  Datasheet File OCR Text:
  specification model dc voltage rated current rated power output line regulation load regulation setup, rise time note.7 hold up time (typ.) voltage range note.5 frequency range power factor (typ.) efficiency (typ.) ac current (typ.) input inrush current (typ.) leakage current safety standards note.6 emc immunity working temp. working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing over current note.4 over voltage over temperature 12v 7.2 ~12v 15v 9 ~ 15v 20v 12 ~ 20v 24v 14.4 ~ 24v 30v 18 ~ 30v 36v 21.6 ~ 36v 48v 28.8 ~ 48v 5a 4a 3a 2.5a 2a 1.67a 1.25a 60w 60w 60w 60w 60w 60.12w 60w 150mvp-p 150mvp-p 150mvp-p 150mvp-p 200mvp-p 250mvp-p 250mvp-p 4.0% 4.0% 4.0% 4.0% 4.0% 4.0% 4.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 2.0% 1.5% 1.0% 0.5% 0.5% 0.5% 0.5% 1000ms, 80ms / 115vac at full load 1000ms, 80ms / 230vac 16ms/230vac 16ms/115vac at full load 90 ~ 305vac 127 ~ 431vdc 47 ~ 63hz pf>0.97/115vac, pf 0.95/230vac, at full load (please refer to "powe r factor characteristic" curve) > pf>0.92/277vac 86% 87% 88% 89% 90% 90% 90% cold start 75a/230vac <0.75ma / 240vac 95 ~ 108% protection type : constant current limiting, recovers automatical ly after fault condition is removed compliance to en55015, en61000-3-2 class c ( 60% load) ; en61000-3-3 compliance to en61000-4-2,3,4,5,6,8,11; en61547, en55024, lig ht industry level(surge 2kv), criteria a -40 ~ +70 (refer to "derating curve") 20 ~ 95% rh non-condensing -40 ~ +80 , 10 ~ 95% rh 0.03%/ (0 ~ 50 ) 10 ~ 500hz, 5g 12min./1cycle, period for 72min. each along x, y, z axes 440.5khrs min. mil-hdbk-217f (25 ) 162.5*42.5*32mm (l*w*h) 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. constant current operation region is within 60% ~100% rated output vol tage. this is the suitable operation region for led related application s, but please reconfirm special electrical requirements for some specific syste m design. 5. derating may be needed under low input voltages. please check the static c haracteristics for more details. 6. suitable for indoor use or outdoor use without direct sunlight exposu re. please avoid immerse in the water over 30 minutes. 7. length of set up time is measured at cold first start. turning on/off the powe r supply may lead to increase of the set up time. 8. the power supply is considered as a component that will be operated in combi nation with final equipment. since emc performance will be affected by th e complete installation, the final equipment manufacturers must re- qualify emc directive on the complete installation again. 0.45kg; 32pcs/15.4kg/0.93cuft protection type : shut down and latch off o/p voltage, re-power on to recove r 60w single output switching power supply universal ac input / full rangebuilt-in active pfc function high efficiency up to 90% protections: short circuit / over current / over voltage / over temperature cooling by free air convection suitable for led lighting and moving sign applications compliance to worldwide safety regulations for lighting 3 years warranty (up to 305vac) suitable for dry / damp / wet locations fully isolated plastic casefully encapsulated with ip67 level (note.6) class power unit, no fg features : l p f - 6 0 s e r i e s ripple & noise (max.) note.2 voltage tolerance note.3 environment safety & emc protection 90 10 (rth2) protection type : shut down o/p voltage, re-power on to recover short circuit hiccup mode, recovers automatically after fault condition is remove d. ul8750, , j61347-1, j61347-2-13, ip67 approved en61347-1, en61347-2-13 independent ; design refer to ul60950-1, tuv en60950-1 54v 32.4 ~ 54v 1.12a 60.48w 350mvp-p 4.0% 0.5% 0.5% 42v 25.2 ~ 42v 1.43a 60.06w 250mvp-p 4.0% 0.5% 0.5% 90% 90% 15 ~ 17v 17.5 ~ 21v 23 ~ 27v 28 ~ 35v 34 ~ 40v 41 ~ 49v 54 ~ 63v 0.8a / 115vac 0.4a / 230vac 46 ~ 54v 59 ~ 66v file name:lpf-60-spec 2011-07-28 lpf-60-12 lpf-60-15 lpf-60-20 lpf-60-24 LPF-60-30 lpf-60 -36 lpf-60-42 lpf-60-48 lpf-60-54 withstand voltage isolation resistance emc emission i/p-o/p:3.75kvac i/p-o/p:100m ohms / 500vdc / 25 / 70% rh constant current region note.4 ip67 f m m 110 selv ( for 48v,54v only) ( except for 48v,54v )
mechanical specification load (%) 20 40 50 60 80 100 input voltage (v) 60hz 90 100 125 135 145 155 165 175 180 200 230 305 100 90 80 70 60 50 40 load (%) derating curve load (%) derating curve static characteristics ambient temperature ( ) load (%) 175 load (%) (horizontal) -30 0 15 30 0 40 50 -40 60 70 case no. lpf-60b unit:mm 230vac input only 3.6 3.5 3.5 3.6 3.5 3.5 sjtw 18awg 2c t case: max. case temperature. 43 60 t case 13 32 +v(red) -v(black) svt 18awg 2c ac/l(brown) ac/n(blue) 300 20 300 20 162.5 60w single output switching power supply l p f - 6 0 s e r i e s file name:lpf-60-spec 2011-07-28 fosc : 100khz detection pwm & pfc circuit o.l.p. emi filter rectifiers power switching filter & rectifiers +v -v i/p control o.v.p. & o.l.p. pfc circuit block diagram
0 . 8 4 0 . 8 5 0 . 8 6 0 . 8 7 0 . 8 8 0 . 8 9 0 . 9 0 . 9 1 0 . 9 2 0 . 9 3 0 . 9 4 0 . 9 5 0 . 9 6 0 . 9 7 0 . 9 8 0 . 9 9 1 5 0 % 6 0 % 7 0 % 8 0 % 9 0 % 1 0 0 % 2 7 7 v a c 2 3 0 v a c 1 1 5 v a c 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 277vac 230vac 115vac load efficiency (%) lpf-60 series possess superior working efficiency that up to 90% can be rea ched in field applications. efficiency vs load (48v model) pf load (60w) constant current mode there are two major kinds of led drive method "direct drive" and "with led driv er". typical led power supply i-v curve a typical led power supply may either work in "constant voltage mode (cv) or c onstant current mode (cc)" to drive the leds. mean well's led power supply with cv+ cc characteristic can b e operated at both cv mode (with led driver, at area (a) and cc m ode (direct drive, at area (b). driving methods of led module vo(%) 100 60 50 95 (max.) io (%) constant voltage area constant current area hiccup protection (a) (b) (c) power factor characteristic 60w single output switching power supply l p f - 6 0 s e r i e s file name:lpf-60-spec 2011-07-28


▲Up To Search▲   

 