![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
INSTRUCTION MANUAL RTD INPUT LIMIT ALARM Thank you for choosing M-System. Before use, check specifications on the unit label. If you have any problems or questions with the product, please contact M-System's Sales Office or representatives. model MP1400 through MP1423 Adjustments *Setpoint The MP1400 Series has five styles of setpoint adjustment: MP14X0 Top-accessed, 3-turn screw(s) MP14X2 Remote dial connection(s), 1k to 100k ohms MP14X3 DC-programmable, 0 to 1V The setpoint is adjustable over the entire input span. A) Set deadband at its minimum (fully counterclockwise) before adjusting the setpoint. B) With the specified trip Resistance/RTD input applied, adjust setpoint until the relay trips. For Hi trip calibration, start with the setpoint above the desired trip. For Lo trip calibration start below the desired trip. *Deadband The deadband is independently adjustable for both setpoints in dual alarms. A) Set deadband at its minimum (fully counterclockwise). Set setpoint to desired trip. B) Adjust Resistance/RTD input until relay trips. C) Re-adjust deadband to 100% (fully clockwise). D) Set Resistance/RTD input to desired deadband position. E) Slowly adjust deadband until relay untrips. *Transmitter Output (Option T) A) With the specified minimum input applied, adjust Zero for 0.00V at the transmitter output. B) With the specified maximum input applied, adjust Span for 1.00V. Repeat A) to B) for best accuracy. General Description The M-PAC Model MP1400 through MP1423 accept 2- or 3-wire RTD inputs and provide relay contact closure(s) at a preset input level. The MP1400 Series reflects three styles of output selection: MP1400 - MP1403 Single (Hi) trip, non-latching (DPDT, 3A) MP1410 - MP1413 Single (Hi) trip, latching (DPDT, 3A) MP1420 - MP1423 Dual (Hi/Lo) trip, non-latching (SPDT, 3A) *Upscale burnout protection as standard *Failsafe operation available *Deadband adjustable from 1 to 100% www..com *Indicator LED provided Installation [Scale: mm(inch)] *Operating temperature: -5 to +60C (23 to 140F) *Operating humidity: 30 to 90% RH (non-condensing) Keep away from water, corrosive gas, dust and vibration. DIN rail mounting available for 11-pin-base modules. Use DIN rail of 35 mm width. *11-Pin Base 55 (2.17) min. Relay Protection 40 0.2 (1.57 .01) 40 0.2 (1.57 .01) 2-M4 SCREW *Output Relay Rating 30V DC @3A (resistive load) or 120V AC @3A (coso=1) For maximum relay life with inductive loads, external protection is recommended. Refer to the Figures below. *DC Line Powered Loop Place a diode across the load. DC Power *20-Pin Base 85 (3.35) min. Limit Alarm LOAD 56 0.2 (2.20 0.01) 56 0.2 (2.20 0.01) 2-M4 SCREW *AC Line Powered Loop Place a varistor or CR spark killer across the load. AC Power LOAD Limit Alarm Spark Quenching Circuit Terminal Connections Make wiring to terminals as shown in the Tables in Page 2 through 3. Use the socket provided with the module. P. 1 / 3 EM-9804 Rev.3 MP1400 through MP1423 External Dimensions [Scale: mm(inch)] *11-Pin Base CLAMP (top & bottom) 20 (.79) 7.8 (.31) DIN RAIL 35mm wide 35.4 (1.39) 8 7 6 5 4 80 (3.15) 2-4.5 (.18) dia. MTG HOLE 25 (.98) deep 11-M3.5 SCREW 9 10 11 1 3 2 50 (1.97) 103 (4.06) 132 (5.20) [3.3 (.13)] 40 (1.57) 50 (1.97) www..com *20-Pin Base 8 (.31) 9 8 7 6 5 4 2 3 20 1 2-4.5 (.18) dia. MTG HOLE 11 10 13 12 14 15 16 17 18 19 103 (4.06) 80 (3.15) 136 (5.35) 33 (1.30) 20-M3.5 SCREW 56 (2.20) 71 (2.80) Terminal Assignment *Single Output MP1400 1 2 3 4 5 6 7 8 9 10 11 POWER (Hot/+) RTD Comp Lead POWER (Neu/-) RTD Hi RTD Lo N.O. COM * N.C. * N.O. COM N.C. MP1400 w/Option T 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 POWER (Hot/+) No Connection POWER (Neu/-) No Connection No Connection No Connection No Connection SP Xmtr + RTD Lo Xmtr Common RTD Hi Proc Xmtr + N.O. COM * N.C. * No Connection N.O. COM N.C. RTD Comp Lead MP1402 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 POWER (Hot/+) No Connection POWER (Neu/-) No Connection SP Pot CCW SP Pot W SP Pot CW No Connection RTD Lo No Connection RTD Hi No Connection N.O. COM * N.C. * No Connection N.O. COM N.C. RTD Comp Lead MP1402 w/Option T 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 POWER (Hot/+) No Connection POWER (Neu/-) No Connection SP Pot CCW SP Pot W SP Pot CW SP Xmtr + RTD Lo Xmtr Common RTD Hi Proc Xmtr + N.O. COM * N.C. * No Connection N.O. COM N.C. RTD Comp Lead MP1403 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 POWER (Hot/+) No Connection POWER (Neu/-) No Connection SP - SP + No Connection No Connection RTD Lo No Connection RTD Hi No Connection N.O. COM * N.C. * No Connection N.O. COM N.C. RTD Comp Lead MP1403 w/Option T 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 POWER (Hot/+) No Connection POWER (Neu/-) No Connection SP - SP + No Connection SP Xmtr + RTD Lo Xmtr Common RTD Hi Proc Xmtr + N.O. COM * N.C. * No Connection N.O. COM N.C. RTD Comp Lead KEYS N.O. = Normally Open COM = Common N.C. = Normally Closed Proc = Process Xmtr = Transmitter SP = Setpoint W = Wiper CW = Clockwise CCW = Counterclockwise *Pins used for Option V 20-pin = 14(+) - 15(-) 11-pin = 7(+) - 8(-) P. 2 / 3 EM-9804 Rev.3 101 (3.98) 65 (2.56) 2-M3 SCREW (for module) 80 (3.15) MP1400 through MP1423 *Latching Output MP1410 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 POWER (Hot/+) No Connection POWER (Neu/-) Latch Reset No Connection No Connection No Connection No Connection RTD Lo No Connection RTD Hi No Connection N.O. COM * N.C. * Latch Reset N.O. COM N.C. RTD Comp Lead MP1410 w/Option T 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 POWER (Hot/+) No Connection POWER (Neu/-) Latch Reset No Connection No Connection No Connection SP Xmtr + RTD Lo Xmtr Common RTD Hi Proc Xmtr + N.O. COM * N.C. * Latch Reset N.O. COM N.C. RTD Comp Lead MP1412 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 POWER (Hot/+) No Connection POWER (Neu/-) Latch Reset SP Pot CCW SP Pot W SP Pot CW No Connection RTD Lo No Connection RTD Hi No Connection N.O. COM * N.C. * Latch Reset N.O. COM N.C. RTD Comp Lead MP1412 w/Option T 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 POWER (Hot/+) No Connection POWER (Neu/-) Latch Reset SP Pot CCW SP Pot W SP Pot CW SP Xmtr + RTD Lo Xmtr Common RTD Hi Proc Xmtr + N.O. COM * N.C. * Latch Reset N.O. COM N.C. RTD Comp Lead MP1413 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 POWER (Hot/+) No Connection POWER (Neu/-) Latch Reset SP - SP + No Connection No Connection RTD Lo No Connection RTD Hi No Connection N.O. COM * N.C. * Latch Reset N.O. COM N.C. RTD Comp Lead MP1413 w/Option T 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 POWER (Hot/+) No Connection POWER (Neu/-) Latch Reset SP - SP + No Connection SP Xmtr + RTD Lo Xmtr Common RTD Hi Proc Xmtr + N.O. COM * N.C. * Latch Reset N.O. COM N.C. RTD Comp Lead KEYS N.O. = Normally Open COM = Common N.C. = Normally Closed Proc = Process Xmtr = Transmitter SP = Setpoint W = Wiper CW = Clockwise CCW = Counterclockwise *Pins used for Option V 20-pin = 14(+) - 15(-) www..com *Dual Output MP1420 1 2 3 4 5 6 7 8 9 10 11 POWER (Hot/+) RTD Comp Lead POWER (Neu/-) RTD Hi RTD Lo N.O. COM * N.C. * N.O. COM * N.C. * Hi Set MP1420 w/Option T 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 POWER (Hot/+) No Connection POWER (Neu/-) No Connection No Connection Xmtr Common No Connection No Connection RTD Lo Proc Xmtr + RTD Hi Lo SP Xmtr + N.O. COM * Lo Set N.C. * Hi SP Xmtr + N.O. COM * Hi Set N.C. * RTD Comp Lead MP1422 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 POWER (Hot/+) No Connection POWER (Neu/-) Lo SP Pot CW Lo SP Pot W SP Pots CCW Hi SP Pot W Hi SP Pot CW RTD Lo No Connection RTD Hi No Connection N.O. COM * Lo Set N.C. * No Connection N.O. COM * Hi Set N.C. * RTD Comp Lead MP1422 w/Option T 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 POWER (Hot/+) No Connection POWER (Neu/-) Lo SP Pot CW Lo SP Pot W SP Pots CCW/ Xmtr Common Hi SP Pot W Hi SP Pot CW RTD Lo Proc Xmtr + RTD Hi Lo SP Xmtr + N.O. COM * Lo Set N.C. * Hi SP Xmtr + N.O. COM * Hi Set N.C. * RTD Comp Lead MP1423 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 POWER (Hot/+) No Connection POWER (Neu/-) No Connection Lo SP + SP Common Hi SP + No Connection RTD Lo No Connection RTD Hi No Connection N.O. COM * Lo Set N.C. * No Connection N.O. COM * Hi Set N.C. * RTD Comp Lead MP1423 w/Option T 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 POWER (Hot/+) No Connection POWER (Neu/-) No Connection Lo SP + SP Common/ Xmtr Common Hi SP + No Connection RTD Lo Proc Xmtr + RTD Hi Lo SP Xmtr + N.O. COM * Lo Set N.C. * Hi SP Xmtr + N.O. COM * Hi Set N.C. * RTD Comp Lead KEYS N.O. = Normally Open COM = Common N.C. = Normally Closed Proc = Process Xmtr = Transmitter SP = Setpoint W = Wiper CW = Clockwise CCW = Counterclockwise *Pins used for Option V 20-pin: Hi Set = 19(+) - 18(-) Lo Set = 15(+) - 14(-) 11-pin: Hi Set = 7(+) - 8(-) Lo Set = 10(+) - 11(-) Lo Set *Terminal No. for 11-Pin Base 8 7 6 5 4 *Terminal No. for 20-Pin Base 9 8 7 6 5 4 2 3 20 1 9 10 11 1 3 2 11 10 13 12 14 15 16 17 18 19 M-SYSTEM WARRANTY M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System's sole liability, and purchaser's exclusive remedies, under this warranty are, at M-System's option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this warranty. To submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original sales invoice. THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES OF ANY KIND WHATSOEVER. M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: info@m-system.co.jp P. 3 / 3 EM-9804 Rev.3 |
Price & Availability of MP140X
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |