Part Number Hot Search : 
MT351 05121 04597 APW706 4PH40 HFA3128 2D820M W21NM6
Product Description
Full Text Search
 

To Download MA1-B-34-430-1-A162-C Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 M-Series General Specifications
The low cost M-Series utilizes the hydraulic magnetic principle which provides accurate and reliable circuit protection even when exposed to extremely hot and/or cold application environments. Available in a choice of rocker actuator styles and colors, push button, push-pull, paddle, and baton style handle actuators, the Visi-Rocker(R) two-color actuators as well as non-illuminated or illuminated rocker versions with LED or neon bulbs. The exclusive Rockerguard(R) bezel helps prevent inadvertent actuation. "Wiping" contact design insures long term reliability. Various styling options allow design flexibility. Typical applications include power supplies, medical equipment, and telecommunications equipment. In addition, these breakers meet CSA Standard 22.2 No. 100 for the Generator & Welder markets.
Agency Certifications
UL Recognized UL Standard 1077
CSA Accepted Component Recognition Program as Protectors, Supplementary (Guide CCN/QVNU2, File E75596) VDE Certified Communications Equipment (Guide CCN/DITT, File E189195) TUV Certified
Component Supplementary Protector under Class 3215 30, File 047848 0 000 CSA Standard C22.2 No. 235 EN60934, VDE 0642 under File 10537 EN60934, under License No. R9671109
UL Listed UL Standard 489A
Electrical
Table A: Lists UL Recognized and CSA Accepted configurations & performance capabilities as a Component Supplementary Protector.
NOTES FOR TABLE A 1 Polarity Sensitive 2 Available only with Special Catalog Number. Consult Factory. 3 Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 30 Amps maximum 4 Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 60 Amps maximum
18
www.carlingtech.com
M-Series General Specifications
Electrical
Table B: Lists UL Recognized,CSA Accepted and TUV and VDE Certified configurations and performance capabilities as a Component Supplementary Protector.
NOTES FOR TABLE B 1 Polarity Sensitive 2 Available only with Special Catalog Number. Consult Factory. 3 Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 30 Amps maximum 4 TUV only, not VDE 5 Requires backup protection with a thermal magnetic circuit breaker rated 32 amps and having a Type C trip characteristic per EN60898/DIN VDE 0641 (C32A) for ratings greater than 15 amps, and a thermal magnetic circuit breaker rated 16 amps and having a Type C trip characteristic per EN60898/DIN VDE 0641 (C16A) for ratings 15 amps and less.
Table C: Lists UL489A Listed and TUV Certified configurations and performance capabilities for use in Communications Equipment.
NOTES FOR TABLE C 1. Available only with Special Caralog Number
www.carlingtech.com
19
M-Series General Specifications
Electrical
Maximum Voltage Current Ratings 125/250 VAC 50/60 Hz, 80 VDC (See Rating Tables.) Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00 thru 15.0 in 1 amp increments, 18.0, 20.0, 25.0, 30.0. Other ratings available - see Ordering Scheme. SPDT; 7A 250VAC, 7A (Res) 28VDC, 4A (Ind.) 28VDC, 0.25A 80VDC (Res) (silver contacts), 0.1A 125VAC (gold contacts). Minimum of 100 Megohms at 500 VDC. UL, CSA 1500V, 50/60 Hz for one minute between all electrically isolated terminals. M-Series Circuit Breakers comply with the 8mm spacing and 3750 V 50/60Hz dielectric requirements from hazardous voltage to operator accessible surfaces, per Publications IEC 380, 435, 950, EN 60950 and VDE 0805. Values from Line to Load Terminal based on Series Trip Circuit Breaker.
Mechanical
Endurance 10,000 ON-OFF operations @ 6 per minute with rated Current and Voltage. All M-Series Circuit Breakers will trip on overload, even when actuator is forcibly held in the ON position. The actuator moves positively to the OFF position when an overload causes the circuit breaker to trip.
Trip Free
Trip Indication
Auxiliary Switch Rating
Physical
Number of Poles 1 or 2 Internal Circuit Configurations Series with or without Auxiliary Switch. Switch Only with or without Auxiliary Switch. Weight Approximately 30 grams/pole (Approximately 1.07 ounces/pole) Standard Colors See Ordering Scheme.
Insulation Resistance Dielectric Strength
Resistance, Impedance
Environmental
Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Cond. I. Instantaneous curves tested at 80% of rated current. Vibration Withstands 0.060" excursion from 1055 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous curves tested at 80% of rated current. Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ + 25C to +65C, 80-98% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55C to +25C to +85C to +25C). Operating Temperature -40 C to +85 C Chemical Resistance Only the outside surfaces of the case and the handles may be cleaned with detergents or alcohol. Organic (hydrocarbon based) solvents are not recommended because they attack plastics. Caution should be taken when solvents are used to clean and remove flux from terminals. Lubricants should not be introduced into the handle/bushing openings.
Pulse Tolerance Curves
20
www.carlingtech.com
M-Series Handle/Pushbutton UL Recognized - Ordering Scheme
M M 1 - B - 34 - 260 - 1 - 1 B B - B - C
1 Series 2 Actuator 3 Poles 4 Circuit 5 Frequency & Delay 6 Current Rating 7 Terminal 8 Actuator Color 10 9 Front Panel Legend Hardware Plate 11 Bushing Color 12 Agency Approval
1 SERIES M 2 ACTUATOR 1
Handle M Paddle
N
Baton
Push Button T Push-Pull
U
Push To Reset
Push Button w/ Snap-In Mounting V Push-Pull
W
Push To Reset
6 CURRENT RATING (AMPERES)8 020 0.020 225 0.250 025 0.025 230 0.300 030 0.030 235 0.350 035 0.035 240 0.400 040 0.040 245 0.450 045 0.045 250 0.500 050 0.050 255 0.550 055 0.055 260 0.600 060 0.060 265 0.650 065 0.065 270 0.700 070 0.070 275 0.750 075 0.075 280 0.800 080 0.080 285 0.850 085 0.085 290 0.900 090 0.090 295 0.950 095 0.095 410 1.000 210 0.100 512 1.250 215 0.150 415 1.500 220 0.200 517 1.750 7 TERMINAL 8 1 Push-On 0.250 Tab (Q.C.) Screw 8-32 w/upturned lugs 210 10 Screw 8-32 (Bus Type) 3 8 ACTUATOR COLOR5 Handle Push-Button 1 A 2 B 3 C 4 D 5 E 6 F 8 H 9 FRONT PANEL HARDWARE 6 Handle No outer Panel Hardware A Knurled Nut Bright nickel B Bright nickel w/ locking ring C Black D Black w/ locking ring E Panel Dress Nut Bright nickel F Bright nickel w/ locking ring G Black H Black w/ locking ring J
420 522 425 527 430 435 440 445 450 455 460 465 470 475 480 485 490 495 610
2.000 2.250 2.500 2.750 3.000 3.500 4.000 4.500 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000
710 611 711 612 712 613 614 615 616 617 717 618 619 620 622 624 625 6309
10.500 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 17.500 18.000 19.000 20.000 22.000 24.000 25.000 30.000
3 POLES 1 One
2
Two A11 P12 Push-In Stud Printed Circuit Board
4 CIRCUIT 2 without Auxiliary Switch A Switch Only (No Coil), Maintained Contacts B Series Trip (Current) with Auxiliary Switch, Silver Contacts Terminal Type: P3 Switch Only, Maintained Contacts .060 Dia, Round Solder Turret Q3, 4 Switch Only, Maintained Contacts .058 Dia, Round Q.C. R3, 13 Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C. S3 Series Trip (Current) .060 Dia, Round Solder Turret T3, 4 Series Trip (Current) .058 Dia, Round Q.C. U3, 13 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C. with Auxiliary Switch, Gold Contacts 23, 4 Switch Only, Maintained Contacts .058 Dia, Round Q.C. 33, 13 Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C. 43,4 Series Trip (Current) .058 Dia, Round Q.C. 53, 13 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C. 5 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 DC Instantaneous 12 DC Short 14 DC Medium 20 50/60Hz Instantaneous 22 50/60Hz Short 24 50/60Hz Medium 30 DC, 50/60Hz Instantaneous 32 34 62 64 72 74 92 94 DC, 50/60Hz Short DC, 50/60Hz Medium 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, 50/60Hz Short, Hi-Inrush DC, 50/60Hz, Medium, Hi-Inrush
Actuator Color White Black Red Green Blue Yellow Orange
Push-Button 1
2
Notes: 1 One actuator is located in the center of each multi-pole breaker. Actuator codes V & W limited to single pole breakers only. 2 Switch Only circuits are not available with Push-To-Reset actuators. For Switch Only circuits, select Current Coil Rating from the following chart:
3
4 5 6 7 8 9 10 11 12 13
One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary Switch mounting is in pole one. Auxiliary Switch option limited to Series Trip and Switch Only circuits. Not available with back connect screw or push-in stud terminals. Mates with AMP .058" diameter pin receptacles including 60983-1 (gold plated) and 609832 (tin plated). Actuator color is only visible in the OFF position on Push-Pull actuators. All units except snap-in mounting have one hex nut installed on bushing for use behind the panel. Other colors available. Consult factory. TUV and VDE Certification above 15 amps is for 2-pole only and is limited to a max. of 25 amps. Screw Terminal or Push-In Stud recommended above 20 amps. 30 amp rating not available with delay's 30, 32, 34, 92 or 94. Screw Terminals are VDE certified only with use of ring terminal attached to wire. Terminal code A available with circuit codes A & B only. Printed circuit board available with UL recognized approval only. Auxiliary switch (flat Q.C.) available with UL recognized approvals only.
10 LEGEND PLATE / BUTTON MARKING Handle Actuator Legend Plate (Actuator Styles M & N) A No Legend Plate B ON - OFF Vertical C ON - OFF Horizontal D I - O Vertical E I - O Horizontal Push-Pull Actuator Button Cap (Actuator Styles T & V) 1 No Marking 2 Rated Amps Horizontal 3 Rated Amps Line Side Down 4 Rated Amps Line Side Up Push-to-Reset Actuator Button (Actuator Styles U& W) 1 No Marking 11 BUSHING COLOR 7 B Black 12 AGENCY APPROVAL 8 C UL Recognized & CSA Accepted D VDE Certified, UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted
www.carlingtech.com
21
M-Series Handle/Pushbutton UL489A/UL Recognized - Ordering Scheme
M M 1 - B - 14 - 620 - 1 - 1 B B - B - J
1 Series 2 Actuator 3 Poles 4 Circuit 5 Frequency & Delay 6 Current Rating 7 Terminal 8 Actuator Color 10 9 Front Panel Legend Hardware Plate 11 Bushing Color 12 Agency Approval
1 SERIES M 2 ACTUATOR 1
7 TERMINAL4 1 Push-On 0.250 Tab (Q.C.) 2 Screw 8-32 w/upturned lugs 3 Screw 8-32 (Bus Type) 8 ACTUATOR COLOR & LEGEND 5 Gloss Handle Push-Button 1 A 2 B 3 C 4 D 5 E 6 F 8 H 9 FRONT PANEL HARDWARE 6 Handle No outer Panel Hardware A Knurled Nut bright nickel B bright nickel w/ locking ring C black D black w/ locking ring E Panel Dress Nut bright nickel F bright nickel w/ locking ring G black H black w/ locking ring J
A10 P11
Push-In Stud Printed Circuit Board
Handle M Paddle
N
Baton
Push Button T Push-Pull
U
Push To Reset
Push Button w/ Snap-In Mounting V Push-Pull
Actuator Color White Black Red Green Blue Yellow Orange
W
Push To Reset
Push-Button 1
2
3 POLES 1 One 4 CIRCUIT without Auxiliary Switch B Series Trip (Current) with Auxiliary Switch, Silver Contacts S 2 Series Trip (Current) T 2,3 Series Trip (Current) U3, 12 Series Trip, Maintained Contacts with Auxiliary Switch, Gold Contacts 42,3 Series Trip (Current) 53, 12 Series Trip, Maintained Contacts 5 FREQUENCY & DELAY 12 DC Short 14 DC Medium 6 CURRENT RATING (AMPERES) 020 0.020 225 0.250 025 0.025 230 0.300 030 0.030 235 0.350 035 0.035 240 0.400 040 0.040 245 0.450 045 0.045 250 0.500 050 0.050 255 0.550 055 0.055 260 0.600 060 0.060 265 0.650 065 0.065 270 0.700 070 0.070 275 0.750 075 0.075 280 0.800 080 0.080 285 0.850 085 0.085 290 0.900 090 0.090 295 0.950 095 0.095 410 1.000 210 0.100 512 1.250 215 0.150 415 1.500 220 0.200 517 1.750
Terminal Type: .060 Dia, Round Solder Turret .058 Dia, Round Q.C. .080 Dia x .020 Flat Q.C.
.058 Dia, Round Q.C. .080 Dia x .020 Flat Q.C.
72 74
DC, Short, Hi-Inrush DC, Medium, Hi-Inrush
420 522 425 527 430 435 440 445 450 455 460 465 470 475 480 485 490 495 610
2.000 2.250 2.500 2.750 3.000 3.500 4.000 4.500 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000
710 611 711 612 712 613 614 615 616 617 717 618 619 620 622 624 625 630
10.500 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 17.500 18.000 19.000 20.000 22.000 24.000 25.000 30.000
10 LEGEND PLATE / BUTTON MARKING Handle Actuator Legend Plate (Actuator Styles M & N) A No Legend Plate B ON - OFF Vertical C ON - OFF Horizontal D I - O Vertical E I - O Horizontal Push-Pull Actuator Button Cap (Actuator Styles T & V) 8 1 No Marking 2 Rated Amps Horizontal 3 Rated Amps Line Side Down 4 Rated Amps Line Side Up Push-To-Reset Actuator Button Cap (Actuator Styles U & W) 8 1 No Marking 11 BUSHING COLOR 7 B Black 12 AGENCY APPROVAL 9 J UL489A Listed, TUV Certified M UL Recognized, CSA Accepted N UL Recognized, TUV Certified T UL489A Listed
Notes: 1 One actuator is located in the center of each multi-pole breaker. Actuator codes V & W limited to single pole breakers only. 2 One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary Switch mounting is in pole one. Auxiliary Switch option limited to Series Trip and Switch Only circuits. Not available with Back Connected Screw or Push-in Stud terminals. 3 Mates with AMP .058" diameter pin receptacles including 60983-1 (gold plated) and 60983-3 (tin plated). 4 Screw terminals or Push-in Stud recommended above 20 amps. 5 Actuator color is only visible in the OFF position on Push-Pull actuators. 6 All units have one hex nut installed on bushing for use behind the panel. 7 Other colors available. Consult factory. 8 Not available with UL489A Listed breakers. 9 TUV certified to 25 amps. UL Recognized, CSA Accepted and UL Listed to 30 amps. 10 Terminal code A available with circuit codes A & B only. 11 Printed circuit board available with UL recognized approval only. 12 Auxiliary switch (flat Q.C.) available with UL recognized approvals only.
22
www.carlingtech.com
M-Series Rocker UL Recognized - Ordering Scheme
M G 2 - B - 34 - 620 - 1
1 Series 2 Actuator 3 Poles 4 Circuit 5 Frequency & Delay 6 Current Rating 7 Terminal
H C 6-7-C
9 8 Illumination Actuator Color 10 Legend 11 Bezel Color 12 Agency Approval
1 SERIES M 2 ACTUATOR 1 Non-Illuminated single color A Angled B Flat
Two Color Visi-Rocker D Indicate ON E Indicate OFF
llluminated single color F Angled G Flat
8 ROCKER ILLUMINATION Non-illuminated Neon 5 without resistor, 120VAC/250VAC LED 7, 8 without resistor with resistor, 4-8 VDC with resistor, 9-16 VDC
A Neon B Red D E F
Green Glow8 C Green G H J
Amber K L M
3 POLES 1 One
2
Two
4 CIRCUIT 2 without Auxiliary Switch A Switch Only (No Coil), Maintained Contacts B Series Trip (Current) with Auxiliary Switch, Silver Contacts Terminal Type: P3 Switch Only, Maintained Contacts .060 Dia, Round Solder Turret Q3, 4 Switch Only, Maintained Contacts .058 Dia, Round Q.C. R3, 16 Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C. S3 Series Trip (Current) .060 Dia, Round Solder Turret T3, 4 Series Trip (Current) .058 Dia, Round Q.C. U3, 16 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C. with Auxiliary Switch, Gold Contacts 23, 4 Switch Only, Maintained Contacts .058 Dia, Round Q.C. 33, 16 Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C. 43,4 Series Trip (Current) .058 Dia, Round Q.C. 53, 16 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C. 5 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 DC Instantaneous 12 DC Short 14 DC Medium 20 50/60Hz Instantaneous 22 50/60Hz Short 24 50/60Hz Medium 30 DC, 50/60Hz Instantaneous 6 CURRENT RATING (AMPERES)10 020 0.020 225 0.250 025 0.025 230 0.300 030 0.030 235 0.350 035 0.035 240 0.400 040 0.040 245 0.450 045 0.045 250 0.500 050 0.050 255 0.550 055 0.055 260 0.600 060 0.060 265 0.650 065 0.065 270 0.700 070 0.070 275 0.750 075 0.075 280 0.800 080 0.080 285 0.850 085 0.085 290 0.900 090 0.090 295 0.950 095 0.095 410 1.000 210 0.100 512 1.250 215 0.150 415 1.500 220 0.200 517 1.750 7 TERMINAL 10 1 Push-On 0.250 Tab (Q.C.) 2 13 Screw 8-32 w/upturned lugs 13 Screw 8-32 (Bus Type) 3 32 34 62 64 72 74 92 94 DC, 50/60Hz Short DC, 50/60Hz Medium 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush DC, Short, Hi-Inrush DC,Medium, Hi-Inrush DC, 50/60Hz Short, Hi-Inrush DC, 50/60Hz, Medium, Hi-Inrush
9 ACTUATOR & LEGEND COLOR Solid Color Actuator Legend 1 White Black 2 Black White 3 Red White 4 Green White 5 Blue White 6 Yellow Black 7 Gray Black 8 Orange Black 6 Visi-Rocker Visi & Legend (remainder of rocker same color as bezel) 1 White 2 Black 3 Red 4 Green 5 Blue 6 Yellow 7 Gray 8 Orange Illuminated 8 Actuator Legend A Clear White B Red Transparent White C Green Transparent White D Amber Transparent White E Smoke Gray Transparent White F White Translucent Black 10 LEGEND11 1 No Legend 2 ON - OFF Vertical 3 ON - OFF Horizontal 4 I - O Vertical 11 BEZEL COLOR / STYLE 9 Color without Rockerguard White A Black B Gray G
5 6 7
I - O Horizontal Dual Vertical Dual Horizontal
with Rockerguard 1 2 7
12 AGENCY APPROVAL10 C UL Recognized & CSA Accepted D VDE Certified, UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted
Notes: 1 One actuator is located in the center of each multi-pole breaker. 2 For Switch Only circuits, select Current Coil Rating from the following chart:
420 522 425 527 430 435 440 445 450 455 460 465 470 475 480 485 490 495 610
2.000 2.250 2.500 2.750 3.000 3.500 4.000 4.500 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000
710 611 711 612 712 613 614 615 616 617 717 618 619 620 622 624 625 63012
10.500 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 17.500 18.000 19.000 20.000 22.000 24.000 25.000 30.000
3 4 5 6 7
8 9 10 11 12 13 14 15 16
A14 P15
Push-In Stud Printed Circuit Board
One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary Switch mounting is in pole one. Auxiliary Switch option limited to Series Trip & Switch Only circuits, & is not available in single pole illuminated breakers, or Back Connected Screw or Push-in Stud terminals. Mates with AMP .058" diameter pin receptacles: 60983-1 (gold plated) & 60983-2 (tin plated). For neon bulb applications at 120VAC @ 47K, 1/4 WATT and for 250VAC applications @ 150K, 1/4 WATT, external resistors must be supplied by customer. On Visi-Rocker breakers, Visi portion of rocker cannot be the same color as the bezel. For LED (DC or rectified AC) applications, LED is mounted in the center of the rocker actuator with electrical characteristics: 100 millicandela at 20mA; Maximum power dissipation = 75mW at 25C; Maximum forward current = 25mA; Typical forward voltage = 2.1V at 20mA; Typical reverse current = 100uA at 3V. Customer supplies the proper external resistor limiting current to these values. Rocker color for LED's and green neon lamp must be clear, smoke gray, white translucent or match color of LED or neon lamp. Other colors available. Consult factory. TUV and VDE Certified to 25 amps. UL Recognized and CSA Accepted to 30 amps. Screw Terminals or Push-in Stud recommended above 20 amps. TUV or VDE Certified must have I-O or Dual Legends. Legend required on Visi-Rocker breakers. 30 amp rating not available with delay's 30, 32, 34, 92 or 94. Screw Terminals are VDE certified only with use of ring terminal attached to wire. Terminal code A available with circuit codes A & B only. Printed circuit board available with UL recognized approval only. Auxiliary switch (flat Q.C.) available with UL recognized approvals only.
www.carlingtech.com
23
M-Series Rocker UL489A/UL Recognized - Ordering Scheme
M A 1 - B - 14 - 620 - 1 - A 1 6 - 2 - J
1 Series 2 Actuator 3 Poles 4 Circuit 5 Frequency & Delay 6 Current Rating 7 Terminal 9 8 Illumination Actuator Color 10 Legend 11 Bezel Color 12 Agency Approval
1 SERIES M 2 ACTUATOR 1 Non-Illuminated single color A Angled Two Color Visi-Rocker D Indicate ON llluminated single color F Angled
B E G
Flat Indicate OFF Flat
3 POLES 1 One 4 CIRCUIT2 without Auxiliary Switch B Series Trip (Current) with Auxiliary Switch, Silver Contacts S Series Trip (Current) T3 Series Trip (Current) U3, 13 Series Trip, Maintained Contacts with Auxiliary Switch, Gold Contacts 43 Series Trip (Current) 53, 13 Series Trip, Maintained Contacts 5 FREQUENCY & DELAY 10 DC Instantaneous 12 DC Short 6 CURRENT RATING (AMPERES) 020 0.020 225 0.250 025 0.025 230 0.300 030 0.030 235 0.350 035 0.035 240 0.400 040 0.040 245 0.450 045 0.045 250 0.500 050 0.050 255 0.550 055 0.055 260 0.600 060 0.060 265 0.650 065 0.065 270 0.700 070 0.070 275 0.750 075 0.075 280 0.800 080 0.080 285 0.850 085 0.085 290 0.900 090 0.090 295 0.950 095 0.095 410 1.000 210 0.100 512 1.250 215 0.150 415 1.500 220 0.200 517 1.750 7 TERMINAL 9 1 Push-On 0.250 Tab (Q.C.) 2 Screw 8-32 w/upturned lugs 3 Screw 8-32 (Bus Type) 8 ILLUMINATION Non-illuminated Neon 4 without resistor, 120VAC/250VAC LED without resistor 5, 7 with resistor, 4-8 VDC with resistor, 9-16 VDC 14 72 74
9 ACTUATOR & LEGEND COLOR Solid Color Actuator Legend 1 White Black 2 Black White 3 Red White 4 Green White 5 Blue White 6 Yellow Black 7 Gray Black 8 Orange Black 6 Visi-Rocker Visi & Legend (remainder of rocker same color as bezel) 1 White 2 Black 3 Red 4 Green 5 Blue 6 Yellow 7 Gray 8 Orange 7 Illuminated Actuator Legend A Clear White B Red Transparent White C Green Transparent White D Amber Transparent White E Smoke Gray Transparent White F White Translucent Black 10 LEGEND10 1 No Legend (Single Color or Illuminated Rocker Options Only) 2 ON - OFF Vertical 3 ON - OFF Horizontal 4 I - O Vertical 5 I - O Horizontal 6 Dual Vertical 7 Dual Horizontal 11 BEZEL COLOR / STYLE8 Color without Rockerguard White A Black B Gray G
Terminal Type .060 Dia, Round Solder Turret .058 Dia, Round Q.C. .080 Dia x .020 Flat Q.C.
.058 Dia, Round Q.C. .080 Dia x .020 Flat Q.C. DC Medium DC, Short,Hi-Inrush DC, Medium, Hi-Inrush
with Rockerguard 1 2 7
420 522 425 527 430 435 440 445 450 455 460 465 470 475 480 485 490 495 610
2.000 2.250 2.500 2.750 3.000 3.500 4.000 4.500 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000
710 611 711 612 712 613 614 615 616 617 717 618 619 620 622 624 625 630
10.500 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 17.500 18.000 19.000 20.000 22.000 24.000 25.000 30.000
12 AGENCY APPROVAL9 J UL489A Listed & TUV Certified M UL Recognized & CSA Accepted N TUV Certified, UL Recognized & CSA Accepted T UL489A Listed
A11 P12
Push-In Stud Printed Circuit Board
A Neon B Red D E F
Green Glow 7 C Green G H J
Amber K L M
Notes: 1 One actuator is located in the center of each multi-pole breaker. 2 One Auxiliary Switch is supplied per breaker. Auxiliary Switch option limited to Series Trip & Switch Only circuits, and is not available in single pole illuminated breakers, or with Back Connected Screw or Push-in Stud terminals. 3 Mates with AMP .058" diameter pin receptacles: 60983-1 (gold plated) & 60983-1 (tin plated). 4 For neon bulb applications at 120VAC @ 47K, 1/4 WATT and for 250VAC applications @ 150K, 1/4 WATT, external resistors must be supplied by customer. 5 For LED (DC or rectified AC) applications, LED is mounted in the center of the rocker actuator with electrical characteristics as follows: 100 millicandela at 20mA; Maximum power dissipation = 75mW at 25C; Maximum forward current = 25mA; Typical forward voltage = 2.1V at 20mA; Typical reverse current = 100uA at 3V. Customer supplies the proper external resistor limiting current to these values. 6 On Visi-Rocker breakers, Visi portion of rocker cannot be the same color as the bezel. 7 Rocker color for LED's and green neon lamp must be clear, smoke gray, white translucent or match color of LED or neon lamp. 8 Other colors available. Consult factory. 9 TUV Certified to 25 amps. UL Recognized, CSA Accepted and UL489A Listed to 30 amps. Screw Terminals recommended above 20 amps. 10 UL489A Listed must have ON-OFF or Dual legends. TUV Certified approvals must have I - O or Dual legends. 11 Terminal code A available with circuit codes A & B only. 12 Printed circuit board available with UL recognized approval only. 13 Auxiliary switch (flat Q.C.) available with UL recognized approvals only.
24
www.carlingtech.com
M-Series Handle - Circuit & Terminal Diagrams
Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance .020 [.51] unless otherwise specified.
www.carlingtech.com
25
M-Series Handle - Form & Fit Drawings
Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance 0.20 [.51] unless otherwise specified.
26
www.carlingtech.com
M-Series Handle - PC Terminal Diagrams
Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance .020 [.51] unless otherwise specified.
www.carlingtech.com
27
M-Series Pushbutton - Circuit & Terminal Diagrams
Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance .020 [.51] unless otherwise specified.
28
www.carlingtech.com
M-Series Pushbutton - Form & Fit Drawings
Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance 0.20 [.51] unless otherwise specified. 3 Available with Push-Pull or Push-to-Reset Actuators.
www.carlingtech.com
29
M-Series Push-Pull - PC Terminal Drawings
Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance .020 [.51] unless otherwise specified.
30
www.carlingtech.com
M-Series Rocker - Circuit & Terminal Diagrams
Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance .020 [.51] unless otherwise specified. 3 Schematic shown represents current trip circuit.
www.carlingtech.com
31
M-Series Rocker - Form & Fit Drawings
Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate OFF is opposite of indicate ON. 2 I-O, ON-OFF or dual legends available for vertical or horizontal mounting. For pole orientation with horizontal legend, rotate front view clockwise 90. 3 All dimensions are in inches [millimeters]. 4 Tolerance 0.20 [.51] unless otherwise specified.
32
www.carlingtech.com
M-Series Rocker - Supplementary Diagrams
www.carlingtech.com
33


▲Up To Search▲   

 
Price & Availability of MA1-B-34-430-1-A162-C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X