![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
A100ERU Series Single & Dual Output, 1.5W Ultra-Wide Input Range DC/DC Converters Electrical Specifications Specifications typical @ +25C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Key Features: * 1.5W Output Power * 4:1 Input Voltage Range * 1,500 VDC Isolation * -40C to +85C Temp Range * Compact DIP Case * Single & Dual Outputs * 1.0 MH MTBF * Industry Standard Pin-Out * Low, Low Cost! Parameter Input Voltage Range (See Note 1) Input Filter Short Circuit Input Power Conditions 24 VDC Input 48 VDC Input Min. 9.0 18.0 Typ. 24.0 48.0 1,000 Max. 36.0 72.0 Units VDC Capacitors mW Max. 3.0 0.75 2.0 100 50 120 0.03 Continuous (Autorecovery) Conditions 60 Seconds 500 VDC Min. 1,500 1,000 100 550 Conditions Ambient Min. -40 -50 Free Air Convection RH, Non-condensing 95 % Typ. Max. +85 +125 Typ. Max. Units VDC M pF kHz Units C C Units % % % % mV P - P mV P - P % %/C Output Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Noise (20 Hz - 300 kHz) Ripple (DC - 20 MHz) Output Power Protection Temperature Coefficient Output Short Circuit Dual Output , Balanced Loads Vin = Min to Max Iout = 10% to 100% See Note 2 Conditions Min. Typ. 1.0 3.0 0.2 0.5 50 General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size (See Note 3) 1.25 x 0.80 x 0.37 Inches (31.8 x 20.3 x 9.5 mm) Non-Conductive Black Plastic (UL94V-0) 0.52 Oz (15g) Conditions MIL HDBK 217F, 25C, Gnd Benign Conditions 24 VDC Input 48 VDC Input 1.5 mm From Case For 10 Sec All Models Min. 1.0 Min. -0.7 -0.7 Typ. Max. 50.0 100.0 300 1,500 Typ. Max. Units MHours Units VDC C mW Case Material (See Note 3) Weight MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Reliability Specifications Parameter MTBF Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com Model Selection Guide Input Model Number A101ERU A102ERU A103ERU A104ERU A105ERU A106ERU A107ERU A108ERU A111ERU A112ERU A113ERU A114ERU A115ERU A116ERU A117ERU A118ERU Voltage (VDC) Current (mA) Output www.micropowerdirect.com Efficiency (%, Typ) 73 75 78 80 81 73 78 79 72 74 77 79 80 72 77 78 Fuse Rating Slow-Blow (mA) 200 200 200 200 200 200 200 200 150 150 150 150 150 150 150 150 Voltage Current Current Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) 24 9.0 - 36.0 86 20 3.3 500 50.0 24 9.0 - 36.0 83 20 5.0 300 30.0 24 9.0 - 36.0 80 20 9.0 167 17.0 24 9.0 - 36.0 78 20 12.0 125 12.0 24 9.0 - 36.0 77 20 15.0 100 10.0 24 9.0 - 36.0 85 20 5.0 150 15.0 24 9.0 - 36.0 80 20 12.0 63 6.0 24 9.0 - 36.0 79 20 15.0 50 5.0 48 18.0 - 72.0 43 10 3.3 500 50.0 48 18.0 - 72.0 42 10 5.0 300 30.0 48 18.0 - 72.0 40 10 5.0 167 17.0 48 18.0 - 72.0 39 10 12.0 125 12.0 48 18.0 - 72.0 39 10 15.0 100 10.0 48 18.0 - 72.0 43 10 5.0 150 15.0 48 18.0 - 72.0 40 10 12.0 63 6.0 48 18.0 - 72.0 40 10 15.0 50 5.0 For models with a metal case, add an "M" to the model number (ie: A115ERUM) Notes: 1. Exceeding the input range by a significant margin may damage the units. For 24V input the input voltage should not exceed 40V; for 48V models it should not exceed 80V. 2. When measuring output ripple, it is recommended that an external 0.33 F ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. 3. The optional metal package is nickel plated steel. Dimensions are 1.25 x 0.80 x 0.39 Inches (31.8 x 20.3 x 10.0 mm). 4. These units should not be operated with a load under the specified minimum. Operation at no-load will increase ripple significantly and may cause damage to the unit. 5. These converters are specified for operation without external components. However, in some applications the addition of input/output capacitors will enhance stability and reduce output ripple. Recommended capacitor values are: Derating Curve Vin (VDC) Input Capacitor Sing 10 F Dual 10 ~ 47 F Sing 10 F Dual 10 ~ 47 F Vout (VDC) Output Capacitor 0 to +70C (Electrolytic) -40 to +85C (Tantalum) Mechanical Dimensions 24 48 3.3 5 12 15 100 F 100 F 100 F 100 F 47 F 47 F 47 F 47 F For applications requiring very low output noise levels, a simple LC filter should be effective. 6. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Pin Connections Pin 2, 3 9 10 11 14 15 16 22, 23 Single -Vin No Pin NC NC +Vout NC -Vout +Vin Dual -Vin Common NC -Vout +Vout NC Common +Vin NC: No Connection Mechanical Notes: MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 * * All dimensions are typical in inches (mm) * Tolerance x.xx = 0.01 (0.25) TEL: (781) 344-8226 * FAX: (781) 344-8481 * E-Mail: sales@micropowerdirect.com |
Price & Availability of A115ERU
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |