Solid State Relays PCB, 1-Phase ZS Types RP 130 ...-.-05, RP 130 ...-.-12, RP 130 ...-.-24 * AC Solid State Relay for PCB mounting * Zero switching * Rated operational current: 3 or 5 AACrms * Non-repetitive voltage: Up to 850 Vp * Rated operational voltage: 240 V or 440 VACrms * 5 VDC logic compatible input * 12 and 24 VDC inputs for interfacing PLCs and other controls * Insulation: OPTO (input-output) 4000 VACrms Product Description The RP Solid State Relays from Carlo Gavazzi feature a very reliable design due to use of optotechnology together with high performance power semiconductors. Either 3 or 5 A relays are available for AC mains up to 400 VACrms. The zero switching version will work for resistive and inductive loads. With snubberless triacs as output devices, dV/dt limiting RC-networks are no longer required when switching inductive loads. Ordering Key Solid State Relay (PCB) Mounting type Switching mode Rated operational voltage Rated operational current Control voltage RP 130 240-5-12 Type Selection Switching mode 130: Zero switching Rated operational voltage 240: 230 VACrms 440: 400 VACrms Rated operational current 3: 3 AACrms 5: 5 AACrms Control voltage 05: 12: 24: 5 VDC 12 VDC 24 VDC Selection Guide Rated operational voltage Control voltage 5 VDC 12 VDC 230 VACrms 24 VDC 5 VDC 12 VDC 400 VACrms 24 VDC Rated operational current 3 AACrms RP 130 240-3-05 RP 130 240-3-12 RP 130 240-3-24 RP 130 440-3-05 RP 130 440-3-12 RP 130 440-3-24 5 AACrms RP 130 240-5-05 RP 130 240-5-12 RP 130 240-5-24 RP 130 440-5-05 RP 130 440-5-12 RP 130 440-5-24 Specifications are subject to change without notice (30.06.1999) 1 RP 130 ...-.-05, RP 130 ...-.-12, RP 130 ...-.-24 General Specifications RP 130 240-.-.. Operational voltage range Non-rep. peak voltage Zero voltage turn-on Operational frequency range Power factor Approvals CE-marking 24 to 280 VACrms 650 Vp 30 V 45 to 65 Hz 0.5 @ 230 VACrms UL, CSA, VDE Yes RP 130 440-.-.. 48 to 480 VACrms 850 Vp 50 V 45 to 65 Hz 0.5 @ 400 VACrms UL, CSA, VDE Yes Input Specifications RP 130 .40-.-05 Control voltage range Control voltage Pick-up voltage Drop-out voltage Input current @ rated voltage Reverse voltage Response time pick-up Response time drop-out 4 to 8 VDC 5 VDC 4 VDC 1 VDC 10 mADC 6 VDC 1/2 cycle 1/2 cycle RP 130 .40-.-12 8 to 16 VDC 12 VDC 8 VDC 1 VDC 10 mADC 6 VDC 1/2 cycle 1/2 cycle RP 130 .40-.-24 16 to 32 VDC 24 VDC 16 VDC 1 VDC 10 mADC 6 VDC 1/2 cycle 1/2 cycle Output Specifications RP 130 .40-3-0 Rated operational current AC 1 3 Arms AC 3 2.5 Arms Minimum operational current 20 mArms Rep. overload current t=1 s 6 Ap Non-rep. surge current t=20 ms 60 Ap Off-state leakage current @ rated voltage and frequency 1 mArms I2t for fusing t=1-10 ms 18 A2s Critical dI/dt 20 A/ms On-state voltage drop @ rated current 1.2 Vrms Critical dV/dt commutating 100 V/s Critical dV/dt off-state 100 V/s 100 V/s RP 130 .40-5-0 5 Arms 3 Arms 20 mArms 12 Ap 90 Ap 1 mArms 40 A2s 20 A/ms 1.2 Vrms 100 V/s Thermal Specifications RP 13. .40-3-0 Operating temperature Storage temperature Junction temperature Rth junction to case Rth junction to ambient -20 to +70C (-4 to +158F) -40 to +100C (-40 to +212F) 125C ( 257F) 20.5 K/W 33 K/W RP 13. .40-5-0 -20 to +70C (-4 to +158F) -40 to +100C (-40 to +212F) 125C ( 257F) 15.6 K/W 21 K/W 2 Specifications are subject to change without notice (30.06.1999) RP 130 ...-.-05, RP 130 ...-.-12, RP 130 ...-.-24 Insulation Input - Output Rated insulation voltage Insulation resistance Insulation capacitance Reference voltage according to VDE 0110 B Insulation group C 4000 VACrms 1010 8 pF Derating Curve Load current [A AC rms] ....................................... ....................................... ....................................... ....................................... ....................................... ........................................... ....................................... 6 5 4 ........................................... 500 VACrms, 600 VDC 3 2 1 0 ........................................... ........................................... ........................................... 0 10 20 30 40 50 60 70 Ambient temp. [C] Wiring Diagram Functional Diagram Mains input/ load output +3 Control input -4 IC 2 Line/load 1 Control input Load output/ mains input Dimensions 11M 9M 10.5 ** 3M 4M M = 1/10" = 2.54 mm Housing Specifications Weight Housing material Terminals Potting compound Approx. 10 g Noryl GFN 1, black Copper, tin-plated Flame-retardant polyurethane 43 * 25.4 * 1 6 ** 2 +3 4 * = 0.2 mm ** = 0.5 mm 4 x o1 Applications These relays can be used to switch heaters, motors, lights, valves or solenoids. When used at full load current, the relays must be placed vertically. If more than one relay is mounted, please allow a minimum distance of 20 mm in between for sufficient air cooling. 1M Accessories Varistors Fuses For further information refer to "General Accessories". Specifications are subject to change without notice (30.06.1999) 3 |
Price & Availability of RP130240-5-12
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |