![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
CAR1212FP Series 1200 Watt +12V Front End Power Supply Features: Measures 11.20 x 4.00 x 1.65" / 284.5 x 101.6 x 41.9mm 12V Power for Powering Non-Isolated POL Converters Hot Swap / N+1 Redundant Active Single Wire Current Sharing Remote On/Off Control International Safety Approvals - UL, CSA, CE Mark (LVD) TUV FEATURES High Power Density 16W/in3 1U High Form Factor 5VSB Standby Voltage I 2C Digital Control & Monitoring SPECIFICATIONS Input Voltage Range Input Current Maximum Inrush Current Input Protection Power Factor Efficiency Output Power Output Voltage Range Output Current Voltage Programming Standby Bias Voltage Voltage Regulation Ouput Ripple & Noise Transient Response Switching Frequency Hold-Up Time Remote On/Off Current Limit Protection Short Circuit Protection Over Voltage Protection Operating Temperature Over Temperature Protection EMI LED Indicators Analog Status & Control Digital Status & Control Shock & Vibration Dimensions Weight Safety Approvals Options rev 100506 Lineage Power 3000 Skyline Dr. Mesquite, TX 75149 Phone: (972) 284-2000 Lineage Power 2841 Dow Avenue Tustin, CA 92780 USA Phone: (714) 544-6665 Lineage Power (China) 1353 Chenqiao Road, Shanghai Sengpu Industrial Park Shanghai, 201401 China Phone: 021 6710 8910 BENEFITS Minimizes space within your system Supports low profile applications Provides voltage source for housekeeping and monitoring circuitry Cost effective power scalability 1200 Watt +12V Front End Power Supply 85-264 VAC, 47-63 Hz 12A @ 100VAC, 8.1A @ 180 VAC, full Load 35A max. cold start (per ETS 300 132-1 and bellcore specifications) Single Fused (Line) 20 Amp / 250 VAC Type 3AB Axial 0.99 typical complies with IEC555, EN60555-2, EN61000-3-2 KEY MARKETS & APPLICATIONS Distributed Power Mid-End Servers Blade Servers Network Equipment Network Attached Storage Storage Area Networks 89% typical at 230 VAC Full Load Operation, 85% Typical @ 90 VAC Full Load Operation 1200W at High Line Operation (230 VAC), Derate to 1000W +12 VDC (5%) 100A @ +12 VDC for High Line Operation (230 VAC), reduced to 83.5 A at Low Line Operation (110 VAC) 5% of Vout nominal. Analog input signal. 11.4V + (Vprog x 0.3V) where Vprog = 0V to 4V 5VSB@500mA, reference to +12VDC Return 2% of Vnom for any combination of line, load and temperature ETS300 132-2, 32dBnrc. Bandwidth: 25Hz - 20kHz. 2mVrms pk-pk with 0.1F ceramic and 10F electrolytics caps 5% max deviation Recovery time 300s @ 50% load step and di/dt < 1A/s 400kHz (output) 20ms at 1200W (typical) @ 180VAC ON if >3V or open; OFF if <1V (max. sink 1mA) Open collector type 110-135% of Iout Nominal Self protected with auto recovery +14.5-15.5 VDC max, latched. Reset condition by recycling AC Input or toggling remote on/off -10C to +70C. power derating above 55C at 2.5% per C Non latching; protection active at 110C internal temperature, restart at 95C (typical) FCC-B & EN55022-B with specified filter, GR-1089-CORE Green = AC OK & DC OK, Red = Fault Voltage Programming (V Prog), Load sharing (I Share), Remote ON/OFF, Current Monitor (I Monitor),, Over temperature (Temp Warning), Fault, PS Present, Module Enable I 2C Option, see detailed specification for details IEC68-2-27, MIL-STD-810E, Telecordia GR-63-CORE 11.20 x 4.00 x 1.65" / 284.5 x 101.6 x 41.9mm 3.0 lbs IEC 950 per EN60950, UL60950, CSA 22.2-950, CE Mark (LVD) TUV I2C Signals, Bezel www.lineagepower.com/oem CAR1212FP Series 1200 Watt +12V Front End Power Supply OUTLINE DRAWING PART NUMBER DEFINITION GUIDE: PIN OUT INFORMATION A1 A2 A3 A4 A5 A6 B1 B2 B3 Vstb (5V) Vstb (5V) Return Signal Return Write Protect Remote Sense (+) Remote Sense (-) Fault I Monitor Module Enable B4 B5 B6 C1 C2 C3 C4 C5 C6 PS Present Serial Data Line Serial Data Clock I Share N/C Temp Warning I2C Address (A0) I2C Address (A1) I2C Address (A2) D1 D2 D3 D4 D5 D6 P1 P2 P3 V Prog OVP Test Point Remote On/Off DC OK AC OK Interrupt Line Neutral Chassis P4 P5 P6 P7 P8 P9 +V1 Return +V1 Return +V1 Return +V1 Output +V1 Output +V1 Output CAR 12 12 F P x xx -1A Series 12=1200W Output Current 12=12V Output Voltage F=Front End Type P=Positive Polarity Rev. Blank=Non-compliant YO=5 of 6 Compliant ZO=6 of 6 Compliant RoHS B=Bezel Option C=I2C Option BC=Both Options Options Examples: CAR1212FPY0-1A: 1200W/12V Front End, 5 of 6 RoHS CAR1212FPBZ0-1A 1200W/12V Front End, Bezel, 6 of 6 RoHS CAR1212FPCY0-1A 1200W/12V Front End, I2C, 5 of 6 RoHS CAR1212FPBCZ0-1A 1200W/12V Front End, I2C, Bezel, 6 of 6 RoHS D1 D2 D3 D4 D5 D6 P1 P2 P3 P4 P5 P6 P7 P8 P9 C1 C2 C3 C4 C5 C6 B1 B2 B3 B4 B5 B6 A1 A2 A3 A4 A5 A6 Connector is FCI / Berg Part No. 51939-178 Mates with FCI / Berg Part No. 51866-025 (Right Angle Mounting), or 51940-117 (Straight Mounting) rev 100506 Lineage Power 3000 Skyline Dr. Mesquite, TX 75149 Phone: (972) 284-2000 Lineage Power 2841 Dow Avenue Tustin, CA 92780 USA Phone: (714) 544-6665 Lineage Power (China) 1353 Chenqiao Road, Shanghai Sengpu Industrial Park Shanghai, 201401 China Phone: 021 6710 8910 www.lineagepower.com/oem |
Price & Availability of CAR1212FPCZ0-1A
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |