|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
APD-250M060 Vishay Dale Plasma Panel Display Monitors 250 Character Display, Drive Electronics, Controller Audio Alarm, Enclosure, Illuminated Control Panel FEATURES * * * * * * * * * High brightness - Sunlight readable. Auto/Manual brightness control. Wide viewing angle. Large character size. Fully self contained. Can be daisy chained. Audible alarm. Simple RS-232D interface. Compact size. STANDARD ELECTRICAL SPECIFICATIONS MIN. Voltage Current Frequency Interface (Per RS-232D) Logic One Logic Zero 3 -3 -- -- 12 - 12 VDC VDC 102 -- 57 TYP. 120 -- 60 MAX. 138 0.75 63 UNITS VAC A Hz The APD-250M060 monitor consists of 250 character DC plasma display panel, drive circuitry, display controller, audible alarm, enclosure and illuminated control panel. The enclosure may be mounted on a flat surface or in a suspended configuration. Its large characters, wide viewing angle and high brightness (with an auto or manual brightness control) provides excellent visibility in a wide range of ambient light conditions from total darkness to bright sunlight. Interfacing is via RS-232D at 9600 baud with no handshaking (a FIFO buffer is used to capture data when the display is busy). The byte format is 1 start bit, 8 data bits and 1 stop bit. As each monitor receives a data byte, it automatically sends it to the next unit in the daisy (up to 8 monitors maximum) chain. Returning data from the monitors are handled in the same way. A front panel bypass switch is provided to allow the operator to instantly route the input channel to the output channel in the event of a monitor failure. Single byte and two byte commands allow simplified code generation, yet accomplish complex display tasking such as scrolling or inserting lines and characters. The character generator is an 8K x 8 bit EPROM which has capacity for two 256 character sets. It is preprogrammed with two ASCII character sets (128 characters each including control codes). Other character sets may be factory programmed per the user's special requirements. The audio alarm operation is under the complete control of the host system. The alarm is a warble of two tones which can be user adjusted. The volume may be adjusted by the operator from 65 to 85 dbA by a front panel control. User controls are power, self test, auto/manual brightness adjustment, I/O bypass, alarm volume control and alarm acknowledge. The APD-250M060 monitor is a DTE device and will operate with a host that is either a DTE or DCE type device. Interface is through standard DB25, RS-232D connectors. Document Number: 37036 Revision 05-Dec-00 MECHANICAL SPECIFICATIONS Dimensions: 16" [406.40mm] W x 15" [381.0mm] H x 6" [152.40mm] D. Weight: 30 pounds [13.61 kilogram]. OPTICAL SPECIFICATIONS Viewing Area: 12.42" [315.47mm] W x 8.17" [207.52mm] H. Number of Characters: 250. Character Size: 0.420" [10.67mm] W x 0.610" [15.49mm] H. Luminance: 50 foot lamberts maximum (through the filter). Contrast Ratio: 3:1 minimum at 2000 fc ambient. Color: Neon orange. Viewing Angle: 120 cone. AUDIO SPECIFICATIONS Sound Pressure: 60 to 85 dbA at 3 feet (1 meter). Warble: Two alternating tones. www.vishay.com 2 APD-250M060 Vishay Dale DIMENSIONAL CONFIGURATIONS [Numbers in brackets indicate millimeter] Plasma Display 16.00 [406.40] 12.42 [315.47] Removable Bracket MONITOR FUNCTION SUMMARY CONTROL CODES NO OPERATION BELL CURSOR LEFT CURSOR RIGHT CURSOR DOWN/LINE FEED CURSOR UP CLEAR SCREEN AND CURSOR HOME CARRIAGE RETURN CURSOR HOME CHARACTER INSERT CHARACTER DELETE ALTER CURSOR COLUMN POSITION CURSOR COLUMN ADDRESS (0-18) CURSOR ON ALTER CURSOR ROW POSITION CURSOR ROW ADDRESS (0-9) CURSOR OFF START OFF BLINK FIELD LINE INSERT LINE DELETE END OF BLINK FIELD ENABLE ALARM DISABLE ALARM POLL BROADCAST TO ALL MONITORS MONITOR SELECT ID NUMBER (0-7) DESELECT ALL MONITORS ESCAPE CONTROL CODES ERASE TO END OF LINE ERASE TO END OF SCREEN ERASE LINE ERASE LINE AND CARRIAGE RETURN SCROLL MODE OVERWRITE OF LAST SCREEN CHARACTER AUTO WRAP BLANK MONITOR/SCREEN SAVER UNBLANK MONITOR SELECT ALTERNATE CHARACTER SET *SELECT STANDARD CHARACTER SET DISPLAY CONTROL CHARACTERS *DISABLE CONTROL CHARACTERS DISPLAY START CONFIDENCE TEST *DISABLE CONFIDENCE TEST (ANY CODE) RESET 1B, 0D 1B, 18 1B, 13 1B, 25 1B, 1A 1B, 1C 1B, 20 1B, 11 1B, 12 1B, 0F 1B, 0E 1B, 1E 1B, 26 1B, 1F 00 1B, 19 DATA 00 07 08 09 0A 0B 0C 0D OE OF 10 11 ## 12 13 ## 14 15 16 17 18 19 1A 1C 1D 1E nn 1F 8.17 [207.52] Automatic Light Control Sensor Power Switch Alarm Speaker Control Panel (See detail) Acknowledge Switch Control Panel Access Door DISPLAY BRIGHTNESS SELF TEST NORMAL ALARM VOLUME MANUAL AUTO BYPASS SELECTOR OFF DURATION WARBLE FREQUENCY 1.50 [38.10] 15.0 [381.0] 6.0 [152.40] *Indicates power up condition. All codes are hexadecimal format. PIN DESCRIPTION CONNECTOR J1 PIN SIGNAL 1 Ground (Shield) 2 Transmit Data 3 Receive Data 7 Ground 4, 5, 6, 8-25 No connection J2 1 Ground (Shield) 2 Receive Data 3 Transmit Data 7 Ground 4, 5, 6, 8-25 No connection WARNING: Wrong connections may cause permanent damage to the monitor and host system. Document Number: 37036 Revision 05-Dec-00 ORDERING INFORMATION DESCRIPTION PART NUMBER Complete Display Monitor and Alarm System ..... APD-250M060 www.vishay.com 3 |
Price & Availability of APD-250M060 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |