Part Number Hot Search : 
40HR308 S4806CBI RFR3806 P6KE10 28128 JAN4N49 RN498 1855MF9
Product Description
Full Text Search
 

To Download PSF149-401 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 WWW.PHIHONG.COM
150 Watt Universal Industrial Series PSF149 Quad-Output Enclosed Power Supply
Features * Low Cost * Enclosed Cover Applications * Test Equipment * Low Profile Racks * Process Control Safety Approvals Pending * cUL 1950, 3rd Edition * CE (Low Voltage Directive)
* Power Factor Correction * Low Profile Design * Networking * Business Machines
* TUV EN60950
Mechanical Characteristics Dimensions:Length: 201.4+/-0.1mm (7.93in) Width: 99.4+/-0.1mm (3.91in) Output Specifications
Model DC Outputs Voltage 5V -5V -12V +12V Min. 3A 0.2A 0.2A 1A Load Conv. 9A 0.6A 0.6A 3A
Height: 39.1+/-0.1mm (1.54in) Weight: 0.9kg (1.98lb.)
Ripple and Max.(30cfm) 15A 1A 1A 5A Noise 50mV p-p 100mV p-p 100mV p-p 100mV p-p
Regulation Line 1% 2% 2% 2% Load +5% +6% +6% +6%
PSF149-401
Phihong is not responsible for any errors or changes. Please contact the factory and visit www.phihong.com for the most up-to-date specifications.
PSF149 Characteristics INPUT: AC Input Voltage Rating 100 to 240VAC AC Input Voltage Range 90 to 264VAC AC Input Frequency 47 to 63Hz Input Surge Current 60A max.@cold start for 230VAC Input Current 4A max. OUTPUT: Efficiency 70% min.@115VAC and max. load Hold-up Time 16mS min.@120VAC and max. Load Power Factor Correction >0.9@max. load Overvoltage Protection 6.8V max. for +5V Overcurrent Protection All outputs equipped with short circuit protection
WWW.PHIHONG.COM
POWER SUPPLY
ENVIRONMENTAL: Operation Temperature 0 to 50C Storage Temperature -25C to +85C Humidity 20 to 90% Emissions FCC Class A EN 55022 Class A Immunity ESD EN61000-4-2: Level 3 RS EN61000-4-3: Level 2 FET/Burst EN61000-4-4: Level 2 Surge EN61000-4-5: (L-G) Level 3 (L-N) Level 2 CS EN61000-4-6: Level 2 DIP EN61000-4-11 Harmonic EN61000-3-2 Class D Flicker EN61000-3-3 GENERAL: Dielectric Withstand (HIPOT) Test Primary to secondary: 3000VAC 10mA 1 min.@without U-CASE MTBF (Full load, 25C) 50K Hrs min. at max. load 25C ambient temperature
Dimension Diagram Unit: mm (inch)
PSF149/0312


▲Up To Search▲   

 
Price & Availability of PSF149-401

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X