JMK, Inc Operating voltage = 50 Vdc Operating current = 12.0 Amp Operating temperature = (-40)--70C Diel. withstanding (line - case) = 1500 Vdc (1.0 Minute) Diel. withstanding (line - line) = 100 Vdc (1.0 Minute) HH-1545-12 LINE 1 3 2 5 LOAD 4 Order P/N: HH-1545-12 INSERTION LOSS (db) HH-1545-12 AMBIENT TEMPERATURE VS OPERATING CURRENT 80 CM 70 60 DM 50 40 30 90 80 OPERATING TEMP (DEG C) 70 60 50 40 10 11 12 13 14 15 16 20 10 0 .01 .02 .04 .07 .1 .2 .4 .7 1 2 4 7 10 20 40 70 100 FREQUENCY (MEGAHERTZ) CURRENT (AMPS) 0.25 0.25 2.30 1 1.90 4 2.40 2 3 0.50 0.080 0.190 0.025 0.75 2.80 USA EUR JMK Inc 15 Caldwell Dr. Amherst, NH 03031 JMK Ltd Dumbarton G82 2TS Scotland UK PH: 603 886-4100 FX: 603 886-4115 email: info@jmkfilters.com PH: 44-(0) 1389-751841 FX: 44-(0) 1389-751841 5 |