Part Number Hot Search : 
12N60B3D 2SK13 60NE10 010012TD ACT4418D 4HAC10J LM3876 U200008
Product Description
Full Text Search
 

To Download MPE-25S Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 MPE-25S Series
Si l O Single Output, 25W 2 Compact, Enclosed AC/DC Power Supplies
Electrical Specifications
Key Features:
* 25W Output Power * Universal 85-264 AC Input * EN60950 Approved * Four Single Output Models * Meets EN55022 * >325 kHour MTBF * Compact Metal Enclosure
Specifications typical @ +25C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter Input Voltage Range Input Frequency Input Current Inrush Current Safety Ground Leakage Current Conditions Min. Typ. 85 120 47 See Model Selection Guide Cold Start, 115 VAC 15.0 Cold Start, 230 VAC 30.0 115 VAC 230 VAC Universal Max. 264 370 63 Units VAC VDC Hz A Pk 0.45 0.75 Max. mA Units
Output
Parameter Output Voltage Output Current Output Voltage Adjustment Output Voltage Tolerance, See Note 1 Ripple & Noise (20 MHz) , See Note 2 Conditions Min. Typ. See Model Selection Guide See Model Selection Guide See Model Selection Guide See Model Selection Guide See Model Selection Guide 115 VAC 12 230 VAC 80 115 VAC 800 230 VAC 300 115 VAC 50 230 VAC 50 0.02 Continuous (Autorecovery) See Note 3 115 See Note 4 135 Conditions Input to Output Input to Ground Output to Ground 500 VDC Conducted Electrostatic Discharge (ESD) RF Field Susceptibility Electrical Fast Transients/Bursts On Mains Surge Min. 3,000 1,500 500 Typ.
RoHS Compliant
Hold-Up Time Set-Up Time Rise Time Temperature Coefficient Short Circuit Protection Over Voltage Protection Overload Protection
mSec mSec mSec %/C 135 165 Max. % Vout % Iout Units VAC
General
Parameter Isolation Voltage Isolation resistance EMI/RFI
MicroPower Direct
292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com
EMC Compliance Switching Frequency
100 M EN 55022; EN 61000-3-2, -3 IEC/EN 61000-4-2, -6, -8, -11 IEC/EN61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 56 kHz Units C C %
Environmental
Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Min. Typ. Max. -10 +25 +60 -20 +85 Free Air Convection (See Derating Curve) RH, Non-condensing 20 90 Ambient
Physical
Case Size Case Material Weight 3.90 x 3.82 x 1.42 Inches (99.0 x 97.0 x 36.0 mm) Vented Metal Enclosure 13.7 Oz (0.39 kg) Conditions Min. Typ. Max. Units MIL HDBK 217F, 25C, Gnd Benign 325 kHours IEN 60950, IEC 60950 10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
Reliability Specifications
Parameter MTBF Safety Standards Vibration
Model Selection Guide
Input Model Number MPE-25S-05 MPE-25S-12 MPE-25S-15 MPE-25S-24 Current (A) 115 VAC 0.6 0.6 0.6 0.6 230 VAC 0.35 0.35 0.35 0.35 Voltage (VDC) Rated 5.0 12.0 15.0 24.0 Adjust 4.75 - 5.5 10.8 - 13.2 13.5 - 16.5 21.6 - 26.4 Output Current (A) Rated 5.0 2.1 1.7 1.1 Range 0 to 5.0 0 to 2.1 0 to 1.7 0 to 1.1 Output Voltage Tolerance (%) 2.0 1.0 1.0 1.0 Ripple & Noise
(mV p-p)
Efficiency
(%, Typ)
50 100 100 100
72 76 77 80
Notes: 1. Output voltage tolerance includes the the effects of set point accuracy, line regulation and load regulation. 2. Ripple and noise is measured at 20 MHz bandwidth using a 12 inch twisted pair wire to connect to the power supply terminals. A 0.1 F and a 47 F capacitor are connected in parallel as close to the power supply terminals as possible. 3. Overvoltage protection is provided by a "hiccup mode" circuit. The unit recovers automatically when the fault condition is removed. 4. Overload protection is provided by foldback current limiting. The unit recovers automatically when the fault condition is removed. 5. Efficiency is measured with a 115 VAC input. 6. It is recommended that a fuse be used on the input of a power supply for protection. For the MPE-25S series, a 2.5A/250 VAC slow blow should be used.
Mechanical Dimensions
Pin Connections
Pin 1 2 3 4 5 Function -Vout +Vout AC-Ground AC-Line AC-Neutral
Notes: * All dimensions are typical in inches (mm) * Tolerance x.xx = 0.01 (0.25)
Derating Curve Static Characteristics (24 Vout)
MicroPower Direct
www.micropowerdirect.com
*
292 Page Street Ste D Stoughton, MA 02072
TEL: (781) 344-8226
*
FAX: (781) 344-8481
*
E-Mail: sales@micropowerdirect.com