CC-1448-12 Operating Voltage = 250 Vac or Vdc @75oC Operating Voltage = 125 Vac or Vdc @100oC Operating Current (Max) = 12 AMP A/C or D/C Frequency = DC--60 HZ Temp range (Storage) = -40 to 125oC Temp range (Operating) @ 12.0 AMP= -65--100oC Dielectric Withstand voltage (Ph--Case) = 1500 Vac Dielectric Withstand voltage (Ph--Ph) = 1500 Vdc Leakage current @ 250 V~, 60 HZ = 2.5 MA max. Discharge Voltage after 60 sec = 34 V max. Weight = 1300 gram / 2.9 lb. Hermetically sealed Order p/n: CC-1448-12 90 80 INSERTION LOSS (db) 70 60 50 40 30 20 10 0 .01 .02 .04 .07 .1 .2 .4 .7 1 2 4 7 10 20 40 70 100 DM CM LINE LOAD FREQUENCY (MEGAHERTZ) 5.50 The CC-1448-12 is a single phase filter designed to function in the Mil-Std-461D Mil-Std-461E & Mil-Std-461F emissions Environment. The filter is also designed to function over a wide temperature range from -65 to +100 C. The fiter is hermetically sealed to meet moisture and immersion requirements, 2.25 1.60 1.60 0.42 8-32 INSERT (4X) 2.25 0.25 0.25 2.40 1.900 5.000 USA EUR JMK Inc 15 Caldwell Dr. Amherst, NH 03031 JMK Inc Glasgow G13 1DN Scotland UK PH: 603 886-4100 FX: 603 886-4115 email: info@jmkfilters.com PH: 44-(0) 7785310729 FX: 44-(0) 141 588 1884 |