1 HORSE-POWER COMPACT POWER RELAYS JA-RELAYS 30.1 1.185 34.7 1.366 30.1 1.185 34.7 1.366 FEATURES 28.5 1.122 28.5 1.122 TMP type TM type mm inch * High switching capacity -- 55 A inrush, 15 A steady state inductive load (1 Form A) * Particularly suitable for air conditioners, dish washers, microwave ovens, ranges, central cleaning systems, copiers, facsimiles, etc. * Two types available "TM" type for direct chassis mounting "TMP" type for PC board mounting * TV-rated types available * TUV also approved SPECIFICATIONS Contact Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Maximum switching power Rating (resistive Maximum switching voltage load) Max. switching current Mechanical (at 180 cpm.) 1 Form A (Inrush 55 A, Expected Steady 15 A 250 VAC life (min. cos = 0.7) Electrical operations) (at 20 cpm.) 1 Form B, 1 Form C (15 A 250 VAC, cos = 1) 1 Form, A, 1 Form B, 1 Form C Characteristics 30 m Silver alloy 3,750 VA 250 V AC 15A 5x106 105 Maximum operating speed Initial insulation resistance*1 Between open contacts Initial breakdown voltage*2 Between contacts and coil Initial surge voltage between contacts and coil*3 Operate time*4 (at 20C) (at nominal voltage) Release time (without diode)*4 (at 20C) (at nominal voltage) Temperature rise (at 50C) (resistive) Shock resis- Functional*6 tance Destructive*7 Vibration resistance Functional*8 Destructive Coil Nominal operating power Minimum operating power Remarks DC type AC type DC type AC type * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage" section *2 Detection current: 10mA *3 Wave is standard shock voltage of 1.2 x 50s according to JEC-212-1981 *4 Excluding contact bounce time *5 For the AC coil types, the operate/release time will differ depending on the phase. *6Half-wave pulse of sine wave: 11ms; detection time: 10s TYPICAL APPLICATIONS Air conditioners, microwave ovens, load management equipment, copiers, process control equipment w w w 1.4 VA (50 Hz)/1.3 VA (60 Hz) 0.77 W 0.90 VA (50 Hz)/0.84 VA (60 Hz) t a .D 5x105 1.2 W Ex. JA S a e h U t4 e .c m o 20 cpm. Min. 100 M at 500 V DC 1,500 Vrms 2,000 Vrms Min. 5,000 V Approx. 10 ms*5 Approx. 2 ms*5 Max. 70C 98 m/s2 {10 G} 980 m/s2 {100 G} 88.2 m/s2 {9 G}, 10 to 55 Hz at double amplitude of 1.5 mm 88.2 m/s2 {9 G}, 10 to 55 Hz at double amplitude of 1.5 mm -10C to +50C +14F to +122F 5 to 85%R.H. Approx. 44 g 1.55 oz Ambient Conditions for operation, transport and storage*9 temp. (Not freezing and condensHumidity ing at low temperature) Unit weight *7 Half-wave pulse of sine wave: 6ms *8 Detection time: 10s *9 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24). ORDERING INFORMATION 1a TM DC12V P Contact arrangement 1c: 1 Form C 1a: 1 Form A 1b: 1 Form B Mounting classification Coil voltage TM: Solder Terminal TMP: Solder Teminal and PCB Teminal DC 12, 24 V AC 12, 24, 115 V (Notes) 1. For UL/CSA recognized types, add suffix UL/CSA. (Notes) 2. Standard packing Carton: 20 pcs.; Case: 200 pcs. 110 w w w .D at aS Nil: Standard type P: Up-graded contact rating type (See next page) ee h 4U t om .c Classification JA COIL DATA DC Type at 20C 68F Nominal voltage 12 V DC 24 Pick-up voltage (max.) 9.6 V DC 19.2 Drop-out* voltage (min.) 1.2 (0.6*) V DC 2.4 (1.2*) Coil resistance, W (10%) 120 480 Nominal operating current, mA (10%) 100 50 Nominal operating power 1.2 W 1.2 Maximum allowable voltage (at 50C) 13.2 V DC 26.4 AC Type at 20C 68F Nominal voltage 12 V AC Pick-up voltage (max.) 9.6 V AC Drop-out* voltage (min.) 3.6 V AC Coil resistance, W (10%) -- -- -- Nominal operating current, mA (10%) 50 Hz 60 Hz 117 108 58 54 12 11 Nominal operating power 50 Hz 60 Hz 1.4 VA 1.3 VA 1.4 VA 1.3 VA 1.4 VA 1.3 VA Maximum allowable voltage (at 50C) 13.2 V DC 26.4 126.5 24 19.2 7.2 115 92 34.5 * Drop-out voltage for 1 Form B type is 5% of nominal voltage. NOTES 1. The range of coil current for AC relay is 15% (60 Hz). For DC relay it is 10% at 20C 68F. 2. The JA relay will operate in a range from 80% to 110% of the nominal coil voltage. It is however, recommended that the relay be used in the range of 85% to 110% of the nominal coil voltage, with the temporary voltage variation taken into consideration. 3. When the operating voltage of AC relays drops below 80% of the nominal coil voltage. The relay will generate a considerable amount of heat which is not recommended for maximum efficiency. 4. The coil resistance of DC types is the measured value of the coil at a temperature of 20C (68F). If the coil temperature changes by 1C. The measured value of the coil resistance should be increased or decreased by 0.4%. ADDITIONAL SERIES 1. Following up-graded contact rating types recognized by UL are available. (For use in office appliances) Suffix Contact arrangement 1 Form C 1 Form A 1 Form B P (Ex. JA 1a - TM - DC12V -P) Contact arrangement 1 Form A 2. TV-Rated Series Suffix UL TV TV-5 CSA TV TV-5 25 A 250 V AC, 1 HP 125, 250 V AC 25 A 250 V AC, 1 HP 125, 250 V AC 25 A 250 V AC, 1 HP 125, 250 V AC mm inch DIMENSIONS TM 4.5 .177 Schematic (Bottom view) COM 1 Form A COM N.O. 50 1.969 43.5 1.713 COM 1 Form B R 2. 2 N.C. 5 30.1 1.185 34.7 1.366 2 .079 37.8 6.5 .256 1.488 9.3 .366 COM 1 Form C N.C. N.O. 12.7 .500 FASTON 250 21.5 .846 FASTON 187 Terminals--.187" quick connect terminals for coil and .250" for contacts Mounting hole location COM 43.50.1 1.713.004 NC NO Remarks Above dimensions are for 1 Form C type. For 1 Form A type, NC terminal is removed For 1 Form B type, NO terminal is removed. General tolerance: 0.3 .012 2-4.50.1 DIA. 2-.177.004 DIA. Tolerance: 0.1 .004 111 JA TMP 0.50.1 .020.004 4.5 .177 0.50.1 .020.004 mm inch Schematic 1 Form A Bottom view COM Top view COM 50 1.969 43.5 1.713 COM N.O. Bottom view COM Top view COM 25 25.4 1.000 30.1 1.185 0.80.1 .031.004 34.7 1.366 14 .551 1.5 .059 2. 1 Form B 3.5 .138 N.C. 2 .079 37.8 1.488 9.3 .366 Bottom view COM Top view COM R 1 Form C N.O. N.C. 12.7 .500 FASTON 250 21.5 .846 Terminals--PC board terminals for coils and .250" quick connect terminals forcontacts COM Mounting hole location NC NO General tolerance: 0.3 .012 2-4.50.1 DIA. 2-.177.004 DIA. 3-20.1 DIA. 3-.079.004 DIA. 43.50.1 1.713.004 140.1 .551.004 Remarks Above dimensions are for 1 Form C type. For 1 Form A type, NC terminal is removed For 1 Form B type, NO terminal is removed. 25.40.1 1.000.004 Tolerance: 0.1 .004 REFERENCE DATA 1. Maximum value for switching capacity (Common for 1a, 2b, and 1c) 20 Contact current, A 10 Temperature rise, C 5 Life x104 DCresistive load 100 50 250 V AC resistive load 30 V DC resistive load 80 60 40 20 AC resistive load 2. Life curve (Common for 1a, 1b, and 1c) 3.-(1) Coil temperature rise (1a-AC type) Point measured: Inside the coil Ambient temperature: 25C 77F 500 100 Contact current 15A 10A 0A 1 0.5 0 30 50 100 200 400 500 Contact voltage, V 0 2 4 6 8 10 12 14 16 18 20 22 Contact current, A 0 80 90 100 110 120 Coil applied voltage, %V 3.-(2) Coil temperature rise (1a-DC type) Point measured: Inside the coil Ambient temperature: 25C 77F 100 Temperature rise, C 4.-(1) Operate time (1a-AC type) 4.-(2) Operate time (1a-DC type) 20 18 Operating time, ms Contact current 15A Operating time, ms 20 18 16 14 12 10 8 6 Min. 4 2 80 90 100 110 120 0 80 90 100 110 120 Coil applied voltage, %V Max. Min. 80 60 40 20 16 14 12 10 8 6 4 2 Max. 10A 0A 0 80 90 100 110 120 0 Coil applied voltage, %V Coil applied voltage, %V 112 JA 5.-(1) Release time (1a-AC type) 20 18 Release time, ms 16 14 12 10 8 6 4 2 0 80 90 100 110 120 Min. 0 80 90 100 110 120 1 Max. Release time, ms 4 3 2 Max. Min. 5.-(2) Release time (1a-DC type) 5 Coil applied voltage, %V Coil applied voltage, %V 6.-(1) Electrical life (15 A 250 V AC resistive) 1. Tested sample: JA1c-TMP-AC115V 2. Load: 15 A 250 V AC resistive load 3. Cycle rate: 20 cpm. 4. Circuit: TEST RESULT: 1. Pick-up and drop-out voltage 80 70 60 Voltage, *% 50 40 30 20 10 0 10 30 4 No. of operations, x10 50 Drop-out voltage Pick-up voltage Max. Max. Min. Min. 2. Contact resistance Contact resistance, m 30 Max. Mean value Min. 10 30 No. of operations, x104 50 N.C. contact 10 0 30 N.C. N.C. 250 V AC 15 A 15 A Contact resistance, m 10 0 10 N.C. contact Mean value 50 30 No. of operations, x104 * This shows percent rate against nominal coil voltage. 3. No abnormality was observed in either insulation resistance or breakdown voltage. 2. Contact resistance 10 6.-(2) Electrical life (15 A 250 V AC Motor simulated load) 1. Tested sample: JA1A-TM-DC12V 2. Load: 250 V AC inductive load (cos = 0.7) 15 A steady and 55 A (0.3s*) inrush current 3. Cycle rate: 20 cpm. 4. Circuit: TEST RESULT: 1. Pick-up and drop-out voltage 10 9 8 Voltage, % 7 6 5 4 3 Pick-up voltage Max. Mean value Min. Contact resistance, m N.O. contact Max. Mean value Min. 5 N.O. 250 V AC R L R L 2 1 0 Drop-out voltage Max. Mean value Min. 0 10 5 10 4 5 4 No. of operations, x10 No. of operations, x10 3. No abnormality was observed in either insulation resistance or breakdown voltage. For Cautions for Use, see Relay Technical Information (Page 11 to 39). 113 |
Price & Availability of JA1A-TM-DC12
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |