5% rated current between positive and negative terminal blocks input circuit current of controller (plc or other) x number of on points 24 vdc: 25 ma x number of on points cable length to controller 5 m max. (reference value) g to i/o devices 50 m max. (reference value, for 2-mm 2 cvv cable) dependent on load ambient operating temperature 0 cto55 c(32 f to 131 f) ambient operating humidity 35% to 85% i/o terminal tightening torque 8to12kg : cm coil surge absorber variable resistor diode (1 a, 400 v) weight approx. 640 g approx. 630 g approx. 670 g approx. 350 g ul and csa standards standard g7tc i/o blo cks, except for the g7tc-oc16-1 and the g7tc-oc08(-1), have met ul and csa st andards (ul file no. e41643; csa file no. lr31928). note that the following ul- and csa-qualifying ratings differ from the performance characteristics of the individual models: model coil ratings contact ratings g7tc-id16, g7tc-ia16 10 ma/point, 24 vdc 250 vac max. g7tc-oc16 coil drive current, 24 vdc inductive load: 10 a, 250 vac resistive load: 10 a, 30 vdc rated horsepower: 1/2 hp, 240 vac
replacement relays replacement relays 8 3 engineering data g7t relays g3ta solid state relay 3 ordering information applicable block base classification applicable load rated input voltage part number p 7 t f b a s e s a n d g 7 t c i / o b l o c k s i n p u t r e l a y a c c o i l 2 5 m a 1 0 0 - 2 4 0 v a c g 3 t a - i a z r 0 2 s a c 1 0 0 / 2 4 0 v p 7 t f b ases an d g 7 t c i / o b l oc k s ( r f t g 7 t c d t h t f i f i i nput re l ay, a c co i l 2 5 m a 1 0 0 - 2 4 0 v a c g 3 t a - i a z r 0 2 s a c 1 0 0 / 2 4 0 v (refer to g7tc data sheet for specific m o d e l s ) input relay, dc coil 25 ma 5-24 vdc g3ta-idzr02s dc5-24v m o d e l s ) output relay, dc coil 2a 12 vdc g3ta-odx02s 12vdc y , 2a 24 vdc g3ta-odx02s dc24v 1a 24 vdc g3ta-od201s dc24v 3 ratings: g3ta solid state relays input relay input ratings part number rated voltage operating l t input current voltage level p g voltage must operate voltage must release voltage g3ta-iazr02s ac100/240v 100 to 240 vac 80 to 264 vdc 5mamax. 80 vac max. 10 vac min. g3ta-idzr02s dc5-24v 5to24vdc 4to32vdc 4vdcmax. 1vdcmin. output ratings part number logic level supply voltage output breakdown voltage output current output current (load current) g3ta-iazr02s ac100/240v 4to32vdc 32 vdc max. 25 ma max. 0.1to25ma g3ta-idzr02s dc5-24v
replacement relays replacement relays 9 output relay input ratings part number rated voltage operating l t input i d voltage level p g voltage p impedance must operate voltage must release voltage g3ta-oa202sz dc12v 12 vdc 9.6 to 13.2 vdc 0.9 k w 20% 9.6 vdc max. 2vdcmin. g3ta-oa202sz dc24v 24 vdc 19.2 to 26.4 vdc 1.7 k w 20% 19.2 vdc max. g3ta-odx02s dc24v 12 vdc 9.6 to 13.2 vdc 3.5 k w 20% 9.6 vdc max. 24 vdc 19.2 to 26.4 vdc 6.5 k w 20% 19.2 vdc max. g3ta-od201s dc24v 24 vdc 19.2 to 26.4 vdc 6.4 k w 20% 19.2 vdc max. output ratings part number applicable load rated load voltage load voltage load current (see note) inrush current g3ta-oa202sz 100 to 240 vac 75 to 264 vac 0.05 to 2 a 30 a (60 hz, 1 cycle) g3ta-oa202sl 100 to 240 vac 75 to 264 vac g3ta-odx02s 5to48vdc 4to60vdc 0.01 to 2 a 12 a (10 ms) g3ta-od201s 48 to 200 vdc 40 to 200 vdc 0.01 to 1 a 6a(10ms) note: the minimum current value is measured at 10 cmin. 3 characteristics: g3ta solid state relays input relay item g3ta-iazr02s g3ta-idzr02s operate time 20 ms max. 0.5 ms max. release time 20 ms max. 0.5 ms max. output on voltage drop 1.6 v max. leakage current 5 m amax. insulation resistance 100 m w min. at 500 vdc dielectric strength 4,000 vac, 50/60 hz for 1 min between input and output vibration resistance malfunction: 10 to 55 hz, 1.5-mm double amplitude shock resistance malfunction: 1,000 m/s 2 {approx. 100g} ambient temperature operating: --30 cto80 c(--22 f to 176 f) with no icing or condensation storage: --30 c to 100 c(--22 f to 212 f) with no icing or condensation ambient humidity operating: 45% to 85% approved standards ul508 file no. e64562/csa c22.2 (no. 0, no. 14) file no. lr35535 weight approx. 16 g output relay item g3ta-oa202sz g3ta-odx02s g3ta-od201s operate time 1/2 of load power source cycle + 1 ms max. 0.5 ms max. 2msmax. release time 1/2 of load power source cycle + 1 ms max. 2msmax. 2msmax. output on voltage drop 1.6 v max. 2.5 v max. leakage current 5 ma max. at 200 vac 1mamax. insulation resistance 100 m w min. at 500 vdc dielectric strength 4,000 vac, 50/60 hz for 1 min between input and output vibration resistance malfunction: 10 to 55 hz, 1.5-mm double amplitude shock resistance malfunction: 1,000 m/s 2 {approx. 100g} ambient temperature operating: --30 cto80 c(--22 f to 176 f) with no icing or condensation storage: --30 c to 100 c(--22 f to 212 f) with no icing or condensation ambient humidity operating: 45% to 85% approved standards ul508 file no. e64562, csa c22.2 (no. 14) file no. lr3553 weight approx. 23 g
replacement relays replacement relays 10 3 mixing g3ta with g7t relays in the same i/o block with up to four g3ta ssrs mounted before g7t relays, 2-a loads can be switched. with g3ta ssrs mounted before every other g7t relays, 2-a loads can be switched. g3ta g7t g3ta g7t 3 engineering data load current vs. ambient temperature characteristics g3ta-oa202sz/oa202sl/odx02s ambient temperature ( c) ambient temperature ( c) load current (a) load current (a) g3ta-od201s single-point mounting 16-point mounting single-point mounting 16-point mounting non-repetitive (keep the inrush current to half the rated value if it occurs repetitively.) g3ta-odx02s g3ta-od201s inrush current (a. peak) energizing time (ms) inrush current (a. peak) energizing time (ms) inrush current (a. peak) energizing time (ms) g3ta-oa202sz
replacement relays replacement relays 11 g6d power relay 3 ordering information applicable block base classification applicable load rated coil voltage part number g70d and g70d-r6-b7a output bases, srt2-roc08/-roc16 t t d l d g 7 3 0 d l output relay 5a 5vdc g6d-1a dc5 output modules and g730 modules. ( refer to g70d , g70d-r6-b7a , srt ? -r and g730-r data 12 vdc g6d-1a dc12 ( r e f e r t o g 7 0 d , g 7 0 d - r 6 - b 7 a , s r t ? - r a n d g 7 3 0 - r d a t a sheets for specific models) 24 vdc g6d-1a dc24 3 ratings coil ratings rated voltage 5vdc 12 vdc 24 vdc rated current 40 ma 16.7 ma 8.3 ma coil resistance 125 w 720 w 2,880 w must operate voltage (see note 1) 70% max. of rated voltage must release voltage 10% min. of rated voltage max. voltage 130% of rated voltage power consumption approx. 200 mw note: 1. the must operate voltage is 75% or less of the rated voltage if the relay is mounted upside down. 2. rated current and coil resistance were measured at a coil temperature of 23 e c with a tolerance of 10%. 3. operating characteristics were measured at a coil temperature of 23 e c. 4. the maximum allowable voltage is the maximum value of the allowable voltage range for the relay coil operating power supply. there is no continuous allowance. contact ratings load classification resistive load (p.f. = 1) inductive load (p.f. = 0.40, l/r = 7 ms rated load 5 a at 250 vac, 30 vdc 2 a at 50 vac, 30 vdc carry current 5a max. operating voltage 250 vac, 30 vdc max. operating current 5a max. switching capacity 1250 va, 150 w 500 va, 60 w min. permissible load 10 ma at 5 vdc life expectancy mechanical: 20,000,000 operations min. (at 18,000 operations/hr) electrical: 100,000 operations min. (5 a at 250 vac, resistive load) 100,000 operations min. (5 a at 30 vdc, resistive load) 300,000 operations min. (2 a at 250 vac, resistive load) 300,000 operations min. (2 a at 30 vdc, resistive load) (at 1,800 operations/hr) 3 characteristics contact resistance (see note 2) 100 m w max. operate time 10 ms max. release time 5msmax. insulation resistance 1,000 m w min. at 500 vdc dielectric strength 3,000 vac, 50/60 hz for 1 min between coil and contacts 750 vac, 50/60 hz for 1 min between contacts of same polarity surge withstand voltage 6,000 v, 1.2 x 50 m s between coil and contacts vibration resistance destruction: 10 to 55 hz, 1.5-mm double amplitude malfunction: 10 to 55 hz, 1.5-mm double amplitude shock resistance destruction: 1,000 m/s 2 malfunction: 100 m/s 2 ambient temperature operating: --25 cto70 c(--13 f to 158 f) ambient humidity operating: 45% to 85% weight approx. 3 g note: 1. the above values are initial values. 2. measurement condition: 1 a at 5 vdc
replacement relays replacement relays 12 3 reference data life expectancy max. switching capacity switching current (a) switching voltage (v) life expectancy (x 10 operations) 3 switching current (a) 5,000 3,000 1,000 500 300 100 50 30 250 vac/30 vdc resistive load 250 vac/30 vdc inductive load (cos f = 0.4, l/r = 7 ms) dc resistive load dc inductive load ac resistive load ac inductive load (cos f =0.4) g3dz power mosfet relay 3 ordering information input/output relays applicable block base classification insulation method indicator zero cross function applicable output load rated input voltage part number g70d and g70d-r6-b7a output bases, srt2-rof o u t p u t m o d u l e s a n d input relay or output relay photo- diode a r r a y no no 100 m ato0.6a 5to240vac/ 5 t o 1 0 0 v d c 5vdc g3dz-2r6pl dc5 ou t pu t mo d u l es an d g730-aom/-zim/-zom i/o modules. (refer to g70d, g 7 0 d r 6 b 7 a s r t r array 5 t o 1 0 0 v d c 12 vdc g3dz-2r6pl dc12 g70d-r6-b7a, srt ? -r and g730-r data sheets for specific models) 24 vdc g3dz-2r6pl dc24 3 ratings output relay input ratings rated voltage operating voltage input impedance voltage level must operate must release 5vdc 4to6vdc 830 w 20% 4vdcmax. 1vdcmin. 12 vdc 9.6 to 14.4 vdc 2k w 20% 9.6 vdc max. 24 vdc 19.2 to 28.8 vdc 4k w 20% 19.2 vdc max. output ratings load voltage load current inrush current 3to264vac,3to125vdc 100 m ato0.6a 6a(10ms)
replacement relays replacement relays 3 characteristics operate time 6msmax. release time 10 ms max. output on-resistance 2.4 w max. leakage current 10 m a max. at 125 vdc insulation resistance 100 m w max. at 500 vdc dielectric strength 2,500 vdc, 50/60 hz for 1 min vibration resistance 10 to 55 hz, 1.5 mm double amplitude shock resistance 1,000 m/s 2 (approx. 100g) ambient temperature operating: --30 cto85 c(--22 f to185 f) with no icing storage: --30 c to 100 c(--22 f to 212vf) with no icing ambient humidity operating: 45% to 85% weight approx. 3.1 g 3 engineering data load current vs. ambient temperature characteristics g3dz-2r6pl inrush current resistivity non-repetitive (keep the inrush current to half the rated value if it occurs repetitively.) g3dz-2r6pl ambient temperature ( c) energizing time (ms) load current (a) inrush current (a.peak) note: the above data are for a g730 mounted with 8 or 16 g3dzs. cat. no. gc rio-1 04/00 specifications subject to change without notice. printed in u.s.a. omron electronics, inc. oneeastcommercedrive schaumburg, il 60173 note: dimensions shown are in millimeters. to convert millimeters to inches divide by 25.4. 1-800-55-omron omron canada, inc. 885 milner avenue scarborough, ontario m1b 5v 8 416-286-6465 9


▲Up To Search▲   

 
Price & Availability of G24-13-SNDDC24V

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X